• Title/Summary/Keyword: thermocouple

Search Result 360, Processing Time 0.024 seconds

Creation of Consistent Burn Wounds: A Rat Model

  • Cai, Elijah Zhengyang;Ang, Chuan Han;Raju, Ashvin;Tan, Kong Bing;Hing, Eileen Chor Hoong;Loo, Yihua;Wong, Yong Chiat;Lee, Hanjing;Lim, Jane;Moochhala, Shabbir M.;Hauser, Charlotte A.E.;Lim, Thiam Chye
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.317-324
    • /
    • 2014
  • Background Burn infliction techniques are poorly described in rat models. An accurate study can only be achieved with wounds that are uniform in size and depth. We describe a simple reproducible method for creating consistent burn wounds in rats. Methods Ten male Sprague-Dawley rats were anesthetized and dorsum shaved. A 100 g cylindrical stainless-steel rod (1 cm diameter) was heated to $100^{\circ}C$ in boiling water. Temperature was monitored using a thermocouple. We performed two consecutive toe-pinch tests on different limbs to assess the depth of sedation. Burn infliction was limited to the loin. The skin was pulled upwards, away from the underlying viscera, creating a flat surface. The rod rested on its own weight for 5, 10, and 20 seconds at three different sites on each rat. Wounds were evaluated for size, morphology and depth. Results Average wound size was $0.9957cm^2$ (standard deviation [SD] 0.1845) (n=30). Wounds created with duration of 5 seconds were pale, with an indistinct margin of erythema. Wounds of 10 and 20 seconds were well-defined, uniformly brown with a rim of erythema. Average depths of tissue damage were 1.30 mm (SD 0.424), 2.35 mm (SD 0.071), and 2.60 mm (SD 0.283) for duration of 5, 10, 20 seconds respectively. Burn duration of 5 seconds resulted in full-thickness damage. Burn duration of 10 seconds and 20 seconds resulted in full-thickness damage, involving subjacent skeletal muscle. Conclusions This is a simple reproducible method for creating burn wounds consistent in size and depth in a rat burn model.

UHV Materials (초고진공계재료)

  • 박동수
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.24-24
    • /
    • 1998
  • 반도체장비를 포함하는 초고진공장비의 園훌化가 급속히 그리고 절실히 요구되고 있는 것이 현실정이다. 當面해서 실현할 국산진공장비의 대상은 廣範圍하다. 즉, 각종 진공 pump ( (rotary, dry, diffusion, cryo, ion, turbo melecular pump), 진공 chamber, 진공 line, gate valve 를 위 시 한 진공 V머ve, flange, gasket, fl않d야lU, mainpulater 퉁 진공 部品이 다. 진공계 의 핵심 은 適切하고 優良한 진공재료의 선태파 사용이다. 진공장비는 사용자가 원하는 진공도를 원하 는 시간 동안 륨空度를 유지해 주어야 한다. 진공재료 선태의 기준사항은:(1) 기체의 透過성 (2) 薰했훌 (3) 혔體放出특성 - -outgassing과 degassing- (4) 機械的 량훌度 (5) 온도 의존성 (6) 化學톡성 (7) 加I성 및 鎔接 성 (8) 課電특성 (9) 磁氣특성 (10) 高速함子 및 放射線 특성 (11) 經濟성 및 調達생 둥이 다. 우량한 초고진공계재료는 풍부하게 개발되어 왔고, 또 新材料들이 개발되고 있다. 여기에서는 주로 초고진공 내지는 극고진공계의 構造材料, 機能材料, 部品材料 일반파 몇가지 신재료의 특 성에 관해서 記述한다. M Mild SteeHSAE, 1112, 1010, 1020, 1022, etc)., S Stainless SteeHAlSI, 304, 304L, 310, 316, 321, 347): 구조재료, chamber, fl하1ges A Aluminum과 Alloys (1060, 1100, 2014, 4032, 6(뻐1): 구조재료, chamber, flanges, gaskets A AI, Al 떠loy는 SS에 代替하는 역 할올 시 작하고 있다. C Copper, Copper Alloys(C11$\alpha$)0, C26800, C61400, Cl7200): 내장인자, gasket, cryopanel, tubing T Titanium, Ziriconium, Haf띠um 및 Alloys: 특히 Ti은 10n pump 용 getter material 이 외 에 U UHV,XHV용 chamber계로서 관심올 끌고 있다. N Nickel, Nickel Alloys (200, 204, 211, monel, nichrome): 부식 방지 , 전자장치 , 자기 장치 귀 금속(Ag, Au, Pt, Pd, Rh, Ir, Os, Ru): 보조부품, gasket, filament, coating, thermocouple, 접 합부위 T TiC, SiC, zrC, HfC, TaC 둥의 탄화물과, BN, TiN, AlN 동의 질화물, 붕화물이 둥장하고 었 다. 유리: Soda Lime, Borosilicate, Potash Soda Lead: View Port, Chamber envelope C Ceramics: AlZ03, BeO, MgO, zrOz, SiOz, MgOzSiOz, 3Alz032SiOz, Z$textsc{k}$hSiOz S상N4: e electrical, thermal insulators, crucibles, boats, single crystals, sepctr려 windows 저자는 최근 저자들이 발견한 Zr-Ti-Cu-Ni-Be amorphous alloys coated cham뾰r가 radiation p proof로 이용될 수 있는 사실을 점검하고 었다 .. Z.Y. Hua 들은 Cs3Sb를 새로운 photocathode 재료로 보고하고 있다.

