• Title/Summary/Keyword: thickness evaluation

Search Result 1,812, Processing Time 0.033 seconds

Quality Characteristics of the Hamburger Patties with Sea Tangle (Laminaria japonica) Powder and/or Cooked Rice (다시마 분말과 밥을 첨가한 햄버거 패티의 품질 특성)

  • Oh, Hyun-Kyung;Lim, Hyeon-Sook
    • Food Science of Animal Resources
    • /
    • v.31 no.4
    • /
    • pp.570-579
    • /
    • 2011
  • This study created hamburger patties by substituting a portion of the meat with sea tangle (Laminaria japonica) powder and/or cooked rice to reduce fat and calories and to add the functional components of the sea tangle. Four types of experimental patties were prepared: Control, L, LI, and LII. L was the patty with sea tangle powder substituted for 2.5% of the meat and LI and LII were patties with cooked rice containing sea tangle powder substituted for 25 or 50% of the meat. In all experimental patties, moisture content increased and crude fat and cholesterol content decreased, pH increased, and malondialdehyde concentration decreased compared to those in the control. The substitutions made the color of the patties darker with dimmed redness and amplified yellowness. The substitutions also made the cooking loss weight and diameter of the patties lessen but that of thickness increased. In the sensory evaluation, symmetry and color of the patties improved significantly by substituting sea tangle powder and/or cooked rice for meat, and no adverse effect on preference for the experimental patties and hamburgers was observed. Therefore, substituting sea tangle and/or cooked rice for a portion of the meat could be used to develop healthier patties without any adverse influence on preference or sensory evaluation.

Evaluation of Hydrogeologic Seal Capacity of Mudstone in the Yeongil Group, Pohang Basin, Korea: Focusing on Mercury Intrusion Capillary Pressure Analysis (포항분지 영일층군 이암층의 수리지질학적 차폐능 평가: 수은 모세관 압입 시험의 결과 분석을 중심으로)

  • Kim, Seon-Ok;Wang, Sookyun;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.53 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • Geological CO2 sequestration is a global warming response technology to limit atmospheric emissions by injecting CO2 captured on a large scale into deep geological formations. The presented results concern mineralogical and hydrogeological investigations (FE-SEM, XRD, XRF, and MICP) of mudstone samples from drilling cores of the Pohang basin, which is the research area for the first demonstration-scale CO2 storage project in Korea. They aim to identify the mineral properties of the mudstone constituting the caprock and to quantitatively evaluate the hydrogeologic sealing capacity that directly affects the stability and reliability of geological CO2 storage. Mineralogical analysis showed that the mudstone samples are mainly composed of quartz, K-feldspar, plagioclase and a small amount of pyrite, calcite, clay minerals, etc. Mercury intrusion capillary pressure analysis also showed that the samples generally had uniform particle configurations and pore distribution and there was no distinct correlation between the estimated porosity and air permeability. The allowable CO2 column heights based on the estimated pore-entry pressures and breakthrough pressures were found to be significantly higher than the thickness of the targeting CO2 injection layer. These results showed that the mudstone layers in the Yeongil group, Pohang basin, Korea have sufficient sealing capacity to suppress the leakage of CO2 injected during the demonstration-scale CO2 storage project. It should be noticed, however, that the applicability of results and analyses in this study is limited by the lack of available samples. For rigorous assessment of the sealing efficiency for geological CO2 storage operations, significant efforts on collection and multi-aspect evaluation for core samples over entire caprock formations should be accompanied.

Effect of Marbling Score on Carcass Grade Factors, Physico-chemical and Sensory Traits of M. Longissimus Dorsi in Hanwoo (근내지방도가 한우 도체등급 요인, 이화학적 특성 및 관능적 특성에 미치는 영향)

