• 제목/요약/키워드: thermal stratification

검색결과 281건 처리시간 0.024초

기후변화에 따른 소양호 수온 및 성층강도 변화 예측 (Projection of water temperature and stratification strength with climate change in Soyanggang Reservoir in South Korea)

  • 윤여정;박형석;정세웅
    • 한국물환경학회지
    • /
    • 제35권3호
    • /
    • pp.234-247
    • /
    • 2019
  • In a deep lake and reservoir, thermal stratification is of great importance for characteristics of hydrodynamic mixing of the waterbody, and thereby influencesvertical distribution of dissolved oxygen, substances, nutrients, and the phytoplankton community. The purpose of this study, was to project the effect of a future climate change scenario on water temperature, stratification strength, and thermal stability in the Soyanggang Reservoir in the Han River basin of South Korea, using a suite of mathematical models; SWAT, HEC-ResSim, and CE-QUAL-W2(W2). W2 was calibrated with historical data observed 2005-2015. Using climate data generated by HadGEM2-AO with the RCP 4.5 scenario, SWAT predicted daily reservoir inflow 2016-2070, and HEC-ResSim simulated changes in reservoir discharge and water level, based on inflow and reservoir operation rules. Then, W2 was applied, to predict long-term continuous changes of water temperature, in the reservoir. As a result, the upper layer (5 m below water surface) and lower layer (5 m above bottom) water temperatures, were projected to rise $0.0191^{\circ}C/year$(p<0.05) and $0.008^{\circ}C/year$(p<0.05), respectively, in response to projected atmospheric temperature rise rate of $0.0279^{\circ}C/year$(p<0.05). Additionally, with increase of future temperature, stratification strength of the reservoir is projected to be stronger, and the number of the days when temperature difference of the upper layer and the lower layer becomes greater than $5^{\circ}C$, also increase. Increase of water temperature on the surface of the reservoir, affected seasonal growth rate of the algae community. In particular, the growth rate of cyanobacteria increased in spring, and early summer.

Analysis of the fluid-solid-thermal coupling of a pressurizer surge line under ocean conditions

  • Yu, Hang;Zhao, Xinwen;Fu, Shengwei;Zhu, Kang
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3732-3744
    • /
    • 2022
  • To investigate the effects of ocean conditions on the thermal stress and deformation caused by thermal stratification of a pressurizer surge line in a floating nuclear power plant (FNPP), the finite element simulation platform ANSYS Workbench is utilized to conduct the fluid-solid-thermal coupling transient analysis of the surge line under normal "wave-out" condition (no motion) and under ocean conditions (rolling and pitching), generating the transient response characteristics of temperature distribution, thermal stress and thermal deformation inside the surge line. By comparing the calculated results for the three motion conditions, it is found that ocean conditions can significantly improve the thermal stratification phenomenon within the surge line, but may also result in periodic oscillations in the temperature, thermal stress, and thermal deformation of the surge line. Parts of the surge line that are more susceptible to thermal fatigue damage or failure are determined. According to calculation results, the improvements are recommended for pipeline structure to reduce the effects of thermal oscillation caused by ocean conditions. The analysis method used in this study is beneficial for designing and optimizing the pipeline structure of a floating nuclear power plant, as well as for increasing its safety.

Analysis on the Circumference Wall Temperature in a Long Horizontal Pipe with Thermal Stratification

  • Ahn, Jang-Sun;Ko, Yong-Sang;Kim, Yu-Hwan;Park, Byeong-Ho;Kim, Eun-Kee
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.364-370
    • /
    • 1995
  • The One-dimensional fin model is used to analyze the angular wall temperature variation of long horizontal lines, where stratification could result in top-to-bottom differences in wall temperatures. The top and bottom sections are treated separately and coupled by boundary conditions. The thermal stratification analysis is focused on the effects of the heat transfer rates at the pipe surface. The results show that the heat transfer rate at the pipe surface is the controlling parameter which reduce significantly the temperature difference in pipe circumferential direction. The one-dimensional fin modelling analysis results are verified by comparison with the operating PWR test data. The circumferential temperatures of pipe calculated by one-dimensional fin modelling agree well with the PWR plant test data.

