Processing math: 100%
  • Title/Summary/Keyword: thermoluminescence (TL)

Search Result 107, Processing Time 0.023 seconds

Detection Characteristics of Irradiated Aloe vera by the Analysis of PSL, TL and ESR (감마선 조사된 알로에 베라의 PSL, TL 및 ESR 검지 특성)

  • Kim Byeong-Keun;Lim Sang-Yong;Song Hyun-Pa;Yun Hye-Jeong;Kwon Joong-Ho;Kim Dong-Ho
    • Food Science and Preservation
    • /
    • v.13 no.1
    • /
    • pp.61-65
    • /
    • 2006
  • Photostimulated luminescence (PSL), thermoluminescence(TL) and electron spin resonance (ESR) analyses were conducted to detect irradiation treatment of aloe vera powder, which was gamma-irradiated at 1, 3, 5 and 7 kGy. The non-irradiated aloe vera powder indicated below 700 of photon count in PSL, whereas, irradiated at 1 kGy and more, it showed more than 5,000 photon counts, indicating that it is feasible to detect the irradiation of aloe vera powder through PSL In the result of TL, from the minerals of the samples that were irradiated at more than 1 kGy, TL glow curve was able to be seen at around 150C. As the quantity of irradiation goes up, the ratio of TL1andTL2 also increased in proportion to that of irradiation. In the result of ESR analysis, unspecific centeral ESR signal was could be seen. As the amount of irradiation on the samples increased to the level of R2=0.97, the signal intensity also rose similarly. In conclusion, the PSL, TL and ESR exhibited the typical signals induced by irradiation treatment and were able to successfully detect all of the irradiated aloe vera powder. In addition, we found a positive correlation between the intensity of ESR and TL signals and irradiation doses.

The Effects on Antioxidants for Improving to Radiation Resistance of LDPE (저밀도 폴리에틸렌의 내방사선성 향상을 위한 산화방지제 첨가효과)

  • Kim, Ki-Yup;Kim, Pyeong-Jong;Lee, Chung;Kim, Jin-Ah;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.457-460
    • /
    • 2004
  • Many of the physical and chemical properties of polymer materials can be altered by high energy radiation. In the present work the exposure to radiation of low density polyethylene(LDPE) included antioxidants was carried out at various doses up to 600kGy at a dose rate of 5kGy/hr in the presence of air at room temperature. The study of the irradiation effects on the material properties has been make by different methods in an integrated way. The experimental data indicate that the decomposition onset temperature(DOT), the crystallinity and the thermoluminescence(TL) with radiation dose. DOT, crystallinity and TL analysis from irradiated PE samples provides useful data for the characterization of radiation-induced oxidation effects on these samples.

  • PDF

Identification of Pre-pasteurization or Pre-irradiation Treatment in Frozen Crushed Garlic Commercially Available in Korean Market (시판 유통 중인 냉동 다진 마늘의 사전 살균 및 조사처리 여부 판별 모니터링)

  • Kim, Hyo-Young;Ahn, Jae-Jun;Kim, Gui-Ran;Jeong, Jin-Hwa;Park, Ki-Hwan;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1673-1681
    • /
    • 2013
  • Five different chopped frozen garlic products samples, three from Chinese and two from Korean origins being commercially available products in Korean market, were used to confirm their pre-pasteurization or pre-irradiation status by screening (direct epifluorescent filter technique/aerobic plate counts, DEFT/APC; electronic nose, E-nose; photostimulated luminescence, PSL) and identification (thermoluminescence, TL; electron spin resonance, ESR) techniques. Some parts of samples were gamma-irradiated at 1 kGy to be used as control samples in irradiation history identification. DEFT/APC and e-nose successfully showed distinct results between the domestic and imported samples. The PSL photon counts of all the unknown samples were less than 700 (negative), while most of 1 kGy-irradiated samples gave PSL photon counts more than 5,000 (positive). The domestic unknown samples produced the TL glow peaks after 300C or more, whereas the imported samples showed TL peaks at the range of 240250C. A clear TL glow peak was obtained from all irradiated samples at 150250C. The unknown samples of Chinese origin gave radiation-specific cellulose ESR signal that was not shown by domestic samples. A multiple step of applying the physical analytical methods is recommended for the effective identification of irradiation status on chopped frozen garlic products.

