• Title/Summary/Keyword: thermal discharge

Search Result 627, Processing Time 0.032 seconds

Numerical Simulation of the Water Temperature in the Al-Zour Area of Kuwait

  • Lee, Myung Eun;Kim, Gunwoo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.3
    • /
    • pp.334-343
    • /
    • 2019
  • The Al-Zour coastal area, located in southern Kuwait, is a region of concentrated industrial water use, seawater intake, and the outfall of existing power plants. The Al-Zour LNG import facility project is ongoing and there are two issues regarding the seawater temperature in this area that must be considered: variations in water temperature under local meteorology and an increase in water temperature due to the expansion of the thermal discharge of expanded power plant. MIKE 3 model was applied to simulate the water temperature from June to July, based on re-analysis data from the European Centre for Medium-Range Weather Forecasts (ECMWF) and the thermal discharge input from adjacent power plants. The annual water temperatures of two candidate locations of the seawater intake for the Al-Zour LNG re-gasification facility were measured in 2017 and compared to the numerical results. It was determined that the daily seawater temperature is mainly affected by thermal plume dispersion oscillating with the phase of the tidal currents. The regional meteorological conditions such as air temperature and tidal currents, also contributed a great deal to the prediction of seawater temperature.

Difference in Macrobenthic Community Structures at Thermal Effluent Discharge Areas of Two Nuclear Power Plants in Korea (원자력발전소의 온배수 배출해역에서 대형 저서동물 군집구조의 차이)

  • Maeng, Jun-Ho;Kim, Keun-Yong;Kim, Young Ryun;Shon, Myung Baek;Kim, Jin Hee;Son, Min Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.3
    • /
    • pp.157-165
    • /
    • 2015
  • This study investigated and compared sediment properties and macrobenthic community structures within heated effluent plumes at the discharge areas of Kori Nuclear Power Plant (KNPP) and Sinkori Nuclear Power Plant (SNPP) in Korea, which have different thermal effluent discharge systems. There were significant differences in sand, clay and organic carbon contents between sediments at the two discharge areas. Species richness and abundance of macrobenthos were higher at the SNPP discharge area than at that of the KNPP, although the values at both areas were comparable to previous studies in coastal areas of eastern Korea.

Investigation of Spark Discharge in Water as a Source of Mechanical Actuation

  • Taylor, Nathaniel D.;Fridman, Gregory;Fridman, Alexander;Dobrynin, Danil
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.258-258
    • /
    • 2014
  • Spark discharge in water generates shockwaves which have been utilized to generate mechanical actuation for potential use in pumping application. Discharge pulses of several microseconds generate shockwaves and vapor bubbles which subsequently displace the water for a period of milliseconds. Through the use of a sealed discharge chamber and metal bellow spring, the fluid motion can be used create an oscillating linear actuator. Continuous actuation of the bellow has been demonstrated through the use of high frequency spark discharge. Discharge in water forms a region of high electric field around the electrode tip which leads to the creation of a thermal plasma channel. This process produces fast thermal expansion, vapor and bubble generation, and a subsequent shockwave in the water which creates physical displacement of the water [1]. Previous work was been conducted to utilize the shockwave effect of spark discharge in water for the inactivation of bacteria, removal of mineral fouling, and the formation of sheet metal [2-4]. Pulses ranging from 25 to 40 kV and 600 to 900 A are generated inside of the chamber and the bellow motion is captured using a slow motion video camera. The maximum displacements measured are from 0.7 to 1.2 mm and show that there is a correlation between discharge energy input to the water and the displacement that is generated. Subsequent oscillations of the bellow are created by the spring force of the bellow and vapor in the chamber. Using microsecond shutter speed ICCD imaging, the development of the discharge bubble and spark can be observed and measured.

  • PDF

A Study on the removal of $NO_x$ by using Non-thermal Plasma Discharge (Non-thermal Plasma Discharge를 이용한 $NO_x$ 제거에 관한 연구)

  • 안정언;이석현;정용원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.419-420
    • /
    • 2001
  • 최근 산업설비 및 기타 시설에서 배출되는 유해가스의 배출허용 기준이 계속 강화되고 있으며 그 중에서도 NOx는 SOx와 함께 대기오염의 주된 원인으로 작용하고 있다. 국내에서도 이들 유해가스를 제거하기 위한 플라즈마 적용기술이 활발히 연구되었으며, 일부 기술은 상용화 단계에 있다. NOx 제거에 있어서 펄스 코로나 방전에 의한 전자의 생성은 유입되는 가스 및 공기에 충돌하여 반응성이 큰 다량의 이온, 원자 및 radical(N, O, OH, $O_3$등)을 생성한다. (중략)