  • PDF

급속압축 장치를 이용한 불균일 예혼합기가 HCCI연소에 미치는 영향에 관한 연구 (An Investigation of HCCI Combustion Processes of Stratified Charge Mixture Using Rapid Compression Machine)

  • 임옥택
    • 한국자동차공학회논문집
    • /
    • 제17권3호
    • /
    • pp.8-14
    • /
    • 2009
  • Effect of heterogeneity of combustion chamber has been thought as one of the way to avoid dramatically generating heat in HCCI Combustion. The purpose of this research is to investigate the effect of heterogeneity, especially thermal stratification and fuel strength stratification on HCCI Combustion fueled with DME and n-Butane. Thermal stratification is formed in Combustion Chamber of Rapid Compression Machine with 3 Kinds of pre-mixture has different properties. The stratified charge mixture is adiabatic compressed and on that process, in cylinder gas pressure and two-dimensional chemiluminescence images are measured and analyzed.

진해ㆍ마산만의 성층화 및 DO 농도변화 (Stratification and DO Concentration Changes in Chinhae-Masan Bay)

  • 조홍연;채장원;전시영
    • 한국해안해양공학회지
    • /
    • 제14권4호
    • /
    • pp.295-307
    • /
    • 2002
  • 진해ㆍ마산만에서 수온, 염도 및 DO농도를 연직방향으로 1년동안 측정하였다. 관측된 수온 및 염도 자료를 이용하여 성층화 특성을 분석하고, DO농도의 연직변화를 성층화 특성 및 저질오염도와 관련하여 분석하였다. 분석결과, 진해ㆍ마산만의 수온 성층화는 4월 이전에 시작되어 10월경에 종료되는 양상을 보이고 있는 것으로 판단되었다. 또한, 1998년 4월 연직방향의 평균 염도변화는 3.9(equation omitted) 정도로 증가되고, 1998년 8월 9.3(equation omited), 10월 4.3(equation omitted) 정도가 유지되어 가을철에도 염도 성층이지속되고 있는 것으로 파악되었다. 한편, DO 농도는 성층화가 시작되는 4월을 기점으로 연직방향 평균 DO농도변화도 2.6(mg/L)에서 6월 8.3(mg/L), 8월 5.9(mg/L), 9월 7.24(mg/L), 10월4.4(mg/L)으로 명확한 성층화 양상을 보이고 있다. DO 농도변화는 전체적으로 해역의 오염도와 밀접한 관련이 있으나. 성층화 기간동안 연직방향 DO 농도편차가 크게 나타나고 있는것은 수온 및 염도성층에 의한 표 저층간의 물질교환 저해에 의한 영향도 직접적인 요인으로 작용하고 있은 것으로 파악되었다.

Feedwater Flowrate Estimation Based on the Two-step De-noising Using the Wavelet Analysis and an Autoassociative Neural Network

  • Gyunyoung Heo;Park, Seong-Soo;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.192-201
    • /
    • 1999
  • This paper proposes an improved signal processing strategy for accurate feedwater flowrate estimation in nuclear power plants. It is generally known that ∼2% thermal power errors occur due to fouling Phenomena in feedwater flowmeters. In the strategy Proposed, the noises included in feedwater flowrate signal are classified into rapidly varying noises and gradually varying noises according to the characteristics in a frequency domain. The estimation precision is enhanced by introducing a low pass filter with the wavelet analysis against rapidly varying noises, and an autoassociative neural network which takes charge of the correction of only gradually varying noises. The modified multivariate stratification sampling using the concept of time stratification and MAXIMIN criteria is developed to overcome the shortcoming of a general random sampling. In addition the multi-stage robust training method is developed to increase the quality and reliability of training signals. Some validations using the simulated data from a micro-simulator were carried out. In the validation tests, the proposed methodology removed both rapidly varying noises and gradually varying noises respectively in each de-noising step, and 5.54% root mean square errors of initial noisy signals were decreased to 0.674% after de-noising. These results indicate that it is possible to estimate the reactor thermal power more elaborately by adopting this strategy.