Luminescence Identification Characteristics for Irradiated Dried Fishery Products (조사처리한 건조수산품의 전처리 방법에 따른 Luminescence 판별 특성)

  • Kim, Moon-Young;Ahn, Jae-Jun;Kim, Gui-Ran;Kwak, Ji-Young;Park, Kun-Sang;Lee, Kyung-Jin;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.11
    • /
    • pp.1837-1842
    • /
    • 2013
  • Photostimulated luminescence (PSL) and thermoluminescence (TL) analyses were conducted for the detection of different gamma-irradiated dried fishes (mussel, squid, beka squid, mitra squid, plaice, and saury) at 0, 1, 5 and 10 kGy. For TL analysis, the contaminating silicate minerals were obtained by density separation or acid hydrolysis treatment. PSL determinations indicated that all the non-irradiated samples showed PSL photon counts/60 s (PCs) lower than 700 PCs (negative), but the irradiated mussel sample at 5 and 10 kGy were only possibility identified showing higher than 5000 PCs (positive). Irrespective of sample kinds and methods of mineral separation, all the non-irradiated samples showed TL glow curves in low-intensity with a maximum peak only after 250C. However, all the irradiated samples produced TL glow curves in high intensity with a maximum peak particularly in the temperature range of 1150250C. In conclusion, more distinguishable TL results [glow curve, TL ratio (TL1/TL2)] were obtained from the marker minerals separated by acid hydrolysis rather than density method.

Application of PSL-TL Combined Detection Method on irradiated Composite Seasoning Products and Spices (방사선 조사 복합조미식품과 향신료의 확인을 위한 PSL-TL의 적용)

  • Chung, Hyung-Wook;Park, Sung-Kug;Han, Sang-Bae;Choi, Dong-Mi;Lee, Dong-Ha
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.206-211
    • /
    • 2008
  • Photostimulated luminescence(PSL)-Thermoluminescence(TL) combined analysis was applied to detect whether composite seasoning products and spices were irradiated or not. Samples were irradiated with 60Co at 07 kGy. A total of 12 different samples(6 of composite seasoning products and 6 of spices) was examined. Depending on the PSL results, TL analysis was performed. In case of both PSL positive(5,000 counts) and intermediate(7005000 counts), TL analysis had to be performed to confirm the result of PSL. Using TL, the shape of the glow curve(Glow 1) made it possible to identify the irradiated samples. In addition, The TL glow ratio(Glow 1/Glow 2) obtained by normalization was less than 0.1 for the non-irradiated samples and 0.29 for irradiated ones, respectively.

Thermoluminescence and Photostimulated Luminescence of BaFBr:BaFBr:Eu2+ Phosphor (BaFBr:Eu2+ 형광체의 열발광 및 광자극발광 특성)

  • Doh, Sih-Hong;Seo, Hyo-Jin;Kang, Kab-Jung;Kim, Young-Kook;Kim, Do-Sung;Kim, Sung-Hwan;Kim, Chan-Jung;Lee, Byung-Hwa;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.301-308
    • /
    • 2002
  • BaFBr:Eu2+ phosphors were prepared, and the thermoluminescence(TL) and photostimulated luminescence(PSL) of the prepared phosphors were measured. Two glow peaks around 352 and 448 K are observed for x-ray irradiated BaFBr:Eu2+ phosphors, and the activation energy of the main glow peak(352 K) was about 0.96 eV. The spectral range of the PSL was 350450nm, and the activation energy of the trap giving rise to PSL was about 0.98 eV. The activation energy of the traps giving rise to TL is agreed to those giving rise to PSL within experimental error.

Detection Characteristics of TL, ESR and DNA Comet for Irradiated Soybeans (열발광, 전자스핀공명 및 DNA Comet 분석에 의한 대두의 방사선 조사 여부 검지 특성)

  • Lee, Eun-Young;Jeong, Jae-Young;Noh, Jung-Eun;Jo, Deok-Jo;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • The detection characteristics of gamma-irradiated (04kGy) soybeans produced in Korea and China were investigated by thermoluminescene (TL), electron spin resonance (ESR), and DNA comet assay. The TL glow curves were shown at around 200C for irradiated soybeans, while that at 280C for the non-irradiated one. The normalization with a re-irradiation step at 1 kGy could verify the above detection results. The Korean soybean showed higher glow curves than Chinese did. The ESR spectroscopy for husks of irradiated soybeans revealed specific signals (g = 2.02374, 1.98715) derived from cellulose radical, which intensities were proportional to irradiation does, with the higher peaks in Chinese sample than Korean one. The DNA comet for the non-irradiated sample showed no or little tails, while those for irradiated samples above 0.5 kGy were remarkably changed in their length, size, and concentration, thus resulting in distinguishing non-irradiated from irradiated samples. As a result, TL, ESR, and DNA comet determinations were found suitable for the detection of irradiated soybean at 0.5 kGy or more, and negligible differences were observed between Korean and Chinese origins in their detection characteristics.

