• Title/Summary/Keyword: thickness evaluation

Search Result 1,812, Processing Time 0.038 seconds

A study on the Nutritional status for School-Children of Bong-do Primary School, Busan, Korea, 1972. (부산 송도국민학교 아동들의 영양 상태에 관한 연구)

  • 오영숙
    • Journal of Korean Academy of Nursing
    • /
    • v.3 no.3
    • /
    • pp.73-77
    • /
    • 1973
  • A study on the nutritional status for school-children has been carried out 1,700 school- children of Song-do primary school located in Song-do beach, Busan, Korea, from November to-December, 1972. The evaluation of the nutritional status has been carried out through skin-fold thickness and hemoglobin. The summarized results were as follows. : 1. Skinfolds thickness 1) Subcellular skinfolds thickness . Among boys, that was 3.5mm in the age 6 and 5.4mm in the age 11 Among girls, that was 4.2mm in the age 6 and 7.6mm in the age 11. Girls were thicker than toys in the all age. 2) Upper-arm skinfolds thickness Among boys, that was 5.0mm in the age 6 and 6.8mm in the age 11. Among girls, that was 6.2mm in the age 6 and 8.7mm in the age 11. Girls were thicker than toys in the all age. 3)Abdominal skinfolds thickness. Among boys, that was 4.0mm in the age 6, and 6.4mm in the age 11. Among girls that was 4.0mm in the age 0, and 8.4mm in the age 11. Girls were thicker than boys in the all age. 2. Hemoglobin Proportional range of hemoglobin were observed as 12.2-12.8 gm/㎗.

  • PDF

Experimental Investigation of Impact-Echo Method for Concrete Slab Thickness Measurement

  • Popovics John S.;Cetrangolo Gonzalo P.;Jackson Nicole D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.6
    • /
    • pp.427-439
    • /
    • 2006
  • Accurate estimates of in place thickness of early age (3 to 28 days after casting) concrete pavements are needed, where a thickness accuracy of ${\pm}6mm$ is desired. The impact-echo method is a standardized non-destructive technique that has been applied for this task. However, the ability of impact-echo to achieve this precision goal is affected by Vp (measured) and ${\beta}$ (assumed) values that are applied in the computation. A deeper understanding of the effects of these parameters on the accuracy of impact-echo should allow the technique to be improved to meet the desired accuracy goal. In this paper, the results of experimental tests carried out on a range of concrete slabs are reported. Impact-echo thickness estimation errors caused by material property gradients and sensor type are identified. Correction factors to the standard analysis method are proposed to correct the identified errors and to increase the accuracy of the standard method. Results show that improved accuracy can be obtained in the field by applying these recommendations with the standard impact-echo method.

Changes in Abdominal Muscle Thickness and Balance Ability on Plank Exercises with Various Surfaces

  • Kang, Kyung-Woo;Son, Sung-Min;Ko, Yu-Min
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.5
    • /
    • pp.264-268
    • /
    • 2016
  • Purpose: This study was conducted to investigate the effects on muscle thickness and balance ability after performing plank exercise on various surface types. Methods: In this study, there were thirty healthy participants. Participants were randomly distributed into three groups, a control group (n=10), sling group (n=10), and ball group (n=10). All participants performed plank exercises three times a week for four weeks. Plank exercises consisted of five sets of 30 seconds each with a one minute break between each set. Muscle thickness of the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) was measured using an ultrasound diagnostic apparatus and balance was measured using I-balance. Results: Evaluation of muscle thickness revealed that the IO and EO muscle of the ball group changed significantly relative to the control group (p<0.05). However, there were no significant changes in balance. Conclusion: The results revealed that performing plank exercise on a ball is more effective among various types of surfaces.

Evaluation of Flaws in Adhesively Bonded Joint using Ultrasonic Signal Analysis (초음파 신호분석을 이용한 접착접합 이음의 결함평가)

  • Hwang, Yeong-Taik;Oh, Seung-Kyu;Han, Jun-Young;Jang, Chul-Sup;Yun, Song-Nam;Yi, Won;Kim, Hwan-Tae
    • Journal of Welding and Joining
    • /
    • v.22 no.2
    • /
    • pp.38-45
    • /
    • 2004
  • Ultrasonic signals transmitted through adhesively bonded plates were used to evaluate parameters related to attenuation and frequency in the adhesively bonded joint. The kinds of bonding materials with a different bonding thickness of constant pressure were used. And ultrasonic diagnosis was evaluated by p-wave sensor of 10MHz. FFT has been performed to determine bond-layer parameters such as effective thickness and frequency for adhesively bonded joint of A16061 plates in comparison with measured to theoretical ratios. When variable thickness exists, the ultrasonic spectrum was changed the frequency wave. The more materials thickness and the higher the frequency, the larger shift was observed. Measured ratios for cases of bond thickness and variety bonding materials are then used to determine bond parameters. The results show that the technique can be applied to the characterization of adhesively bonded joint.

