• 제목/요약/키워드: thickness evaluation

검색결과 1,817건 처리시간 0.03초

SH-EMAT를 이용한 알루미늄 박판의 두께감육 평가 (Evaluation of Thickness Reduction in an Aluminum Sheet using SH-EMAT)

  • 김용권;박익근
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.74-78
    • /
    • 2010
  • In this paper, a non-contact method of evaluating the thickness reduction in an aluminum sheet caused by corrosion and friction using SH-EMAT (shear horizontal, electromagnetic acoustic transducer) is described. Since this method is based on the measurement of the time-of-flight and amplitude change of guided waves caused from the thickness reduction, it provides information on the thinning defects. Information was obtained on the changes of the various wave features, such as their time-of-flight and amplitude, and their correlations with the thickness reduction were investigated. The interesting features in the dispersive behavior of selected guided modes were used for the detection of thinning defects. The measurements of these features using SH waves were performed on aluminum specimens with regions thinned by 7.2% to 29.5% of the total thickness. It is shown that the time-of-flight measurement provides an estimation of the thickness reduction and length of the thinning defects.

An Ultrasonographic Evaluation of Masseter Muscle Thickness in Patients Having Parafunctional Habit

  • Odkhuu, Michidgerel;Kim, Jinwoo;Kim, Sun-Jong
    • Journal of Korean Dental Science
    • /
    • 제13권2호
    • /
    • pp.59-66
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the masseter muscle thickness before and after treatment using ultrasound sonography in patients with parafunctional habits. Materials and Methods: From September 2019 to March 2020, a total of 27 patients who visited the Department of Oral and Maxillofacial Surgery at Ewha Womans University Seoul Hospital were collected. The thickness of both masseter muscles was measured using a tablet ultrasound scanner. Statistical analysis was performed by using the IBM SPSS version 26.0 statistical package (IBM Corp) with significance level at 0.05. Result: According to the statistical results, the thickness of the masseter muscle was thicker on the right side than on the left, with no correlation with sex or age. The severity and duration of pain did not have a significant correlation with the thickness of the masseter muscle. Botulinum A toxin injection in the masseter muscle was the most effective way to reduce pain and reduce the thickness of the masseter muscle. Splint treatment also showed some effects in reducing the thickness of the masseter muscle. Conclusion: Based on the findings, it can be claimed that ultrasonography is simple, inexpensive and easily repeatable method to get real-time diagnosis and treatment results for masseter muscles.

Evaluation of BMI as an Obesity Index for Korean

  • Kim, Youngok;Lee, Soon-Young;Kim, Seon-Woo;Kim, Kyung-Hee
    • Journal of Community Nutrition
    • /
    • 제2권2호
    • /
    • pp.129-134
    • /
    • 2000
  • The purpose of the present study is to evaluate the validity of the BMI as an indicator of obesity for Koreans. The usefulness of the BMI to represent overweight and obesity was evaluated by measuring the relative validity of sensitivity and specificity, and was compared with the validity of triceps skinfold thickness(mm). To measure the relative validity of the BMI and triceps skinfold thickness, body fat(%) was used as a reference measure of obesity. The study population included 844 participants aged 20-69 years who resided in Kuri City in Kyunggi province. Participants were measured regarding weight, height, triceps skinfold thickness and body fat. The prevalence of obesity for male subjects was 32.0%, 66.2%, and 0.9%, and for female subjects, 17.6%, 56.1%, 12.4% based on the BMI, triceps skinfold thickness, and body fat(%) respectively. The prevalence of obesity was higher based on the BMI or triceps skinfold thickness than body fat measurement. The sensitivity and specificity of the BMI were 33.3% and 67.9% in male subjects and 77.7% and 90.8% in female subjects. Sensitivity of the BMI was lower, and specificity was higher than those of triceps skinfold thickness. In summary, BMI as an indicator of obesity for Korean showed a tendency of overestimation of obesity prevalence. Therefore, there is a need to develop a more reliable obesity index other than the BMI for Koreans.

  • PDF

Design and Performance Evaluation of Mini-Lightweight Piezo-Composite Actuators

  • Tran, Anh Kim;Yoon, Kwang-Joon
    • Advanced Composite Materials
    • /
    • 제18권4호
    • /
    • pp.327-338
    • /
    • 2009
  • In this paper, through an evaluation process conducted on several designs of mini-LIPCA (Lightweight Piezo-Composite curved Actuator), an optimal design of a mini-LIPCA has been proposed. Comparing with the LIPCA-C2, the design of the mini-LIPCA comes with reduced overall size and a thinner active layer. Since a variation in the number and lay-up of fiber composite layers may strongly affect the performance of the device, one is able to configure several designs of mini-LIPCA. The evaluation process is then followed in order to determine a configuration which characterizes the possibly optimal performance. That is, a design of a mini-LIPCA is said to be optimal if it is capable of producing a maximum out-of-plane displacement. The size of the LIPCA to be investigated was selected to be $10\;mm\;{\times}\;20\;mm$ in which the thickness of PZT plate is about 0.1 mm. The thickness of glass/epoxy and carbon/epoxy are about 0.09 mm and 0.1 mm, respectively. The evaluation process has been conducted thoroughly, i.e., analytical estimation, numerical approximation and the experimental measurement are all involved. Firstly, the design equation was used to calculate essential parameters of proposed lay-up configurations. Secondly, ANSYS, a commercial FEA package, was utilized to estimate displacement outputs of the actuators upon being excited. Finally, experimental measurements were able to verify the predicted results.

