• Title/Summary/Keyword: thermal factor

Search Result 1,559, Processing Time 0.05 seconds

Numerical Simulations of Subcritical Reactor Kinetics in Thermal Hydraulic Transient Phases

  • J. Yoo;Park, W. S.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.149-154
    • /
    • 1998
  • A subcritical reactor driven by a linear proton accelerator has been considered as a nuclear waste incinerator at Korea Atomic Energy Research Institute(KAERI). Since the multiplication factor of a subcritical reactor is less than unity, to compensate exponentially decreasing fission neutrons from spallation reactions are essentially required for operating the reactor in its steady state. furthermore, the profile of accelerator beam currents is very important in controlling a subcritical reactor, because the reactor power varies in accordance of the profile of external neutrons. We have developed a code system to find numerical solutions of reactor kinetics equations, which are the simplest dynamic model for controlling reactors. In a due course of our previous numerical study of point kinetics equations for critical reactors, however, we learned that the same code system can be used in studying dynamic behavior of the subcritical reactor. Our major motivation of this paper is to investigate responses of subcritical reactors for small changes in thermal hydraulic parameters. Building a thermal hydraulic model for the subcritical reactor dynamics, we performed numerical simulations for dynamic responses of the reactor based on point kinetics equations with a source term. Linearizing a set of coupled differential equations for reactor responses, we focus our research interest on dynamic responses of the reactor to variations of the thermal hydraulic parameters in transient phases.

  • PDF

Nonlinear forced vibration of imperfect FG beams with hygro-thermal factor

  • Y.J. He;G.L She
    • Structural Engineering and Mechanics
    • /
    • v.92 no.2
    • /
    • pp.163-172
    • /
    • 2024
  • This paper intends to analyze the nonlinear forced vibrations of functionally graded material (FGM) beams with initial geometrical defects in hygro-thermal ambiences. For this purpose, we assume that the correlation properties of the material alter along the thickness direction in succession and the surface of the beam is subjected to humid and thermal loads. Based on the Euler Bernoulli beam theory and geometrical non-linearity, we use the Hamiltonian principle to formulate a theoretical model with consideration of the hygrothermal effects. Galerkin's technique has been proposed for the control equations of discrete systems. The non-linear primary resonances are acquired by applying the modified Lindstedt-Poincare method (MLP). Verify the reliability of the data obtained through comparison with literature. The non-linear resonance response is reflected by amplitude-frequency response curves. The numerical results indicate that the resonances of FGM beams include three non-linear characteristics, namely hard springs, soft springs and soft-hard spring types. The response modalities of the structure may transform between those non-linear characteristics when material properties, spring coefficients, geometric defect values, temperature-humidity loads and even the external stimulus generate variations.

Optimal Control of Xenon Poison In Nuclear Reactor (원자로에 있어서 Xenon 독소의 최적제어)

  • 곽은호;고병준
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.5
    • /
    • pp.17-23
    • /
    • 1976
  • The buildup of fission product, i.e. Xe-135 poisoning, is a prime factor in restarting a nuclear reactor from the shutdown, which was under normal operation in the high flux thermal reactor, It is caused by the high absorption crosssection of Xe-135 to thermal neutrons and its long half life, from which the thermal power is affected. It is then possible to restart a nuclear reactor after the sufficient excess reactivity to override this poisoning must be inserted, or its concentration is decreased sufficiently when its temporary shutdown is required. As ratter of fact, these have an important influence not only on reactor safety but also on economic aspect in operation. Considering these points in this study, the shutdown process was cptimized using the Pontryagin's maximum principle so that the shutdown mirth[d was improved as to restart the reactor to its fulpower at any time, but the xenon concentration did not excess the constrained allowable value during and after shutdown, at the same time all the control actions were completed within minimum time from beginning of the shutdown.

