• 제목/요약/키워드: thermal insulation of clothing

검색결과 98건 처리시간 0.019초

Phoenics를 이용한 옷감의 종류 및 두께의 변화에 따른 열전달 특성의 수치 해석적 연구 (A Numerical Study on Natural Convection Between Skin and Fabrics)

  • 홍지명
    • 한국의류학회지
    • /
    • 제19권1호
    • /
    • pp.142-148
    • /
    • 1995
  • In this study, FVM (Finite Volume Method) which is one of the 2-dimensional numerical approach has been conducted to anticipate the temperature distribution between skin and clothes by the change of air temperature and fabric characteristics including fabric thickness. Several experimental works have been done to understand the thermal insulation effect (If fabrics on a human body by measuring the averaged temperature in the air layer between skin and clothes or by measuring the thermal resistance of fabrics. However, the formal method is inconvenient to measure the temperature distribution in the air layer to evaluate the insulation rate of the clothes on the skin because the real size of the clearance between skin and the clothes is too small to place the temperature sensor, and in the Tatter method the relationship between human body and the fabrics are ignored. However, the numerical method will be very effective and economical way to evaluate the insulation efficiency of clothes when the computational result is in the reliable range. As the result of this study, the temperature change in the sir layer between skin and clothes was linear to the fabric thickness and this result coincides with many previous experimental results. Moreover, it is possible to predict the optimum fabric thickness for the best thermal insulation in the air layer between skin and clothes.

  • PDF

우편배달원 방안복 개선을 위한 연구 (A Study on the Improvement of Cold Protective Clothing for Mailman)

  • 권명숙;석혜정
    • 복식
    • /
    • 제57권8호
    • /
    • pp.14-23
    • /
    • 2007
  • The purpose of this study was to investigate the present condition of cold protective clothing for mailman, to improve its design in movement, fitness, and other functions, and supply basic data for its performance evaluation. The results are as follows : The 46.60% of those questioned did not satisfy current clod protective clothing fer mailman. Especially, they considered dissatisfactory in properties such as waterproof, comfort, activity, and sweat absorption. The newly developed cold protective clothing is two-piece style composed of jacket and pants. Both jacket and pants are composed of inner and outer clothing individually. In both jacket and pants, their outer clothing's material was waterproof, windproof, and breathable shell fabric on which PTFE film laminated and their inner clothing's material was 100% polyester Polar polis to have better insulation property. The jacket has attachable cap which can be used as rain gear and set-in sleeve with stand collar. It also had big outside patch pockets and side seam pockets to ensure enough storage space. The pants have knee pads to give free movement to knees and slant side pockets. Inner clothing of both jacket and pants can be worn during working inside without out clothing. Insulation of the newly developed cold protective clothing was not better than current one except right hand, left hand and left foo. It is considered that is because thickness of material is the most important factor to influence insulation.

한국 남성용 단일의복의 앙상블 조합시의 온열특성 변화에 관한 연구 - 무풍, 풍속환경하에서 - (A Study on Changes in Thermal Performances in Ensembles Made up of Single Garments Marketed for Korean Men - In Still and Dynamic Air Conditions -)

  • 송민규;권서윤;정현미
    • 한국의류산업학회지
    • /
    • 제14권4호
    • /
    • pp.660-668
    • /
    • 2012
  • The purpose of this study is to analyze the thermal characteristics of garments marketed for Korean males and to investigate the influence of each garment on ensemble, by measuring their insulation values(clo) using thermal manikins. The results are as follows. The total insulations(clo) of ensembles for S/S seasons are between 1.46 and 2.6 clo, with the mean of 2.12 clo. The insulation in the still air condition is 1.23 clo, which means a decrease of 42% compared to the total insulation of all the component garments. The insulation of ensembles for S/S seasons in the dynamic air condition decreased by 46.8%, compared to the still air condition. The total insulation(clo) of ensembles for F/W seasons is between 3.84 and 7.36 clo with the mean of 4.74 clo. The insulation in the still air condition is 2.26 clo, which means a decrease of 53.6% compared to the total insulation of all the component garments. The insulation of ensembles for F/W seasons in the dynamic air condition decreased by 36.2%, compared to the still air condition. As the clo value of each component garment gets higher, the insulation of ensembles gets higher. Especially, the insulation of ensembles was more influenced by outer wear than inner wear. The insulation of ensembles could be predicted by the insulation of outerwear better.