  • Lee, Jong-Moon;Choe, Ju-Hui;Jin, Hyune-Ju;Kim, Tae-Il;Park, Beom-Young;Hwang, Do-Yon;Koh, Kyung-Chul;Kim, Cheon-Jei;Hwang, Kyu-Seok
    • Food Science of Animal Resources
    • /
    • v.32 no.5
    • /
    • pp.659-668
    • /
    • 2012
  • The objective of this research was to investigate the effect of marbling scores on carcass grade factors, physico-chemical and sensory traits of Hanwoo. Data used in this study were collected from 73,316 carcasses obtained at the Nonghyup Seoul slaughterhouse in 2009 and 271 cuts of M. longissimusdorsi were analyzed to estimate beef qualities. As the marbling scores increased, backfat thickness was linearly increased (p<0.05) in cows (9.51 mm-14.69 mm) and steers (8.71 mm-14.23 mm). As the marbling scores increased, maturity of cows was increased and meat color, texture and quality grade improved for all genders. With increase of the marbling scores, crude fat contents (3.07%-26.70%), water holding capacity (52.09%-58.66%), $L^*$ value (34.08-41.97) were significantly increased (p<0.05) and Warner-Bratzler shear force was linearly decreased (p<0.05) from 8.58 kg to 2.60 kg. The increase of crude fat contents had the similar interval with the increase of marbling scores from 1 to 6 but it is sharply increased from marbling score 7. There was no difference observed on $pH_{24}$ (5.50-5.66), protein contents (19.57%-21.15%) among the marbling scores. Marbling score was significantly correlated with live weight (r=0.29) in cows, loineye area (r=0.35) in steer, and overall acceptability of panel scores (r=0.67) (p<0.01).

Comparison of Meat Quality Characteristics between Crossbreeds (돼지 품종의 교배조합간 육질특성 비교)

  • Oh, Ha-Sik;Kim, Hyun-Youl;Yang, Han-Sul;Lee, Jeong-Ill;Joo, Young-Kuk;Kim, Chul-Uk
    • Food Science of Animal Resources
    • /
    • v.28 no.2
    • /
    • pp.171-180
    • /
    • 2008
  • This study was conducted to investigate the meat quality characteristics of pork loin in 3 crossbred groups (30 pigs/group). The crossbreeds were LY female${\times}$D male, Y female${\times}$B male and L female${\times}$B male (L: Landrace, Y: Yorkshire, B: Berkshire, D: Duroc). Pork loins were collected from animals ($110{\times}120kg$ body weight) slaughtered in a commercial slaughter house and stored at $-3^{\circ}C$. Samples were analyzed for general composition, physico-chemical properties, meat and fat color, texture characteristics, sensory evaluation and fatty acid composition at 24 hrs postmortem, and TBARS (Thiobarbituric Acid Reactive Substances) values were determined at various storage times. The LYD pigs showed a higher back fat thickness than the YB and LB pigs. There were no significant differences in intramuscular fat, intermuscular fat, subcutaneous fat and springiness among the 3 crossbreeds. In addition, there were no significant differences in general composition, pH, drip loss, cooking loss and cooked sensory evaluation among the 3 crossbreeds (p>0.05). The shear force value of LB pork was significantly lower than other crossbreeds (p<0.05). Total heme pigment was significantly higher in YB pork compared to LYD and LB pork (p<0.05). The TBARS value of YB pork was significantly lower than that of LYD pork, except after the I day of storage (p>0.05). TBARS values increased significantly during storage for all three crossbreeds. The lightness (CIE L) of YB pork was significantly lower, while the redness (CIE a) was significantly higher in YB pork relative to the other crossbreeds. With regard to textural properties, the hardness and adhesiveness values were significantly lower in YB pork compared to LB pork. In fresh meat, the color of YB pork was significantly higher than the other breeds (p<0.05). The content of myristic acid (C14:0) was significantly lower, while the content of arachidonic acid (C20:4) was significantly higher in LB pork (p<0.05). These results show that the YB breed has the highest quality meat of the three crossbreeds.