Detection of Radiation Induced Markers in Oranges Imported from the United States of America (미국산 오렌지의 Radiation Induced Marker 검색)

  • 조덕조;권중호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Radiation induced markers were investigated for the detection of irradiated oranges imported from America. In the DNA comet assay, the non-irradiated and irradiated samples showed the comets with long tails in both seed and flesh. Though this tendency was maintained for 6 weeks, identification of non-irradiated or irradiated samples was impossible. In the thermoluminescence (TL) measurement, the non-irradiated samples revealed a glow curve with low intensity at about 280C, while the irradiated samples showed with higher intensity at around 180C. There were no remarkable changes in detection properties for 6 weeks after irradiation. The TL ratio of area for TL1 glow curve to TL2 was below 0.1 for the non-irradiated samples and 0.5 or more for the irradiated ones during storage. In the electron spin resonance (RSR) measurement, irradiated oranges showed an unspecific central signal in all parts (seed, flesh and peel), so the detection for radiation treatment of oranges was impossible. Based on the results, DNA comet assay and ESR were not useful for the detection, but TL was appropriate to search radiation induced markers of oranges during storage period. The detectable period during storage is confirmed by sensory evaluation.

Identification of Irradiated Seafood Cooking Drips Using Various Detection Methods (수산 자숙액의 방사선 조사 여부 판별 특성 연구)

  • Choi, Jong-Il;Kim, Yeon-Joo;Kim, Jae-Hun;Lee, Ju-Woon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.11
    • /
    • pp.1569-1574
    • /
    • 2011
  • In this study, the identification of the irradiated seafood cooking drips from Hizikia fusiformis, Enteroctopus dofleini and Thunnus thynnus was conducted. The physical detection methods used included photo-stimulated luminescence (PSL) and thermoluminescence (TL), and the chemical detection methods were hydrocarbons analysis. In the PSL study, all seafood cooking drip samples showed 260~510 photon counts; thus, the PSL method could not be used for the detection of irradiated seafood cooking drips. The TL method could be used for the detection of irradiated H. fusiformis and E. dofleini cooking drips. In both cooking drips, the shapes of the glow curves indicated a specific peak at 150C~250C, which made it possible to identify the irradiated samples. The hydrocarbons derived by gamma irradiation of T. thynnus cooking drip were not detected due to low concentration and inconsistent content of fatty acids in the untreated T. thynnus cooking drip.

Identification of Gamma Irradiation of Imported Spice

  • Choi, In-Duck;Kim, Byeong-Keun;Song, Hyun-Pa;Byun, Myung-Woo;Han, Sang-Bae;Suh, Chung-Sik;Kim, Dong-Ho
    • Preventive Nutrition and Food Science
    • /
    • v.9 no.4
    • /
    • pp.317-323
    • /
    • 2004
  • Photostimulated Luminescence (PSL), Electron Spin Resonance (ESR) and Thermoluminescence (TL) analysis were conducted to detect irradiation treatment of imported whole and ground spices. The screening by PSL detected no irradiation treatment, except un the ground thyme and bay leaves which exhibited photon counts in the intermediate level. Irradiation of the two spices was detected after irradiating them at 1.0, 3.0, 5.0 and 10.0 kGy, and then subjecting them to PSL analysis, which resulted in the significantly low photons of non-irradiated spices compared to that at 1.0 kGy, indicating that the photon counts varied depending on the amount of inorganic mineral debris in the spices. To confirm a successful detection by using PSL, ESR and TL methods, some spices were selected, irradiated at 5.0 and 10.0 kGy, and subjected to the detection methods. PSL identified the irradiated spices except the cassia, which showed very weak PSL sensitivity, but was identified by ESR analysis. Also, the ESR and TL exhibited the typical signals induced by irradiation treatment and were able to successfully detect all of the irradiated spices. In addition, we found a positive correlation between the intensity of ESR and TL signals and irradiation doses.