• Title/Summary/Keyword: thermal factor

Search Result 1,559, Processing Time 0.029 seconds

Effect of Hydride Reorientation on Delayed Hydride Cracking In Zr-2.5Nb Tubes

  • Yun Yeo Bum;Kim Young Suk;Im Kyung Soo;Cheong Yong Moo;Kim Sung Soo
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.529-536
    • /
    • 2003
  • The objective of this study is to investigate the reorientation of hydrides with applied stress intensity factor, the peak temperature and the time when to apply the stress intensity factor in a Zr-2.5Nb pressure tube during its thermal cycle treatment. Cantilever beam (CB) specimens with a notch of 0.5 mm in depth made from the Zr-2.5Nb tube were subjected to electrolytic hydrogen charging to contain 60 ppm H and then to a thermal cycle involving heating to the peak temperature of either 310 or $380^{\circ}C$, holding there for 50 h and then cooling to the test temperature of $250^{\circ}C$. The stress intensity factor of either 6.13 or $18.4\;MPa\sqrt{m}$ was applied at the beginning of the thermal cycle, at the end of the hold at the peak temperatures and after cooling to the test temperature, respectively. The reorientation of hydrides in the Zr-2.5Nb tube was enhanced with the increased peak temperature and applied stress intensity factor. Furthermore, when the CB specimens were subjected to $18.4\;MPa\sqrt{m}$ from the beginning of the thermal cycle, the reoriented hydrides occurred almost all over the Zr-2.5Nb tube, surprisingly suppressing the growth of a DHC crack. In contrast, when the CB specimens were subjected to the stress intensity factor at the test temperature, little reorientation of hydrides was observed except the notch region, leading the Zr-2.5Nb to grow a large DHC crack. Based on the correlation between the reorientation of hydrides and the DHC crack growth, a governing factor for DHC is discussed along with the feasibility of the Kim's DHC model.

Wattmeter for Voltage, Current, Power and Power Factor Measurement (정밀전압, 전류, 전력, 역률측정 전력계)

  • Park, Y.T.;Yu, K.M.;Ryu, K.S.;Kim, H.J.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.625-627
    • /
    • 2002
  • High precision voltages. currents. power factor and electrical power measurements wide range of frequency can be achieved by using the thermo-elements (thermal converters). This paper describes the development wattmeter. based on a thermal principle. The instrument has been performed measurement in the range of currents from 0 to 50 A, voltages up to 600 V, power factor 0.5. 1 and frequencies from 45 Hz to 3 kHz. The thermal converters with two heater are used in the functional element of the wattmeter.

  • PDF

Analysis of a Geometrically Asymmetric Trapezoidal Fin with Variable Fin Base Thickness and Height

  • Kang, Hyung-Suk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.3
    • /
    • pp.83-88
    • /
    • 2008
  • A geometrically asymmetric trapezoidal fin is analyzed using the one-dimensional analytic method. Heat loss and thermal resistance are represented as a function of the fin base thickness, base height, fm shape factor, inside fluid convection characteristic number, convection characteristic numbers ratio, fm length and ambient convection characteristic number. The relationship between the fin base height and the shape factor for equal amounts of heat loss is presented. One of the results shows that the variations of the fm base thickness and the inside fluid convection characteristic number give no effect on the thermal resistance.

Dynamic response of size-dependent porous functionally graded beams under thermal and moving load using a numerical approach

  • Fenjan, Raad M.;Ahmed, Ridha A.;Faleh, Nadhim M.;Hani, Fatima Masood
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.2
    • /
    • pp.69-84
    • /
    • 2020
  • Based on differential quadrature method (DQM) and nonlocal strain gradient theory (NSGT), forced vibrations of a porous functionally graded (FG) scale-dependent beam in thermal environments have been investigated in this study. The nanobeam is assumed to be in contact with a moving point load. NSGT contains nonlocal stress field impacts together with the microstructure-dependent strains gradient impacts. The nano-size beam is constructed by functionally graded materials (FGMs) containing even and un-even pore dispersions within the material texture. The gradual material characteristics based upon pore effects have been characterized using refined power-law functions. Dynamical deflections of the nano-size beam have been calculated using DQM and Laplace transform technique. The prominence of temperature rise, nonlocal factor, strain gradient factor, travelling load speed, pore factor/distribution and elastic substrate on forced vibrational behaviors of nano-size beams have been explored.