  • PDF

Thermal Index for the Assessment of the Impacted Area by the Thermal Discharge from Nuclear Power Plant in Korea (원자력 발전소 온배수 피해역 산정을 위한 영향지수 시안)

  • Ro, Young-Jae
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2007
  • Thermal discharges from the nuclear power plants into neighboring Korean coastal waters have raised serious disputable arguments from the two parties of local fishermen and scientists involved since late 1970's. To meet the social demands and provide scientific and reasonable solutions, new set of standards have been established which will guide through measuring and processing the various variables and parameters in environmental and fishery impact assessment procedures for the thermal discharge from the nuclear power plants. These are made possible for the first time by the combined efforts by Korean Oceanography Society and Fishery Society. In this paper, Thermal Disharge Impact Index(TI) is proposed by the probability of the local temperatures exceeding critically to local fishery multiplied by the weighted sum of diverse environmental and ecological factors. The TI is essentially conceived to overcome the long-exising bad practices based on the particular excess temperature such as 1. The proposed TI based on the guideline principle proposed by the UNEP(2002) is expected to be practical, economic and self-adaptive. To prove the usefulness of the TI, it is highly recommended to conduct prototype experiments and exercises in a particular nuclear power plant site in the near future.

Temperature Distribution Monitoring of Transformer Using IRR-Camera (적외선방사카메라를 이용한 변압기 온도분포 모니터링)

  • 이우선;정찬문;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

Design of Thermal Vapor Compressor by Numerical Analysis and Experimental Verification (전산해석을 통한 열증기압축기 설계와 실험적 검증)

  • Park, Il-Seouk;Park, Sang-Min;Ha, Ji-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.6 s.33
    • /
    • pp.33-39
    • /
    • 2005
  • A thermal vapor compressor in which the subsonic/supersonic flow appears simultaneously, has been accurately designed through the CFD analysis for the various shape parameters such as the primary nozzle shape, converging duct shape, mixing tube diameter, and so on. The performance of the developed thermal vapor compressor has been experimentally verified to be installed in a Multi Effect Desalination(MED) plant as an important element. In this paper, the effects of each parameter are discussed on the basis of CFD results and the experimental results for various boundary conditions(motive pressure, suction pressure, and discharge pressure) are presented in compared with CFD results. The two results show a good agreement with each other within 2 % accuracy with regard to the entrainment ratio.

Temperature Distribution Monitoring of Transformer (변압기 온도 변화특성 모니터링)

  • Lee, Woo-Sun;Jung, Chan-Moon;Son, Dong-Min;Seo, Young-Jin;Lim, Jang-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

A Study on the efficiency test of Electric Discharge Machine Wire using Image processing (화상처리를 이용한 방전와이어의 성능평가에 대한 연구)

  • 배진한;이위로;유송민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.117-122
    • /
    • 2002
  • Electrical discharge machining uses thermal energy from electrical discharge, while wire electrical discharge machining (WEDM) technology is widely used in conductive material machining. This paper proposes a method for evaluating the characteristics of wires in WEDM. In order to evaluate the wire processing performance, processing speed and roughness, straightness, corner processing have been assessed with precision experiment equipment and image processing including Laplacian filtering with various threshold levels.

  • PDF

RELAP5/MOD3 Analysis for Hydraulic Load Calculation of the SEBIM POSRV Discharge Riping System (SEBIM POSRV 방출배관계통의 수력학적 하중계산을 위한 RELAP5 / MOD3 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.225-236
    • /
    • 1994
  • The sudden discharge of the loop seal water, which is present upstream of the SEBIM POSRV, creates large momentum and inertia forces on the downstream of the discharge piping system. This study provides the procedures and results of analysis of the thermal-hydraulic transient in the SEBIM POSRV discharge piping during the valve opening. The analysis is peformed by RELAP5/MOD3. The appropriate modeling of the discharge piping system, SEBIM POSRV opening characteristics, and loop seal water discharge for the RELAP5/MOD3 analysis is suggested. Also performed is the sensitivity study for the selection of proper options for the junction and volume control. flags. The analysis results demonstrate the adequacy of the RELAP5/HOD3 for the thermal-hydraulic transient analysis of the loop seal water discharge of the SEBIM POSRV discharge piping system. From the sensitivity analysis results, it is shown that the smooth area change option with reasonable geometric pressure drop distribution, non-equilibrium option, and proper time step should be selected for loop seal water discharge analysis.

  • PDF