해상에서 심혈관질환 예측인자로 BIA 활용가능성 분석 (혈중 총콜레스테롤과 부위별 지방두께 비교) (BIA Feasibility Analysis as Predictors of Cardiovascular Disease in the Sea (Total Cholesterol Compared with Fat Thickness by Region))

  • 나승권;박은주
    • 한국항행학회논문지
    • /
    • 제18권6호
    • /
    • pp.582-587
    • /
    • 2014
  • 본 연구는 장기간의 해상활동으로 의료기관 방문이 어려운 해상 활동자의 심혈관계질환 예측인자로 검사가 용이한 생체전기저항분석법 (BIA; bioelectrical impedance analysis)의 활용이 가능한지를 확인해보았다. 현재 심혈관성질환의 예측인자로 사용되고 있는 총콜레스테롤 측정치를 기준으로 BIA의 측정치와 관련성을 통계적 방법으로 분석한 결과 인체부위별 지방두께와 상관관계를 보였으며, 특히 왼쪽(왼) 허벅지의 지방두께가 총 콜레스테롤 측정치와 높은 상관관계를 나타냈다. 이 결과로 장기적인 해상 활동을 요하는 사람들은 BIA 검사를 통해 왼허벅지의 지방두께 변화를 심혈관질환의 예측인자로 활용할 수 있을 것이다. 하지만 선행연구의 부재로 후속연구가 필요하고 해상이라는 특수 상황이 고려된 측정도구의 정확성과 타당성 진단이 이루어져야 될 것으로 사료된다.

Effect of Specimen Thickness by Simulation of Probabilistic Fatigue Crack Growth

  • Kim, Seon-Jin
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 추계학술대회 논문집
    • /
    • pp.232-237
    • /
    • 2001
  • The evaluation of specimen thickness effect of fatigue crack growth life by the simulation of probabilistic fatigue crack growth is presented. In this paper, the material resistance to fatigue crack growth is treated as a spatial stochastic process, which varies randomly on the crack surface. Using the previous experimental data, the non-Gaussian(eventually Weibull, in this report) random fields simulation method is applied. This method is useful to estimate the probability distribution of fatigue crack growth life and the variability due to specimen thickness by simulating material resistance to fatigue crack growth along a crack path.

  • PDF

원전감육배관 UT 두께측정 결과의 신뢰도 평가를 위한 다자비교시험 (Round Robin Test for Reliability Evaluation of Ultrasonic Thickness Measurement Results in Nuclear Power Plant Pipelines)

  • 이승준;이원근;이준현;이성호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1702-1707
    • /
    • 2007
  • The reduction of pipe-thickness induced by flow accelerated corrosion (FAC) is one of the most serious problems on the maintenance of piping system in nuclear power plants (NNP). If the thickness of a pipe component is reduced below the critical level, it cannot sustain pressure and consequently results in leakage or rupture. For this reason, wall thinning by FAC has been inspected in secondary side piping systems in NPPs. In this research Round Robin Test (RRT) was conducted to verify confidence of wall thinning measurement system in NPP. 12 inspectors from 3 companies participated and 23 specimens were used according to standard practice in RRT. The gage R&R analysis was introduced in regard to repeatability and reproducibility that are affected to measurement system errors. Confidence intervals of thickness measurement system were obtained.

  • PDF

고성능 콘크리트 교면포장의 최적 두께 평가 (Evaluation of Optimum Thickness of High Performance Concrete Bridge Deck Pavement)

  • 박해균;김지원;전상은;이명섭;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.318-321
    • /
    • 2006
  • The objective of this study is to evaluate the optimum thickness of High Performance Concrete bridge deck pavement. The application of High Performance Concrete bridge deck pavement with micro-silica was introduced to north America in the early 1980's. In order to decide the optimum thickness of High Performance Concrete bridge deck pavement, we conducted Finite Element Method analysis with Incheon Grand Bridge constructed by SAMSUNG E&C. From the FEM results, a thickness of five centimeters of High Performance Concrete bridge deck pavement with micro-silica is considered as a resonable value compared with the conventional asphalt bridge deck pavement.

  • PDF

100, 120 MPa급 고강도 콘크리트 적용 바닥판 적정두께 결정을 위한 실험적 연구 (Experimental Study on the Determination of Optimum Thickness of RC Deck Slabs by 100, 120 MPa High-Strength Concrete)

  • 배재현;황훈희;박성용
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.38-45
    • /
    • 2018
  • Bridges are structures where safety must be ensured. Generally, the destruction mechanism of bridge deck shows punching shear. Lately, the high-strength concrete is often used to increase the lifespan of bridges. The benefits of using the high-strength concrete are that it increases the durability and strength. On the contrary, it reduces the cross-section of the bridges. This study suggested the optimal thickness of bridge deck with application of high-strength concrete and the study evaluated its structural performance experimentally. The evaluation result shows that 180 mm and 190 mm of thickness are optimal for 100 MPa and 120 MPa high-strength concrete bridge deck respectively.

일체형 보강판의 균열성장거동(I)-SIF의 수치해석 (Crack growth behavior in the lntegrally stiffened plates(1) -Numerical evaluation of SIF)

  • 이환우
    • 한국정밀공학회지
    • /
    • 제14권5호
    • /
    • pp.150-156
    • /
    • 1997
  • Three dimensional finite element analysis was conducted to estimate the effect of shape parameters (plate width and thickness) on the stress intensity factor for crack in the integrally stiffened plate. Analysis was done for width ratios of 0.5, 0.75, 1.0, 1.5, 2.0, 2.5, and thickness ratios of 2, 3, 4, 6. Based on these results, an empirical equation of geometry factor is formulated as a function of crack length and thickness ratio.

  • PDF