Measurement of Stress Intensity Factor of Isotropic Material Using SPATE (SPATE에 의한 등방성체의 응력확대계수 측정)

  • Hwang, Jae-Seok;Seo, Jae-Guk;Lee, Hyo-Jae;Nam, Jeong-Hwan;Rowlangs, R.E.;Choe, Yeong-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.393-404
    • /
    • 1997
  • SPATE(Stress Pattern Analysis by Thermal Emission) can be effectively used to analyze the stress distributions of isotropic structure under the repeated load by non-contact. In this research, the measuring method and the measuring concept of stress intensity factor of isotropic material by SPATE are suggested. The validity of the method and the concept was certified through SPATE experiment.

A Study on Thermal Decomposition of RDX According to the Size using TGA (TGA를 이용한 RDX의 입자 크기에 따른 열적 분해 특성 연구)

  • Bum, Kil-Ho;Kim, Seung-Hee;Kim, Jin-Seuk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.81-85
    • /
    • 2012
  • This work is related to study the thermal decomposition of 1,3,5-trinitro-1,3,5-triazacylohexane(RDX) by differential scanning calorimeter and thermo-gravimetry with Kissinger's & Iso-conversional method under nonisothermal conditions, with heating rate from 2 to $8^{\circ}C$/min or given heating rate. We calculated and compared activation energy with these two methods. Iso-conversional method is better than Kissinger's method to study decomposition mechanism. We also investigated activation energy and frequency factor by Kissinger's & Iso-conversional method with the influence of particle size. In case of single crystal, Cl-3(large crystal) has better thermal stability than Cl-5(small crystal). The activation energy increased according to the size of the particle size.

Fracture Mechanics Analysis of a Reactor Pressure Vessel Considering Pressurized Thermal Shock (가압열충격을 고려한 원자로 압력용기의 파괴역학적 해석)

  • 박재학;박상윤
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.29-38
    • /
    • 2001
  • The purpose of this paper is to evaluate the structural integrity of a reactor pressure vessel subjected to the pressurized thermal shock(PTS) during the transient events, such as main steam line break(MSLB) and small break loss of coolant accident(SBLOCA). For postulated surface or subsurface cracks, variation curves of stress intensity factor are obtained by using the three different methods, including ASME section XI code anlysis, the finite element alternating method and the finite element method. From the stress intensity factor curves, the maximum allowable nil-ductility transition temperatures(RT/NDT/) are determined by the tangent criterion and the maximum criterion for various crack configurations and two initial transient events. As a result of the analysis, it is noted that axial cracks have smaller maximum allowable RT$_{NDT}$ values than same-sized circumferential cracks for both the transient events in the case of the tangent criterion. Axial cracks have smaller RT$_{NDT}$ values than same-sized circumferential cracks for MSLB and circumferential cracks have smaller values than axial cracks for SBLOCA in the case of the maximum criterion.

  • PDF

Development of a TFM load calculation program based on thermal response factor (열응답계수를 이용한 TFM 부하계산법의 제안)

  • 최우영;고철균;이재헌;류해성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.684-691
    • /
    • 1999
  • A load calculation program based on TFM(Transfer function method) has been proposed in this study. The validity of the current method has been verified by comparing heat gain calculation by TRF(Thermal response factor) with that by CTF(Conduction transfer function) adopted in ASHRAE. In addition, it seems that the CTF coefficients given in ASHRAE tables have somewhat ambiguity The load calculation program developed in the current study has been employed to calculate cooling load from the exterior walls and roof of example 6 in the ASHRAE. The results are found in good agreement.

  • PDF

Evaluation Methods on ONDOL Thermal Environmental Index (온돌 온열환경지표 평가방법)

  • Kim, Sung-Jo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.101-110
    • /
    • 2022
  • For this purpose, the authors proposed and proved usefulness of the modified mean skin temperature which is integrated mean radiation temperature and the effect of floor contacted heat conduction. The mean radiation temperature is applied form factor between half cross-legged human body and surrounding wall of indoor. In addition the floor contacted heat conduction is applied heat transfer coefficient of half cross-legged human body. Eight Korean young men were targeted for the experiment. From the experiment the authors excerpted physiological reaction and psychological reaction in Ondol environment which is combined physiccal environmental factor of artificial climate chamber, air and floor temperature. As a result of the experiment it is confirmed that heat conduction has more impact than heat exchange from existing research for the heat exchange between half cross-legged human body and surrounding wall in Ondol thermal environment. Thereby, it is proved the effectiveness of the modified mean skin temperature which is added floor contacted temperature to the Ondol thermal environmental evaluation index.

Human Solar Heat Load and Thermal Comfort in an Outdoor Environment (건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구)

  • Jeong, Chang-Won;Yoon, In
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF