• Title/Summary/Keyword: thermal degradation pattern

Search Result 15, Processing Time 0.022 seconds

Thermal Degradation Pattern of Tocopherols on Heating without Oxygen in a Model Food System (모델식품계에서 무산소 가열시 토코페롤의 열분해 패턴)

  • 정혜영
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.6
    • /
    • pp.635-639
    • /
    • 1998
  • The thermal degradation pattern of $\alpha$-, ${\gamma}$-and $\delta$-tocopherols in glycerol was investigated during heating at 100~25$0^{\circ}C$ for 5-60 min in the absence of oxyge. The tocopherols and thermally decomposed products were separated by HPLC with a reversed phase $\mu$-Bondapak C18-column. The degradation pattern of $\alpha$-tocopherol during the heating in the absence of oxygen was different from those of ${\gamma}$-and $\delta$-tocopherols. But the degradation patterns of ${\gamma}$-and $\delta$-tocopherols were similar to each other. The residual content of $\alpha$-tocopherol during the heating in the absence of oxygen decreased to the range 12~65% and those of ${\gamma}$-and $\delta$-tocopherols decreased to the range 4~96%. The thermal degradation of tocopherols in the absence of oxygen was less than that in the presence of oxygen.

  • PDF

Temperature Distribution Monitoring of Transformer Using IRR-Camera (적외선방사카메라를 이용한 변압기 온도분포 모니터링)

  • 이우선;정찬문;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

Temperature Distribution Monitoring of Transformer (변압기 온도 변화특성 모니터링)

  • Lee, Woo-Sun;Jung, Chan-Moon;Son, Dong-Min;Seo, Young-Jin;Lim, Jang-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

Analysis of Alizarin Dye in Accelerated Degradation Conditions

  • Ahn, Cheunsoon
    • The International Journal of Costume Culture
    • /
    • v.7 no.1
    • /
    • pp.40-47
    • /
    • 2004
  • The purpose of this research was to examine the degradation rate of alizarin in accelerated degradation conditions using the GC-MS quantitative analysis. Alizarin dye solution (2.5 x 10/sup -3/ M conc.) were kept in 150℃ oven for total of 7 days and the degradation rate was examined each day. 2.5 × 10/sup -4/M conc. alizarin dye solution was mixed with H₂O₂ according to [H₂O₂]/[dye] ratio 40 and were kept under 365㎚ UV for 2 hours, analyzed after 0, 30, 60, 90, 120min using the GC-MS. Gas chromatogram showed alizarin peak at 9.96 - 10.13 min. retention time range and residual peaks in the wide range from 9.6 to 11.1 min. Oven degradation exhibited an initial decrease in the amount of alizarin, which was followed by increasing amount in 4/sup th/ day. The decrease in the alizarin was significantly shown by the 7/sup th/ day. Same pattern was also observed in the H₂O₂/UV/O₂ degradation samples and was verified ed by the UV-VIS spectra. The differences in the amount of alizarin between 1/sup st/ day and 4/sup th/ day samples, 4/sup th/ day and 7/sup th/ day samples, and Control and 7/sup th/ day samples of the oven degradation were significant at alpha .20.

  • PDF

Enhanced Thermal Stability of a Novel Human Thrombopoietin Mutein under the Various Temperature Conditions

  • Kim, Tae-Soo;Ahn, Hye-Kyung;Lim, Seung-Wook;Hong, Yeon-Joo;Chung, Joo-Young;Koh, Yeo-Wook
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.237.2-237.2
    • /
    • 2003
  • DWP40458 is a novel human thrombopoietin mutein with two additional N-linked glycosylation site. The thermal stability of DWP40458 in both solution and lyophilized form was studied in the temperature range of 4-50$^{\circ}C$, compared with recombinant human TPO (rhTPO). When the aggregation or degradation pattern of DWP40458 and rhTPO solution was characterized by using SDS-PAGE, gel permeation chromatography (GPC) and reverse phase HPLC, it was found that thermostability of DWP40458 was significantly different to rhTPO in the temperature at 25, 40, 40, 50$^{\circ}C$. (omitted)

  • PDF

A study on the On-Line Diagnostic Technique of High Voltage Induction Motor by partial discharge Pattern Analysis (부분방전 패턴분석에 의한 고압유도전동기 무정전 진단기법 연구)

  • Jung, Young-Ill;Lee, Eun-Suk;Kim, Duck-Keun;Lim, Yung-Bae;Kim, Jong-Seo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1685-1687
    • /
    • 2002
  • High voltage(H.V.) induction motors have been applied to various industrial applications. But aging and failure of induction motors are initiated by electrical, mechanical, thermal and chemical processes during manufacturing or in-service. These detects reduce locally the dielectric strength of the insulation. At such defects partial discharges can occur, which cause further degradation of the insulation and reduce the life time of the H.V induction motors. Consequently in this paper, we studied the partial discharge pattern analysis of H.V. induction motor for on-site applications.

