• 제목/요약/키워드: thermal damages

검색결과 133건 처리시간 0.029초

원자력발전소의 온배수 배출량을 고려한 어업생산감소율 추정 모델 (A Quantitative Model for Estimating Fishery Production Damages as a Result of Thermal Effluents from Nuclear Power Plants)

  • 장창익;이성일;이종희
    • 한국수산과학회지
    • /
    • 제42권5호
    • /
    • pp.494-502
    • /
    • 2009
  • A quantitative model was developed in order to estimate fishery production damage due to anthropogenically induced environmental changes. The model is described in the following equation, $Y_D=\frac{{\phi}_D}{{\phi}_G}[Y_0{\cdot}(t_p-t_0)-\frac{Y_0}{{\phi}_G}(1-e^{-{\phi}_G(t_p-t_0)})]$, where, $Y_D$ is annual amount of fishery production by nuclear power plant. ${\varphi}$ D and ${\varphi}$ G are instantaneous decreasing coefficient of fishery production by nuclear power plant and instantaneous decreasing coefficient of gross fishery production, respectively. $Y_0$ is annual mean fishery production without damages. $t_p$ is the present time, and $t_0$ is the starting time of damages. The model was applied to fishing grounds near a nuclear power plant on the east coast of Korea. Since fishery production damages have become bigger with increasing emission of thermal effluents from generators activities in the power plant, this factor has also been considered as, $\delta_{D_i}=\delta_D\({\sum}\limits_{i=0}^{n}\;W_i/W_T\)$, where, $\delta_{Di}$ is the cumulative damage rate in fishery production from generators, $\delta_D$ is the total cumulative damage rate in fishery production, $W_i$ is the emission amount of thermal effluents by generator i, and n is the number of generators in the nuclear power plant. This model can be used to conduct initial estimates of fishery production damages, before more detailed assessments are undertaken.

열해현상 방지를 위한 버스 엔진룸 구조개선 (Reengineering of Bus Engine Room Structure for Preventing Thermal Damages)

  • 맹주성;윤준용;손한규
    • 한국자동차공학회논문집
    • /
    • 제8권3호
    • /
    • pp.46-55
    • /
    • 2000
  • Four types of different flow inlet models were tested to improve the flow uniformity at the inlet of the radiator and to prevent thermal damages of auxiliary units from the hot air in the bus engine room. Measurements and numerical calculations were performed and their results were in a good agreement with each other. Simultaneously temperature measurements were carried out under the conditions of actual bus driving. As designing the new flow inlet at the partition board which seperates the engine space and radiator space, flow circulation can be achieved and fresh air comes into the engine room from the bottom. It was proved that new inlet makes the one air temperature cooling down in the engine room, the other uniformity improvement.

  • PDF

증기 동력기관 내 배관시스템의 열응력 해석 (Thermal Stress Analysis of Piping Systems in Steam-driven Power Engines)

  • 김찬희;정희택;배진수;정인수;이석순
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.35-42
    • /
    • 2009
  • The piping systems in the steam-driven power engines lie under the cyclic condition of thermal expansion and contraction by superheated steam. These phenomena might cause some severe damages on the pipes and the accessory devices. To avoid these damages, the calculation of the proper strength and the consideration of the reduced resultant forces on the materials are needed. In the present study, numerical investigations on the effects of the thermal deformation of the industrial piping system were performed with comparison of the design data. Commercial software, ABAQUS with the thermal-fluidic loadings based on the design conditions was used for the thermal stress analysis of the piping system. From the analysis of the initially-designed pipe supporters, the rearrangement was suggested to improve the piping design.