피복재료의 물리적특성과 주관적착용감과의 관계연구 (A Study on Relationship of Fabric Physical Properties and Subjective Properties for Clothing Comfort)

  • 최철호;박우미
    • 한국의류학회지
    • /
    • 제10권2호
    • /
    • pp.29-35
    • /
    • 1986
  • The main purpose of the study was to investigate relationships between subjective evaluation of comfort/discomfort and tactile sensation. It was also attempted to analyse physical properties of fabric, hence to find physical factors which have effects on wearing- comfort. The results were as follows; 1. Polyester fabric B Type ranked the highest on subjective comfort scale of T-shirts. 2. Scratchiness and flexural rigidity among subjective factors were important on overall comfort sensations of the subjects. 3, In winter, subjective factors, suchas Soratchiness, Heaviness & Flexural Rigidity, were significantly correlated with objective factors of Scratchiness, Thickness & Weight, Stiffness, respectively. 4. In summer, subjective factors such as warmth, Heaviness, Clammy & Cling Tension, Flexural Rigidity, were significantly correlated with objective factors of Thermal Insulation, Thickness & Weight, Cling Tension and stiffness, respertively. 5. Scratchiness, Weight, Stiffness & Thermal Insulation among objective factors were important on overall comfort sensation of the subjects.

  • PDF

견·인견과 셀룰로오스섬유 교직물의 쾌적성능 평가 (Comfort Properties of Silk#x00B7;Rayon-Cellulose Fiber Union Fabrics)

  • 배영희;윤창상;정운선
    • 한국지역사회생활과학회지
    • /
    • 제27권4호
    • /
    • pp.795-801
    • /
    • 2016
  • This study was conducted to suggest the best union fabric to combine with cellulose fiber for summer and in-between seasons. Four types of union fabric, viz. silk/flax, silk/cotton, rayon/flax and rayon/cotton, were used as sample fabrics after weaving them in a local textile factory. The air permeability, moisture regain, water absorption, water vapor permeability and thermal insulation of the samples were tested. The results are as follows. The rayon/flax union fabric is the most suitable for summer clothes due to its having the best comfort property of air and water vapor permeability, and moisture and water absorption. For in-between seasons, it is recommended to use the silk/cotton union fabric because of its good thermal insulation properties.

노멕스 허니콤 구조 직물을 적용한 소방관용 특수방화복 개발 및 이의 보호 쾌적 성능평가 (Development of Firefighters' Personal Protective Clothing with Nomex Honeycomb Fabric and its Protective and Comfort Evaluation)

  • 정재연;구본준;김도형;권민재;강성욱;최정윤;이주영
    • 한국의류산업학회지
    • /
    • 제21권5호
    • /
    • pp.606-617
    • /
    • 2019
  • The present study newly developed a firefighters' protective jacket and pants using a Nomex honeycomb structured layer (HPC) in cases of being exposed to flashover or flameover. This study evaluated the protective and comfort functions of an HPC compared to the current KFI firefighters' protective clothing (FPC). The results are as follows. First, thermal protective performance (TPP) of fabric layers was 2.75 times greater for HPC than FPC at $125kW/m^2$. Second, the predicted second and third degree burn areas were smaller for HPC than FPC when using a flame manikin. Third, thermal insulation using a thermal manikin was 0.2 clo greater for HPC than FPC. Fourth, there were no marked differences in maximal performance, mobility, and microclimate temperature/humidity between FPC and HPC through human wear trials. The thermal insulation of HPC was higher than that of FPC; however, any negative effect of HPC thermal insulation on the comfort functions for firefighters was not found. In conclusion, the newly-developed HPC provided more protection in reducing burn injuries from $125kW/m^2$, while no negative impact on maximal performance, mobility and thermal comfort functions of firefighters, which is appropriate for quick-evasive tactics at the flashover, flameover or back draft fires.

착탈식 라인어와 아웃도어 의복의 보온성 (Detachable Liner and Insulation of Outdoor Clothing)

  • Kim, Chil-Soon
    • 한국의류학회지
    • /
    • 제26권12호
    • /
    • pp.1756-1764
    • /
    • 2002
  • 본 연구의 목적은 의복시스템 내 에서 착탈이 가능한 라이너 가 있을 때 얼마만큼의 보온성 이 증가되는가를 알고자 하는 것이다. 서로 다른 섬유조성 과 두께를 가지는 3개 의 의복앙상블을 선정하여 움직일 수 있는 마네킨을 사용하여 14$^{\circ}C$로 조절되어 있는 인공기후실에서 보온성을 측정하였다. 그 결과 라이너 사용 후 보온성이 증가되었는데 그 정도는 라이너 의 두께 와 섬유조성에 따라서 다르며 약 0.5 clo 증가하였다. 이 결과로부터 착탈 가능한 라이너의 사용으로 추운기후에 어느 정도 적응 할 수 있는가를 확인할 수 있었다.