  • PDF

A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis (가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구)

  • Ah-Reum, Kim;Byeong Sub, Kwak;Tae-Hyun, Jun;Hyun-joo, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

Thermal Pattern Comparison between 2D Multicore Processors and 3D Multicore Processors (2차원 구조와 3차원 구조에 따른 멀티코어 프로세서의 온도 분석)

  • Choi, Hong-Jun;Ahn, Jin-Woo;Jang, Hyung-Beom;Kim, Jong-Myon;Kim, Cheol-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.9
    • /
    • pp.1-10
    • /
    • 2011
  • Unfortunately, in current microprocessors, increasing the frequency causes increased power consumption and reduced reliability whereas it improves the performance. To overcome the power and thermal problems in the singlecore processors, multicore processors has been widely used. For 2D multicore processors, interconnection is regarded as one of the major constraints in performance and power efficiency. To reduce the performance degradation and the power consumption in 2D multicore processors, 3D integrated design technique has been studied by many researchers. Compared to 2D multicore processors, 3D multicore processors get the benefits of performance improvement and reduced power consumption by reducing the wire length significantly. However, 3D multicore processors have serious thermal problems due to high power density, resulting in reliability degradation. Detailed thermal analysis for multicore processors can be useful in designing thermal-aware processors. In this paper, we analyze the impact of workload distribution, distance to the heat sink, and number of stacked dies on the processor temperature. We also analyze the effects of the temperature on overall system performance. Especially, this paper presents the guideline for thermal-aware multicore processor design by analyzing the thermal problems in 2D multicore processors and 3D multicore processors.

Structural and thermal characteristics of photocrosslinked silk fibroin - PEG hydrogel

  • Jo, You-Young;Lee, Kwang-Gill;Bragg, John C.;Lin, Chien-Chi;Kweon, HaeYong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.32 no.1
    • /
    • pp.35-40
    • /
    • 2016
  • Hydrogels are crosslinked hydrophilic matrices for a variety of biomedical applications. Silk fibroin (SF), one of typical natural biomaterials, has been explored as base material for hydrogel. Photocrosslinked SF hydrogel containing poly(ethylene glycol) (PEG) was formulated through visible light initiated thiol-acrylate photopolymerization. The morphological, structural and thermal properties of SF - PEG hydrogel was investigated through scanning electron microscopy, X-ray diffractometry, thermogravimetry, and differential scanning calorimetry. The morphology of SF hydrogel showed dot and uneven surface with network cross-section. X-ray diffraction curves showed that the specific diffraction peaks of PEG were not changed by the intensity of the peaks were affected by sonication. Thermo-degradation behavior of SF - PEG hydrogel sonicated was significantly affected and became complex pattern compared to unsonicated ones. However, the melting endothermic temperature of SF - PEG hydrogel was not changed but the crystalline enthalpy was decreased by gelation and sonication.

Thermal Decomposition of A New Insecticide KH-502 [O, O-Diethyl O-(1-phenyl -3-trifluoromethy-5-pyrazoyl) thiophosphoric acid ester] (신규(新規) 살충제(殺蟲劑)인 O, O, O-Diethyl-O-(1-phenyl-3-trifluoromethyl-5-pyrazoyl) thiophosphoric acid ester의 열(熱)에 의한 분해성(分解性))

  • Cho, Boo-Yeon;Han, Dae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.3
    • /
    • pp.225-234
    • /
    • 1992
  • Thermal decomposition was conducted to investigate the influence of the various factors on stability of a new insecticide, [O, O-Diethyl O-(1-phenyl-3-trifluoromethyl-5-pyrazoyl) thiophosphoric acid ester : KH-502], in view of those informations applicable for industrial exploitation. In the thermal decomposition experiment, KH-502 was, after mixing with Fe, Cu and adjustment of moisture and pH conditions, subjected to three temperatures, 25, 50, and $100^{\circ}C$. Results for stability, and degradation pattern of KH-502 from the above experiment can be summarized as follows: 1. Main products of the thermal decomposition when this was conducted in the closed system were identified as following five compounds:O, O, O-Triethylthiophosphoric acid(TEPA), 1-Phenyl-3-trifluoromethyl-5-ethoxypyrazole(PTMEP), 1-Phenyl-2-ethyl-3-trifluoromethyl-5-hydroxypyrazole(PETMHP), O, O-Diethyl O-(1-phenyl-3-trifluoromethyl-5-pyrazoyl)phosphoric acid ester(KH-502 oxo form), O, S-Diethyl O-(1-phenyl-3-trifluoromethyl-5-pyrazoyl)phospho rothiolate(S-ethyl KH-502). However, compounds such as oxo form and S-ethyl KH-502 were not identified when the thermal decomposition was proceeded in the open system. 2. KH-502 was stable at 25 and 50$^{\circ}C$, but it was decomposed at 100$^{\circ}C$ following the first-order kinetics at the early stages of decomposition. 3. Rate constants for the thermal decomposition of KH-502 at 100$^{\circ}C$ were in the orders of Cu powder addition 0.344>Cu plate addition 0.21>moisture addition 0.05>closed system=open system=iron addition=pH 5.5 adjustment 0.04>pH 8.5 adjustment 0.027 day$^{-1}$, representing KH-502 was decomposed fast at Cu powder treatment and slow at pH 8.5 adjustment. 4. Half-life for the thermal decomposition of KH-502 at 100$^{\circ}C$ was in the orders of Cu powder addition 2.02

  • PDF