• 제목/요약/키워드: thermal imaging

검색결과 615건 처리시간 0.023초

실시간 열영상 대조비 개선을 위한 대역추출 및 플래토 평활화 알고리즘 적용 (Application of Local Histogram and Plateau Equalization Algorithm for Contrast Enhancement of Real Time Thermal Image)

  • 조흥기;김수곤;전희종
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권2호
    • /
    • pp.76-85
    • /
    • 2004
  • In this paper, the contrast enhancement method of thermal image is proposed and it is the plateau equalization algorithm using local histogram for the real time display of infrared imagery. Through hardware implementing, its practicality and adequacy are proved. Examinations are executed to verify the effect of contrast enhancement by bright control and contrast control automatic to the plateau value in the manual mode, and that verified the effect of contrast enhancement in the automatic mode and the practicality in the real system. According to the experiment results, the proposed "the application of local histogram and plateau equalization algorithm for contrast enhancement of real time thermal image"in this dissertation is the verified method for the thermal imaging contrast enhancement.

피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발 (The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient)

  • 정종문;박성훈;이용식;김재현
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

비정질 셀레늄 기반에서 CsI:Na 응용을 위한 Na의 조성비 연구 (The study of Na Doping rate for application CsI:Na in the amorphous selenium)

  • 차병열;박지군;강상식;이규홍;남상희;최흥국
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.412-414
    • /
    • 2003
  • This paper is about research of scintillator layer, which is used for Hybrid method to increase electric signals in a-Se, the material of Direct method. In case of the thermal evaporation, CsI has column structure which is an disadvantage as scintillator. But it decreases scattering of incident X-ray, has better Light output intensity than other scintillation materials. CsI was made by Thermal evaporation. The Doping material, Na, 0.1, 0.3, 0.5, 0.7g were added in each sample. Analysis of absorbed wavelength, PL(Photoluminescence), Light output intensity, SEM, and XRD analysis were performed to analyze optical characteristics. Doping rate of CsI:Na to use as scintillation layer in a-Se based detector could be optimized.

  • PDF

적외선 열화상을 이용한 비파괴시험 활용 및 결함 진단 (The Utilization of Nondestructive Testing and Defects Diagnosis using Infrared Thermography)

  • 최만용;김원태
    • 비파괴검사학회지
    • /
    • 제24권5호
    • /
    • pp.525-531
    • /
    • 2004
  • 본 고는 적외선 열화상의 개념과 적외선열화상 측정윈리 및 카메라 셋팅을 기술하고 적외선열화강(IRT)에 의한 비파괴검사(NDT)의 활용 및 비파괴검사의 진단에 대하여 살펴보았다. 적외선 열화상은 주어진 표면을 따라 온도에 관련된 열패턴의 평가를 통한 정기적인 비접촉, 비파괴 시험의 수행으로 초기에 장비 고장의 예방이 가능하다. 진단 활용으로서, 열적으로 가열된 내부결함이 있는 블록에 대하여 적외선열화상을 이용한 열화상 패턴을 비파괴 기법으로 평가하고, 결함과 열화상패턴간의 특성을 분석하여 열화상 평가 기법에 대하여 논하였다.

적외선 열화상을 활용한 리튬 이온 ESS의 방열설계 성능평가에 관한 연구 (A Performance Evaluation of a Heat Dissipation Design for a Lithium-Ion Energy Storage System Using Infrared Thermal Imaging)

  • 김은지;이경일;김재열
    • 한국기계가공학회지
    • /
    • 제19권5호
    • /
    • pp.105-110
    • /
    • 2020
  • The global battery market is rapidly growing due to the development of vehicles(EV) and wireless electronic products. In particular logistics robots, which hielp to produce EVs, have attracted much interest in research in Korea Because logistics sites and factories operate continuously for 24 hours, the technology that can dramatically increase the operation time of the logistics equipment is rapidly developing, and various high-level technologies are required for the batteries used in. for example, logistics robots. These required technologies include those that enable rapid battery charging as well wireless charging to charge batteries while moving. The development of these technologies, however, result in increasing explosions and topical accidents involving rapid charging batteries These accidents due to the thermal shock caused by the heat generated during the charging of the battery cell. In this study, a performance evaluation of a heat dissipation design using infrared thermal imaging was performed on an energy storage systrm(Ess) applied with an internal heat conduction cooling method using a heating plate.