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

A Study of Current Perception Threshold of Trigeminal Nerve after Tooth Implantation (치아임플란트 시술 후 삼차신경에서의 전류인지역치에 대한 연구)

  • Lim, Hyun-Dae;Lee, Jung-Hyun;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.187-200
    • /
    • 2007
  • This study attempted to contribute to the clinical application of implant operation by making a quantitative nerve examination using a neurometer for the evaluation of sensory disturbances that could be incurred after the implantation in the dental clinics, and it intended to establish an objective guideline in the evaluation of sensory nerve after the operation of implant. An inspection was performed with the frequencies of 2000Hz, 250 Hz and 5 Hz before and after the operations of tooth implant using $Neurometer^{(R)}$ CPT/C (Neurotron, Inc. Baltimore, Maryland, USA) for 44 patients who had performed an implant operation among the patients coming to Daejeon Sun Dental Hospital in 2006 and 30 people for control group. The measuring sites were maxillary nerve ending and mandibular nerve ending of trigeminal nerve according to the implant operating regions. The current perception threshold (CPT) by each nerve fiber was specifically responded under the electric stimulation of 2000 Hz in case of $A{\beta}$ fiber and of 250 Hz in case of $A{\delta}$ fiber and of 5Hz in case of C fiber. The CPT test could be performed to assess the damages of peripheral nerve in the trigeminal nerve area and it stimulated selective nerve fibers by generating the electricity of specific frequency in the peripheral nerve area. The nerve fibers with varied thickness were responsive selectively to the electric stimulation with different frequencies; accordingly, they applied the electric stimulation with different frequencies and the reaction threshold of $A{\beta},\;A{\delta}$ and C fibers selectively responsive to each electric current could be individually evaluated. In the assessment through the CPT, the increase and decrease of the CPT could be measured so that sensory disturbances such as hyperaesthesia or hypoaesthesia could be diagnosed. This study could obtain the following results after the assessment of the CPT before and after the implant operation. 1. In the assessment before and after the implant operation, the CPT in the frequencies of 2000 Hz, 250 Hz, 5 Hz for maxillary branch increased on the whole after the operation and the CPT for mandibular branch in the $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz )after the operation increased statistically significantly. 2. For the groups of patients with medically compromised or its subsequent medicinal prescription, there were no significant differences before and after the implant operation and for the control groups, significantly high CPT was shown after the implant operation in the left $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz). 3. In the comparison of the measured value of the CPT before the operation between the control group and the implant operation group, the latter group had a significantly high measured value of the CPT in the right $A{\beta}$-fiber(2000 Hz) and C-fiber(5 Hz) and there were significant differences in $A{\beta}$-fiber(2000 Hz) in the CPT assessment after the implant operation for the control group. 4. Male participants had higher CPT than female counterparts; however, there were no statistic significances. In the CPT evaluation before and after implant operation, there were no statistical differences in the male group while the right C-fiber(5 Hz) and left $A{\beta}$-fiber(2000Hz) were significantly high in the female group. 5. In the comparison between the group who complain sensory disturbance and the other group, the CPT increased on the whole in the former group, but there were no statistical significances. In the groups, whom there was an increase in VAS, the CPT after the implant operation in the right C-fiber(5 Hz) increased significantly; meanwhile, in case that the VAS mark was '0' before and after the operation, the CPT after the operation in the left $A{\beta}$-fiber(2000 Hz) increased significantly. This study suggested that the CPT measurements using $Neurometer^{(R)}$ CPT/C, provide useful information of objective and quantitative sensory disturbances for tooth implantation.

Major Characteristics Related to Eating Quality in Waxy Corn Hybrids (찰옥수수 교잡종의 식미관련 주요 특성)

