• 제목/요약/키워드: thermal vacuum

검색결과 1,509건 처리시간 0.031초

진공차단부에서 발생하는 확산형 아크 수치해석 (Numerical Study on a Diffused-mode Arc within a Vacuum Interrupter)

  • 조성훈;황정훈;이종철;최명준;권중록;김윤제
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.479-482
    • /
    • 2008
  • In order to more closely examine the vacuum arc phenomena, it is necessary to predict the magnetohydrodynamic (MHD) characteristics by the multidisciplinary numerical modeling, which is coupled with the electromagnetic and hydrodynamic fields, simultaneously. In this study, the thermal-fluid characteristics of high current vacuum arcs were calculated by a commercial multiphysics package, ANSYS, in order to obtain Joule heat, Lorentz force and the interactions with flow variables. We assumed the diffused-mode arc within an AMF vacuum interrupter. It was found with four different currents that the temperature distributions on the anode surface are diffused uniformly without concentration in 7kA for both types (cup and coil-type). But the arc plasma transition and an increase of thermal flux density for increasing the applied current have caused the change of temperature distributions on the anode surface. We should need further studies on the two-way coupling method and radiation model for arc plasmas in order to accomplish the advanced analysis method for multiphysics.

  • PDF

소규모 반응로를 이용한 감압 잔사유지 연소실험 (The Experimental Studies of Vacuum Residue Combustion in a Small Scale Reactor)

  • 박호영;김영주;김태형;서상일
    • 에너지공학
    • /
    • 제14권4호
    • /
    • pp.268-276
    • /
    • 2005
  • 액체연료(중유)공급량 기준 20kg/hr규모의 반응로에서 증기분무 내부 혼합식 노즐을 이용하여 잔사유의 연소실험을 수행하였다. 본 실험에서 사용한 감압 잔사유는 점도가 높고 황함량, 잔류탄소와 금속성분의 함량도 높았다. 잔사유의 착화를 위해서는 반응로를 일정온도까지 예열하여야 했으며 이는 LPG를 이용하였다. 잔사유 공급량을 변화시키면서 축방향 및 반경방향의 로내 가스 온도, 주요 가스농도 및 채집된 고체 입자를 분석하였다. 잔사유의 주반응영역은 버너 팁으로부터 약 1 m 근방에서 형성되었으며 이는 축방향 가스 온도, 농도 분포 및 입자의 크기로부터 확인할 수 있었고, 반응로의 하류에서는 완전 확립된 온도분포를 보여주고 있었다. 고체 입자의 SEM 분석으로부터 잔류 탄소입자는 기공이 많은 형태를 띠고 있었다.

대용량 액체 수소 저장탱크를 위한 다층단열재의 단열성능 분석 (Adiabatic Performance of Layered Insulating Materials for Bulk LH2 Storage Tanks)

  • 김경호;신동환;김용찬;강상우
    • 한국수소및신에너지학회논문집
    • /
    • 제27권6호
    • /
    • pp.642-650
    • /
    • 2016
  • One of the most feasible solution for reducing the excessive energy consumption and carbon dioxide emission is usage of more efficient fuel such as hydrogen. As is well known, there are three viable technologies for storing hydrogen fuel: compressed gas, metal hydride absorption, and cryogenic liquid. In these technologies, the storage for liquid hydrogen has better energy density by weight than other storage methods. However, the cryogenic liquid storage has a significant disadvantage of boiling losses. That is, high performance of thermal insulation systems must be studied for reducing the boiling losses. This paper presents an experimental study on the effective thermal conductivities of the composite layered insulation with aerogel blankets($Cryogel^{(R)}$ Z and $Pyrogel^{(R)}$ XT-E) and Multi-layer insulation(MLI). The aerogel blankets are known as high porous materials and the good insulators within a soft vacuum range($10^{-3}{\sim}1$ Torr). Also, MLI is known as the best insulator within a high vacuum range(<$10^{-6}{\sim}10^{-3}$ Torr). A vertical axial cryogenic experimental apparatus was designed to investigate the thermal performance of the composite layered insulators under cryogenic conditions as well as consist of a cold mass tank, a heat absorber, annular vacuum space, and an insulators space. The composite insulators were laminated in the insulator space that height was 50 mm. In this study, the effective thermal conductivities of the materials were evaluated by measuring boil-off rate of liquid nitrogen and liquid argon in the cold mass tank.