  • PDF

Comparative Study of Linear and Nonlinear Ultrasonic Techniques for Evaluation Thermal Damage of Tube-Like Structures

  • Li, Weibin;Cho, Younho;Li, Xianqiang
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.1-6
    • /
    • 2013
  • Ultrasonic guided wave techniques have been widely used for long range nondestructive detection in tube-like structures. The present paper investigates the ultrasonic linear and nonlinear parameters for evaluating the thermal damage in aluminum pipe. Specimens were subjected to thermal loading. Flexible polyvinylidene fluoride (PVDF) comb transducers were used to generate and receive the ultrasonic waves. The second harmonic wave generation technique was used to check the material nonlinearity change after different heat loadings. The conventional linear ultrasonic approach based on attenuation was also used to evaluate the thermal damages in specimens. The results show that the proposed experimental setup is viable to assess the thermal damage in an aluminum pipe. The ultrasonic nonlinear parameter is a promising candidate for the prediction of micro-damages in a tube-like structure.

Nonlocal heat conduction approach in biological tissue generated by laser irradiation

  • Abbas, Ibrahim A.;Abdalla, Aboelnour;Sapoor, Hussien
    • Advances in materials Research
    • /
    • 제11권2호
    • /
    • pp.111-120
    • /
    • 2022
  • A novel nonlocal model with one thermal relaxation time is presented to investigates the thermal damages and the temperature in biological tissues generated by laser irradiations. To obtain these models, we used the theory of the non-local continuum proposed by Eringen. The thermal damages to the tissues are assessed completely by the denatured protein ranges using the formulations of Arrhenius. Numerical results for temperature and the thermal damage are graphically presented. The effects nonlocal parameters and the relaxation time on the distributions of physical fields for biological tissues are shown graphically and discussed.

리튬이온 배터리의 분리막 손상 요인별 방전펄스의 검출과 분석 (Detection and Analysis of Discharge Pulses by Failure Mechanisms of the Separator inside Lithium-Ion Batteries)

  • 임승현;이경렬;김남훈;김동언;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제34권5호
    • /
    • pp.327-332
    • /
    • 2021
  • Lithium-ion batteries (LIBs) have become a main energy storage device in various applications, such as portable appliances, renewable energy facilities, and electric vehicles. However, the poor thermal stability of LIBs may cause explosion or fire. The thermal runaway is the result of a failure of the separator inside LIB. Damages like tearing, piercing, and collapsing of the separator were simulated in a mechanical, an electrical, and a thermal way, and small discharge pulses of a few mV were detected at the time of separator damages. From the experimental results, this paper provided a method that can identify the separator failure before thermal runaway in the aspect of a potential explosion and fire prevention measures.

Effects of Process Induced Damages on Organic Gate Dielectrics of Organic Thin-Film Transistors

  • Kim, Doo-Hyun;Kim, D.W.;Kim, K.S.;Moon, J.S.;KIM, H.J.;Kim, D.C.;Oh, K.S.;Lee, B.J.;You, S.J.;Choi, S.W.;Park, Y.C.;Kim, B.S.;Shin, J.H.;Kim, Y.M.;Shin, S.S.;Hong, Mun-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1220-1224
    • /
    • 2007
  • The effects of plasma damages to the organic thin film transistor (OTFT) during the fabrication process are investigated; metal deposition process on the organic gate insulator by plasma sputtering mainly generates the process induced damages of bottom contact structured OTFTs. For this study, various deposition methods (thermal evaporation, plasma sputtering, and neutral beam based sputtering) and metals (gold and Indium-Tin Oxide) have been tested for their damage effects onto the Poly 4-vinylphenol(PVP) layer surface as an organic gate insulator. The surface damages are estimated by measuring surface energies and grain shapes of organic semiconductor on the gate insulator. Unlike thermal evaporation and neutral beam based sputtering, conventional plasma sputtering process induces serious damages onto the organic surface as increasing surface energy, decreasing grain sizes, and degrading TFT performance.

