An Experimental Study on the Long-Term Performance Variation of the Plate-Type Enthalpy Exchange Element Made of Paper (판형 종이 재질 전열교환 소자의 장기 성능 변화에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.4
    • /
    • pp.165-170
    • /
    • 2016
  • Long-term performance of the enthalpy exchange element is a topic of current interest due to the concern of possible performance degradation over time. In this study, a 350 CMH enthalpy recovery ventilator equipped with an enthalpy exchange element was installed in an office room, and the performance has been traced over the past 5 years. The appearance, overall dimension, thermal performance, leakage ratio and anti-bacterial performance were checked annually. Results showed that the change in thermal performance (sensible, latent and enthalpy efficiency) was negligible with periodic cleaning with an air gun. However, the leakage ratio increased with time, measuring 7.3% after 5 years. Anti-bacterial test revealed that no bacteria were found during the test period. The largest change in the dimension occurred at the middle location of the element, although the change was less than 2% of the initial value.

A Study on the determination of the initial torque in tightening set screw of the drum assembly in VCR (VCR Drum 조립체의 고정나사 체결 Torque 결정에 관한 연구)

  • Son, Young-Gap;Kim, Jae-Jung;Back, Seung-Jun;Chang, Seog-Weon;Ryu, Dong-Su
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.333-338
    • /
    • 2000
  • This paper presents an experimental study and numerical thermal deformation analysis in the home appliance, Video Cassette Recorder. Analyzing the change axial force of a set screw according to the change of temperature in the drum assembly, we can determine the initial torque in tightening set screw. The torque will have the preload boss not be separated from the bearing. Also we conduct the fundamental experiment to constitute a boundary condition of the numerical analysis. With the result of this study, we can change the material of preload boss, copper, for aluminum.

  • PDF

A Study on Select Bearing Position of High Speed Spindle Considering the Thermo Behavior (주축의 열변위를 고려한 초고속 스핀들의 베어링 위치 선정)

  • Park, Su-Seong;Chung, Won-Jee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.6
    • /
    • pp.767-772
    • /
    • 2011
  • The thermal deformation of machine tool spindle influences the performance of the manufacturing systems for precision products. According to previous studies, major factors that will affect the stiffness of the spindle include spindle diameter, elasticity of the material, bearing stiffness and bearing span. It is difficult to change spindle diameter or elasticity of the material. but change of bearing position is easy in the given range compared to other factors. In this paper, we will find a solution to minimize thermal deformation through Change the span of the bearing.

A study on characteristics of crystallization according to changes of top structure with phase change memory cell of $Ge_2Sb_2Te_5$ ($Ge_2Sb_2Te_5$ 상변화 소자의 상부구조 변화에 따른 결정화 특성 연구)

  • Lee, Jae-Min;Shin, Kyung;Choi, Hyuck;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.80-81
    • /
    • 2005
  • Chalcogenide phase change memory has high performance to be next generation memory, because it is a nonvolatile memory processing high programming speed, low programming voltage, high sensing margin, low consumption and long cycle duration. We have developed a sample of PRAM with thermal protected layer. We have investigated the phase transition behaviors in function of process factor including thermal protect layer. As a result, we have observed that set voltage and duration of protect layer are more improved than no protect layer.

  • PDF

Melting of Ice Inside a Horizontal Cylinder under the Volume Change (수평원관내 체적변화를 고려한 얼음의 용용시 전열특성에 관한 연구)

  • 조남철;김동춘;이채탈;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1266-1274
    • /
    • 2001
  • Heat transfer phenomena during melting process of the phase change material (ice) was studied by numerical analysis and experiments. In a horizontal ice storage tube, the natural convection caused an increase in melting rate. However, the reduction of the heating surface area caused a decrease in melting rate. Therefore, during the melting process of ice in a horizontal cylinder, the reduction of the heating surface area should be considered. Under the same heating wall and initial water temperature condition, the melting rate became higher for $V_s/V_tot/=0.545 \;than \;that\; for\; V_s/V_tot$/=1.00 due to the difference in the reduction of heating surface area. A modified melting model considering the equivalent thermal conductivity of liquid phase and volume reduction was proposed. The results of the model were compared with the measured values and found to be in good agreement.

  • PDF

Showerhead Surface Temperature Monitoring Method of PE-CVD Equipment (PE-CVD 장비의 샤워헤드 표면 온도 모니터링 방법)

  • Wang, Hyun-Chul;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.16-21
    • /
    • 2020
  • How accurately reproducible energy is delivered to the wafer in the process of making thin films using PE-CVD (Plasma enhanced chemical vapor deposition) during the semiconductor process. This is the most important technique, and most of the reaction on the wafer surface is made by thermal energy. In this study, we studied the method of monitoring the change of thermal energy transferred to the wafer surface by monitoring the temperature change according to the change of the thin film formed on the showerhead facing the wafer. Through this research, we could confirm the monitoring of wafer thin-film which is changed due to abnormal operation and accumulation of equipment, and we can expect improvement of semiconductor quality and yield through process reproducibility and equipment status by real-time monitoring of problem of deposition process equipment performance.