Three-dimensional evaluation of maxillary anterior alveolar bone for optimal placement of miniscrew implants

  • Choi, Jin Hwan;Yu, Hyung Seog;Lee, Kee Joon;Park, Young Chel
    • The korean journal of orthodontics
    • /
    • v.44 no.2
    • /
    • pp.54-61
    • /
    • 2014
  • Objective: This study aimed to propose clinical guidelines for placing miniscrew implants using the results obtained from 3-dimensional analysis of maxillary anterior interdental alveolar bone by cone-beam computed tomography (CBCT). Methods: By using CBCT data from 52 adult patients (17 men and 35 women; mean age, 27.9 years), alveolar bone were measured in 3 regions: between the maxillary central incisors (U1-U1), between the maxillary central incisor and maxillary lateral incisor (U1-U2), and between the maxillary lateral incisor and the canine (U2-U3). Cortical bone thickness, labio-palatal thickness, and interdental root distance were measured at 4 mm, 6 mm, and 8 mm apical to the interdental cementoenamel junction (ICEJ). Results: The cortical bone thickness significantly increased from the U1-U1 region to the U2-U3 region (p < 0.05). The labio-palatal thickness was significantly less in the U1-U1 region (p < 0.05), and the interdental root distance was significantly less in the U1-U2 region (p < 0.05). Conclusions: The results of this study suggest that the interdental root regions U2-U3 and U1-U1 are the best sites for placing miniscrew implants into maxillary anterior alveolar bone.

An ionization Chamber for a Steel Sheet Thickness Measurement

  • Kim, Han-Soo;Park, Se-Hwa;Kim, Yong-Kyun;Ha, Jang-Ho;Cho, Seung-Yeon
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.149-153
    • /
    • 2006
  • An ionization chamber is still widely used in many fields by virtue of its' simple operational characteristics and the possibility of its' various shapes. A parallel type of an ionization chamber for a steel sheet thickness measurement was designed and fabricated. High pure xenon gas, which was pressurized up to 6 atm, was chosen as a filling gas to increase the current response and sensitivity for a radiation. A high pressure gas system was also constructed. The active volume and the incident window size of the fabricated ionization chamber were $30\;cm^3\;and\;12\;cm^2$, respectively. Preliminary tests with a 25 mCi $^{241}Am$ gamma-ray source and evaluation tests in a standard X-ray field were performed. The optimal operation voltage was set from the results of the collection efficiency calculation by using an experimental two-voltage method. Linearity for a variation of the steel sheet thickness, which is the most important factor for an application during a steel sheet thickness measurement, was 0.989 in this study.

Effect of translucency on CAD/CAM ceramic according to different core/veneer thickness (캐드캠 세라믹의 코어와 베니어의 서로 다른 두께가 반투명도에 미치는 영향)

  • Kang, Wol;Kim, Ji-Hwan
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.6
    • /
    • pp.1037-1045
    • /
    • 2018
  • Objectives: The purpose of this study was to evaluation the effect of translucency on CAD/CAM ceramic according to different core/veneer thicknesses. Methods: A total of 42 samples from 2 groups of 7 ceramic cores, each with 3 thickness values (0.8, 1.0, 1.2 mm) were manufactured. The veneers were also manufactured in 3 thicknesses (0.3, 0.5, 0.7 mm). The group names were based on the name of the ceramic core (IPS e.Max CAD; LD, and IPS Empress CAD; LR). The associated number was determined by the combined thickness of the core and veneer: 1 = (0.8 + 0.7); 2 = (1.0 + 0.5); 3 = (1.2 + 0.3). The translucency was measured using a spectrophotometer and defined via the contrast ratio (CR) and translucency parameter (TP). Two-way ANOVA was performed to compare the 2 groups (material and thickness). Results: As the core thickness increased, the TP value also increased, and the CR value (for LR group) decreased. The results of 2-way ANOVA demonstrated that the thicknesses of different core/veneer combinations significantly affected the translucency (p<0.05). Conclusions: The different core and veneer thicknesses affected the translucency of CAD/CAM ceramic.