Biased Thermal Stress 인가에 의한 TSV 용 Cu 확산방지막 Ti를 통한 Cu drift 측정

  • 서승호;진광선;이한결;이원준
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.179-179
    • /
    • 2011
  • 관통전극(TSV, Trough Silicon Via) 기술은 전자부품의 소형화, 고성능화, 생산성 향상을 이룰 수 있는 기술이다. Cu는 현재 배선 기술에 적용되고 있고 전기적 저항이 낮아서 TSV filling 재료로 사용된다. 하지만 확산 방지막에 의해 완벽히 감싸지지 않는다면, Cu+은 빠르게 절연막을 통과하여 Si 웨이퍼로 확산된다. 이런 현상은 절연막의 누설과 소자의 오동작 등의 신뢰성 문제를 일으킬 수 있다. 현재 TSV의 제조와 열 및 기계적 응력에 관한 연구는 활발히 진행되고 있으나 Biased-Thermal Stress(BTS) 조건하의 Cu 확산에 관한 연구는 활발하지 않는 것이 실정이다. 이를 위해 본 연구에서는 TSV용 Cu 확산 방지막 Ti에 대해 Cu+의 drift 억제 특성을 조사하였다. 실험을 위해 Cu/확산 방지막/Thermal oxide/n-type Si의 평판 구조를 제작하였고 확산 방지막의 두께에 따른 영향을 조사하기 위해 Ti의 두께를 10 nm에서 100 nm까지 변화하였으며 기존 Cu 배선 공정에서 사용되는 확산 방지막 Ta와 비교하였다. 그리고 Cu+의 drift 측정을 위해 Biased-Thermal Stress 조건(Thermal stress: $275^{\circ}C$, Bias stress: +2MV/cm)에서 Capacitance 및 Timedependent dielectric breakdown(TDDB)를 측정하였다. 그 결과 Time-To Failure(TTF)를 이용하여 Cu+의 drift를 측정할 수 있었으며, 확산 방지막의 두께가 증가할수록 TTF가 증가하였고 물질에 따라 TTF가 변화하였다. 따라서 평판 구조를 이용한 본 실험의 Cu+의 drift 측정 방법은 향후 TSV 구조에서도 적용 가능한 방법으로 생각된다.

  • PDF

Measurement of Hydroxyl Radical Density at Bio-Solutions Generated from the Atmospheric Pressure Non-Thermal Plasma Jet

  • Kim, Yong Hee;Hong, Young June;Uhm, Han Sub;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.494-494
    • /
    • 2013
  • Atmospheric pressure non-thermal plasma of the needle-typed interaction with aqueous solutions has received increasing attention for their biomedical applications [1]. In this context, surface discharges at bio-solutions were investigated experimentally. We have generated the non-thermal plasma jet bombarding the bio-solution surface by using an Ar gas flow and investigated the emission lines by OES (optical emission spectroscopy) [2]. Moreover, The non-thermal plasma interaction with bio-solutions has received increasing attention for their biomedical applications. So we researched, the OH radical density of various biological solutions in the surface by non-thermal plasma were investigated by Ar gases. The OH radical density of DI water; deionized water, DMEM Dulbecco's modified eagle medium, and PBS; 1x phosphate buffered saline by non-thermal plasma jet. It is noted that the OH radical density of DI water and DMEM are measured to be about $4.33{\times}1016cm-3$ and $2.18{\times}1016cm-3$, respectively, under Ar gas flow 250 sccm (standard cubic centimeter per minute) in this experiment. The OH radical density of buffer solution such as PBS has also been investigated and measured to be value of about $2.18{\times}1016cm-3$ by the ultraviolet optical absorption spectroscopy.

  • PDF

가열 전극 통합 채널 공진기의 진공 환경 구동에 의한 열물성 측정의 민감도 향상 (Sensitivity Enhancement for Thermophysical Properties Measurements via the Vacuum Operation of Heater-integrated Fluidic Resonators)

  • 고주희;이정철
    • 센서학회지
    • /
    • 제32권1호
    • /
    • pp.39-43
    • /
    • 2023
  • Microscale thermophysical property measurements of liquids have been developed considering the increasing interest in the thermal management of cooling systems and energy storage/transportation systems. To accurately predict the heat transfer performance, information on the thermal conductivity, heat capacity, and density is required. However, a simultaneous analysis of the thermophysical properties of small-volume liquids has rarely been considered. Recently, we proposed a new methodology to simultaneously analyze the aforementioned three intrinsic properties using heater-integrated fluidic resonators (HFRs) in an atmospheric pressure environment comprising a microchannel, resistive heater/thermometer, and mechanical resonator. Typically, the thermal conductivity and volumetric heat capacity are measured based on a temperature response resulting from heating using a resistive thermometer, and the specific heat capacity can be obtained from the volumetric heat capacity by using a resonance densitometer. In this study, we analyze methods to improve the thermophysical property measurement performance using HFRs, focusing on the effect of the ambience around the sensor. The analytical method is validated using a numerical analysis, whose results agree well with preliminary experimental results. In a vacuum environment, the thermal conductivity measurement performance is enhanced, except for the thermal conductivity range of most gases, and the sensitivity of the specific heat capacity measurement is enhanced owing to an increase in the time constant.