  • PDF

지역난방용 축열조의 단열재 손상과 외각부식 개선방안 (Prevention of Insulation Damage Layer and Shell Corrosion in Thermal Storage Tanks for District Heating)

  • 방용운;유호선
    • 플랜트 저널
    • /
    • 제10권4호
    • /
    • pp.35-41
    • /
    • 2014
  • 축열조는 집단에너지를 공급하는 지역의 고도와 열부하에 따라 높이와 용량이 결정된다. 이는 축열조의 수두를 이용하여 열배관망에 압력을 가하고 배관망내의 비등을 방지하며 온도변화에 따라 체적이 팽창하면 이를 흡수하고 수축 시에는 부족한 중온수를 배관망에 공급하는 기능을 해야 하기 때문이다. 또한, 축열조의 역할은 주로 열수요량의 변화가 심한 계절별 주간 야간 시간대에 적절한 용량을 갖추고 잉여 열량을 저장한 후 필요한 시간대에 지역난방 열원으로 이용하면 열생산 설비의 운전 조건에 영향을 받지 않으면서 독자적으로 지역난방 열수요를 공급할 수 있는 장점이 있다. 본 연구는 지역난방에 건설되어 운영 중인 축열조 27기 중 폴리우레탄 폼의 단열 재료로 시공된 18기의 축열조에 대하여 단열재의 재질과 축열조의 운전방법에 따른 단열재의 손상원인에 대한 고찰과 단열재 손상이 축열조 부식에 어떠한 영향을 미치는지 고찰하였다.

  • PDF

X-ray and Plasma Process Induced Damages to PLZT Capacitor Characteristics for DRAM Applications

  • Kim, Jiyoung
    • The Korean Journal of Ceramics
    • /
    • 제3권3호
    • /
    • pp.213-217
    • /
    • 1997
  • In this paper, the imparct of X-ray and plasma process-induced-damages to La doped Lead Zirconate Titanate (PLZT, (Pb1-xLa)(Zr0.5Ti0.5)O3) capacitor characteristics have been investigated from the viewpoint of gigabit scale dynamic random access memory (DRAM) applications. Plamsa damage causes asymmetric degradation on hysteresis characteristics of PLZT films. On the other hand, X-ray damage results in a symmetrical reduction of charge storage densities (Qc's) for both polarities. As La concentration increases in the films, the radiation hardness of PLZT films on X-ray and plasma exposures is improved. It is observed that the damaged devices are fully recovered by thermal annealing under oxygen ambient.

  • PDF

장기 신뢰성 평가를 위한 태양전지의 열충격 시험 특성에 관한 연구 (The Study on Thermal Shock Test Characteristics of Solar Cell for Long-term Reliability Test)

  • 강민수;김도석;전유재;신영의
    • 에너지공학
    • /
    • 제21권1호
    • /
    • pp.26-32
    • /
    • 2012
  • 본 연구에서는 PV(photovoltaic)모듈에서 경년에 따른 효율 저하의 원인을 분석하기 위해 셀 레벨에서의 열충격 시험을 수행하였다. 열충격 시험의 조건은 $-40^{\circ}C$에서 $85^{\circ}C$로 각각 15분씩 30분을 1사이클로 하였으며, 열충격 시험 500 사이클 동안 100 사이클 간격으로 EL분석 및 I-V분석을 수행하였다. 효율 감소율은 단결정 Bare Cell이 8%, Solar Cell이 9%였으며, 다결정 Bare Cell이 6%, Solar Cell이 13%의 감소율을 보였다. 열충격 시험 후 Solar Cell은 표면 손상으로 인한 효율저하를 확인할 수 있었다. Bare Cell의 경우 표면의 손상이 없었지만, 효율이 저하된 것을 확인할 수 있었다. 이는 Fill Factor 분석에 의해 경년 시 나타나는 누설전류에 의한 소모전력 증가로 효율 저하에 영향을 준 것으로 판단된다. 또한, Bare Cell보다 Solar Cell에서의 효율 감소율이 상대적으로 높게 나타난 결과는 표면 손상 및 소모 전력의 증가로 인해 Solar Cell 효율에 큰 영향을 미치는 것으로 판단된다. 향후 단면 분석법 및 다양한 조건의 시험 기법을 활용하여 PV모듈 뿐 아니라 Cell 레벨에서의 불규칙한 효율 및 Fill Factor의 감소 원인을 검토하고, Solar Cell에서의 효율 저하가 가속되는 원인에 대한 대책 방안 연구가 수행되어야 할 것이다.