• 제목/요약/키워드: thermal NO

검색결과 2,450건 처리시간 0.034초

Fabrication of $Ti(Al,\;O)-Al_2O_3$ Powder Feedstock for Thermal Spraying and Evaluation of the Composite Coating

  • Cao, Peng;Gabbitas, Brian;Zheng, Ling;Zhang, Deliang
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.49-50
    • /
    • 2006
  • [ $Ti(Al,\;O)-Al_2O_3$ ] composite powders were produced by high energy mechanical milling of a mixture of Al and $TiO_2$ powders followed by a combustion reaction. The powders were subsequently thermally sprayed on H13 steel substrates. Microstructural examination was conducted on the composite powders and thermally sprayed coatings, using X-ray diffractometry (XRD) and scanning electron microscopy (SEM). The performance of the coatings was evaluated in terms of micro-hardness and thermal fatigue. The thermally sprayed coatings performed very well in the preliminary thermal fatigue tests and showed no wetting tendency to molten aluminum.

  • PDF

무 구속·구속 실험에 의한 환풍기 온도 특성 (The Characteristic of Temperature in Ventilating Fans by Festraint or Nonrestraint)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.44-48
    • /
    • 2016
  • In this paper, we analyzed the operating characteristics of a ventilating fan due to overload and overheating. The experiment assumed the forcible restraint of the blade due to external objects and the aging process. We analyzed the experimental temperature and operating characteristics of the three places in the interior of the ventilating fan. As a result of the analysis, the temperature distribution was highest to lowest in the following order: the thermal fuse, the motor inside, and the above winding. There was smell of burning enamel in the restraint experiment. Following the thermal fuse operation, the insulation of motor winding was good. In the case of rated voltage and new ventilating fan restrained for about 4hours, and the results of restraint experiments in the presence or absence of the thermal fuse, no risk of deformation or fire due to overheating was identified. Henceforward, ignition hazard experiments will be required for additional factors of aging, pollution, and defective insulation.

Effect of Dry Process on Dielectric Properties of PZT Thin Films Prepared by Sol-Gel Process

  • Bae, Min-Ho;Lim, Kee-Joe;Kim, Hyun-Hoo;No, Kwang-soo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권1호
    • /
    • pp.42-45
    • /
    • 2002
  • Properties of lead zirconate titanate ferroelectric thin films prepared by rapid thermal annealing/direct insertion thermal annealing were investigated. The remnant polarization (Pr), saturation polarization (Ps), and coercive force (Ec) of typical samples annealed by rapid thermal annealing (RTA) are about 13.7 $\mu$ C/cm$^2$, 27.1 $\mu$C/cm$^2$, and 55.6 kV/cm, respectively. The dielectric constant of the sample is about 786, the dielectric loss tangent is about 2.4% at 1 kHz. Furthermore, ferroelectric, conduction, and piezoelectric properties of the thin films annealed by RTA process and the direct insertion thermal annealing (DITA) process were compared. The influence of temperature in the dry process on the above properties was also investigated.

알루미나계 자기애자의 장기 피로특성에 관한 연구 (Study on Long-term Deterioration Properties of Porcelain Insulators with Aluminous System)

  • 한세원;조한구;이동일;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.562-563
    • /
    • 2005
  • In case of aged porcelain, the failure in basic performance tests happened in cool-heat tests. Based on this characteristic, we studied the method predicting failure phenomena through more severe accelerated cool-heat ageing and accelerating thermal mechanical performance tests. Test results indicated that the thermal stress by temperature gradient was more severe parameter than thermal stress by quenching cycles within a category of standard or accelerating methods. And there is no the deterioration of statistic strength, but the deterioration of strength according to accelerating tests is serious.

  • PDF

매트 형태의 예혼합 촉매 버너에 의한 복사 건조 특성 (Drying Characteristics of a Radiative Industrial Dryer Adopting a Mat-Type Premixed Catalytic Burner)

  • 김혁주;안준;송광섭
    • 대한기계학회논문집B
    • /
    • 제35권7호
    • /
    • pp.735-742
    • /
    • 2011
  • 인체에 유해한 질소산화물($NO_x$)의 생성을 억제하면서 열효율을 높일 수 있는 새로운 버너의 개념으로 촉매 버너가 제안되었고 본 연구에서는 대표적인 에너지 다소비 설비인 건조기에 사용하기 위한 촉매버너를 개발하였다. 산업용 건조기에 활용하기 위해 촉매버너는 평평한 매트 형태로 제작되어 열전달 면적을 극대화하였고 밀폐 공간인 건조실에 활용하기 위하여 예혼합 연소방식을 적용하였다. 새로 개발된 촉매 버너를 산업용 건조기에 적용하여 실험한 결과 열에너지가 원적외선 형태로 공급되어 감율건조 영역에서 식품과 같은 유기물을 효과적으로 건조할 수 있음을 확인하였다. 또한 건조기의 열효율은 건조속도보다 피건조물의 함수율에 보다 큰 상관관계를 나타내었다.

