• 제목/요약/키워드: thermal storage system

검색결과 651건 처리시간 0.024초

아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구 (Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System)

  • 이동원;김정배
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.30-35
    • /
    • 2011
  • 2중관형과 판형 열교환기에 에틸렌 클리콜-물 수용액으로 만들어진 아이스슬러리를 적용하는 경우의 유동 및 열적 특성을 규명하기 위하여 실험을 수행하였다. 아이스슬러리의 질량유속과 얼음 분율은 각각 800에서 3500 kg/$m^2s$과 0에서 25%이었다. 실험을 통해, 압력강하와 열전달율은 질량유속과 얼음 분율에 따라 증가하였다. 그러나 얼음 분율의 효과는 높은 질량유속 영역에서는 크지 않은 것으로 나타났다. 낮은 질량유속에서는 압력강하와 열전달율의 급속한 증가가 질량 유속에 관계되는 것으로 나타났다.

Analysis on the Effect of Thermal Performance with Various Load Patterns for Solar Hot Water Heating System

  • Kim, Byoung-Gi;Jang, Hwan-Young;Chung, Kyung-Taek;Suh, Jeong-Se
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.108-113
    • /
    • 2007
  • The performance of a solar water heater incorporating evacuated tubes was evaluated using a transient simulation program, TRNSYS. Simulations were performed for $60^{\circ}C$ of hot water load temperature and for 280 liter of daily hot water volumes and three 400 liter of storage tank volumes. Three patterns of daily hot water consumption profile were used in the present study (morning, lunch and evening). The results show that the increase in solar fraction depends on the load profile, as well as the collector efficiency coefficient. Hot water draw profile has a large effect on the performance of the SDHWS, the morning load profile has the highest solar fraction. The annual solar fraction of the system, at the weather conditions of Jinju is approximately 84% at lunch load pattern, the 280 kg of load volume, 400 kg of tank volume and the $60^{\circ}C$ of load temperature.

Characteristic of the Formation and Adhesion of Ice on a Cooling Surface by a Stirring Aqueous Solution

  • Kang, Chae-Dong;Seung, Hyun;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권3호
    • /
    • pp.110-117
    • /
    • 2006
  • Ice adhesion or cohesion leads to the decrease of the performance of ice making system, especially to dynamic type ice thermal storage system (DISS) which mainly forms ice from the flow of an aqueous solution. The ice adhesion is influenced by various parameters associated with operating or geometric condition. In this study, the influence on an adhesion of ice to the characteristic of cooling surface and to composition of an aqueous solution was fundamentally observed by using batch type cooling device,. a beaker. Three patterns of solution in each beaker were cooled with brine. Moreover, the characteristic of cooling surface on each beaker was distinguished to coating materials. Stirring power as a degree of the ice adhesion was measured. The stirring power to cooling heat transfer rate in each beaker was compared. As a result, the lowest stirring power of 8.9 W with non-adhesion of ice, was shown in the case of the aqueous solution of EG(4) + PG(1.5) + 1,6HD(1.5). in PE coating beaker.

B-KNO3 점화제의 가속 노화 특성 연구 (A Study on Acceleration Aging Characteristics of B-KNO3 Igniter)

  • 백종규;류병태;권미라
    • Korean Chemical Engineering Research
    • /
    • 제52권2호
    • /
    • pp.166-174
    • /
    • 2014
  • 본 연구에서는 점화제로 사용되는 $B-KNO_3$의 가속노화 실험에 따른 특성변화를 고찰하였다. 점화제는 보관 방법이나 보관기간에 따라 점화 효율이 저하되는 경향이 있으며 안정된 사용을 위해서는 이에 대한 명확한 이해가 필요하다. 따라서 노화에 대한 원인 규명을 위해 가속화 시험 시편의 미세구조와 결정구조 및 열분석을 수행하였으며 점화 특성에 끼치는 영향성을 규명하고자 하였다. 산화제로 첨가된 $KNO_3$의 결정구조를 분석함으로써 노화에 끼치는 산화제 영향을 해석하였다. 결론적으로 산화제의 결정구조가 안정한 구조로 변화되었으며 활성화 에너지변화에 영향을 끼쳤다.

BMS 정밀도 향상을 위한 셀 밸런싱용 션트 고정저항의 허용오차 저감 방법 (A Method of Reducing a Tolerance of a Shunt Resistor for Balance of the Battery Cell to Improve a Precision of BMS)

  • 김은민;손미라;강창룡
    • 전기학회논문지
    • /
    • 제67권8호
    • /
    • pp.1055-1061
    • /
    • 2018
  • Recently, due to the rapid development of electric vehicle and energy storage system, it is emphasized for battery management system to be needed and to be improved. BMS carries out various movement for optimization the use of the energy and safe use of secondary battery, these movement of BMS start at high wattage shunt fixed resistor which performs a function for detecting current among the BMS components. In addition, for the safe operation of secondary battery, the reliability of current voltage variation detected from shunt should be secured, and for corresponding characteristics, the quality of Temperature coefficient of resistance for BMS shunt and the quality of Thermo electromotive force all must be excellent. For these reasons, this study comes up with the stabilization plan for thermo electromotive force and temperature coefficient of resistance of BMS shunt resistor which is key to secondary battery operation.

건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석 (Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method)

  • 박재중;명제민;송두삼
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

투명 근적외선 흡수 염료 및 응용 분야 (Transparent Near-infrared Absorbing Dyes and Applications)

  • 정효철;정지은;이상호;김진철;박영일
    • 공업화학
    • /
    • 제34권3호
    • /
    • pp.207-212
    • /
    • 2023
  • 근적외선 흡수 염료는 전통적으로 정보 기록 및 정보 표시 분야에 사용되었을 뿐만 아니라 최근 광학 필터, 바이오, 에너지 저장 및 변환, 코팅 첨가제 등 다양한 응용 분야에 적용되고 있다. 핸드폰이나 디지털 카메라에 사용되는 이미지 센서는 근적외선 영역에서도 감도를 나타내기 때문에 보다 선명한 이미지를 구현하기 위해 근적외선 광학필터가 필수적이다. 에너지 저장 및 변환이 중요해짐에 따라 투명 태양 전지 분야에서는 근적외선 영역까지 흡수 영역을 확장할 수 있도록 다양한 근적외선 흡수 소재가 개발되고 있으며, 이를 이용해 소자 효율을 향상시키는 연구가 진행되고 있다. 미래 모빌리티 기술로 많은 관심을 받고 있는 자기치유 코팅 시스템에 광-열 효과를 갖는 근적외선 흡수 염료가 도입되어 보다 효율적인 자기치유 성능을 구현하는 연구들도 보고되고 있다. 본 총설에서는 대표적인 근적외선 흡수 염료들의 화학 구조들을 소개하고, 근적외선 흡수 염료들을 기반으로 한 최신 응용 연구 동향에 대해 다뤄보고자 한다.

Cook/Chill System에서의 고기완자 제조에 관한 연구 1. Herb를 이용한 고기완자의 제조 및 품질특성 (A Study on Preparation of Wanjajun for Cook/Chill System 1. Preparation of Wanjajun with Herb and Quality Characteristics)

  • 강은주;김선영;유정희
    • 한국식품영양과학회지
    • /
    • 제32권5호
    • /
    • pp.661-666
    • /
    • 2003
  • 단체급식에서의 cook/chill system을 위한 완자를 제조하되, 제조와 저장중에 일어 나는 이화학적 변화를 최소화시키는 완자를 제조하기 위하여 완자의 지방에 의한 화학적 변화를 지연시키고자 천연 항산화제인 허브를 2% 첨가하였다. 전통적인 방식인 pan-frying으로 기름온도 11$0^{\circ}C$에서 6분 이상 조리하여 내부온도가 74$^{\circ}C$ 이상이 되게 한 다음 냉장고에 넣어 내부온도가 3$^{\circ}C$가 되도록 냉각시킨 후에 비닐팩에 넣어 3$^{\circ}C$에서 8일간 냉장저장하면서 완자의 산화 양상을 조사하였다 완자의 조리, 저장 중 대조구에 비하여 허브를 첨가한 완자의 산가가 낮은 경향을 보였으며, 특히 sage 첨가구는 4.23 KOH mg/g으로 가장 낮은 산가를 나타냈다. 과산화물자도 sage 첨가구가 가장 낮은 산화양상을 나타냈고 (22.0 meq/kg) 다른 허브의 첨가구들도 대조구에 비하여 비슷하거나 낮은 경향을 보였다. TBA가는 rosemary/parsley/thyme 첨가구가 0.29 mgMA/kg으로 가장 낮았고, sage 및 basil/mints 첨가구도 비교적 낮은 경향을 보여 허브에 의해 산화반응이 지연되거나 산화생성물이 억제된 것으로 판단되었다. 또한 완자의 기호도를 조사한 결과 허브향 자체에 거부감이 없고 오히려 고기 특유의 냄새를 없애주는 것으로 나타나 추출물이 아닌 허브 자체의 천연 항산화제로의 활용 가능성은 물론 육제품의 관능성을 증진시킬 수 있었으며 SA>RPT>BM 처리구 순으로 효과적이었다.

