• Title/Summary/Keyword: thermal factor

Search Result 1,559, Processing Time 0.028 seconds

The Effect in Heat Controlling and Perceptions Towards Home Furnishing Fabrics - Focus on Curtains and Draperies - (주택에서 내장재로 쓰이는 섬유의 절약효과와 소비자의식에 관한 연구 - 커어튼을 중심으로 -)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.1
    • /
    • pp.65-77
    • /
    • 1982
  • The intent of this study was to focus attention on the relationship between curtain fabrics and consumer perceptions towards curtains and draperies. This study consisted of the laboratory test for thermal transmittance of selected fabrics and the exploratory survey for consumer perceptions towards curtains and draperies. The objectives of the laboratory test were to measure fabric's thermal transmittance, thickness, and count which affect to the effect in heat controlling. Selected 23 fabrics were tested at Korean Yarn and Fabrics Testing Inspection Institute. The objectives of the exploratory survey were to determine sociodemographic factors; the stage of family life cycle, the economics status, and homemaker's level of education, and physical factors; the type of houses, the direction of windows, and the type of windows, affect consumer perceptions toward curtains and draperies. Questionaires were administered to 489 homemakers selected by a stratified propotional sampling plan, in Seoul in October, 1981. Data from responses were analyzed by T-test(Analysis of Varience) and Partial Correlation. The major findings are as follows; 1. The results of the laboratory test 1) The fabrics used for draperies had higher effect in heat controlling than the fabrics used for glass curtains. 2) It did not show much differences among the fibers in heat controlling. The thicker fibers, however, had the higher effect in heat controlling among same fibers. 3) The fabrics which had high level of effect I heat controlling were corduroy, flax, rayon, nylon, acetate, thick polyester, and thick polyacrylic. The fabrics which had midium level of affect in heat controlling were velveteen, velvet, and thin polyester. The fabrics which had low level of effect in heat controlling were cotton, silk, and thin polyarcylic. 4) The draperies with lining showed 2∼5 times more effective in heat controlling than the draperies without lining. 2. The results of the exploratory survey Consumer perceptions towards curtains and draperies consisted of functional, financial, and aesthetic perception. 1) Factor affecting functional perception towards curtains and draperies was the stage of family life cycle. Families in the contracting stage considered function of curtains and draperies significantly better than those in others stages. 2) Factors affecting financial perception towards curtains and draperies were the economic status, homemaker's level of education, the direction of windows, and the type of windows. However the correlation between the factors and financial perception was too low to explain the significance of tendency. 3) There was not any factors affecting aesthetic perception towards curtains and draperies.

  • PDF

Cooling Performance on the Small Diesel Engine (소형(小型)디젤기관(機關)의 냉각성능(冷却性能)에 관(關)한 연구(硏究))

  • Kim, Sung Rai;Myung, Byung Soo
    • Korean Journal of Agricultural Science
    • /
    • v.17 no.1
    • /
    • pp.45-51
    • /
    • 1990
  • This study was conducted to obtain basic data for the design of cooling system by the test of engine performance of the power tiller being used widely in the rural area. Among the various factors affecting engine performance, the flow rate of cooling water was considered as the major factor in this study. Motoring loss, output, fuel consumption ratio, torque, heat absorption of cooling water, and thermal efficiency were measured and analyzed based on three flow rates of cooling water such as 15, 20, and $25{\ell}/min$. The results obtained were as follows : 1. Motoring loss of the engine was 1.371 kW at 2,200 rpm., and mechanical efficiency was 79.1% at rated output level. 2. Output power of the engine increased with the flow rate of cooling water increased. 3. BSFC was 282.9g/kW-h at the flow rate of $20{\ell}/min$, and the temperature of cooling water at outlet was $80.9^{\circ}C$. 4. There was a little variation of torque of the engine depending on the flow rate of cooling water. 5. Absorption of heat by cooling water was increased with the increase of flow rate. 6. The highest thermal efficiency of 32.3% at the flow rate of $20{\ell}/min$ was observed.

  • PDF

Emission Characteristics of PM10 and PM2.5 in Thermal Power Plants Using Different Fuel Types (연료별 화력발전시설의 미세먼지(PM10 및 PM2.5) 배출특성)

  • Park, Hyun-Soo;Lee, Duk-An;Yang, Jeong-Go;Jang, Seong-Guk;Kim, Hwan-Beom;Kim, Deug-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.4
    • /
    • pp.534-541
    • /
    • 2018
  • Concentrations of total particulate matter (TPM), $PM_{10}$ and $PM_{2.5}$ were measured at three different sites based on each different fuel type (solid, liquid and gas) used in thermal power plants operating in Yeosu and Gwangyang National Industrial Complexes during 2017. The highest concentrations of TPM, $PM_{10}$, and $PM_{2.5}$ were observed at the solid fuel facility, and these values were $3.356mg/Sm^3$, $2.342mg/Sm^3$ and $1.834mg/Sm^3$, respectively. The ratio of $PM_{2.5}$ to TPM was the highest value of 54.6% in solid fuel case, and the lowest was 35.7% found in liquid fuel case. As a result of analyzing 9 kinds of metal compound with respect to each particle size, the metal concentration of TPM is higher than those of $PM_{10}$ and $PM_{2.5}$ in all fuel types. Total concentrations of metal elements in TPM by fuel difference are $1.2702mg/Sm^3$ in solid fuel, 0.0603 mg/Sm3 in liquid fuel, and $0.0733mg/Sm^3$ in gas fuel, respectively. Relatively higher total metal concentration in gas fuel than in liquid fuel was found; and this could be higher Cr and Al concentrations in use of gas fuel. As a result of estimating the emission factors of each facility, in case of solid fuel, TPM emissions per electricity production were found to be 0.7080 kt/PJ, followed by liquid fuel and gas fuel. $PM_{10}$ and $PM_{2.5}$ emissions per hour of electricity production were similar to those of TPM.

Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology (Bulk fill 유동성 복합레진의 변연 누출에서 다른 중합시간의 영향에 대해 마이크로시티를 이용한 평가)

  • Kim, Eun-Ji;Lee, Kyu-Bok;Jin, Myoung-Uk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.184-193
    • /
    • 2016
  • Purpose: To evaluate marginal leakage of bulk fill flowable composite resin filling with different curing time by using microcomputed tomography technology. Materials and Methods: 30 previously extracted human molars were randomly divided into 6 groups based upon restorative system and different curing time. Class II cavities (vertical slot cavities) were prepared. An individual metallic matrix was used to build up the proximal wall. The SonicFill or SureFil SDR flow was inserted into the preparation by using 1 bulk increment, followed by light polymerization for different curing times. The different exposure times were 20, 40, and 60 seconds. All specimens were submitted to 5,000 thermal cycles for artificial aging. Micro-CT scanning was performed by using SkyScan 1272. One evaluator assessed microleakage of silver nitrated solution at the resin-dentin interface. The 3D image of each leakage around the restoration was reconstructed with CT-Analyser V.1.14.4. The leakage was analyzed with the Mann-Whitney test. Results: Significant differences were observed between the light curing times, but no significant differences were found between the bulk fill composite resins. Increasing in the photoactivation time resulted in greater microleakage in all the experimental groups. Those subjected to 60 seconds of light curing showed higher microleakage means than those exposed for 20 seconds and 40 seconds. Conclusion: Increasing the photoactivation time is factor that may increase marginal microlekage of the bulk fill composite resins. Further, micro-CT can nondestructively detect leakage around the resin composite restoration in three dimensions.

Study on the Pyrolysis Kinetics of Deasphalted Oil Using Thermogravimetric Analysis (열중량 분석법을 이용한 Deasphalted Oil의 열분해 특성 분석)

  • Shin, Sang Cheol;Lee, Jung Moo;Lee, Ki Bong;Jeon, Sang Goo;Na, Jeong Geol;Nho, Nam Sun
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.391-397
    • /
    • 2012
  • The depletion of conventional oil reserves and the increasing energy need in developing countries such as China and India result in exceeding oil demand over supply. As a solution of the problem, the efficient utilization of heavy oil has been receiving more and more interest. In order to utilize heavy oil, upgrading processes are required. Among the upgrading processes, thermal decomposition is thought to be relatively simple and economical. In this study, to understand basic characteristics of thermal decomposition of heavy oil, we conducted pyrolysis experiments of deasphalted oil (DAO) produced by a solvent deasphalting process. DAO is a mixture of many components and consists mainly of materials of carbon number 20~40. For the comparison with results of DAO pyrolysis, additional pyrolysis experiments with single materials of carbon number 30 ($C_{30}H_{62}$, $C_{30}H_{58}O_4S$, $C_{30}H_{63}O_3P$) were conducted. Pyrolysis experiments were carried out non-isothermally with variation of heating rate (10, 50, $100^{\circ}C$/min) in a thermogravimetric analyzer. Average pyrolysis activation energy determined by using Arrhenius method, Ingraham and Marrier method, and Coats and Redfern method was 72~99 kJ/mol. In the activation energy calculated by Ozawa-Flynn-Wall method, DAO had wider variation than other single materials.

Analysis of Heat Transfer Characteristics Based on Design Factors for Determining the Internal Geometry of Metal Insulation in Nuclear Power Plant (원전용 금속단열재의 내부 형상결정을 위한 설계인자 별 열전달 특성 분석)

  • Song, Ki O;Yu, Jeong Ho;Lee, Tae Ho;Jeon, Hyun Ik;Ha, Seung Woo;Cho, Sun Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1175-1181
    • /
    • 2015
  • A heat insulating material used in the industrial site normally derives its heat insulating performance by using a low thermal conductivity material such as glass fiber. In case of the metal insulation for nuclear power plant, in contrast, only TP 304 stainless steel foil having high thermal conductivity is the only acceptable material. So, it is required to approach in structural aspect to ensure the insulation performance. In this study, the design factors related to the metal insulation internal structure were determined considering the three modes of heat transfer, i.e., conduction, convection, and radiation. The analysis of heat flow was used to understand the ratio of the heat transfer from each factor to the overall heat transfer from all the factors. Based on this study, in order to minimize the convection phenomenon caused by the internal insulation, a multiple foil was inserted in the insulation. The increase in the conduction heat transfer rate was compared, and the insulation performance under the three modes of heat transfer was analyzed in order to determine the internal geometry.

The Study on Thermal Analysis and Thermodynamic Characteristics of Spinel Compounds(ZnCo2O4, NiCo2O4) (스피넬 구조를 가지는 전이금속화합물(ZnCo2O4, NiCo2O4)의 열적 분석 및 열역학적 특성 연구)

  • Kim, Jae-Uk;Ji, Myoung-Jin;Cha, Byung-Kwan;Kim, Chul-Hyun;Jang, Won-Cheoul;Kim, Jong-Gyu
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.2
    • /
    • pp.192-197
    • /
    • 2010
  • The spinel compound was obtained by the thermal decomposition of Zn-Co and Zn-Ni gel prepared by sol-gel method using oxalic acid as a chelating agent. The formation of spinel compound has been comfirmed by thermogravimetric analysis (TGA), x-ray powder diffraction (XRD) and infrared spectroscopy (IR). The particle size of 13 nm~16 nm was calculated by Scherrer's equation. The sol-gel method provides a practicable and effective route for the synthesis of the spinel compound at low temperature ($350^{\circ}C$). The kinetic parameters such as activation energy (Ea) and pre-exponential factor (A) for each compound were found by means of the Kissinger method and Arrhenius equation. The decomposition of spinel compound has an activation energy about 155 kJ/mol. Finally, the thermodynamic parameters (${\Delta}G^{\varphi}$, ${\Delta}H^{\varphi}$, ${\Delta}S^{\varphi}$) for decomposition of spinel compound was determined.