표면히터를 이용한 HAUSAT-2 위성 STM의 우주모사 및 열해석 검증 연구 (Space Simulation Test and Thermal Verification of HAUSAT-2 STM (Structural-Thermal Model) by Using Surface Heaters)

  • 이미현;김동운;황기룡;장영근
    • 한국항공우주학회지
    • /
    • 제33권11호
    • /
    • pp.106-114
    • /
    • 2005
  • 본 논문은 HAUSAT-2 위성의 구조-열모델(STM)에 대해 수행한 우주모사시험의 결과 및 이에 따른 열 모델링의 수정과 해석에 대한 연구 결과를 보여준다. 열 모델링의 보정은 시험 데이터와의 비교 분석 과정을 반복하여 이루어졌으며, 이러한 보정된 열 모델링을 통해 시험데이터와 근사한 결과를 재해석 시에 얻게 되었다. HAUSAT-2의 열진공 및 열평형 시험에서는 표면히터를 사용하여 태양광을 모사하였다. 본 열진공 및 열평형 시험을 통하여 소형 열진공 챔버 내에서 국내 최초로 초소형 위성 모델을 우주모사시험하기 위한 저비용이며 효율적인 열시험 방법을 제시하였고, 또한 이를 시험 결과를 통해 검증하였다.

모델 단순화에 의한 CFRP 복합 구조물의 유효 열전도율 추출 방법 연구 (STUDY ON A EFFECTIVE THERMAL CONDUCTIVITY OF THE CFRP COMPOSITE STRUCTURE BY A SIMPLIFIED MODEL)

  • 김동건;한국일;최준혁;이장준;김태국
    • 한국전산유체공학회지
    • /
    • 제20권4호
    • /
    • pp.63-69
    • /
    • 2015
  • The thermal balance test in vacuum chamber for satellite structures is an essential step in the process of satellite development. However, it is technically and economically difficult to fully replicate the space environment by using the vacuum chamber. To overcome these limitations, the thermal analysis through a computer simulation technique has been conducted. The CFRP composite material has attracted attention as satellite structures since it has advantages of excellent mechanical properties and light weight. However, the nonuniform nature of the thermal conductivity of the CFRP structure should be noted at the step of thermal analysis of the satellite. Two different approaches are studied for the thermal analyses; a detailed numerical modeling and a simplified model expressed by an effective thermal conductivity. In this paper, the effective thermal conductivities of the CFRP composite structures are extracted from the detailed numerical results to provide a practical thermal design data for the satellite fabricated with the CFRP composite structure. Calculation results of the surface temperature and the thermal conductivities along x, y, z directions show fairly good agreements between the detailed modeling and the simplified model for all the cases studied here.

칼코게나이드 유리반도체를 이용한 온도센서에 관한 연구 (A Study of Thermal Sensor Using Chalcogenide Classy Semiconductor)

  • 임석범;임동준;양준모;김영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.439-442
    • /
    • 2001
  • Chalcogenide glassy semiconductors(CGS) can be obtained by the melt quenching technique. We have investigated the thin film heterostructures : metal-chalcogenide glassy semiconductors, where metal is copper, and chalcogenide glassy semiconductors are glasses of the system As-Se. CU/CGS film heterostructure were produced in the vacuum evaporator by the method of vacuum thermal evaporation. Doped films are very sensitive to external actions, and this property allows developing supersensitive precision sensors of temperature, humidity, illumination, and etc. based on them. Cu/CGS film has shown that resistance strongly depend on the temperature. The ratio of resistance vs. temperature has shown over a 2 k$\Omega$/degree. The slop of temperature and resistance shows linear.

  • PDF

비정질 칼코게나이드 반도체를 이용한 박막온도센서 (Thin Film Thermal Sensor using Amorphous Chalcogenide Semiconductor)

  • 문형돈;임동준;김화영;소동석;이진민;조봉희;김영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.727-730
    • /
    • 2002
  • Chalcogenide glassy semiconductors(CGS) can be obtained by the melt quenching technique. We have investigated the thin film heterostructures : metal-chalcogenide glassy semiconductors, where metal is copper, and chalcogenide glassy semiconductors are glasses of the system As-Se. Cu/CGS film heterostructure were produced in the vacuum evaporator by the method of vacuum thermal evaporation. Doped films are very sensitive to external actions, and this property allows developing supersensitive precision sensors of temperature, humidity, illumination, and etc. based on them. Cu/CGS film has shown that resistance strongly depend on the temperature. The slop of temperature and resistance shows linear.

  • PDF