한국 남자 군인 기능성 방한복 내피 개발을 위한 실태 및 만족도 조사 (A Survey on Actual Wearing Condition and Satisfaction of Functional Inner Winter Uniform for Male Soldiers in Korea)

  • 김연주;김선영
    • 한국의류학회지
    • /
    • 제46권5호
    • /
    • pp.910-926
    • /
    • 2022
  • Suitability for the human body, freedom to move and thermal insulation are important design considerations in military clothing. This study investigates the performance and wearer-satisfaction of the functional inner winter uniform currently used in Korea; it is hoped that our data can inform the development of a future version. Interviews were conducted, in which the participants suggested various improvements. The uniforms were mainly worn for guard duty or as daily attire in cold weather. The participants chose how many layers to wear according to the current situation, rather than sticking to the layering recommended in the manual. Layering choices did not significantly affect combat efficiency but were found to affect wearers' comfort. Wearers' satisfaction was found to depend on the convenience of the clothing, whether it was in the appropriate size, freedom to move and thermal insulation. Also, this study suggests a problem with the current size system, as the analysis of size distribution, across all sizes, the range of current production is insufficient to cover the demand.

세라믹스 처리된 나일론 직물의 원적외선 방사성능과 보온효과 (Far IR Emission and Thermal Properties of Ceramics Coated Nylon Fabrics)

  • 여숙영;이동화;김은애
    • 한국의류학회지
    • /
    • 제22권4호
    • /
    • pp.515-524
    • /
    • 1998
  • The purpose of this study was to evaluate the thermal properties of ceramics coated nylon fabrics by determining far infra-red emissive properties, heat storage/release and thermal insulation. Far IR emissivity and emissive power were measured for 7~ 140n at 50'C . Three types of ceramics such as cordierite with $\alpha$-alumina, a-alumina with titanium oxide and a-alumina were chosen as specimens. Cordierite with $\alpha$-alumina was chosen to treat on the fabrics due to the good emissive properties on the fabrics. Add-ons and contents of ceramics were analyzed for ceramics and/or polyurethane coated fabrics. For the physical properties, thickness and air permeability were measured. Results showed a difference in the emissive property between ceramics themselves and ceramics coated fabrics. In the ambient temperature, there was no diffenence in emissivity among the different ceramics contents. Thermography showed that when the fabric was heated with the light, surface mean temperatures of fabrics were increased as the contents of ceramics increased, and the heat storage property was confirmed. In case of same thickness and air permeability, the thermal insulation value increased as the contents of ceramics increased because of increasing heat storage and Far IR reflectivity. So there were absorption and heat storage of ceramics for Far IR from human and reflection to human between ceramics coated fabrics and human.

  • PDF

청바지의 소재별 쾌적감에 관한 연구 (Comport Sensation of Blue Jeans depending on Fiber Contents)

  • 홍문경;이미식;권계화;전정애
    • 한국의류학회지
    • /
    • 제25권2호
    • /
    • pp.237-248
    • /
    • 2001
  • The purpose of this study was to compare the comfort sensation depending on four different kinds of denim blue jeans: cotton, cotton/tencel, tencel, cotton/pp. The objective and subjective experiments were conducted to measure the comfort of blue jeans. To investigate the objective comfort, physical properties related to thermal insulation, moisture properties and hand were measured. For subjective comfort measurement, 5 healthy female college students were taken as subjects. The outcomes of the experiments are as follows: The higher the air permeability and bulk density of the denim, the lower the thermal insulation, the thicker the denim, the higher the thermal insulation. Tencel blending denim showed the higher bulk density, the lower air contents, and consequently the lower thermal insulation than the other denims. Tencel showed the highest moisture regain, and cotton/tencel blend showed the highest water vapor permeability. Tencel denim had relatively better flexibility, shape stability and elastic recovery than the other denims. The total hand values of the denims by KES-FB system were not significantly different. Cotton and cotton/pp denims raised the subjects body temperature after excercise more than tencel or cotton/tencel denims. Average skin temperature was found to have a correlation with micro climate temperature and micro climate humidity. The correlation coefficients were 0.749 and 0.767, respectively. However, average skin temperatures were not significantly different among the materials. Pulse rate was found to be the highest when wearing cotton/pp and the lowest in case of cotton/tencel denim. The energy was consumed in order of cotton>cotton/pp>tencel>cotton/tencel. There was no significant difference in preference before excercise, but, after the excercise, the order of preference changed as the following; cotton/tencel>tencel>cotton/pp>cotton.

  • PDF