• Title/Summary/Keyword: thickness measurement of screen

Search Result 17, Processing Time 0.027 seconds

The Opening Size Change for Screen Tension (스크린 망사의 견장과 오프닝의 변화)

  • Jung, Gi-Young;Kang, Young-Reep
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.28 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • The 200mesh screen was tensioned and fixed on a frame. When applied tension to 5N and 10N per unit area, a side length of opening of the screen was 163.223${\mu}m$ and 168.224${\mu}m$, respective. But side length not tensioned was 158.879${\mu}m$. We knew that a side length of opening of the screen rarely changes with tension applied to the screen. The appearances that a side length of opening of the screen expand little are due to a decreasing diameter of thread by means of tension. In a thickness measurement of screen, While the high density mesh screen that had a lot of knots that crossed a line of latitude and longitude per unit area appeared a higher numerical value, the low density mesh screen that had a few knots appeared a low numerical value.

The study of X-ray detection characteristic and fabrication photoconductor film thickness for Screen printing method (Screen printing method로 제작된 의료용 광도전체 필름의 Tickness의 따른 X선 검출 특성 평가)

  • Lee, Y.K.;Yon, M.S.;KIM, D.H.;Chun, S.L.;Jung, B.D.;Gang, Sang-Sik;Park, J.G.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.11-16
    • /
    • 2009
  • Mercury Iodide as good sensitivity at radiation and has an easy peculiarity that operates at low voltage for other photoconductors(a-Se, a-Si, Ge, etc) Based on this characteristic, we studied about an efficiency of the digital x-ray detector in acccordance with the thickness of photoconductor. To solve the problem that is difficult to make a large area film using PVD(Physical Vapor Deposition)method, we used a PIB(Particle In Binder)method. To make a binder paste, we used a PVB(Polyvinylbutyral) as a binder and a DGME(Diethylene Glycol Monobutyl Ether), DGMEA(Diethylene Glycol Monobutyl Ether Acetate) as a solvent. Using this binder paste, we made a polycrystal mercury iodide film that has an each thickness. To evaluate the electrical properties of this films, we measured a darkcurrent, sensitivity and SNR(Signal to Noise Ratio). Mercury iodide film of the 200um thickness has good electrical properties as a result of the measurement. From this result there is a good chance that replace the existing a-Se(Amnorphous seleinum; a-se) with the mercury iodide.

  • PDF

Evaluation of White LED Package Characteristics in Remote Phosphor Structure Depending on Phosphor Coatings (형광체 코팅에 따른 Remote Phosphor 구조의 백색 LED 패키지 특성 평가)

  • Jeong, Hee-Suk;Lee, Jung-Geun;Kang, Han-Lim;Hwang, Myung-Keun;Lee, Mi-Jae;Kim, Jin-Ho;Chae, Yoo-Jin;Lee, Young-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.4
    • /
    • pp.330-334
    • /
    • 2013
  • We developed a package of remote phosphor structure having blue LED chips and phosphors physically separated, and the characteristics were evaluated according to different classifications of phosphor coatings. Remote phosphor was produced by screen printing coating on glass substrate with phosphor content rated paste and heat treatment. After mounting Remote phosphor, which has been classified according to number of coatings, on top of blue LED chips, luminous flux, luminous efficacy, CCT and CRI were measured. The measurement results showed the most suitable characteristics of white LED package as a general light source when the content rate of phosphor in Remote phosphor was 80 wt.% with 3 layers of coatings and thickness over $12{\mu}m$.

Study on the dark current reduction of $HgI_2$ radiation detector ($HgI_2$ 방사선 검출기의 누설전류 저감에 관한 연구)

  • Shin, Jung-Wook;Kang, Sang-Sik;Kim, Jin-Young;Kim, Kyung-Jin;Park, Sung-Kwang;Jo, Heung-Lae;Lee, Hyung-Won;Nan, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.456-459
    • /
    • 2004
  • Analog film/screen systems have been being changed to a digital x-ray imaging device using direct conversion materials. Photocoductors for a direct detection flat-panel imager require high x-ray absorption, ionization and charge collection, low leakage current and large area deposition. In this work, $HgI_2$ films with excellent properties for x-ray detector were deposited by screen printing method. The thickness of $HgI_2$ film was about $150\;{\mu}m$. The passivation layer is fabricated using a-Se and parlyene, the both fabrication $HgI_2$ film were compared for analyzing the leakage current reduction. We measured electrical properties-leakage current, photosensitivity, SNR though I-V measurement, As the result, $HgI_2$ film using a-Se passivation layer had the greater

  • PDF

Regional Image Noise Analysis for Steel-tube X-ray Image (강판튜브 엑스선 영상의 영역별 영상잡음 특성분석)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.32-34
    • /
    • 2007
  • The X-ray projection system has long been used for steel-tube inspection and weld monitoring. The thickness of tubes and welded areas is based on the evaluation of radiographic shadow projections. The traditional tangential measurement estimates the distance of border lines of the projected wall shadows of a tube onto a radiographic image detector. The detected image in which although there is a variety of noise may be sectioned into several partitions according to its specific blocks. Imaging noise originates from most of elements of the system, such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc. The tangential projection incorrectness and noise influence on imaging quality. In this paper we first sectionalize the X-ray image on the basis of vertical contrast difference. And next functional and statistic analysis are carried on at each region. Geometrical distance and unsharpness of the edge caused by visual evaluation uncertainties are also discussed.