Nodal method for handling irregularly deformed geometries in hexagonal lattice cores

  • Seongchan Kim;Han Gyu Joo;Hyun Chul Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.772-784
    • /
    • 2024
  • The hexagonal nodal code RENUS has been enhanced to handle irregularly deformed hexagonal assemblies. The underlying RENUS methods involving triangle-based polynomial expansion nodal (T-PEN) and corner point balance (CPB) were extended in a way to use line and surface integrals of polynomials in a deformed hexagonal geometry. The nodal calculation is accelerated by the coarse mesh finite difference (CMFD) formulation extended to unstructured geometry. The accuracy of the unstructured nodal solution was evaluated for a group of 2D SFR core problems in which the assembly corner points are arbitrarily displaced. The RENUS results for the change in nuclear characteristics resulting from fuel deformation were compared with those of the reference McCARD Monte Carlo code. It turned out that the two solutions agree within 18 pcm in reactivity change and 0.46% in assembly power distribution change. These results demonstrate that the proposed unstructured nodal method can accurately model heterogeneous thermal expansion in hexagonal fueled cores.

Estimating Sea Surface Temperature Change after Tide Embankment Construction using Landsat Data (방조제 건설에 의한 해수면 온도 변화 추정)

  • Shin, Dong-Hoon;Lee, Kyoo-Seock
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.4
    • /
    • pp.224-232
    • /
    • 2006
  • This study investigates to detect Sea Surface Temperature (SST) and land cover change after tide embankment construction using Landsat Thematic Mapper (TM) Thermal Infrared (TIR) band data at Shihwa Lake and surrounding area. SST measurement is important for studies of both the structure of the ocean and as the thermal boundary between the ocean and the atmosphere. Since 1970s, the derivation of SST by satellite remote sensing (RS) has been applied to earth surface using Advanced Very High Resolution Radiometer (AVHRR) and Landsat TM. However, AVHRR has restriction in deriving SST in the area whose shoreline is complicated like western coast in South Korea because of coarse spatial resolution. The TIR band of TM images can be used to detect SST change whose shoreline is complicated and narrow like the study site. Thus, multi-temporal TM images were used for SST change detection in this study.

  • PDF

Nondestructive evaluation of wall thinning covered with insulation using pulsed eddy current (펄스와전류를 이용한 보온재 비해체식 배관감육 평가기술)

  • Park, Duck-Gun;Babu, M.K.;Lee, Duk-Hyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.90-95
    • /
    • 2014
  • Local wall thinning is a point of concern in almost all steel structures such as pipe lines covered with a thermal insulator made up of materials with low thermal conductivity(fiberglass or mineral wool); hence, Non Destructive Technique(NDT) methods that are capable of detecting the wall thinning and defects without removing the insulation are necessary. In this study we developed a Pulsed Eddy Current(PEC) system to detect the wall thinning of Ferro magnetic steel pipes covered with fiber glass thermal insulator and shielded with Aluminum plate. The developed system is capable of detecting the wall thickness change through an insulation of thickness 10cm and 0.4mm aluminum shielding. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and coil sensor were used as a detecting element. In both cases, the results show a very good change corresponding to the thickness change of the test specimen. During these experiments a carbon steel tube of diameter 210mm and a length of 620mm, which is covered with insulator of 95mm thickness was used. To simulate the wall thinning, the thickness of the tube is changed for a specified length such as 2.5mm, 5mm and 8 mm from the inner surface of the tube. A 0.4mm thick Aluminum plate was covered on the Test specimen to simulate the shielding of the insulated pipelines. For both hall sensor and coil detection methods Fast Fourier transform(FFT) was calculated using window approach and the results for the test specimen without Aluminum shielding were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra. The PEC system can detect the wall thinning under the 95 mm thickness insulation and 0.4 mm Al shielding, and the output signal showed linear relation with tube wall thickness.

Analysis of Amur Cork Tree Extract and Dyed Silk upon Thermal Degradation Treatment (황벽 추출염료와 염직물의 열적 퇴화 거동 연구)

  • Ahn, Cheun-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.10
    • /
    • pp.1228-1241
    • /
    • 2011
  • This research compares the change in berberine content in liquid dye and the color and dye uptake of amur cork tree dyed silk upon thermal degradation treatment. Thermal degradation of amur cork tree extract and liquid dye of standard berberine was carried out at room temperature, $4^{\circ}C$ refrigeration, and $100^{\circ}C$ oven conditions for 0-192 hours. Amur cork tree dyed silk was treated in a $100^{\circ}C$ oven for 0-240 hours. The berberine content in liquid dye was measured by the relative abundance of the berberine peak in the HPLC-MS chromatograms. The color and dye uptake of dyed silk was measured using K/S value and colorimetric data. The berberine content in standard berberine dye was 2.4 times that of the amur cork tree extract. A similar result was observed between the K/S value of standard berberine dyed silk and that of amur cork tree dyed silk. The berberine dyed silk showed the highest dye uptake after 120 hours in a $100^{\circ}C$ oven. This result was similar to the change in a berberine content in liquid dye in a $100^{\circ}C$ oven treatment. The change of the K/S value of amur cork tree dyed silk and berberine content of amur cork tree extract was similar up to 24 hours. The result suggests that there is a direct relationship between the color change of amur cork tree dyed silk and the berberine content in amur cork tree dye.