  • PDF

Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect (커튼월 이중 유리 외장재 파단에 대한 실험 및 수치해석 연구)

  • Nam, Jiwoo;Ryou, Hong-Sun;Kim, Dong-Joon;Kim, Sung-Won;Nam, Jun-Seok;Cho, Seongwook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.40-44
    • /
    • 2015
  • National and international standards for curtain wall glass are focused on wind pressure and insulation performance, but disasters such as fires and earthquakes are not considered. Failure of curtain wall glass during a fire in a skyscraper increases the loss of lives and property due to the spread of fire. Therefore, the fire resistance of curtain wall glass should be investigated, and technology to prevent glass failure should be developed to prevent fire damage due to spreading fire. It is important to predict the starting point of cracks and the cause of glass failure to prevent it effectively using the limited water in a skyscraper. In this study, double glazed glass was exposed to a radiator in an experiment performed to analyze the thermal characteristics. The results show that glass that was not directly exposed to high temperature and pressure was broken. To identify this failure case, numerical analysis was performed. Three glass specimens were installed in an ISO 9705 room and exposed to radiation using a radiator, and a thermocouple was used to measure the temperature on the surface of the glass. Widely used double glazed glass was analyzed for weakness to fire.

A STUDY ON THE PHYSICAL PROPERTIES OF RESTORATIVE MATERIALS FOR PHOTO-POLYMERIZATION OF ARGON LASER (아르곤 레이저를 이용한 광중합 수복재의 물리적 성질에 관한 연구)

  • Ju, Sang-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.368-382
    • /
    • 1998
  • The purpose of this study is to evaluate and compare the results of argon laser for 5 seconds, argon laser for 10 seconds, and visible light for 40 seconds photo-polymerization in compressive strength, microhardness, curing depth, temperature rising during polymerization, and polymerization shrinkage. Hybrid type composite resin(Z-100) and compomer(Dyract) were used to be compared. The compressive strength was measured by an Instron(1mm/min cross head speed) in 60 specimens and the microhardness of the surface was expressed by Vickers Hardness Number(VHN) in 30 specimens. The curing depth was evaluated comparing the different values of upper and lower VHN according to irradiation time and thickness for the light source polymerization in 60 specimens. The temperature rising during photopolymerization was observed by the temperature change with thermocouple sensitizer beneath 40 specimens at the argon laser for 10 seconds and visible light 40 seconds irradiation. The polymerization shinkage was evaluated by calculating the decrease of % volume by using a dilatometer in 30 specimens. The results were as follows ; 1. In the case of compressive strength, the argon laser polymerization groups were higher than visible light group in Z-100 (p<0.05). In Dyract, the argon laser 5 seconds group did not show a significant difference with the visible light 40 seconds group. The argon laser 10 seconds group showed the markedly low value when compared with other groups (p<0.05) 2. In microhardness, Z-100 was better than Dyract when comparing by VHNs (p<0.05); however, there was not a significant difference between two materials in the visible light 40 seconds group and the argon laser 10 seconds group. 3. In the study of curing depth, Z-100 showed the consistent polymerization in argon laser irradiation because there was no difference in the VHN decrease according to the thickness change. Over the thickness control, the results did not show a significant difference between visible light and argon laser group in Z-100; however, in the case of Dyract, the visible light 40 seconds group was better than the argon laser groups(p<0.05). 4. There was a significant difference between the two materials in temperature rising during polymerization (p<0.05), but not a significant difference between irradiation times, 5. There was not a significant difference between the two materials in polymerization shrink age. The argon laser 5 seconds group was smaller than the other groups (p<0.05). It could be concluded that Z-100 polymerization was recommended to use the argon laser for reduction of the irradiation time while Dyract was recommended to use the visible light polymerization.

