• 제목/요약/키워드: thermal factors

검색결과 1,480건 처리시간 0.029초

매스콘크리트의 타설높이 및 양생조건에 따른 온도균열 저감 방안에 관한 연구 (Thermal Crack Control of Mass Concrete by Concrete Placing Height and Curing Method)

  • 민병소;신길수;김대권;이현희;신성우;이광수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.369-376
    • /
    • 2001
  • As many studies have performed to reduce thermal cracking in mass concrete, it is already prepared against thermal cracking, we can find many plans against thermal cracking in several reference book. But it needs practical guidelines to be available in construction site. In this study to establish control method of thermal cracking in mass concrete, tests which have factors of placing thickness and curing method of concrete are performed.

  • PDF

한국의 암석 열전도도에 관한 연구 (A study on thermal conductivities of rocks in Korea)

  • 박정민;김형찬;이영민;송무영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.449-451
    • /
    • 2007
  • We made 980 thermal conductivity measurements on igneous, metamorphic, sedimentary, and volcanic rock samples from Korea. The average thermal conductivity of igneous, metamorphic, sedimentary, and volcanic rocks are 3.41 W/m-K, 3.98 W/m-K, 4.10 W/m-K, and 3.21 W/m-K, respectively. Thermal conductivity values of a rock type generally have a wide range because thermal conductivity depends on various factors such as dominant mineral phase, micro-structure, anisotoropy and so on. Thermal properties (thermal conductivity, thermal diffusivity and specific heat) are important variables which are used to design a geothermal heat pump(GHP) system. Therefore, our thermal property data can contribute on a efficient design of a GHP system.

  • PDF

ASSESSMENT OF THERMAL FATIGUE IN MIXING TEE BY FSI ANALYSIS

  • Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • 제45권1호
    • /
    • pp.99-106
    • /
    • 2013
  • Thermal fatigue is a significant long-term degradation mechanism in nuclear power plants. In particular, as operating plants become older and life time extension activities are initiated, operators and regulators need screening criteria to exclude risks of thermal fatigue and methods to determine significant fatigue relevance. In general, the common thermal fatigue issues are well understood and controlled by plant instrumentation at fatigue susceptible locations. However, incidents indicate that certain piping system Tee connections are susceptible to turbulent temperature mixing effects that cannot be adequately monitored by common thermocouple instrumentations. Therefore, in this study thermal fatigue evaluation of piping system Tee-connections is performed using the fluid-structure interaction (FSI) analysis. From the thermal hydraulic analysis, the temperature distributions are determined and their results are applied to the structural model of the piping system to determine the thermal stress. Using the rain-flow method the fatigue analysis is performed to generate fatigue usage factors. The procedure for improved load thermal fatigue assessment using FSI analysis shown in this study will supply valuable information for establishing a methodology on thermal fatigue.

자동차 운전석의 온열환경 쾌적성 평가를 위한 지표개발 (Development of the Index to Estimate Thermal Comfort in the Driving Room of Motorcar)

  • 최성주;박근상
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1998년도 춘계학술대회논문집
    • /
    • pp.188-193
    • /
    • 1998
  • The purpose of the study is to develop a numerical model based on experimental data to estimate the thermal comfort in the driving room of a motorcar. For the ecperiments, three air temperature level of 21, 23, 25 .deg. C are set to measure variable such as average skin temperature, R-R interval, the comfort sensation, and the performance level. By performing statistical analysis with the results obtainted, it is observed that two physiological factors-average skin temperature and R-R interval have significant relation with the thermal comfort in the driving room. Thus, those two factors are included as parameters in the proposed model to estimate the thermal comfort.

  • PDF

회전압축기형 스털링냉동기의 성능에 관한 실험적 연구 (The Experimental Study of the Performance of the Rotary Stirling refrigerator)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1312-1316
    • /
    • 2004
  • The Stirling refrigerators have been widely used for the cooling of the infrared detector and HTS to the cryogenic temperature. The Stirling refrigerator with the rotary compressor are applicable to the cooling device for the compact mobile thermal imaging system, because the refrigerators have the compact structure and light weight. The typical performance factors of the Stirling refrigerator are the cool-down time, cooling capacity at the desired temperature and the input power. And the above performance factors are depends on the thermal insulation characteristics of the Dewar. In this study, the steady thermal load of the Dewar and the performance of the Stirling refrigerator were measured. The results show the dependency of the input power and the charging pressure on the performance of the refrigerator.

  • PDF

비정상 열 하중을 받는 이질재료의 열량 집중 계수 해석 (Thermal flow intensity factor for non-homogeneous material subjected to unsteady thermal load)

  • 김귀섭
    • 한국항공운항학회지
    • /
    • 제16권4호
    • /
    • pp.26-34
    • /
    • 2008
  • This article provides a comprehensive treatment of cracks in non-homogeneous structural materials such as functionally graded materials (FGMs). It is assumed that the material properties depend only on the coordinate perpendicular to the crack surfaces and vary continuously along the crack faces. By using laminated composite plate model to simulate the material non-homogeneity, we present an algorithm for solving the system based on Laplace transform and Fourier transform techniques. Unlike earlier studies that considered certain assumed property distributions and a single crack problem, the current investigation studies multiple crack problem in the FGMs with arbitrarily varying material properties. As a numerical illustration, transient thermal flow intensity factors for a metal-ceramic joint specimen with a functionally graded interlayer subjected to sudden heating on its boundary are presented. The results obtained demonstrate that the present model is an efficient tool in the fracture analysis of non-homogeneous material with properties varying in the thickness direction.