플라즈마 충진 촉매 시스템을 이용한 에틸렌 저감 연구 (Decomposition of Ethylene using a Hybrid Catalyst-packed Bed Plasma Reactor System)

  • 이상백;조진오;장동룡;목영선
    • 한국대기환경학회지
    • /
    • 제30권6호
    • /
    • pp.577-585
    • /
    • 2014
  • A series of experiments using atmospheric-pressure non-thermal plasma coupled with transition metal catalysts were performed to remove ethylene from agricultural storage facilities. The non-thermal plasma was created by dielectric barrier discharge, which was in direct contact with the catalyst pellets. The transition metals such as Ag and $V_2O_5$ were supported on ${\gamma}-Al_2O_3$. The effect of catalyst type, specific input energy (SIE) and oxygen content on the removal of ethylene was examined to understand the behavior of the hybrid plasma-catalytic reactor system. With the other parameters kept constant, the plasma-catalytic activity for the removal of ethylene was in order of $V_2O_5/{\gamma}-Al_2O_3$ > $Ag/{\gamma}-Al_2O_3$ > ${\gamma}-Al_2O_3$ from high to low. Interestingly, the rate of plasma-catalytic ozone generation was in order of $V_2O_5/{\gamma}-Al_2O_3$ > ${\gamma}-Al_2O_3$ > $Ag/{\gamma}-Al_2O_3$, implying that the catalyst activation mechanisms by plasma are different for different catalysts. The results obtained by varying the oxygen content indicated that nitrogen-derived reactive species dominated the removal of ethylene under oxygen-lean condition, while ozone and oxygen atoms were mainly involved in the removal under oxygen-rich condition. When the plasma was coupled with $V_2O_5/{\gamma}-Al_2O_3$, nearly complete removal of ethylene was achieved at oxygen contents higher than 5% by volume (inlet ethylene: 250 ppm; gas flow rate: $1.0Lmin^{-1}$; SIE: ${\sim}355JL^{-1}$).

LMG 배관시스템의 열유동 해석 및 최적설계 프로그램 개발 (A Computer Programme Development for Thermal-Hydraulic Analysis and Optimal Design on LNG Pipeline System)

  • 이상규;홍성호;이중남;박석호
    • 한국가스학회지
    • /
    • 제4권2호
    • /
    • pp.7-14
    • /
    • 2000
  • 생산지로부터 LNG 선박으로 수송되어 각 생산기지의 저장탱크로 저장되는 액화천연가스 (LNG; Liquified Natural Gas)는 극저은인 Boiling Point보다 약간 낮은 온도 ($-162^{\circ}C$)로 전송된다. LNG 전송은 배관을 통하여 이루어지며, 이로 인하여 배관 내에는 2상 유동 (2-Phase Flow)이 자주 형성된다. 본 연구에서는 일차적으로 이러한 배관내의 2상 유동대한 압력강하량 계산법을 연구하였고, 단열재와 배관 표면을 통한 외부 열유입량과 그에 따른 BOG (Boil-off Gas) 발생량 계산 방법을 연구하여, 이들을 기반으로 LNG 배관시스템의 열유동 해석 프로그램을 개발하였다. 또한 본 연구 및 프로그램 개발을 토대로 최적의 단열재 두께와 배관 Size를 구할 수 있는 최적 설계 프로그램을 구축하였다. 이는 배관설계 시 주어진 최대 허용 압력 강하량과 BOG 발생량 등의 허용 운전 조건과, 단위 길이 당 배관가격과 단위 부피당 단열재가격을 기준으로 허용 범위 내의 최소 설비 비용을 찾는 최적 설계 방법이다.

  • PDF