지중 열반응 현장시험에서 소비전력 변동의 영향 (Influences of Power Fluctuation on In-Situ Ground Thermal Response Testing)

  • 김진상;박근우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.707-712
    • /
    • 2006
  • Knowing the ground thermal conductivity is very importnat in designing ground heat exchangers. Knowledge of the ground soil and rock composition information dose not guarantee the prediction of accurate thermal information. In Situ testing of ground heat exchangers is becoming popular. However, in situ testing are performed at construction sites in real life. Adequate data collection and analysis are not easy mainly due to poor power quality. Power fluctuation also causes the fluctuation of received data. The power quality must be maintained during the entire in situ testing processes. To accurately analyse the test data, the understanding of the response of the power fluctuation is essential. Testing under the power quality varied by tester is very difficult. Analyzing power variation by numerical simulation is a realistic option. By varying power in a sinosuidal manner, its effects on predicting thermal conductivity from thermal response plots made from the test data are examined.

  • PDF

여름철 도시의 일상생활에서 폭로되는 환경온도와 온냉감 평가 (Thermal Diary - 24 hours' Exposed Temperature and Thermal Comfort in Urban Life, Summer)

  • 이민정;전정윤
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2002년도 추계학술발표대회
    • /
    • pp.333-337
    • /
    • 2002
  • All the outdoor and indoor spaces are connected with each other. The human being moves toward those spaces and experiences temperature fluctuation between the natural and artificial temperature. We conducted an experiment which subjects are the college students wearing the data logger in urban life, and measured 24 hours' exposed temperature and thermal comfort in summer. Results were as follows. 1. Most subjects get weather information(84.6%). Fashion(46.2%) and weather (30.8%) are the reasons to select clothes. They spend their time in indoor environment for 84.92% hours of a day and have an air-conditioner(61.5%) in their houses. 2. Exposed temperature fluctuation were from 33.8$^{\circ}C$ to 15.6$^{\circ}C$. The median value of experienced temperature were 26-27$^{\circ}C$ and average temperature was 26.3$^{\circ}C$. Subjects experienced cold shock of 3.96 times in a day and 67.21% of all evaluated thermal comfort in the range of -1 and 1 by ASHRAE 7 Category Scales. Artificial environment which connected with outside let people experienced temperature fluctuation in wide range.

  • PDF

여름철 도시의 일상생활에서 경험하는 환경온도와 온냉감 평가 (24 hours' Exposed Temperature and Thermal Comfort in Summer)

  • 전정윤;이민정
    • 한국주거학회논문집
    • /
    • 제14권3호
    • /
    • pp.51-56
    • /
    • 2003
  • All the outdoor and indoor spaces are connected with each other. The human being moves toward those spaces with temperature fluctuation between the natural and artificial temperature. We conducted an experiment which subjects were wearing the data logger in urban life, and measured 24 hours' exposed temperature and thermal comfort in summer. Results were as follows. 1. Subjects controls their micro climate like this. Most of them(84.6%) get weather information. Fashion(46.2%) and weather(30.8%) are the reasons to select clothes. They spend their time in indoor environment for 84.92% hours of a day and have an air-conditioner(61.5%) in their houses. 2. Temperature fluctuation which subjects were exposed for 24 hours were from 15.6$^{\circ}C$ to 33.8$^{\circ}C$ and average fluctuation was 9.02$^{\circ}C$. The median value of experienced temperature were 26-26.5$^{\circ}C$ and average temperature was 26.18$^{\circ}C$. They experienced cold shock of 3.96 times in a day.

실린더 헤드의 비정상 열전달 및 열응력 해석 (Unsteady heat transfer and thermal stress analysis of a gasoline engine cylinder head)

  • 박진무;임영훈;김병탁
    • 오토저널
    • /
    • 제12권3호
    • /
    • pp.41-52
    • /
    • 1990
  • In this study are determined the unsteady temperature and thermal stress fields for a domestic 4-cylinder, 4-cycle gasoline engine cylinder head by the three-dimensional finite element method. A representative part of the cylinder head is modelled as a combination of hexahedron isoparametric elements, and the time-dependent temperature and the heat transfer coefficient of the gas are imposed as the thermal boundary conditions for the engine speeds of 500 rpm and 2000 rpm. The obtained results, which are represented graphically, indicate that the amplitudes of temperature fluctuation during a cycle are about 10.deg. C and 3.deg. C respectively on the surface of combustion chamber, and the maximum temperature fields occur at 30.deg. , 10.deg. respectively before the initiation of the exhaust stroke. Thermal stress fields due to non-uniform temperature distributions show that compressive stress is much larger than tensile stress throughout a cycle. It is also found that the compressive stress varies with substantial amplitude between the exhaust port and ignition plug hole, and the high tensile stress with small fluctuation occurs between exhaust port and the adjacent head bolt hole.