  • PDF

A Study on Safety Estimation of Railroad Wheel (컨테이너 철도차륜의 안전성 평가에 관한 연구)

  • Lee, Dong-Woo;Kim, Jin-Nam;Cho, Seok-Swoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1178-1185
    • /
    • 2010
  • Recently, high speed of container freight cars is causing fatigue damage of wheel. Sudden failure accidents cause a lot of physical and human damages. Therefore, damage analysis for wheel prevents failure accident of container freight car. Wheel receives mechanical and thermal loads at the same time while rolling stocks are run. The mechanical loads applied to wheel are classified by the horizontal load from contact of wheel and rail in curve line section and by the vertical force from rolling stocks weight. Also, braking and deceleration of rolling stocks cause repeated thermal load by wheel tread braking. Specially, braking of rolling stocks is frictional braking method that brake shoe is contacted in wheel tread by high breaking pressure. Frictional heat energy occurs on the contact surface between wheel tread and brake shoe. This braking converts kinetic energy of rolling stocks into heat energy by friction. This raises temperature rapidly and generates thermal loads in wheel and brake shoe. There mechanical and thermal loads generate crack and residual stress in wheel. Wetenkamp estimated temperature distribution of brake shoe experimentally. Donzella proposed fatigue life using thermal stress and residual stress. However, the load applied to wheel in aforementioned most researches considered thermal load and mechanical vertical load. Exact horizontal load is not considered as the load applied to wheel. Therefore, above-mentioned loading methods could not be applied to estimate actual stress applied to wheel. Therefore, this study proposed safety estimation on wheel of freight car using heat-structural coupled analysis on the basis of loading condition and stress intensity factor.

Matrix effect of Ti and Zr-2.5Nb sample for hydrogen analysis by Inert Gas Fusion-Thermal Conductivity Detection(IGF-TCD) Method (불활성기체용해-열전도도검출법에 의한 수소분석시 티타늄 및 지르코늄-2.5니오븀 시료의 매질효과)

  • Park, Soon-Dal;Choi, Ke-Chon;Kim, Jung-Suk;Kim, Jong-Gu;Joe, Kih-Soo;Kim, Won-Ho
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.261-268
    • /
    • 2003
  • To investigate the matrix effect of sample for hydrogen analysis by inert gas fusion-thermal conductivity detection, calibration factor for the hydrogen analyser of the inert gas fusion-thermal conductivity detection method was measured with hydrogen standard materials in Ti, Zr-2.5Nb and by hydrogen gas dosing method. Also the hydrogen extraction efficiency for the different sample matrix, Ti and Zr-2.5Nb, was evaluated without adding tin flux. The calibration factor of the hydrogen analyser which was calibrated by hydrogen standard material in Zr-2.5Nb and Ti was 2~3% and 14% higher than that by hydrogen gas dosing method, respectively. Based on the results of calibration factor measurement, it could be concluded that the hydrogen extraction efficiency of the Ti matrix sample will be 12% lower than that of the Zr-2.5Nb. And according to the experimental results of hydrogen recovery test by no tin flux, the hydrogen recovery percentage of the Ti and Zr-2.5Nb matrix sample was about 70% but the recovery rate of Ti matrix sample was slightly lower than that of Zr-2.5Nb.

An Experimental Study of the Bioelectrical Signals and Subjective Response in Changing from Unpleasant to Pleasant Temperatures in a Learning Environment (학습환경에서 불쾌적온도에서 쾌적온도로의 변화시 생체신호 및 주관적 반응에 대한 실험적 연구)

  • Im, Gwanghyun;Kim, Jinhyun;Park, Chasik;Cho, Honghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.596-602
    • /
    • 2015
  • In this study, experiments using bioelectronic signals and questionnaire surveys were carried out in learning conditions when temperatures changed from low- and high-uncomfortable to comfortable. As a result, the stress factor Photoplethysmography (PPG) decreased, while the Root Mean Square of Standard Deviation (RMSSD) of PPG increased when the indoor temperature was changed from low- or high-uncomfortable to comfortable. Additionally, the absolute power of the ${\alpha}$-wave in the brain increased. According to the analysis of the association between the questionnaire and bioelectronic signals, the standard deviation of the stress factor as measured by pulse was closely related to the result of the thermal sensation questionnaire. In addition, it was found that the concentration on studying improved under comfortable temperatures when compared to uncomfortable temperatures.