• Title/Summary/Keyword: thermal life data

Search Result 185, Processing Time 0.03 seconds

Estimation of THI Index to Evaluate Thermal Stress of Animal-occupied Zone in a Broiler House Using BES Method (BES 기법을 이용한 육계사 내부 고온 스트레스 평가를 위한 THI 지수 모의)

  • Ha, Taehwan;Kwon, Kyeong-seok;Hong, Se-Woon;Choi, Hee-chul;Lee, Jun-yeob;Lee, Dong-hyun;Woo, Saemee;Yang, Ka-young;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sangyeon;Lee, In-bok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.75-84
    • /
    • 2018
  • Thermal stress of livestock has been issued due to recent climate change trends and this causes reproductive disorders, decreased feed consumption, immunosuppression, and increased mortality of animals. Concept of THI has been widely used to quantitatively evaluate the degree of thermal stress for animals, however use of this concept is restricted for animals living in the enclosed facilities such as mechanically ventilated broiler houses. In this study, time-based internal energy flow and variation trends of temperature and humidity were analyzed based on BES technique. Local weather data, insulation characteristics of building materials, heat and moisture generation rate from broilers according to age, algorithm of ventilation operation were adopted for boundary condition of the model to accurately compute THI values inside the mechanically ventilated broiler house. From the BES computation, excess frequency of THI threshold in Jeju city was highest on the assumption that air conditioning equipments were not installed. When general raising density ($39kg\;m^{-2}$) was adopted, total 2,191 hours were exceeded. Excess hours of THI threshold were strongly related to the cumulative air temperature ($R^2=0.87$).

A Study on Performance Assessment of Dry Floors Applied to Long-life Housing (장수명주택에 적용되는 건식바닥의 성능평가에 관한 연구)

  • Seo, Dong-Goo;Lee, Jong-Ho;Kim, Soo-Am;Shin, Yun-Ho;Hwang, Eun-Kyoung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.5
    • /
    • pp.133-143
    • /
    • 2019
  • Various problems regarding the wet floor method such as its complicated process and waste of thermal storage have been raised, but the usage of dry floor recommended for long-life housing has declined due to lack of confidence on the performance of dry floor. The purpose of this study is to secure the credibility of dry floor. Under this purpose, this study considered precedent studies and established directions to secure the performance of long-life housing infill, and thus, 9 performance items (Impact sound, Smoothness, thermal comfort, sensation hardness while walking, falling safety, impact resistance, local compression load, local strength and strain at heating) were drawn. In addition, the experiment was carried out for 5 performances except for legal performance, some dry floor performances and whole spatial performance. As a result, an appropriate result from all performances except was obtained. The performance of dry floor was verified for each item from these results and it is expected to use such results as basic data on dry floor in the future.

Comparison of Differences on Microclimatic Factors and Human Thermal Sensation between in situ Measurement and Computer Modeling (실측과 컴퓨터 모델링을 통한 미기후 요소 및 인간 열환경지수의 차이 비교 분석)

  • Park, Sookuk;Kong, Hak-Yang;Kang, Hoon
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.1
    • /
    • pp.43-52
    • /
    • 2020
  • For investigating restriction in the use of computer modeling results without adjusting them with measured data, this study analyzed and compared microclimatic aspects and human thermal sensation between in situ measurement and computer modeling using ENVI-met in and around a small urban park of downtown Changwon in May, 2012. In the results, ENVI-met underestimated air temperatures and wind speeds than the measured ones and overestimated relative humidities. In the radiation analysis, ENVI-met overestimated solar radiation from the sky hemisphere and terrestrial radiation from the ground hemisphere and underestimated terrestrial radiation from the sky hemisphere. Also, the differences of mean radiant temperatures with the measured ones reached up to 19.6℃ which could create an 1.2 PMV difference. ENVI-met overestimated up to 2.3 PMV and 4℃ UTCI at 12:00. The difference was shown clearly in PMV than in UTCI. Therefore, when computer modeling is used in urban microclimate and human thermal sensation (comfort) studies the modeling results should be compared with measured data and adjusted adequately to adopt the results to urban and landscape planning and design.