  • Jung Tae wook;Kim Sun Lim;Moon Hyeon Gui;Son Beom Young;Kim Si Ju;Kim Soon Kwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.spc1
    • /
    • pp.152-160
    • /
    • 2005
  • This study was carried out to investigate selectable criteria in evaluating waxy corn $F_1$ hybrids for developing good eating quality waxy corn variety. The physicochemical property analysis of 6 waxy corn $F_1$ hybrids - Chalok1, Chalok2, Heugjeomchal, Yeonnongl, Chalok4, and Suwon45- showed a range of $11.2\~13.1\%$ for crude protein, $5.1\~6.0\%$ for crude fat, $91.8\~92.6\%$ for amylopectin, and $4.5\~6.6\%$ for free sugar content. The pericarp thickness which is one of the most important characteristics related to tenderness in waxy corn was ranged $34\~47{\mu}m$ in 4 waxy corn hybrids - Yeonnongl, Chalok4, Suwon45, and Heugjeomchal. On the other hand, it was ranged $64\~81{\mu}m$ in Chalok1 and Chalok2. The amylogram analysis by rapid visco analyzer showed that in fresh waxy corn hybrid (DAP25), all amylogram properties except setback were higher in Yeonnongl, Chalok4, and Suwon45 compared to those of Chalokl, Chnlok2, and Heugjeomchal. However, in matured waxy corn hybyids (DAP45), the result was the opposite - the amylogram properties were higher in Chalokl, Chalok2, and Heugjeomchal than those of Yeonnongl, Chalok4, and Suwon45. The texture analysis showed that gumminess, chewiness, and hardness increased dramatically with the time after the cooking in Chalokl and Beugjeomchal. On the other hand, these above pyoperties did not change as rapidly with the time in Yeonnongl, Chalok4, and Suwon45. Gumminess, chewiness, and hardness did not increase much within 6 hours after steamingr but increased significantly 32 hours after steaming. Therefore, we have reached a conclusion that texture analysis of cooked waxy corn should be carried out 6 hours after steaming. In the sensory evaluation, Yeonnongl, Chalok4, and Suwon45 revealed higher palatability -6.8, 7.1, and 6.9 respectively - than. that of Chnlokl, Chalok2, and Heugjeomchal. The palatability analysis of 6 waxy corn hybrids showed palatability positively correlating with free sugar content,100-kernel weight, kernel length, kernet width, and consistency, but negatively correlating with pericarp thickness, hardness, gumminess, and chewiness.

Characterization and Evaluation of Melanocortin 4 Receptor (MC4R) Gene Effect on Pork Quality Traits in Pigs (돼지 Melanocortin 4 Receptor (MC4R) 유전자의 육질연관성 분석)

  • Roh, Jung-Gun;Kim, Sang-Wook;Choi, Jung-Suk;Choi, Yang-Il;Kim, Jong-Joo;Choi, Bong-Hwan;Kim, Tae-Hun;Kim, Kwan-Suk
    • Journal of Animal Science and Technology
    • /
    • v.54 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • This study aimed to investigate the single nucleotide polymorphisms (SNPs) of the porcine MC4R gene and validate the effect of the MC4R genotype for marker assisted selection (MAS). Six amplicons were produced to analyze the entire base sequences of the porcine MC4R gene and six SNPs were detected (c.-780C>G, c.-135C>T, c.175C>T-Leu59Leu, c.707A>G-Arg236His, c.892A>G-Asp298Asn, and c.*430A>T). Linkage disequilibrium (LD) of the six SNPs was analyzed by performing haploid analysis. There was a perfect linkage disequilibrium in c.-780C>G, c.-135C>T, c.175C>T-Leu59Leu, c.707A>G-Arg236His, and c.*430A>T. Only the c.892A>G (Asp298Asn) SNP showed a very low LD with an $r^2$ value of 0.028 and the D' value of 0.348. As a result, the two SNPs-c.707A>G (Arg236His) and c.892A>G (Asp298Asn)-were selected to extract the genotype frequencies from the 5 pig breeds by using the polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) genotype analysis method. The SNP frequency of c.707A>G (Arg236His) indicated the presence of the A (His) allele only in Yorkshire, while the G allele was fixed in the KNP, Landrace, Berkshire, and Duroc. Association analysis was carried out in 484 pigs with the c.707A>G (Arg236His) SNP and the meat quality traits of four different pig cross populations: a significant association was noted in crude fat, sirloin moisture, meat color, and the degree of red and yellow coloration. The frequency of the c.892A>G(Asp298Asn) SNP genotype varied among the breeds; while Duroc showed the highest frequency of the A (Asn) allele, KNP showed the highest frequency of the G (Asp) allele. Association analysis was carried out in 1126 pigs with the c.892A>G (Asp298Asn) SNP and the meat quality traits of four pig populations: a highly significant linkage was noted in the back-fat thickness (P<0.002). It was found that the back-fat thickness was higher in individuals with the AA genotype than in those with the AG or GG genotype. Thus, in this study, we verified that the c.892A>G (Asp298Asn) SNP in the pig MC4R gene has a sufficient effect as a gene marker for MAS in Korean pork industry.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.