유부하시의 열팽창분사식 소호부내의 상승압력 (Pressure Rise in the Thermal Expansion Chamber With Arc)

  • 박경엽;송기동;신영준;장기찬;김귀식;김진기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1344-1346
    • /
    • 1995
  • The interrupting capability of gas circuit breakers(GCB) are critically dependent on the pressure rise of the puffer cylinder or the thermal expansion chamber at current zero. Therefore it's very useful for the designers to know the pressure rise there at the design stage. Much effort has been done to predict the pressure rise in the puffer cylinder or the thermal expansion chamber in no-load condition. Thus, we now calculate it with reasonable accuracy with the simple programs coded by ourselves or with the commercial CFD packages. However, it has been still difficult problem to calculate it under the existence of arc. In this paper, we propose a method which can be used to predict the pressure rise in the thermal expansion chamber of thermal expansion type GCB. The method has been applied to the 25.8kV 25kA thermal expansion type model GCB and the calculated results have been compared with those from experiment.

  • PDF

복합응력이 작용하는 균열 배관에 대한 천이 크리프 조건에서의 C(t)-적분 예측 (I) - 탄성-크리프 - (Estimations of the C(t)-Integral in Transient Creep Condition for Pipe with Crack Under Combined Mechanical and Thermal Stress (I) - Elastic-Creep -)

  • 송태광;김윤재
    • 대한기계학회논문집A
    • /
    • 제33권9호
    • /
    • pp.949-956
    • /
    • 2009
  • The C(t)-integral describes amplitude of stress and strain rate field near a tip of stationary crack under transient creep condition. Thus the C(t)-integral is a key parameter for the high-temperature crack assessment. Estimation formulae for C(t)-integral of the cracked component operating under mechanical load alone have been provided for decades. However, high temperature structures usually work under combined mechanical and thermal load. And no investigation has provided quantitative estimates for the C(t)-integral under combined mechanical and thermal load. In this study, 3-dimensional finite element analyses were conducted to calculate the C(t)-integral of elastic-creep material under combined mechanical and thermal load. As a result, redistribution time for the crack under combined mechanical and thermal load is re-defined through FE analyses to quantify the C(t)-integral. Estimates of C(t)-integral using this proposed redistribution time agree well with FE analyses results.

열팽창을 고려한 특수 압력용기용 안전밸브 디스크의 설계에 관한 연구 (A Study on the Disc Design of a Safety-valve for the Specialized Pressure-vessel Considering Thermal Expansion)

  • 강재원;김창호;강동호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1581-1584
    • /
    • 2007
  • The safety valve is the important equipment used to protect the pressure vessel and pressure facilities from overpressure by discharging the operation medium when the pressure of system is reaching the design pressure of the system. Some materials for a safety valve disk are studied in this paper. A studied safety valve has to resist sulfurous acid and nitric acid. etc. Furthermore teflon which is a general material of the valve easily sticks to a disk and a sliding part of the valve by thermal expansion. Therefore both teflon and stainless-steel are used to improve these problems. The analysis of the thermal expansion is conducted with commercial FEM software to improve the problems. Boundary conditions were temperature and load in this study. From the analysis, the thermal expansion of by teflon/stainless steel-made valve is lower than that of teflon-made valve under high temperature. Thus, teflon/stainless steel-made valve is safe and no malfunction by thermal expansion.

  • PDF

SUS 304 발열선을 사용한 전기식 착화기의 열특성 분석 (Thermal Transient Analysis of Electric Initiator Used SUS 304 Bridgewire)

  • 윤기은;류병태;최홍석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.184-187
    • /
    • 2005
  • SUS 304 발열선(직경 2.3mil)과 $Zr-KClO_4$ 기폭화약을 사용한 전기식 착화기에 대한 열특성을 시험하고 Fitted Wire Model로 분석한 결과, 약 $300^{\circ}C$ 부근에서 기폭화약과 관련된 열특성 파라미터가 급격하게 변화되었다. 이 현상은 기폭화약에 사용된 $KClO_4$의 상변화로 인한 흡열과 발열선과 기폭화약 계면의 물리적 변화로 발생된 것으로 판단되며, 결과로 열특성 시험으로 구한 파라미터가 유용한 온도 범위를 제시하였다.

  • PDF

공동주택에서 비난방세대가 미치는 열적 영향 (Analysis for Thermal Effect by an Unheated Housing Unit in Apartment)

  • 이은주;구준모;홍희기
    • 설비공학논문집
    • /
    • 제28권1호
    • /
    • pp.42-47
    • /
    • 2016
  • Adjacent housing units suffer inevitable thermal losses if an unheated unit exists in an apartment building. Thermal loss of the units adjoining the unheated apartment can be neglected because the contact area is small and insulators are located in the walls. When insulators are not included in the slab between the upper and lower units, 70% of the heat supplied by an Ondol system may be used in the original unit, but 30% is transferred to the unit on the lower floor. Another 30% can be obtained from the ceiling if the upper floor housing unit is heated. This strong thermal connection is a characteristic of Ondol heating in apartment buildings. When there is an unheated unit, the lower floor unit uses 42.3% more heating energy if there is no insulation and 19.5% if a 35 mm insulator is used as in the current guidelines. Therefore, much thicker insulation should be applied to weaken the thermal connection.