  • PDF

ANALYSIS OF TEMPERATURE RISE ON THE ROOT SURFACE DURING CONTINUOUS WAVE OF CONDENSATION TECHNIQUE (Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석)

  • Kim, Young-Ju;Hwang, Yun-Chan;Kim, Sun-Ho;Hwang, In-Nam;Choi, Bo-Young;Jeong, Young-Jin;Juhng, Woo-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.341-347
    • /
    • 2003
  • This study was conducted to evaluate the temperature rise on the root surface while the root canal is being obturated using continuous wave of condensation technique. Maxillary central incisor was prepared for repeated canal obturation. Ten thermocouples (Omega Engineering Inc., Stanford, USA) were placed at 1 mm increment from the anatomical root apex. The real temperature of Buchanan plugger was recorded before insertion into the root canal. The root canal was obturated with continuous wave of condensation technique as described by Buchanan and the root surface temperature was recorded during obturation at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings of System B HeatSource (Model 1005, Analytic technologies, Redmond, WA, USA). After completion of the temperature recording, the dentinal-cementum thickness at each sites was measured. The data were analyzed using one-way ANOVA followed by Scheffe's test and linear regression test. The results were as follows. 1. When the temperature was set at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ on the digital display of System B HeatSource, the real temperature of the plugger at the 1mm point from the tip revealed $130.82{\pm}2.96^{\circ}C,{\;}158.00{\pm}5.26^{\circ}C,{\;}215.92{\pm}6.91^{\circ}C{\;}and{\;}249.88{\pm}3.65^{\circ}C$ respectively. 2. The position of 8 mm from the anatomical apex showed the highest temperature increase at each temperature settings and it was significantly higher than those of other positions (p<0.0l). The temperature rise was constantly increased toward coronal portion from apex of the root. 3. The maximum temperature increase on the root surface was $2.37{\pm}0.09^{\circ}C{\;}at{\;}150^{\circ}C{\;}setting,{\;}3.11{\pm}0.12^{\circ}C{\;}at{\;}200^{\circ}{\;}setting,{\;}3.93{\pm}0.09^{\circ}C{\;}at{\;}250^{\circ}C{\;}setting{\;}and{\;}5.69{\pm}0.15^{\circ}C{\;}at{\;}300^{\circ}C$ setting respectively. These results suggest that it be relatively kind to the supporting tissues of the root that the root canal is obturated using continuous wave of condensation technique at $150^{\circ}C,{\;}200^{\circ}C,{\;}250^{\circ}C{\;}and{\;}300^{\circ}C$ temperature settings on digital temperature display of System B HeatSource.

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is $1,201^{\circ}C$, maximum ambient temperature is $881^{\circ}C$, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

TEMPERATURE CHANGES IN THE PULP ACCORDING TO VAR10US RESTORATIVE MATERIALS AND BASES DURING POLISHING PROCEDURE (연마시 여러 가지 수복재와 이장재의 사용에 따른 치수내 온도변화)

  • Baik, Byeong-Ju;Lee, Doo-Cheol;Kim, Mi-Ra;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.3
    • /
    • pp.410-418
    • /
    • 2000
  • An in vitro study was performed to evaluate the effect of four variables on the temperature rise produced by polishing of restorations. The four variables were : restorative material, base, thickness of remaining dentin, continuous polishing or intermittent polishing. Class V cavities were cut on extracted molar and restored with composite resin, resin-modified glass ionomer cement, compomer, amalgam on the various bases (glass ionomer cement, zinc oxide eugenol cement, zinc phosphate cement) Dentin thickness under the restoration was 0.5mm, 1.5mm. Polishing was done with an aluminum oxide-coated disc. Polishing time was continuous or intermittent for up to 1 minute. Intra-pulpal temperature increased almost linearly in all cases. Amalgam produced highest temperature rises at the pulp, while the composite resin, resin-modified glass ionomer cement and compomer were not different for each other. The rate and extent of temperature rising of amalgam restoration was reduced by presence of a cement base. Zinc oxide eugenol cement bases showed the highest temperature rise, while glass ionomer cement, zinc phosphate cement were not different to the untreated tooth Thickness of remaining dentin was only significant for the amalgam restoration. Continuous polishing produced higher temperature rise than intermittent polishing.

