• 제목/요약/키워드: thermal power Plant

검색결과 1,090건 처리시간 0.03초

타워용 태양열발전 시스템 흡수기 기술동향 (Technical Trend of Receiver for Solar Power Tower)

  • 김종규;김진수;이상남;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.161-164
    • /
    • 2008
  • For the development of solar thermal power tower plant from the early 80' to today, various kinds of receiver have been tested and evaluated. Most of 1st generation receiver used water/steam as a working fluid to operate steam turbine and now the first commercial solar power tower PS-10 also makes saturated steam. However, to increase thermal efficiency of storage system and to obtain practical use of solar energy, molten salt system have been used from THEMIS project in France at 1984. The Solar Tres plant of 17 MWe power generation will be constructed in Spain and have plan to operate 24 hours in summer. The air volumetric receiver system can be integrated with combined cycle of gas turbine and HRSG and also with steam turbine easily. Therefore, related researches to develop higher efficient solar power tower plant and to operate with stable are widely performed in the world.

  • PDF

대규모 태양열 발전시스템 기본설계 특성 분석 (Study on the Basic Design of Large Scale Solar Thermal Power Plant System)

  • 김종규;강용혁;김진수;이상남;유창균;윤환기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.576-579
    • /
    • 2006
  • This paper describes characteristics and procedure of the basic design of large scale solar thermal power plant system. The evaluation is based on the operating data of CESA-I, solar central receiver plant. In order to evaluate the solar irradiation on the receiver, it is necessary to calculate the amount of thermal energy consumption at steam turbine and storage system in the STPPS. Especially, it is need to take into account of the storage and operating time to design a plant efficiently. In addition, basic design is performed for the CESA-I using the software tool of THERMOFLEX program. Based on the results, It is at lowed to use the program to investigate detail performance of each units of the STPPS by varying the operating conditions.

  • PDF

Spread Patterns of Thermal Effluent Discharged From Young-Kwang Nuclear Power Plant Using Remote Sensing Data

  • Han J. G.;Yeon Y. K.;Chi K. H.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.331-335
    • /
    • 2004
  • This study is focused to analyze the movement of thermal effluent dischargeed from nuclear power plant by season, ebb and flow, and before and after foundation of tide embankment using thermal infrared band image of 28 scenes observed from Landsat from 1987 to 2004, which is the early stage of operation of young-kwang nuclear power plant. In diffusion of thermal effluent discharge by seasons, spring and summer is spreading further than autumn and winter. It is considered to distribute widely mixed with thermal effluent discharge and hot water, which is distributed naturally along the seaside. It is known the fact that tidal currents control the direction of diffusion of thermal effluent discharge by the change of ebb and flow. Namely, it is distributed widely on the Southwest direction along the seaside by tidal currents when ebb and, it is moved widely on the Northeast direction along the seaside by tidal current when flood. However, in the early stage of flood current, the mainstream of thermal effluent discharge is spread on Southwest direction and, the direction is changed on North­east way when the latter period of flood current. Similarly, in the early stage of ebb current, the mainstream of thermal effluent discharge is spread on Northeast direction and, the direction is changed on Southwest direction when the latter period of ebb current. As the result of comparing to the diffusion pattern of thermal effluent discharge before and after the foundation of seawall, discharged thermal effluent from the drain of plant by the foundation of dike is shown as curved circle pattern on Northeast to West direction from the ending portion of the seawall.

  • PDF

1000MW 보일러 프로세스의 모델링과 데이터 추출 및 시뮬레이션 (Simulation and Data Sampling Modelling for 1000MW Boiler Process)

  • 박두용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.301-302
    • /
    • 2007
  • Maximum power consumption was up to 6,228kW in the summer of 2007 due to steady development of industry as well as increased demand of individual. Twenty fossil-Fired Thermal Power Plant for 500MW were underconstructed at present. KEPRI(Korea Electric Power Research Institute) manage 'Development of Advanced Fossil-Fired Thermal Power Generation System' project to construct high efficient power plant of 1000MW capacity for preparing increased demand of power. Design of control logic and data sampling were explained and high efficient control logic was simulated in detail in 'The Development of Next Generation Power Plant Instrument and Control System'(sub-project of 'Development of Advanced Fossil-Fired Thermal Power Generation System' project).

  • PDF

복합화력 발전플랜트의 근사 최적 열설계 해석 (Approximate Optimum Thermal Design Analysis of Combined Cycle Power Plant)

  • 전용준;신흥태;이봉렬;김동섭;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.782-787
    • /
    • 2001
  • An optimum thermal design analysis of the combined cycle power plant with triple pressure heat recovery steam generator was performed by the numerical simulation. The optimum design module used in the paper is DNCONF, a function of IMSL Library, which is widly known as a method to search for the local optimum. The objective function to be minimized is the cost of total power plant including the steam turbine power enhancement premium. The result of this paper shows that the cost reduces if the design point of power plant becomes the local optimum, and many calculations at various initial conditions should be carried out to get the value near the global optimum.

