• 제목/요약/키워드: thermal oscillation

검색결과 103건 처리시간 0.022초

모사된 미세중력장내 액체부유대에서의 Marangoni대류의 불안정성 (Marangoni Convection Instability of a Liquid Floating Zone in a Simulated Microgravity)

  • 이진호;이동진;전창덕
    • 대한기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.456-466
    • /
    • 1994
  • Experimental investigation was made to study the mechanism of fluid and thermal oscillation phenomena of surface-tension driven flow in a cylindrical liquid column heated from above which is the low-gravity floating zone simulated on earth. Hexadecane, octadecane, silicon oil (10cs), FC-40 and water are used as the test liquids. The onset of the oscillatory thermocapillary convection appears when Marangoni number exceeds its criteria value and is found to be due to the coupling among velocity and temperature field with the free surface deformation. The frequency of temperature oscillation decreases with increasing aspect ratio for a given diameter and Marangoni number and the oscillation level increases with Marangoni number. The flow pattern in the liquid column appears either as symmetric or asymmetric 3-D flow due to the oscillatory flow in the azimuthal direction. The free surface deformation also occurs either as symmetric or asymmetric mode and its frequency is consistent with those of flow and temperature oscillations. The amplitude of surface deformation also increases with Marangoni number.

가열된 평판위에 매달려 있는 액적의 음향공진에 의한 열 및 물질 전달 촉진에 관한 연구 (Heat and Mass Transfer Enhancement of a pendant droplet on heated horizontal surface by acoustic resonance)

  • 문종훈;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.335-340
    • /
    • 2005
  • Nonlinear and forced oscillations of supported viscous droplet were focused in the present study. The droplet has a free contact line with solid plate and inviscid fluid. Natural frequencies of a pendant droplet have been investigated experimentally by imposing the acoustic wave while the frequency is being increased at a fixed amplitude. The evaporation was observed at atmosphere pressure. The droplet was recorded throughout the entire evaporation process and transient variations of the volume was measured. The evaporation process of oscillating droplet with thermofoil has been also observed to investigate analyzing the resonance effect on the thermal characteristics of droplet. It is found that a pendant droplet shows the resonant behaviors at each mode similar to the theoretical analysis. During imposing the acoustic wave, the pendant droplet makes a rotating motion in its longitudinal axis which is a new shape oscillation mode. The evaporation rate of a pendant droplet at resonant frequency is significantly enhanced.

  • PDF

저경도 Poly(organosiloxane) Rubber Composite의 제조와 열전도 특성 (Preparation and Thermal Conductivity of Poly(organosiloxane) Rubber Composite with Low Hardness)

  • 강두환;여학규
    • 폴리머
    • /
    • 제29권2호
    • /
    • pp.161-165
    • /
    • 2005
  • Octamethylcyclotetrasiloxane$(D_4)$과 1,3,5-trimethyl-1,3,5-triphenylcyclotrisiloxane$(D_3^{MePh})$을 1,1,3,3,-tetramethyl-1,3-divinylsiloxane(MVS)과 평형중합시켜 dimethylsiloxane과 methylphenylsiloxane block unit를 갖는 $\alpha,\omega-vinyl$ poly(dimethyl-methylphenyl)siloxane prepolymer(VPMPS)를 제조하였으며 또한 $D_4$와 1,3,5-trimethyl-1,3,5-trifluoropropylcyclotrisiloxane $(D_3^{M3,F3P})$을 1,1,3,3-tetramethyldisiloxane과 평형중합시켜 dimethylsiloxane과 methyltrifluoropropyl siloxane block unit를 갖는 $\alpha,\omega-hydrogen$ poly(dimethyl-methyltrifluoropropyl)siloxane prepolymer(HPDMFS)를 제조하였다. VPMPS, HPDMFS, 열전도 필터 및 촉매를 고속교반기에 가하고 $130^{\circ}C$에서 컴파운딩하여 저경도 poly(organosiloxane) rubber를 제조하였으며 이의 가교밀도는 $115^{\circ}C$에서 oscillation rheometer를 이용하여 측정하였다. 열전도성 충전제로 구상 알루미나를 Horsfield's packing model에 따라 평균입자경의 분포를 조절하여 제조한 composite TC-POXR-2의 열전도도가 1.13 W/mK, 그리고 TC-POXR-4가 1.19 W/mK였으며 이는 단일입자경을 갖는 충전제를 가하여 제조한 경우보다 높은 열전도성을 나타내었다.

메로시아닌 색소 LB막의 온도영향에 의한 수정진동자 거동특성조사 (The Investigation on Merocyanine Dye of Thermal Behavior Using QCM)

  • 윤회찬;김정명;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.128-130
    • /
    • 2001
  • In this study, we investigate the deposition characteristics of merocyanine dye(MD) Langmuir-Blodgett(LB) film using quartz crystal microbalance (QCM). The MD optical system mixed with fatty acid was fabricated using LB method. And their optical characteristics were investigated using UV spectroscopy. The optical behavior of MD LB film was investigated asto thermal treatment. The resonant frequency and admittance was measured during dissociation of J-aggregate of MD LB film. As a result, it has been suggested that the J-aggregate dissociation in MD LB film by thermal treatment give rise to transformation of oscillation characteristics of quartz crystal.