  • PDF

The Investigation on the Optimum Culture Conditions and the Ice Nucleating Activity of Bacterium Xanthomonas translucens KCTC 2751 (Xanthomonas translucens KCTC 2751의 최적배양과 빙핵 활성 검토)

  • Kim, Young-Mun;Kang, Sung-Il;Jang, Young-Boo;Jun, Byung-Jin;Kong, Jai-Yul
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.249-255
    • /
    • 2006
  • The optimum culture conditions for the ice nucleating activity and the cell growth of Xanthomonas translucens KCTC 2751 were investigated. The optimum initial pH and temperature for the cell growth and the ice nucleating activity were 6.5 and $25^{\circ}C$, respectively. The optimum culture medium for the ice nucleating activity was composed of 1.0% maltose, 1.4% yeast extract, 0.8% digested of gelatin, and 0.03% KCI in distilled water. Freezing operations carried out on distilled water showed that the degrees of supercooling were $-7.90^{\circ}C$ without ice nucleators, $-1.56^{\circ}C$ with silver iodide as a commercial ice nucleator, and $-1.36^{\circ}C$ when Xanthomonas translucens KCTC 2751 were added. During progressive freeze-concentration assays, the addition of Xanthomonas translucens KCTC 2751 led to lower saccharose concentrations in the crystals, while the cells led to higher saccharose concetrations in the concentrated phase.

Salinity and Distribution of Zooplankton in the Estuarine System of Mankyong River and Dongjin River (만경 동진강 하구계의 동물플랑크톤의 분포와 염분)

  • 서해립;서호영
    • 한국해양학회지
    • /
    • v.26 no.3
    • /
    • pp.181-192
    • /
    • 1991
  • Zooplankton were sampled horizontally with a standard net from the surface layer of the estuarine system of Mankyong River and Dongjin River in October, 1989, March, May, and July, 1990. Among dominant taxa of the zooplankton community, copepods were predominant in October, 1989 and March, 1990 and Noctiluca scintillans in May and July, 1990. Abundance of zooplankton showed considerable spatial and temporal fluctuations with a range of $12~9,256ind./m^3$ in wet weight. In the copepod community, Pseudodiaptomus inopinus and Paracalanus inducus were predominant in October, 1989: Acartia hudosonica and P. inducus in March, 1990; A. hudosonica and Centropages abdoinalis in May, 1990; A. pacifica, P. indicus and Tortanus spinicaudatus in July. 1990. In summer (July),there were large seasonal changes in salinity ($0.7~28.9\textperthousand$), due to monsoonal flooding, and associated changes in community structured of copepods. There were eight species of copepods in the mixo-mesohaline zone ($5.0~28.8\textperthousand$), namely Acartia pacifica, A. hudosonica, Centropages tenuiremis, C. abdominalis, Labidocera Euchaeta, Tortanus spinicaudatus, corycaeus affinis and Paracalanus indicus. On the other hand, Thermocouple hyalinus, Pseudodiaptomus inopinus and Sinocalanus tenellus occurred in the mixo-oligohaline zone ($0.5~5.0\textperthousand$), showing more tolerant of low salinity than any of the other species. In the mixoeuhaline zone ($>28.0\textperthousand$), Labidocera bipinnata, Oithona similes, Calanus sinicus, Acartia omorii and Tortanus forcipatus were founded.

  • PDF

Changes in Body Temperature of Piglets in a Day (자돈의 일중 체온변화에 관한 연구)

  • Yi, One-Hyeon;Jeong, Wang-Yong;Lee, Sang-Cheol;Lee, Sang-Rak
    • Journal of Animal Environmental Science
    • /
    • v.18 no.2
    • /
    • pp.91-94
    • /
    • 2012
  • This study was conducted to develop an algorithm for determination of abnormal body temperature in piglets through skin and core temperature database at normal condition. 5 piglets (mean BW : 46 kg) were employed for the experiment. They were adapted in the individual metabolism cage set at $22.5{\pm}2.0^{\circ}C$ of room temperature for 2 weeks before the measurement of body temperature. Ear, neck, head and subcutaneous neck temperature (as core temperature) of piglets were measured for every 1 minute during 30 consecutive days through 1mm k-type thermocouple wire and NI-devices (National Instruments Corporation, Austin, Texas, USA). Body temperature data were accumulated and integrated into the 1 day unit. Change of daily mean skin and core body temperatures in piglets were lowest at around 06:00, highest at around 14:00 and gradually decreased until the day after 06:00. Each skin temperatures were varied with the measuring site and largely depended on the room temperature changes. Established database of skin and core body temperature in piglets through this study can be applied to develop an algorithm for monitoring and determining the abnormal condition of animal by using radio frequency identification.