  • PDF

Multi Zone Modeling을 이용한 온도 성층화의 효과를 갖는 예혼합압축자기착화엔진의 압력상승률 저감에 대한 모사 (Effect of Thermal Stratification for Reducing Pressure Rise Rate in HCCI Combustion Based on Multi-zone Modeling)

  • 권오석;임옥택
    • 한국자동차공학회논문집
    • /
    • 제17권4호
    • /
    • pp.32-39
    • /
    • 2009
  • The HCCI engine is a next generation engine, with high efficiency and low emissions. The engine may be an alternative to SI and DI engines; however, HCCI's operating range is limited by an excessive rate of pressure rise during combustion and the resulting engine knock in high-load. The purpose of this study was to gain a understanding of the effect of only initial temperature and thermal stratification for reducing the pressure-rise rate in HCCI combustion. And we confirmed characteristics of combustion, knocking and emissions. The engine was fueled with Di-Methyl Ether. The computations were conducted using both a single-zone model and a multi-zone model by CHEMKIN and modified SENKIN.

열성층을 포함하는 원자력발전소 배관의 환경피로평가 (Environmental Fatigue Evaluation for Thermal Stratification Piping of Nuclear Power Plants)

  • 김태순;김규형
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.164-169
    • /
    • 2018
  • A detailed fatigue evaluation procedure was developed to mitigate the excessive conservativeness of the conventional environmental fatigue evaluation method for the pressurizer spray line elbow of domestic new nuclear power plants. The pressurizer spray line is made of austenitic stainless steel, which is relatively sensitive to the environmentally assisted fatigue, and has a low degree of design margin in terms of environmentally assisted fatigue due to the thermal stratification phenomenon on the pipe cross section as a whole or locally. In this study, to meet the environmental fatigue design requirements of the pressurizer spray line elbow, the new environmental fatigue evaluation has been performed, which used the ASME Code NB-3200-based detailed fatigue analysis and the environmental fatigue correction factor instead of the existing NB-3600 evaluation method. As a result, the design requirements for environmentally assisted fatigue were met in all parts of the pressurizer spray line elbow including the fatigue weakened zones by thermal stratification.

온도 성층화를 이용한 DME HCCI 엔진의 운전 영역 확장에 관한 수치해석 연구 (Prediction of the Viable Operating Range of DME Heel Engine Using Thermal Stratification Based on Numerical Analysis)

  • 정동원;권오석;백영순;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제20권4호
    • /
    • pp.344-351
    • /
    • 2009
  • A multi-zone model was used to predict the operating range of homogeneous charge compression ignition (HCCI) engine, the boundaries of the operating range were determined by knock (presented by ring intensity), misfire (presented by sensitivity of indicated mean effective pressure to the initial temperature). A HCCI engine fueled with Di-Methyl Ether (DME) was simulated under different initial temperature and equivalence ratios, and the operating range was well produced by the model. Furthermore, the model was applied to develop the operating range for thermal stratification in the preceding condition of initial temperature and equivalence ratios. The computations were conducted using Senkin application of the CHEMKINII kinetics rate code.

냉수가 수평유입되는 열저장탱크의 중간 경계면 부근에서의 열성층 효과 (Thermal Stratification Effects Near an Interface by Horizontal Inflow of Cold Water in Thermal Storage Tank)

  • 황성일;박이동
    • 태양에너지
    • /
    • 제8권2호
    • /
    • pp.46-56
    • /
    • 1988
  • This investigation concerns thermal stratification of the water due to the temperature difference (${\Delta}T=T_{\infty}-T_i$) between the mean temperature of the water in the test tank (1m wide, 1m high, 2.1m long) and the temperature of the inflow water into the tank; flow rate of circulating water and height of the sink diffuser in the test tank. The additional objectives was to observe a stratification phenomena near an interface by measuring the velosities and the temperature difference and investigate an availabilities of the better effective hot water through establishing thermocline near an interface around the bottom of the tank. Following results were obtained through the experiments. 1. When the flow rate was constant and the temperature difference (${\Delta}T=T_{\infty}-T_i$) between the mean temperature of the flow in the test tank and the temperature of the inflow water increased by 5.6, 9.5, 13.5($^{\circ}C$), obtained the better effective advantage of hot water and the stress near an interface increased gradually. 2. When the ${\Delta}T=T_{\infty}-T_i$ was constant and flow rate increased by 4.0, 4.8, 6.4, 8.0 (LPM), obtained the better effective advent age of hot water and the mean stress near an interface increased gradually. 3. When the height of the sink diffuser was 25cm from tank bottom in comparison with 50cm, obtained the better effective advantage of hot water and the mean stress near an interface increased.

  • PDF