• 제목/요약/키워드: thermal line sensor

검색결과 47건 처리시간 0.034초

과전류 및 단락사고 방지용 전기안전 제어장치에 관한 연구 (A Study on Electric Safety Control Device for Prevention of Over Current and Short Circuit Faults)

  • 조시환;곽동걸;정도영;심재선;김정숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2100-2101
    • /
    • 2008
  • This paper is studied on a protective control system for electrical fire and electrical faults due to over current or electric short circuit faults by using electrical thermal characteristics of PTC (Positive Temperature Coefficient) thermistor and current response characteristics of high sensitive reed switch. The PTC thermistor has characteristic of positive resistivity temperature coefficient according to the temperature variation, which is construction of a regular square and cube demarcation with BaTiO3_Ceramics of positive temperature coefficient. Also PTC thermistor shows the phenomenon which is rapidly increased in the resistivity if the temperature is increased over Curie temperature point, and reed switch, which is used for electrical fault current sensing devices, have a excellent characteristic of response velocity in degree of ${\mu}s{\sim}ms$ that sensing magnetic flux in proportion to dimension of line current. This paper is proposed on a protective control system use PTC thermistor and reed switch for sensor which is protected from electrical fire due to overload faults or electric short circuit faults. Some experimental results of the proposed electric safety control device are confirmed to the validity of the analytical results.

  • PDF

지중 열전도도 측정을 위한 광섬유 센서의 건전성 (Integrity of Optical Fiber Sensor for Measurement of Ground Thermal Conductivity)

  • 윤석;최정찬;이승래;리 마이클 명섭
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.157-160
    • /
    • 2011
  • 본 연구에서는 광섬유 센서 기반 스마트 모니터링 시스템이 지중 열전도도 측정에도 효율적으로 적용될 수 있는지를 분석하였다. 이를 위해 광섬유 온도센서를 이용하여 지반의 열전도도를 측정할 수 있는 열응답 시험기가 개발되었다. 개발된 열응답 시험기는 기존의 RTD(Resistance Temperature Detector) 온도 센서 외에 광섬유 센서의 한 종류인 FBG(Fiber Bragg Grating) 센서도 실시간적으로 측정할 수 있는 시스템으로 구성되어 있다. 개발된 장비의 적용성 검증을 위하여 주문진 표준사를 이용하여 모형토조 내에 일정한 간극비에 맞추어 시료가 조성되었으며 지중열교환기는 U자형 파이프가 사용되었다. 20시간동안 열응답 시험을 통하여 광섬유 센서와 RTD 센서를 동시에 이용하여 온도값을 측정하여 표준사의 열전도도 값을 산출하였다. 그 결과 모형실험을 통한 열전도도 값은 탐침법을 통해 얻어진 열전도도 값과 선형 열원 모델(line source model) 해석해와 거의 유사하게 나타났으며 광섬유 센서와 RTD 센서와의 온도차는 0.1~0.3$^{\circ}$로써 유사한 값을 나타내었다. 따라서 본 연구에서 개발된 광섬유 기반 열응답 시험기는 지반의 열전도도를 측정하는데 효과적으로 사용될 수 있음을 알 수 있었으며 향후 지열시스템 가동에 따른 지중열 교환기의 손상도 평가 및 경보시스템 개발을 위해 지중열교환기의 거동을 실시간으로 모니터링 하는데 있어서도 효과적으로 사용될 수 있을 것으로 생각된다.

  • PDF

초고온 MEMS용 단결정 3C-SiC의 Ohmic Contact 형성 (Ohmic contact formation of single crystalline 3C-SiC for high temperature MEMS applications)

  • 정귀상;정수용
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.131-135
    • /
    • 2005
  • This paper describes the ohmic contact formation of single crystalline 3C-SiC thin films heteroepitaxially grown on Si(001) wafers. In this work, a TiW (Titanium-tungsten) film as a contact matieral was deposited by RF magnetron sputter and annealed with the vacuum and RTA (rapid thermal anneal) process respectively. Contact resistivities between the TiW film and the n-type 3C-SiC substrate were measured by the C-TLM (circular transmission line model) method. The contact phases and interface the TiW/3C-SiC were evaulated with XRD (X-ray diffraction), SEM (scanning electron microscope) and AES (Auger electron spectroscopy) depth-profiles, respectively. The TiW film annealed at $1000^{\circ}C$ for 45 sec with the RTA play am important role in formation of ohmic contact with the 3C-SiC substrate and the contact resistance is less than $4.62{\times}10^{-4}{\Omega}{\cdot}cm^{2}$. Moreover, the inter-diffusion at TiW/3C-SiC interface was not generated during before and after annealing, and kept stable state. Therefore, the ohmic contact formation technology of single crystalline 3C-SiC using the TiW film is very suitable for high temperature MEMS applications.

파우더와 솔더를 이용한 저비용 비아홀 채움 공정 (Low Cost Via-Hole Filling Process Using Powder and Solder)

  • 홍표환;공대영;남재우;이종현;조찬섭;김봉환
    • 센서학회지
    • /
    • 제22권2호
    • /
    • pp.130-135
    • /
    • 2013
  • This study proposed a noble process to fabricate TSV (Through Silicon Via) structure which has lower cost, shorter production time, and more simple fabrication process than plating method. In order to produce the via holes, the Si wafer was etched by a DRIE (Deep Reactive Ion Etching) process. The via hole was $100{\mu}m$ in diameter and $400{\mu}m$ in depth. A dielectric layer of $SiO_2$ was formed by thermal oxidation on the front side wafer and via hole side wall. An adhesion layer of Ti and a seed layer of Au were deposited. Soldering process was applied to fill the via holes with solder paste and metal powder. When the solder paste was used as via hole metal line, sintering state and electrical properties were excellent. However, electrical connection was poor due to occurrence of many voids. In the case of metal powder, voids were reduced but sintering state and electrical properties were bad. We tried the via hole filling process by using mixing solder paste and metal powder. As a consequence, it was confirmed that mixing rate of solder paste (4) : metal powder (3) was excellent electrical characteristics.