화재용 열화상 카메라의 영상포화특성 평가 (Performance Evaluation of Image Saturation of Thermal Imaging Camera for the Fire Service)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.69-74
    • /
    • 2012
  • 적외선 파장영역의 높은 연기투과율에 기초한 열화상기술은 화재안전분야에서 효과적인 첨단기술 중의 하나로 인식되고 있다. 본 연구는 주변열적조건에 따른 열영상 포화특성을 파악하고 대조비변환함수(CTF)를 이용하여 영상의 수준을 평가하고자 한다. 본 실험에서 수행된 조건에 대해 BST 센서를 적용한 열화상 카메라의 경우 영상포화가 발생하지 않았으며 영상수준이 배경과 목표물의 온도차에 비례하는 것으로 나타났다. 본 연구는 열화상기술의 신뢰성을 확보하고 기술개발을 위한 기초자료로 활용될 수 있다.

초정밀 열 영상 현미경 광학계 개발 (Development of the Ultra Precision Thermal Imaging Optical System)

  • 양순철;원종호
    • 한국정밀공학회지
    • /
    • 제27권12호
    • /
    • pp.15-21
    • /
    • 2010
  • Recently, there is a demand for a thermal imaging microscope in the medical field as well as the semi-conductor industry Although the demand of the advanced thermal imaging microscope has been increased, it is very difficult to obtain the technology of developing a thermal camera, because it is used for defense industry. We developed the ${\times}5$ zoom microscope which has $3\;{\mu}m$ spatial resolution to research the design and fabrication of the IR (Infrared) optical system. The optical system of the IR microscope consists of four spherical lenses and four aspheric lenses. We verified individual sensitivity of each optical parameter as the first order approach to the analysis. And we also performed structure and vibration analysis. The optical elements are fabricated using Freeform 700A. The measurement results of surface roughness and form accuracy using NT 2000 and UA3P are Ra 2.36 nm and P-V $0.13\;{\mu}m$. Finally we ascertained resolution power of $3\;{\mu}m$ using USAF (United State Air Force) 1951 IR resolution test chart.

Digital Infrared Thermal Imaging of Crape Myrtle Leaves Infested with Sooty Mold

  • Kim, Jiyeon;Kweon, Si-Gyun;Park, Junhyung;Lee, Harim;Kim, Ki Woo
    • The Plant Pathology Journal
    • /
    • 제32권6호
    • /
    • pp.563-569
    • /
    • 2016
  • The spatial patterns for temperature distribution on crape myrtle leaves infested with sooty mold were investigated using a digital infrared thermal imaging camera. The mean temperatures of the control and sooty regions were $26.98^{\circ}C$ and $28.44^{\circ}C$, respectively. In the thermal images, the sooty regions appeared as distinct spots, indicating that the temperatures in these areas were higher than those in the control regions on the same leaves. This suggests that the sooty regions became warmer than their control regions on the adaxial leaf surface. Neither epidermal penetration nor cell wall dissolution by the fungus was observed on the adaxial leaf surface. It is likely that the high temperature of black leaves have an increased cooling load. To our knowledge, this is the first report on elevated temperatures in sooty regions, and the results show spatial heterogeneity in temperature distribution across the leaf surface.

적외선 패널히터의 온도분포 측정 (Measurement of Temperature Distribution in the Infrared Panel Heater)

  • 이공훈;하수석;김욱중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1178-1183
    • /
    • 2004
  • Temperature distribution and heating characteristic of the panel heater for infrared heating have been investigated. The temperature variation with time is firstly measured with the thermocouple to figure out the response time of the heater to the power input. The heater reaches faster to the steady state in comparison to the ceramic heater. The infrared thermal imaging system is utilized to investigate the temperature distribution over the heater surface. The measured thermal images show that the thermal boundary layer induced by the free convection near the heater surface affects the temperature distribution on the surface. The images also show the fairly good uniformity of the temperature distribution in the core region of the surface.

  • PDF