  • PDF

Retrofit of Analog Boiler Control Systems with Digital Control Systems in a Thermal Power Plant

  • Park, Doo-Yong;Byun, Seung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1304-1308
    • /
    • 2005
  • This paper presents the case that the existing analog control systems were retrofitted with digital DCS(Distributed Control System)s for boiler unit in thermal power plant. Replacement of existing worn-out or obsolete analog control systems has been considered. Replacement of existing analog control systems with another analog control systems has lots of difficulties in maintaining the systems due to being out of stock. Due to those difficulties, existing analog control systems have been retrofitted with digital DCSs in many industrial sites. KEPRI(Korea Electric Power Research Institute) accomplished the project that retrofitted analog control systems with the developed DCSs for boiler unit in middle-scale coal-fired thermal power plant. The benefits of an upgrade to digital control include a increase of reliability due to system redundancy, ease of modifying the control logic and the parameters of function block, ease of maintenance due to available spare parts, improvement of information display, ease of modifying MMI(Man Machine Interface) displays, a increase in system availability, and improvement of control performance. This paper describes how to use the parameters of existing analog controllers, the implementation of digital PID controller, control system configuration for boiler unit in thermal power plant, some boiler control loops, control result during commissioning, and the comparison of boiler characteristic test data after retrofitting with the existing test data.

  • PDF

발전용 소재 단조기술 및 국내 단조업계 동향 (Recent Trend to the Forging Technology of Power Plant Components and Status of Forging Company)

  • 김정태;장희상;김동권;김영득;김동영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.38-41
    • /
    • 2007
  • The increase of $CO_2$ emission by increasing of fossil fuel usage has been understood a major cause of global warming. The supply of electric energy is heavily dependent on the massive thermal power and nuclear power plant before developing the renewable energy to supply the electric energy stably at a low price. The large and sound forged components of pressure vessel, turbine and generator are widely used in power plant such as wind power, hydroelectric power generation, nuclear power and thermal power plant. This paper is discussed the trend of manufacturing technology for pressure vessel and turbine to satisfy the required condition of utility company. It is also introduced a strategy of forging industry to cope with carbon tax.

  • PDF

인천화력 4호기 발전기용 주/부 제어기를 갖는 정지형 여자시스템 개발 (Development of Generator Excitation System with Main/Standby Controller in In-chun Thermal power plant #4)

  • 류호선;임익헌
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.407-410
    • /
    • 1999
  • Potential-source controlled excitation system had been developed for synchronous generator in In-Chun thermal power plant #4 by KEPRI. This paper describes the characteristics of Main/Standby control system employed analog, digital circuit devices (hybrid type) and 3 PCRs(Phase Controlled Rectifier)

  • PDF

화력발전소 보일러 드럼 수위 퍼지 제어 (Fuzzy control of drum level of boiler in thermal power plant)

  • 변승현;박두용;김은기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.195-198
    • /
    • 1996
  • The control objective of drum level of boiler in thermal power plant is to maintain drum level at constant setpoint regardless of disturbance such as main steam flow. The initial response of the drum level loop process is in a direction opposite to the final response. The drum level loop shows inverse response when the power is changed abruptly. We adopt fuzzy controller using knowledge base considering system dynamics for controlling drum level. Finally, the simulation result using the digital simulator for boiler system in Seoul Power Plant Unit 4 shows the validity of fuzzy controller.

  • PDF

동해 울진 원전 온배수배출구 주변 해역에서의 대형저서동물 군집구조 (Community Structure of Macrobenthos around the Thermal Discharge Area of the Uljin Nuclear Power Plant in the East Sea, Korea)

  • 권순현;유옥환;이형곤
    • Ocean and Polar Research
    • /
    • 제39권2호
    • /
    • pp.125-148
    • /
    • 2017
  • This study analyzed the community structure of macrobenthic organisms in the subtidal area suffering under the influence of thermal discharge from the Uljin nuclear power plant during 2012-2013 and reviewed the temporal change in the faunal composition of the macrobenthic community using data from previous studies since the start of the plant operation in 1989. A total of 319 species were collected in 2012-2013, with a mean density of $3,330ind./m^2$ and a mean biomass of $131.96g/m^2$. These results were similar to those obtained in 2006-2007. The dominant species were not different from each other before and after the power plant operations began, but the faunal density near the power plant drainage port was significantly higher compared to those densities obtained from other stations. Spiophanes bombyx and Polydora sp., which is known as a pollution indicator species, was dominant only in the drainage port area. The study area consisted of two subregions with different macrobenthic communities depending on the water depth, which was similar to the results of the 2006-2007 survey. The macrobenthic community structures before and after the operation of the power plant in the coastal area were not changed, but there were seasonal differences in the long-term macrobenthic community structure which were strongly related to the thermal discharge from the power plant.