Development of the Infrared Space Telescope, MIRIS

  • 한원용;이대희;박영식;정웅섭;이창희;남욱원;문봉곤;박성준;차상목;표정현;박장현;가능현;선광일;이덕행;이성우;박종오;이형목
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.64.1-64.1
    • /
    • 2011
  • MIRIS (Multipurpose Infra-Red Imaging System), is a small infrared space telescope which is being developed by KASI, as the main payload of Science and Technology Satellite 3 (STSAT-3). Two wideband filters (I and H) of the MIRIS enables us to study the cosmic infrared background by detecting the absolute background brightness. The narrow band filter for Paschen ${\alpha}$ emission line observation will be employed to survey the Galactic plane for the study of warm ionized medium and interstellar turbulence. The opto-mechanical design of the MIRIS is optimized to operate around 200K for the telescope, and the cryogenic temperature around 90K for the sensor in the orbit, by using passive and active cooling technique, respectively. The engineering and qualification model of the MIRIS has been fabricated and successfully passed various environmental tests, including thermal, vacuum, vibration and shock tests. The flight model was also assembled and is in the process of system optimization to be launched in 2012 by a Russian rocket. The mission operation scenario and the data reduction software is now being developed. After the successful mission of FIMS (the main payload of STSAT-1), MIRIS is the second Korean space telescope, and will be an important step towards the future of Korean space astronomy.

  • PDF

KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구 (A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards)

  • 이병설;최충석
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.63-72
    • /
    • 2017
  • 본 논문에서는 저압용 10회로 분전반을 전기공업협동조합(KEMC) 2102-610 규정에 근거하여 제작하였다. 또한, 개발된 10회로 분전반의 특성 평가를 실시하여 안전성을 확보하고자 한다. 개발된 10회로 분전반은 내식성, 절연 재료의 특성, 자외선 복사의 내성, 기계적 충격 등에 적합하도록 설계되었다. 개발된 분전반은 외함의 보호 등급, 감전방지와 보호회로, 개폐 장치와 구성품, 내부 전기 회로와 연결부, 외부 도체의 단자, 절연 특성, 온도 상승 시험, 열저항 등이 적합하도록 제작하였다. 개발된 10회로 분전반은 단상 회로와 3상 회로 등으로 구분되어 있다. 분기된 각각의 차단기 부하측에 센서 모듈을 설치하여 부하의 전선로에서 발생되는 누설전류의 크기를 실시간 측정할 수 있다. 그리고 부하의 용도 및 목적 등에 따라 회로를 증설할 수 있고, 각각의 부하 상태 역시 실시간 부하 관리 및 점검이 가능하다. 개발된 10회로 분전반의 온도 상승 시험을 실시한 곳은 인입 접속부, 주회로 및 분기회로 모선, 모선지지물 등 18 개소이다. 온도가 가장 높게 측정된 곳은 분기회로 모선용 MCCB 전원측 접속부의 R-phase으로 $65.3^{\circ}C$, 부하측은 T-phase으로 $61.6^{\circ}C$로 기록되었다. 그리고 내열 실험 장치를 이용하여 MCCB를 $180^{\circ}C$에서 6시간 동안 열적 스트레스를 인가하였을 때 작동 손잡이의 변형이 확인되었고, 트립 상태로 이동한 것이 확인되었다.

흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석 (An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam)

  • 오석훈;서백수;김중열
    • 한국지구과학회지
    • /
    • 제31권6호
    • /
    • pp.563-572
    • /
    • 2010
  • 흙댐에서의 누수 구역을 판별하기 위해 다채널 연속 온도 모니터링을 수행하고 이를 검증하기 위해 전기비저항 물리탐사를 함께 수행하였다. 일반적으로 댐이나 사면과 같은 인공구조물의 내부는 시간과 위치에 따라 상이한 온도 분포를 갖는 것으로 여겨진다. 이와 같은 분포는 구조물의 안전성을 판단하는 데 매우 중요한 기본 자료로 이용될 수 있으며, 특히 댐 구조물의 경우 과도 침투수나 누수에 의한 위험 대역을 파악할 수 있는 기술로 이용될 수 있다. 그러나 기존의 온도 측정 방식은 대형 구조물의 온도를 연속적으로 동시에 측정할 수 없는 단점을 가지고 있다. 본 연구에서는 이를 극복한 새로운 온도 모니터링 장비를 이용하여 댐의 상부 및 하부에 걸쳐, 여러 지점에서 동시에 온도 분포를 측정하였으며, 실내 시험을 통해 누수 대역이 온도 분포의 이상을 충분히 반영하고 있음을 관측하였다. 또한 대상 댐의 전 구역에 걸쳐 전기비저항 조사를 수행한 결과와 온도 모니터링 자료를 비교 분석하여 누수구역의 판별력을 높일 수 있는 방법을 제시하고자 하였다.