Generation of Land Surface Temperature Orthophoto and Temperature Accuracy Analysis by Land Covers Based on Thermal Infrared Sensor Mounted on Unmanned Aerial Vehicle (무인항공기에 탑재된 열적외선 센서 기반의 지표면 온도 정사영상 제작 및 피복별 온도 정확도 분석)

  • Park, Jin Hwan;Lee, Ki Rim;Lee, Won Hee;Han, You Kyung
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.36 no.4
    • /
    • pp.263-270
    • /
    • 2018
  • Land surface temperature is known to be an important factor in understanding the interactions of the ground-atmosphere. However, because of the large spatio-temporal variability, regular observation is rarely made. The existing land surface temperature is observed using satellite images, but due to the nature of satellite, it has the limit of long revisit period and low accuracy. In this study, in order to confirm the possibility of replacing land surface temperature observation using satellite imagery, images acquired by TIR (Thermal Infrared) sensor mounted on UAV (Unmanned Aerial Vehicle) are used. The acquired images were transformed from JPEG (Joint Photographic Experts Group) to TIFF (Tagged Image File Format) format and orthophoto was then generated. The DN (Digital Number) value of orthophoto was used to calculate the actual land surface temperature. In order to evaluate the accuracy of the calculated land surface temperature, the land surface temperature was compared with the land surface temperature directly observed with an infrared thermometer at the same time. When comparing the observed land surface temperatures in two ways, the accuracy of all the land covers was below the measure accuracy of the TIR sensor. Therefore, the possibility of replacing the satellite image, which is a conventional land surface temperature observation method, is confirmed by using the TIR sensor mounted on UAV.

Development of the computer program calculating the stress induced by various loads for buried natural gas pipeline (II) (매설 천연가스 배관의 제반하중에 의한 응력 계산용 프로그램 개발 (II))

  • Bang I.W.;Kim H.S.;Yang Y.C.;Kim W.S.;Oh K.W.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.2
    • /
    • pp.26-33
    • /
    • 1998
  • The thickness of buried gas pipeline is determined mainly with internal pressure and location factor according to the requirements of ANSI B3l.8. But the stress of buried gas pipeline is determined by not only internal stress but also external loads. The change of burying and environmental conditions, therefore, may result in increasing stress of pipeline. In order to avoid the decrease of safety degree resulting from change of environmental condition, the evaluation of stress level shall be necessary. The reliable equations have been developed for calculating stress of buried pipeline from internal pressure, earth load, vehicle load, ground subsidence. But they are very difficult to understand and use for non-specialist. For easy calculation of non-specialist, the new computer program to calculate stress of buried natural gas pipeline have been developed. The program can calculate maximum stress resulted from earth load, vehicle load, thermal load, four type ground subsidence. The stress is calculated by the equations and extrapolation of the graph resulted from FEM. In this paper, as the series of paper I, the operating method and the functions of the program is explained.

  • PDF

Development of State of Charge and Life Cycle Evaluation Algorithm for Secondary Battery (이차전지의 상태 감시 및 수명 예측 알고리즘 개발)

  • Park, Jaebeom;Kim, Byeonggi;Song, Seokhwan;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.369-377
    • /
    • 2013
  • This paper deals with the state of charge(SOC) and life cycle evaluation algorithm for lead-acid battery, which is essential factor of the electric vehicle(EV) and the stabilization of renewable energy in the smart grid. In order to perform the effective operation of the lead-acid battery, SOC and life cycle evaluation algorithm is required. Specific gravity with the change of electrolyte temperature inside battery case should be obtained to evaluate the SOC of lead-acid battery, however it is difficult to measure the electrolyte temperature of sealed type lead-acid battery. To overcome this problem, this paper proposes the equation of thermal transmission to compensate internal temperature of the lead-acid battery. Also, it is difficult to exactly evaluate the life cycle of battery, depending on the operation conditions of lead-acid battery such as charging and discharging state, self discharging rate and environmental issue. In order to solve the problem, this paper presents the concept for gravity accumulation of charge and discharge cycle, which is the value converted at $20^{\circ}C$. By using the proposed algorithm, this paper propose the test device based on the Labview software. The simulation results show that it is a practical tool for the maintenance of lead-acid battery in the field of industry.