  • PDF

CUPID 코드와 MARS 코드를 이용한 기기/계통 다중스케일 연계 해석 코드 구현 (COMPONENT AND SYSTEM MULTI-SCALE DIRECT-COUPLED CODE IMPLEMENTATION USING CUPID AND MARS CODES)

  • 박익규
    • 한국전산유체공학회지
    • /
    • 제21권3호
    • /
    • pp.89-97
    • /
    • 2016
  • In this study, direct code coupling, in which two codes share a single flow field, was conducted using 3-dimensional high resolution thermal hydraulics code, CUPID and 1-dimensional system analysis code, MARS. This approach provide the merit to use versatile capability of MARS for nuclear power plants and 3-dimensional T/H analysis capability of CUPID. Numerical Method to directly couple CUPID and MARS was described in this paper. The straight flow and manometer flow oscillation were calculated to verify conservation of coupled CUPID/MARS code in mass, momentum, and energy. This verification calculations indicates that the CUPID/MARS is coupled appropriately in numerical aspect and the coupled code can be applied to nuclear reactor thermal hydraulics after validation against integral transient experiments.

층류 동축류 제트화염에서의 화염진동에 관한 실험적 연구 (A Study on Self-excitations in Laminar Coflow Jet Flames)

  • 윤성환;박정;윤진한;길상인;권오붕
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.83-85
    • /
    • 2012
  • Experimental study in coflow jet flames has been conducted to investigate the effects of adding $N_2$, $CO_2$ and He to coflowing air-side in self-excitations. Differences in the behaviors between buoyancy-driven and diffusive-thermal self-excitations with similar frequency range are explored and discussed in laminar coflow jet flames.

  • PDF

주기적으로 분극반전된 $LiNbO_3$ 결정에서 광매개증폭 (Optical Parametric Oscillation in Periodically Poled Lithium Niobate Crystal)

  • Kim Hong-Gi;Cha Myeong-Sik;Lee Beom-Gu
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.222-223
    • /
    • 2001
  • Optical parametric oscillator(OPO) has been used to generate coherent and tunable laser source with birefringent phase-matching technique in various nonlinear materials. In birefringent phase-matching, the output wavelength is controlled with angle or temperature tuning of the refractive index. However these tuning methods have several limitations such as restriction of tuning wavelength due to reasonable angular and temperature tuning ranges, Poynting vector walk-off which limits the interaction length, and thermal stabilization time. (omitted)

  • PDF

식쌍성의 각운동량과 질량의 관계

  • 오규동
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.13-13
    • /
    • 1993
  • 245개의 식쌍성에 대한 각운동량과 질량과의 상관 관계를 조사하였다. 이러한 조사 결과 분리형 쌍성계는 Log H=1.40+0.98Log M의 관계를 보였다. 이러한 결과로 보아 분리형과 준분리형 사이의 질량교환에 따른 각운동량이 보전된다는 조건하에서 질량교환에 따른 공전주기 변화의 조건은 성립 할 수 없을 것이다. 한편 12개의 RS CVn형은 분리형으로 undersize Subgiant 형은 준분리형의 상관관계와 일치하는 것으로 나타났다. 한편 접촉형은 분리형과 준분리형 사이에 나타나는 것으로 보아 Lucy와 Robertson and Eggleton등이 제시하는 것은 TRO(thermal relaxtion oscillation)이론에 따른 결과로도 해석 할 수 있을 것이다.

  • PDF

진공조에 위치한 1차 SQUID 미분계를 이용한 헬멧형 뇌자도 장치의 제작 (A Helmet-type MEG System with $1^{st}$ order SQUID Gradiometer Located in Vacuum)

  • 유권규;김기웅;이용호
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.78-82
    • /
    • 2009
  • We have fabricated a helmet type magnetoencephalogrphy(MEG) with a $1^{st}$ order gradiometer in vacuum to improve the signal-to-noise ratio(SNR) and the boil-off rate of liquid helium(LHe). The axial type first-order gradiometer was fabricated with a double relaxation oscillation SQUID(DROS) sensor which was directly connected with a pickup coil. The neck space of LHe dewar was made to be smaller than that of a conventional dewar, but the LHe boil-off ratio appeared to increase. To reduce the temperature of low Tc SQUID sensor and pickup coil to 9 K, a metal shield made of, such as copper, brass or aluminum, have been usually used for thermal transmission. But the metal shield exhibited high thermal noise and eddy current fluctuation. We quantified the thermal noise and the eddy current fluctuation of metal. In this experiment, we used the bobbin which was made of an alumina to wind Nb superconductive wire for pickup coil and the average noise of coil-in-vacuum type MEG system was $3.5fT/Hz^{1/2}$. Finally, we measured the auditory evoked signal to prove the reliability of coil-in-vacuum type MEG system.

  • PDF

Local Flow Speed Measurement Using Tunable AC Thermal Anemometry

  • Chung Won Seok;Kwon Ohmyoung;Lee Joon Sik;Choi Young Ki;Park Seungho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1449-1459
    • /
    • 2005
  • This paper shows the results of local flow speed measurement using tunable AC thermal anemometry, which is suitable for the accurate measurement of wide range flow speed. The measurement accuracy is verified through the comparison between the measurement data and the analytic solution of the sensor temperature oscillation in stationary fluid. The relation between the phase lag and the flow speed is experimentally investigated at various conditions. The measurement sensitivity for low flow speed improves in a low frequency region and that for high flow speed improves in a high frequency region. Also, the sensitivity increases with decreasing thermal conductivity of the surrounding fluid. The local flow speed could be measured as low as 1.5 mm/s and the highest measurement resolution was 0.05 mm/s in the range of 4.5 $\~$5.0 mm/s at 1 Hz in this experiment.