  • PDF

소성변형 및 마멸을 고려한 열간 단조 금형의 수명 평가 (Tool life Evaluation of Hot Forging about Plastic Deformation and Wear)

  • 이현철;김동환;김병민
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.163-168
    • /
    • 2002
  • Hot forging is widely used in the manufacturing of industry machine component. The mechanical, thermal load and thermal softening which are happened by the high temperature in hot forging process. Tool life decreases considerably due to the softening of the surface layer of a tool caused by a high thermal load and long contact time between the tool and billet. Also, tool life is to a large extent limited by wear, heat crack and plastic deformation in hot forging process. These are one of the main factors affecting die accuracy and tool life. That is because hot forging process has many factors influencing tool life, and there was not accurate in-process data. In this research, life prediction of hot forging tool by wear and plastic deformation analysis considering tempering parameter has been carried out for automobile component. The new developed technique in this study for predicting tool life can give more feasible means to improve the tool life in hot forging process.

  • PDF

콘크리트 박스거더 교량 바닥판의 종방향 균열 위험성 정가 (Risk Evaluation of Longitudinal Cracking in Concrete Deck of Box Girder Bridge)

  • 김의성
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.84-90
    • /
    • 2008
  • The occurrence of longitudinal cracking in concrete deck of box girder bridge is affected by many factors, but the most important factors are the shrinkage and thermal gradient of deck slabs. In this study, therefore, the tensile stresses at the bottom of deck were calculated from the experimental data(autogeneous shrinkage, drying shrinkage, and thermal gradient of deck slab). Also, the possibility of longitudinal cracks at bottom of deck was estimated. For this purpose, full-scale box girder segments have been fabricated and tested. The thermal gradients and shrinkage strains of deck slabs were measured after placement of concrete. Also, analytic program was conducted for the evaluation of longitudinal cracking in bridge deck considering differential shrinkage induced from non-uniform moisture distributions in concrete.

대학생 거주 원룸형 다가구주택의 겨울철 실내열공기환경 실태 (The Indoor Thermal and Air Environment during Winter in One-room Type Multi-family Houses Occupied by University Students)

  • 최윤정;김운학
    • 한국생활과학회지
    • /
    • 제19권4호
    • /
    • pp.745-760
    • /
    • 2010
  • The purposes of this study were to investigate the state of indoor thermal and air environment during winter in the one-room type multi-family houses occupied by university students and to analyze factors which influenced this environment. Field survey was conducted in 10 houses between 30th January, 2009 and 13th February, 2009 which measured indoor thermal and air elements as well kept records of interviews with residents and other related factors. Measured elements were air temperature, relative humidity, as well as concentrations of $CO_2$, CO, TVOC, and PM-10. The results can be summarized as follows. 1) The mean air temperature in each house ranged from 19.3 to $25.3^{\circ}C$, so most houses were not suitable for evaluation criteria($20-22^{\circ}C$). The average $CO_2$ concentration in each house was 965~3259ppm, so most houses exceeded evaluation criteria(1000ppm). The average TVOC concentration in each house were 0.00~1.17ppm, 5 houses exceeded evaluation criteria(0.12ppm). 2) Relative humidity, CO concentration, and PM-10 concentration were suitable for evaluation criteria. Therefore, indoor thermal and air environment during winter in one-room type multi-family housing occupied by university students was found to be generally uncomfortable. Important factor which were found to influence air temperature and the concentration of $CO_2$ were smaller space capacity than general house. Other factors which were found to influence the environment of these houses were the existence of a balcony as well as factors relating to the behavior of occupants such whether or not heating were operated, whether windows were opened, whether fans used, whether occupants smoked or used cosmetics, and whether the space was dusted.

커스프균열형 강체함유물의 열응력 세기계수에 관한 연구 (Thermal Stress Intensity Factors for Rigid Inclusions of Cusp Crack Shape)

  • 이강용;최흥섭
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.497-504
    • /
    • 1988
  • 본 연구에서는 트랙션이 없는 커스프 균열에 적용한 방법을 확장하여 무한대 에서 균일열유동을 받는 무한체내에 하이포사이클로이드형(hypocycloid type), 대칭이 기형(symmetric airfoil type), 대칭입술형(symmetric lip type) 강체 함유물이 존재 하고 그 표면은 단열되거나 상대온도가 영으로 주어지는 경우에 대해서 열응력세기계 수(thermal stress intensity factor이하에서 TSIF로 표기함)를 유도하고자 한다.