  • PDF

A Evaluation of Shielding Deficiency by Means of Gamma Scanning Test (Gamma Scanning Test에 의한 대단위 차폐체의 결함 평가 연구)

  • Lee, B.J.;Seo, K.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.228-236
    • /
    • 1995
  • In this paper the method to evaluate shielding deficiency by gamma scanning test was presented and verified theoretically by Monte Carlo code which is one of the best effective method for radiation shielding calculation. The cylindrical shielding model was selected to evaluate shielding deficiency by gamma scanning test. First, the reference shielding according to the design requirement of cask was fabricated specially and reference values were measured with Co-60 source and scintillation detector. As a result with which calculated the reference values, it is shown that maximum deficiency thickness for lead of true cylindrical shielding model was 12mm. To verify this, thickness of lead was calculated by MCNP code and maximum deficiency thickness was 11.6mm. The experimental result obtained by the use of reference shielding was in good agreement with the theoretical result within 4.1%. So, this method can be applied to inspect the shielding ability for great shielding or cask which the radioactive material is used. To perform measurement more exactly, the further work on the development of measuring equipment to display the results on the screen will be required.

  • PDF

Screen-printed carbonaceous matrrials for photocapacitor electrode (스크린 프린터에 의한 광캐패시터용 카본 전극 제작)

  • Choi, Woo-Jin;Kwak, Dong-Joo;Sung, Youl-Moon;Ha, Soon-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.411-414
    • /
    • 2009
  • Photo-capacitor electrodes are attracting great attention because of their high capacitance and potential applications in electronic devices. Carbon capacitor, active carbon capacitor and its combination will be fabricated using simple sandwich capacitor electrode method as carbonaceous material on each type of capacitor electrodes with 20 ${\times}$ 15 mm cell size. Carbon/active carbon cell was fabricated using sol-gel process with 120oC dry temperature in l hour and using sintering process with 500oC in 2 hour. The effect of sintering temperature on carbon properties was also investigated with X-ray diffraction technique to get the best sintering temperature. The detail of fabrication process will be explained. Elemental composition in electrode material can be measured using quantitative spectroscopic as and a cyclic voltammetric technique was used to study the combined effects of electrode material and effect of annealing temperature and also time on the capacitance of thermally treated in capacitor electrode. In this work, characterization impedance technique is used to measurement of capacitance and giving complementary results. Active carbon as carbonaceous material has a better capacitance in charge/discharge process with mean thickness $32{\mu}m$ and with particle size $1{\mu}m$ to $4.5{\mu}m$ in 20 ${\times}$ 15 mm sample size of capacitor electrode.

  • PDF

A Study on the Image Quality of Mammography and the Average Glandular Dose (맘모그래피의 화질과 평균유선조직선량에 관한 검토)

  • Lee, In-Ja;Kim, Hak-Sung;Kim, Sung-Soo;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.47-55
    • /
    • 2002
  • We came to the following conclusion as the results of experiment on the image quality of mammography and the average glandular dose using 4 apparatuses at 3 hospitals in Seoul. 1. Whereas the measurement of half value layer showed no differences among the apparatuses, the measurement by an attenuation curve method showed some differences by 5.9%. There were 9.1% differences in the measurement by aluminum conversion method. 2. The basic density of an automatic exposure control unit must be D = 1.40, but there was no automatic exposure unit adjusted precisely at any hospitals. The unit at the B hospital exceeded the allowable limit by ${\pm}0.15$. 3. In the photographing using an automatic exposure control unit and the management of an automatic film processor using a sensitometer, most automatic film processors were well kept. But in some cases the mean value of a fluctuation coefficient exceeded the allowable limit. There is a need for more cautious management. 4. The image quality of breast phantom photography was affected by the screen/film system among the hospitals. 5. The average glandular dose at a breast of 4.2 cm thickness depended on the tube voltage, In the case of Mo/Mo, it was measured $0.26{\sim}1.39\;mGy$ less than ACR standard 3.0 mGy.

  • PDF

Development of Mobile Type Computer Vision System and Lean Tissue Extraction Algorithm for Beef Quality Grading (쇠고기 등급판정을 위한 이동형 컴퓨터시각 장치 및 살코기 추출 알고리즘 개발)

  • Choi S.;Huan Le Ngoc;Hwang H.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.6 s.113
    • /
    • pp.340-346
    • /
    • 2005
  • Major quality features of the beef carcass in most countries including Korea are size, marbling state of the lean tissue, color of the fat and lean tissue, and thickness of back fat of the 13th rib. To evaluate the beef quality, extracting loin parts from the sectional image of the 13th beef rib is crucial and is the first step. However, because of the inhomogeneous distribution and fuzzy pattern of the fat and lean tissues on the beef cut, it is difficult to extract automatically the proper contour of the lean tissue. In this paper, a prototype mobile beef quality measurement system, which can be implemented practically at the beef processing site was developed. The developed system was composed of the hand held image acquisition unit and mobile processing unit mounted with touch-pad screen. Algorithms to extract the boundary of the lean tissue and a proper tool to evaluate the marbling status have been developed using color image processing. The boundary extraction algorithm showed successful results for the beef cuts with simple and moderate patterns of the lean tissue and fat. However, it had some difficulty in eliminating complex pattern of the extraneous tissues adhered to the lean tissue in the boundary extraction. The developed algorithms were implemented to the prototype mobile processing unit.

Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System (Computed Radiography 시스템에 $^{192}Ir$$^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교)

  • Kang, Sang-Mook;Chol, Chang-Il;Lee, Seung-Kyu;Park, Sang-Ki;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.26-33
    • /
    • 2010
  • A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using $^{75}Se$ and $^{192}Ir$ with welded objects. We analyzed the gray scale of hole defect image by using XCAP image processing program and calculated the image contrast and SNR in definition. Also the sesitivities of image quality indicator(IQI) were calculated for hot and cooling tube image of $^{75}Se$ and $^{192}Ir$.