• 제목/요약/키워드: thermocouple

검색결과 360건 처리시간 0.043초

가압 분무실내 스프레이 충돌판에서 나타나는 비정상 열전달 측정에 관한 연구 (An Experimental Study on Unsteady Heat Transfer of Spray-Impinging Plate in a Pressurized Chamber)

  • 조창권;이열;구자예
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.60-67
    • /
    • 2000
  • An experimental investigation on transient heat transfer phenomena of impinging diesel-spray on a flat plate in a pressurized chamber is carried out. A diesel spray is injected from a single-hole nozzle and impinges to a heated flat plate in the chamber. A fast-response thermocouple installed in the top surface of the plate measures the transient variation of surface temperature of the plate under various conditions of the chamber pressures. Utilizing the semi-infinite model, the temporal variation of the heat flux on the plate is determined. Effects of various parameters, such as vertical distances between the nozzle and the plate, radial distances from the injection-axis, and the chamber pressures, on the heat flux characteristics of impinging diesel-spray are studied.

K형 열전대를 이용한 온도제어 시스템 구현 (Implementation of the Temperature Control System Using K-type Thermocouple)

  • 김정래
    • 한국컴퓨터정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.127-133
    • /
    • 2004
  • 본 연구에서 개발하고자 하는 기기는 K형 열전대를 이용하여 온도를 제어 할 수 있는 온도제어 시스템으로써, 안정된 전압 레귤레이터, 22Bit 디지털 변환기와 분해능이 22Bit로 이루어졌다. 미소 전압을 25배 증폭 할 수 있게 하였고, 0~1200도 사이의 온도를 DC 0.1V~DC 4.7V내에서 제어하도록 설계하였다. PIC16C74로 Micro-controller의 software와 hardware의 블록 다아이 그램을 고안하였으며, VFD기능과 Power Block간에 인터페이스가 가능하도록 구성하였다.

  • PDF

고성능 주사탐침열현미경 열전탐침 제작 (High Performance Thermoelectric Scanning Thermal Microscopy Probe Fabrication)

  • 김동립;김경태;권오명;박승호;최영기;이준식
    • 대한기계학회논문집A
    • /
    • 제29권11호
    • /
    • pp.1503-1508
    • /
    • 2005
  • Scanning Thermal Microscope (STU) has been known for its superior resolution for local temperature and thermal property measurement. However, commercially available STU probe which is the key component of SThM does not provide resolution enough to explore nanoscale thermal phenomena. Here, we developed a SThM probe fabrication process that can achieve spatial resolution around 50 m. The batch-fabricated probe has a thermocouple junction located at the end of the tip. The size of the thermocouple junction is around 200 m and the distance of the junction from the very end of the tip is 150 m. The probe is currently being used for nanoscale thermal probing of nano-material and nano device.

급속 삽입법에 의한 화염 내부 온도 분포 측정 (Temperature Measurement in Concentric Diffusion Flames by Rapid Insertion Technique)

  • 이교우;정영록;정종수
    • 한국연소학회지
    • /
    • 제4권2호
    • /
    • pp.75-83
    • /
    • 1999
  • The effect of temperature distributions on soot volume fraction in double-concentric diffusion flames have been investigated experimentally. Using fine thermocouple wires and a rapid insertion mechanism, we have measured temperature without the effect of soot particles attached to the thermocouple junction, which can lower the temperature signal about 100 K by increasing the heat loss from the junction by radiation. The temperature at the flame axis is higher in the double-concentric diffusion flames than in normal co-flow diffusion flames because of the inverse diffusion flame. However, it is almost the same as that at the periphery of normal flames, on which the inverse flame does not have an effect. Thus, the lower soot concentration found in the double-concentric diffusion flame can be explained by the effect of nitrogen diffusion from the central air jet.

  • PDF

급속 삽입범에 의한 동축 이중 확산화염 내부 온도 분포의 측정 (Measurement of Temperature in Double-concentric Diffusion Flames by Rapid Insertion Technique)

  • 정영록;남평우;이교우;정종수
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.231-240
    • /
    • 1999
  • The temperature distribution in double-concentric diffusion flames have been investigated experimentally by rapid insertion technique. Using a fine thermocouple and rapid insertion mechanism, the temperature has been measured before soot particles attach the thermocouple junction which can affect the temperature signal by changing the radiation heat loss. For double-concentric diffusion flames, the temperature at the axis is higher than that of normal coflow diffusion flames because of the inverse diffusion flame at the center of the flame. However, it is almost same at the periphery on which the inverse flame does not have an effect.

  • PDF

화염으로부터의 복사 열유속의 계측 I (A study on the measurement of Radiative Heat flux form the flame(I) -Design and Calibration of a Heat flux meter-)

  • 정종수;인종수;김승수
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.484-491
    • /
    • 1990
  • A heat-flux meter has been designed and manufactured to measure the heat flux from the flame. A calibration method of the heat-flux meter by a calibration furnace has also been proposed. The k-type (Chromel-Alumel) thermocouple material has been used as the material for the beat-flux meter. The electormotive force (e.m.f.) from the K-type thermocouple is shown to be linearly proportional to the heat flux absorbed. The characteristics of the heat-flux meter become better as the radius of heat absorbing disk becomes larger and its thickness thinner.

SiC 필라멘트를 이용한 소염 직전의 확산화염 온도 계측 (SiC filament Pyrometry in Near Extinction Diffusion Flame)

  • 심성훈;신현동
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1481-1487
    • /
    • 2002
  • The thin SiC filament technique has been employed to identify the possibility of measuring flame temperature, and especially unstable near-extinction flame temperature in an oxidizer deficient ambience, by comparing the relative visible (non-IR) luminosities of SiC filaments with thermocouple measured temperature in co-flowing, laminar propane/air diffusion flames. The results show good agreement between the digitized relative visible luminosity profiles of the SiC filaments and temperature profiles measured using a thermocouple at temperatures above $700^{\circ}C$, although, a non-linear calibration is probably required far the whole temperature range. The highest radial peak temperature exists near to the nozzle exit. and the centerline temperatures were virtually unchanged with increasing flame height in an oxidizer deficient near-extinction flame.

공작기계 고속이송용 리니어 모터의 열 특성에 관한 연구 (A study on thermal characteristics of linear motor for high speed machining tools)

  • 정일용;강은구;이석우;최헌종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.98-101
    • /
    • 2001
  • Linear motor feature a direct connection to the machine tool, therefore a direct route for heat transfer. The heat dissipation of linear motor machine is affected by the maximum temperature rise of the primary part, coil and the cooling method. To minimize temperature induced dimension changes and decrements of performance, linear motor machine require effective cooling mechanism. To evaluate cooling performance of existing linear motor machine, some experiments about temperature profile are performed using thermocouple recorder. Due to the lack of information about internal structure, only some finite element modeling is prepared and analyzed.

  • PDF