• 제목/요약/키워드: thermal insulation rate

검색결과 160건 처리시간 0.029초

단열재 조건에 따른 원자로용기 외벽냉각 성능 예비분석 (A Preliminary Assessment on ERVC Performance Depending on Insulation Conditions)

  • 최동현;장윤석
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.36-43
    • /
    • 2023
  • Lots of researches have been conducted on in-vessel retention (IVR) to prevent or mitigate severe accident in nuclear power plants. Various methodologies were proposed and the external reactor vessel cooling was selected as a part of promising IVR strategy. In this study, the strategy is strengthened by enhancing the natural circulation performance through the adoption of insulation in the reactor cavity. A thermal analysis was carried out based on an assumed accident scenario and its results were used as boundary conditions for subsequent seven flow analysis cases. By comparing the natural circulation performance, effects of annular gaps and insulation shapes on the mass flow rate and flow velocity were quantified. The improvement in cooling performance can be reflected in actual design via detailed assessment.

고압전동기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in High Voltage Motor Stator Windings)

  • 김희동;박의갑;박완조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2392-2395
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in six high voltage motors. Nondestructive tests have been carried out on stand-still motors. These tests include ac current increase rate($\Delta$I), delta tan delta(${\Delta}tan{\delta}$), and maximum partial discharge(PD). AC current and $tan{\delta}$ were measured by Schering bridge. The measurement of PD patterns were conducted using digital partial discharge detector. PD patterns were observed treeing and internal discharges in Motor 1 and 2. The stator windings of two motors were found to be in a poor condition and their were recommended to rewind. The stator. windings of four motors were judged to be in serviceable condition.

  • PDF

Thermal Properties of Interpenetrating Polymer Network Epoxy-silicone Compound

  • Cho, Young-Shin;Shim, Mi-Ja;Klm, Sang-Wook
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.475-478
    • /
    • 1999
  • The thermal properties of epoxy resin/siloxane for the electrical insulation were investigated by using dynamic DSC run method. As the heating rate increased, the peak temperature on dynamic DSC curve increased. From the linear relation on the Kissinger plot the curing reaction activation energy and pre-exponential factor could be obtained. The curing activation energy from the straight line of the Kissinger plot was 46.72 kJ/mol.

  • PDF

하절기 차열성능을 갖는 방수재의 적용에 따른 건축물 표면온도 변화추이 연구 (A Study on the Surface Temperature Change of Building Applied with Thermal Insulation Waterproofing Material During Summer)

  • 김동범;박진상;최수영;박재홍;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.45-46
    • /
    • 2017
  • As the environment and energy problems such as global climate change (global warming, urban heat island phenomenon) and energy depletion have come to the fore, the construction and waterproofing industry are responding more critically to the demands of global green technology and are employing more eco-friendly technologies as of recent. In this study, the application of the waterproofing material with thermal response performance in construction buildings was investigated to confirm whether the thermal performance is being properly secured by the change of the surface temperature. Experimental results showed that the surface temperature difference between before and after the application is at least 19.8℃ at the maximum 26.3℃. When the degradation rate is converted, the degradation effect of about 40% on average was confirmed.

  • PDF

원전용 금속단열재의 내부 형상결정을 위한 설계인자 별 열전달 특성 분석 (Analysis of Heat Transfer Characteristics Based on Design Factors for Determining the Internal Geometry of Metal Insulation in Nuclear Power Plant)

  • 송기오;유정호;이태호;전현익;하승우;조선영
    • 대한기계학회논문집A
    • /
    • 제39권11호
    • /
    • pp.1175-1181
    • /
    • 2015
  • 일반적으로 산업현장에서 많이 사용되고 있는 단열재는 유리섬유와 같은 열전도도가 낮은 재료를 사용함으로써 단열성능을 확보하고 있다. 이와 달리 원전용 금속단열재의 경우 높은 열전도도를 가진 TP 304 스테인리스 박판을 재료로 한정하고 있어 단열성능을 확보하기 위해서는 구조적 측면에서의 접근이 필요하다. 본 연구에서는 금속단열재 내부구조에 대한 설계인자를 전도, 대류, 복사로 구성된 3가지 열전달 모드를 고려해 추출하고 각 인자들이 열전달에 미치는 영향과 각각의 열전달이 전체 열전달에 차지하는 비율을 열 유동해석을 이용하여 파악하고자 하였다. 본 연구를 통해 단열재 내부에서 발생되는 대류현상을 최소화하기 위해 다수의 박판을 삽입함과 동시에 증가하는 전도 비율을 비교하여 내부형상결정을 위한 세 가지 열전달 모드 하에서의 단열성능을 분석하였다.

Tan Delta 측정을 이용한 유침 절연지의 열화특성 분석 (Analysis of Degradation Characteristics for Oil-Paper Insulation using Tan Delta Measurement)

  • 김정태;김우빈
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1518-1523
    • /
    • 2016
  • In this study, in order to understand the degradation characteristics of oil-paper insulation for power transformers and OF cables, tan delta was measured using cable model specimens with long-term accelerated thermal and electrical aging. In addition, to find out the degradation level due to the accelerated aging, tensile strengths of aged papers were measured. As a result, tan ${\delta}$ showed the characteristics of slight decrease at the first stage and then increase with the aging time, which could be analyzed due to the evaporation of remaining moisture and the change of aging rate with time. Also, the trend of tensile strengths with aging temperature and time was appeared to be exponentially decreased and by use of these data equivalent calculated lifetimes and accelerated aging factors were derived for each aging temperatures. After then, tan ${\delta}$ was analyzed with the equivalent operating years. For all different aging temperatures, the aged data were very well fit to the equivalent operating years and it is shown that tan ${\delta}$ was increased with the decrease of tensile strength.