Evaluation of Comfort Performance for Modernized Hanok: Targeting Hanok Residence at the Jamjeong-Haetsal Village in Hwasun, Jeonnam Province (신한옥의 쾌적성능 평가: 전남 화순 잠정햇살마을 한옥단지를 대상으로)

  • Choe, Seung-Ju;Lee, Mihyang;Kim, Jae-Hyang;Han, Seung-Hoon
    • Land and Housing Review
    • /
    • v.12 no.2
    • /
    • pp.99-108
    • /
    • 2021
  • With increasing interest in living in hanoks, there's a growing need for more quantitative data on the thermal comfort performance of modern hanoks. With that in mind, this research project studied a modern hanok located in Jamjeong-Haetsal Village in Hwasun, Jeollanam Province as a case study to evaluate the Predicted Mean Vote (PMV) of modernized hanoks. Based on environmental data collected at the hanok and computer simulation both Life-Cycle PMV (L.C.PMV) and Normal PMV (N.PMV) were calculated for the hanok. Study results showed that during the summer and winter seasons the PMV and heat index at major heat and major cold weather points significantly deviated from the comfort zone. The rate of change in PMV was also greater in the winter than in the summer. The study found that the modern hanok lacks proper thermal insulation for maintaining thermal comfort.

Application of Flexible Sintered Brake Pad for TTX (한국형 틸팅열차용 Flexible 소결 브레이크 패드 적용 연구)

  • Ku, Seong-Mo;Lee, Dong-Kyun;Ko, Tae-Hwan;Na, Jong-Tae;Kim, Sang-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.597-603
    • /
    • 2010
  • Metallic sintered brake pads are often applied to Mid/High Speed Train due to its high strength and thermal characteristics. Because of its imbalance contact between discs and pads can greatly influence the life span, one sided wear, discs attack/crack and threat the safety of the train during operation. In this research, we analyzed pressure/temperature distribution between brake pads and disks. Analyzed data had been verified and modified to conduct further tests of Flexible brake pads with small/full-scale dynamo test. Flexible brake pads were installed to TTX train to conduct further tests to identify the differences between Rigid brake pads and Flexible brake pads. In result, Flexible brake pads showed outstanding disk thermal stability, one sided wear, noise and life of pad than rigid brake pad.

  • PDF

An Accelerated Life Test of Booster Pump for Water Purifier (정수기용 부스터펌프의 가속수명시험)

  • Moon, Ji-Seob;Jeong, Seon-Yong;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.281-291
    • /
    • 2011
  • This paper presents an accelerated life test of booster pump for home water purifier. The failure analysis shows that decreased flux due to the plastic deformation of bypass spring adjusting pressure is the predominant failure mechanism. An accelerated life test is designed and implemented to estimate the lifetime of the booster pump. Temperature, water pressure and voltage are selected as accelerating variables through the technical review about failure mechanism. It is assumed that the lifetimes of booster pumps follow lognormal distribution and the combination model of temperature and non-thermal stresses holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.

A Study on the Remain Life with Aging in 22kV CV Cable (특고압 케이블(6.6/22kV) 케이블의 활선열화 수명 판정 방법에 관한 연구)

  • Lee, Kwan-Woo;Mok, Young-Soo;Kim, Bo-Kyeong;Lee, Jong-Bok;Park, Dae-Hee;Park, Bok-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1759-1761
    • /
    • 2004
  • In this paper, we studied on life-decision of underground cable of live-line state. Data of CV 6.6kV and 22kV cable's life is got data measured insulation resistance by D.C. overlapped current. We confirmed that D.C resistance reduced by time. Aging of cable could be occurred by electrical, thermal, mechanical stress and complex aging confirmed that proceeded by Weibull plot. In the result, life of 6.6kV cable remained 21 years till light caution and 35 years till heavy caution, so aging of 6.6kV XLPE cable was not occurred. Life of 22kV cable remained 10 years till light caution and 22 years till heavy caution. We confirmed that the designed life of 22kV cable is similar to the measured life.