  • PDF

Numerical analysis of temperature fluctuation characteristics associated with thermal striping phenomena in the PGSFR

  • Jung, Yohan;Choi, Sun Rock;Hong, Jonggan
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3928-3942
    • /
    • 2022
  • Thermal striping is a complex thermal-hydraulic phenomenon caused by fluid temperature fluctuations that can also cause high-cycle thermal fatigue to the structural wall of sodium-cooled fast reactors (SFRs). Numerical simulations using large-eddy simulation (LES) were performed to predict and evaluate the characteristics of the temperature fluctuations related to thermal striping in the upper internal structure (UIS) of the prototype generation-IV sodium-cooled fast reactor (PGSFR). Specific monitoring points were established for the fluid region near the control rod driving mechanism (CRDM) guide tubes, CRDM guide tube walls, and UIS support plates, and the normalized mean and fluctuating temperatures were investigated at these points. It was found that the location of the maximum amplitude of the temperature fluctuations in the UIS was the lowest end of the inner wall of the CRDM guide tube, and the maximum value of the normalized fluctuating temperatures was 17.2%. The frequency of the maximum temperature fluctuation on the CRDM guide tube walls, which is an important factor in thermal striping, was also analyzed using the fast Fourier transform analysis. These results can be used for the structural integrity evaluation of the UIS in SFR.

단백질의 동적특성해석을 위한 전산해석기법 연구 (Computational Methodology for Biodynamics of Proteins)

  • 안정희;장효선;엄길호;나성수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.476-479
    • /
    • 2008
  • Understanding the dynamics of proteins is essential to gain insight into biological functions of proteins. The protein dynamics is delineated by conformational fluctuation (i.e. thermal vibration), and thus, thermal vibration of proteins has to be understood. In this paper, a simple mechanical model was considered for understanding protein's dynamics. Specifically, a mechanical vibration model was developed for understanding the large protein dynamics related to biological functions. The mechanical model for large proteins was constructed based on simple elastic model (i.e. Tirion's elastic model) and model reduction methods (dynamic model condensation). The large protein structure was described by minimal degrees of freedom on the basis of model reduction method that allows one to transform the refined structure into the coarse-grained structure. In this model, it is shown that a simple reduced model is able to reproduce the thermal fluctuation behavior of proteins qualitatively comparable to original molecular model. Moreover, the protein's dynamic behavior such as collective dynamics is well depicted by a simple reduced mechanical model. This sheds light on that the model reduction may provide the information about large protein dynamics, and consequently, the biological functions of large proteins.

  • PDF

혼합배관 내의 열 경계층 이동으로 인한 고주기 온도요동에 관한 연구 (A Study on High Cycle Temperature Fluctuation Caused by Thermal Striping in a Mixing Tee Pipe)

  • 김석범;박종호
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.9-19
    • /
    • 2007
  • Fluid temperature fluctuations in a mixing tee pipe were numerically analyzed by LES model in order to clarify internal turbulent flows and to develope an evaluation method for high-cycle thermal fatigue. Hot and cold water with an temperature difference $40^{\circ}C$ were supplied to the mixing tee. Fluid temperature fluctuations in a mixing tee pipe is analysed by using the computational fluid dynamics code, FLUENT, Temperature fluctuations of the fluid and pipe wall measured as the velocity ratio of the flow in the branch pipe to that in the main pipe was varied from 0.05 to 5.0. The power spectrum method was used to evaluate the heat transfer coefficient. The fluid temperature characteristics were dependent on the velocity ratio, rather than the absolute value of the flow velocity. Large fluid temperature fluctuations were occurred near the mixing tee, and the fluctuation temperature frequency was random. The ratios of the measured heat transfer coefficient to that evaluated by Dittus-Boelter's empirical equation were independent of the velocity ratio, The multiplier ratios were about from 4 to 6.

Unsteady heat exchange at the dry spent nuclear fuel storage

  • Alyokhina, Svitlana;Kostikov, Andrii
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1457-1462
    • /
    • 2017
  • Unsteady thermal processes in storage containers with spent nuclear fuel were modeled. The daily fluctuations of outer ambient temperatures were taken into account. The modeling approach, which is based on the solving of conjugate and inverse heat transfer problems, was verified by comparison of measured and calculated temperatures in outer channels. The time delays in the reaching of maximal temperatures for each spent fuel assembly were calculated. Results of numerical investigations show that daily fluctuation of outer temperatures does not have a large influence on the maximal temperatures of stored spent fuel, so that fluctuation can be neglected and only daily average temperature should be considered for safety estimation using the "best estimation" approach.

진공조에 위치한 1차 SQUID 미분계를 이용한 헬멧형 뇌자도 장치의 제작 (A Helmet-type MEG System with $1^{st}$ order SQUID Gradiometer Located in Vacuum)

  • 유권규;김기웅;이용호
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.78-82
    • /
    • 2009
  • We have fabricated a helmet type magnetoencephalogrphy(MEG) with a $1^{st}$ order gradiometer in vacuum to improve the signal-to-noise ratio(SNR) and the boil-off rate of liquid helium(LHe). The axial type first-order gradiometer was fabricated with a double relaxation oscillation SQUID(DROS) sensor which was directly connected with a pickup coil. The neck space of LHe dewar was made to be smaller than that of a conventional dewar, but the LHe boil-off ratio appeared to increase. To reduce the temperature of low Tc SQUID sensor and pickup coil to 9 K, a metal shield made of, such as copper, brass or aluminum, have been usually used for thermal transmission. But the metal shield exhibited high thermal noise and eddy current fluctuation. We quantified the thermal noise and the eddy current fluctuation of metal. In this experiment, we used the bobbin which was made of an alumina to wind Nb superconductive wire for pickup coil and the average noise of coil-in-vacuum type MEG system was $3.5fT/Hz^{1/2}$. Finally, we measured the auditory evoked signal to prove the reliability of coil-in-vacuum type MEG system.