LNG 벙커링용 고효율 LNG 저장탱크 열해석 (Thermal analysis of LNG storage tank for LNG bunkering system)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.876-880
    • /
    • 2015
  • IMO의 규제인 신조 선박에 대한 NOx 80% 감축의 2016년 발효를 앞두고, 청정에너지인 LNG연료 선박 및 벙커링 선박의 보급이 유럽 선진국들을 중심으로 추진되고 있다. LNG 저장탱크는 LNG 벙커링의 필수 설비로 현재의 액체질소 등을 저장하는 극저온 액체 저장탱크와 동일한 구조이며, IMO의 "C"형 가압탱크인 내외 용기로 구성된 2중 탱크에 진공펄라이트 단열재가 충전되는 형식이다. 그러나 이 단열방식은 진공작업이 어렵고 일 LNG 기화량이 2.0 % 내외가 되어 보다 고효율의 탱크가 요구되어 진다. 본 연구에서는 진공과 단열재를 분리하여 내외탱크에 고진공을 적용하고 외부 탱크에 우레탄폼을 가설시킨 탱크 단열 방식을 새로이 고안하여 열해석을 수행하였다. 해석결과 본 개발 탱크는 진공도가 $10^{-3}Torr$ 이하일 때 일 기화량이 0.03 % 이하로 매우 적게 유지될 수 있고, $10^{-4}Torr$ 이하가 되면 일 기화량이 0.11 %가 되었다. 진공이 파괴되는 경우에도 현재 진공펄라이트 단열은 일 4.9 %의 증발이 발생하나, 새 고안 탱크는 일 증발율이 4.12 %가 되는 매우 효율이 높고 안전한 LNG 탱크 단열방식이 되었다.

알루미늄 용탕 보온용기의 단열재 적층구조 변경을 통한 보온성 향상 (Thermal Insulation Improvement by Laminated Adiabatic Structure Change in Holding Furnace with Molten Aluminum Alloy)

  • 황준선;강충길
    • 한국주조공학회지
    • /
    • 제31권6호
    • /
    • pp.336-341
    • /
    • 2011
  • Recently, aluminium usage in the automobile industry has been increased cause of its lightweight. The aluminium has a melting-solidification process in producing line and another melting process was needed in manufacturing process. Two times of melting process for making ingot and casting not only makes the loss of time and money but contaminates the air with Sox, Nox. For this reason, the holding furnace with laminated adiabatic material was developed. This holding furnace can deliver the molten aluminium directly to the industry needing molten aluminium. Recent holding furnace has above $15^{\circ}C/h$ of cooling rate and that causes solidification of molten aluminium. The ANSYS software was used to analysis the heat transfer. The adiabatic materials were laminated with optimized arrangement and holding furnace shape was changed with optimized modelling by ANSYS analysis for reducing the cooling rate of molten aluminium in holding furnace.

상변화물질 함침 경량골재를 사용한 콘크리트의 특성 (The Properties of Concrete with Lightweight Aggregate Impregnated by Phase Change Material)

  • 김세환;전현규;황인동;서치호;김상헌
    • 콘크리트학회논문집
    • /
    • 제25권3호
    • /
    • pp.331-338
    • /
    • 2013
  • 최근 국가적 차원의 녹색성장이라는 패러다임 아래 건설분야에서도 자원과 에너지 절감을 위한 다양한 노력이 시도되고 있다. 이러한 방안의 하나로 단열성능이 향상된 콘크리트의 개발을 목적으로 높은 열저장 용량의 장점이 있는 PCM(phase change material)을 다공성의 경량골재에 함침 및 코팅 처리하여 경량골재 콘크리트를 개발하였으며 이를 평가하였다. 그 결과 흡수율이 높은 경량골재는 PCM 함침 및 코팅에 의해 흡수율이 저하되어 높은 흡수율에 따른 경량골재 콘크리트의 품질 저하를 방지하는 효과가 있음을 확인하였다. 또한 함침하지 않은 경량골재를 사용한 경량골재 콘크리트의 열전도율은 보통골재 콘크리트보다 약 33%의 단열성능 향상을 보였으며 함침된 골재의 경우 보통골재 콘크리트에 비해 40~43%의 단열성능 향상이 있는 것을 확인하였다. 또한 함침된 골재의 경우 비함침 골재에 비해 열전도율이 12~14% 정도 낮아지는 것을 확인 할 수 있었다.

열분석장치를 적용한 PTFE 전기절연재의 수명 예측 연구 (Lifetime Prediction of PTFE Electrical Insulation Material Using Thermal Analysis Technique)

  • 윤성호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제36회 춘계학술대회논문집
    • /
    • pp.296-297
    • /
    • 2011
  • 본 연구에서는 PTFE 전기절연재의 수명예측을 위해 일련의 열중량 분석시험을 수행하였다. PTFE 시료는 온도상승률을 달리하며 상온에서 $700^{\circ}C$까지 온도를 가하였다. PTFE의 활성화에너지는 일정한 중량감소가 발생할 때의 로그 형태 온도상승률에 대한 변환온도 역수 선도에서 계산하였다. 또한 Toop에 의해 제안된 활성화 에너지와 추정 수명과의 관계식을 이용하면 주어진 운용온도 하에서의 PTFE 수명시간도 예측할 수 있다.

  • PDF