  • PDF

Evaluation of input-output energy use in strawberry production in single-span double-layered greenhouses with different thermal-curtain positions

  • Timothy Denen Akpenpuun;Wook-Ho Na;Qazeem Opeyemi Ogunlowo;Anis Rabiu;Misbaudeen Aderemi Adesanya;Prabhat Dutta;Ezatullah Zakir;Hyeon-Tae Kim;Hyun-Woo Lee
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.3
    • /
    • pp.395-406
    • /
    • 2023
  • The large amount of energy required for successful crop production is the main challenge in greenhouse cropping systems. As a response to this challenge a comprehensive evaluation of greenhouse energy consumption was carried out in two structurally similar single-span greenhouses with different thermal curtain positions, with particular attention to energy productivity, specific energy, net energy, and energy ratio. The greenhouses are used for strawberry production. In the R-greenhouse (RGH), the thermal curtain hanged directly at the roof ridge, whereas in the Q-greenhouse (QGH), the thermal curtain was placed 5° from an imaginary vertical axis, from the middle of the roof ridge downwards to the north side of the greenhouse roof. The relevant data were recorded using standard methods. The results indicated that the energy expended in the RGH and QGH systems was 2,186.48 and 2,189.26 MJ/m2, respectively. Electricity and nitrogen fertilizer contributed the highest energy input in both greenhouses and in all seasons. The output energy was 3.12 and 3.82 MJ/m2, respectively, in RGH and QGH in season I and 4.40 and 4.87 MJ/m2 in season II. In terms of energy expended, there was no significant difference between the two greenhouses, nor between the two seasons. These results indicate that greenhouses of the size used in this investigation are not viable in terms of energy productivity, energy-use efficiency, and subsequent economic performance. However, further studies should be conducted to scale-up the information obtained from this investigation.

The Electric Characteristics of the Thermal Aged Insulation-Paper with Moisture Content on the Transformer (변압기 절연지의 수분함량 및 열화에 따른 전기적 특성 연구)

  • Kim, Pil-Hwan;Kim, Ju-Han;Lee, Byung-Sung;Lee, Won-Yeong;Kim, Do-Young;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1909-1911
    • /
    • 2004
  • It is caused that insulation paper, which had got a lot of thermal stress by over-load after installation, should have been deteriorated in electrical and mechanical characteristics. Beside, insulation material is decreased the insulating property and accelerated aging of them in case of dielectric loss when transformers are manufactured with some moisture or transformers would have been them because of moisture-permeation, Therefore, in this study we experienced the influence of moisture content in case of the thermal aged insulation paper. we have measured tan ${\delta}$ and breakdown voltage in the ratio of paper' moisture content before the aging and then taken the same tests again after insulation paper thermally accelerating-aged. There is a purpose to gain data for a life-design and to establish aging mechanism in order to continuously study life expectancy of the insulation paper.

  • PDF

Chemical Properties of Insulation Paper in oil after Thermal Aging (열 열화에 따른 유입절연지의 화학적 특성)

  • Kim, Pil-Hwan;Kim, Jae-Hoon;Kim, Ju-Han;Lee, Won-Yeong;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.77-79
    • /
    • 2004
  • It is caused that insulation paper, which had got a lot of thermal stress by over-load after installation, should have been deteriorated in electrical and mechanical characteristics. Beside, insulation material is decreased the insulating property and accelerated aging of them in case of dielectric loss when transformers are manufactured with some moisture or transformers would have been them because of moisture-permeation. Therefore, in this study we experienced the influence of moisture content in case of the thermal aged insulation paper. we have measured tan 6 and breakdown voltage in the ratio of paper' moisture content before the aging and then taken the same tests again after insulation paper thermally accelerating-aged. There is a purpose to gain data for a life-design and to establish aging mechanism in order to continuously study life expectancy of the insulation paper

  • PDF