Multifidus Thickness Comparison between the Effectiveness of Abdominal Bracing and Maximum Expiration Maneuvers in Lumbo-Pelvic Upright Sitting Posture

  • Ko, Minjoo;Kim, Sujung
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.4
    • /
    • pp.2178-2183
    • /
    • 2020
  • Background: Trunk flexor-extensor muscles' co-activation and upright posture are important for spinal stability. Abdominal bracing and maximal expiration are being used as exercises to excel torso co-contraction. However, no study has on comparison of the effect of this exercise on multifidus in the upright sitting posture. Objectives: This study aims to verify the effectiveness of abdominal bracing and expiration maneuvers in lumbo-pelvic upright sitting. Design: Cross-sectional study. Methods: Eighteen healthy women were recruited for this study. The multifidus muscle thickness of all subjects was measured in three sitting conditions (lumbo-pelvic upright sitting, lumbo-pelvic upright sitting with abdominal bracing, and lumbo-pelvic upright sitting with maximum expiration) using ultrasound. One-way repeated measure analysis of variance was used for the evaluation. Results: Compared to lumbo-pelvic upright sitting, lumbo-pelvic upright sitting with abdominal bracing and lumbo-pelvic upright sitting with maximum expiration were associated with significantly increment of muscle thickness. There was no significant difference in muscle thickness between lumbo-pelvic upright sitting with abdominal bracing and lumbo-pelvic upright sitting with maximum expiration. Conclusion: Abdominal bracing and maximum expiration could be beneficial to increasing lumbar multifidus thickness in lumbo-pelvic upright sitting.

Impedance investigation of the surface film formed on aluminum alloy exposed to nuclear reactor emergency core coolant

  • Junlin Huang;Derek Lister;Xiaoliang Zhu;Shunsuke Uchida;Qinglan Xu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1518-1527
    • /
    • 2023
  • A method was proposed for in-situ evaluating the thickness and resistivity of the oxide/hydroxide film formed on the surface of aluminum alloy exposed to sump water formed in the containment after a loss-of-coolant accident. The evaluation entailed fitting a model for the film impedance, which has film thickness and other variables describing the resistivity profile of the film along its thickness direction as fitting parameters, to the practically measured electrochemical impedance data. The obtained resistivity profiles implied that the films formed at pHs25℃ 7, 8, 9, 10, and 11 all had a duplex structure; compared to the outer layer in contact with the solution, the inner layer of the film had a much higher resistivity and was inferred to be denser and provide most of the protectiveness of the film. Both the thickness and the total resistance of the film decreased with the increasing solution pH25℃, suggesting that the films formed in more alkaline solutions had less protectiveness against corrosion, consistent with the increasing aluminum alloy corrosion rates previously identified.

Neutron dosimetry with a pair of TLDs for the Elekta Precise medical linac and the evaluation of optimum moderator thickness for the conversion of fast to thermal neutrons

  • Marziyeh Behmadi;Sara Mohammadi;Mohammad Ehsan Ravari;Aghil Mohammadi;Mahdy Ebrahimi Loushab;Mohammad Taghi Bahreyni Toossi;Mitra Ghergherehchi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.753-761
    • /
    • 2024
  • Introduction: In this study, TLD 600 and TLD 700 pairs were used to measure the neutron dose of Elekta Precise medical linac. To this end, the optimum moderate thickness for the conversion of fast to thermal neutrons were evaluated. Materials and methods: 241Am-Be and 252Cf sources were simulated to calculate the optimum thicknesses of the moderator for the conversion of maximum fast neutrons (FN) into thermal neutrons (TN). Pair TLDs were used to measure F&TN doses for three different field sizes at four depths of the medical linac. Results: The maximum thickness of the moderator was optimized at 6 cm. The measurement results demonstrated that the TN dose increased with the expansion of field size and depth. The FN dose, which was converted TN, exhibits behaviors comparable to the TN due to its nature. Conclusion: This study presents the optimum thickness for the moderator to convert FN into TN and measure F&TN using TLDs.