• 제목/요약/키워드: thermal $T_g$

검색결과 482건 처리시간 0.027초

Synthesis of Novel Y-type Nonlinear Optical Polyesters with Enhanced Thermal Stability of Dipole Alignment

  • Jang, Han-Na;Lee, Ju-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권5호
    • /
    • pp.933-938
    • /
    • 2008
  • 2,4-Di-(2'-hydroxyethoxy)benzylidenemalononitrile (3) was prepared and polymerized with terephthaloyl chloride and adipoyl chloride to yield novel Y-type polyesters 4 and 5 containing dioxybenzylidenemalononitrile groups as NLO-chromophores, which constituted parts of the polymer backbone. The resulting polymers 4 and 5 are soluble in common organic solvents such as acetone and N,N-dimethylformamide. Polymers 4 and 5 showed thermal stability up to 300 ${^{\circ}C}$ in thermogravimetric analysis with glass-transition temperatures obtained from differential scanning calorimetry in the range 83-94 ${^{\circ}C}$. The second harmonic generation (SHG) coefficients ($d_{33}$) of poled polymer films at the 1064 nm fundamental wavelength were around $6.48\;{\times}\;10^{-9}$ esu. The dipole alignment exhibited high thermal stability even at 10 ${^{\circ}C}$ higher than $T_g$ and no significant SHG decay was observed below 105 ${^{\circ}C}$ partially due to the main-chain character of polymer structure, which is acceptable for NLO device applications.

접시형 태양열 집광 시스템을 이용한 열화학 사이클의 수소생산 (TWO-STEP THERMOCHEMICAL CYCLES FOR HYDROGEN PRODUCTION WITH DISH TYPE SOLAR THERMAL SYSTEM)

  • 권해성;오상준;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.169-176
    • /
    • 2011
  • The two-step water splitting thermochemical cycle is composed of the T-R (Thermal Reduction)and W-D (Water Decomposition)steps. The mechanism of this cycle is oxidation-reduction, which produces hydrogen. The reaction temperature necessary for this thermochemical cycle can be achieved by a dish-type solar thermal collector (Inha University, Korea). The purpose of this study is to validate a water splitting device in the field. The device is studied and fabricated by Kodama et al (2010, 2011). The validation results show that the foam device, when loaded with $NiFe_2O_4/m-ZrO_2$powder, was successfully achieved hydrogen production with 9 (10 with a Xe-light solar simulator, 2009, Kodama et al.) repeated cycles under field conditions. Two foam device used in this study were tested for validation before an experiment was performed. The lab scale ferrite-conversion rate was in the range of 24~76%. Two foam devices were designed to for structural stability in this study. In the results of the experiments, the hydrogen percentage of the weight of each foam device was 7.194 and $9.954{\mu}mol\;g^{-1}$ onaverage, and the conversion rates 4.49~29.97 and 2.55~58.83%, respectively.

  • PDF

Synthesis of Novel Y-type Nonlinear Optical Polyester with Enhanced Thermal Stability of Second Harmonic Generation for Electro-Optic Applications

  • Cho, You-Jin;Lee, Ju-Suk;Lee, Ju-Yeon
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권6호
    • /
    • pp.1509-1514
    • /
    • 2010
  • Methyl 3,4-di-(2'-hydroxyethoxy)benzylidenecyanoacetate (3) was prepared and condensed with terephthaloyl chloride to yield novel Y-type polyester (4) containing 3,4-dioxybenzylidenecyanoacetate groups as NLO-chromophores, which constituted parts of the polymer main chains. The resulting polymer 4 is soluble in common organic solvents such as acetone and N,N-dimethylformamide. Polymer 4 shows thermal stability up to $280^{\circ}C$ in thermogravimetric analysis with glass-transition temperature obtained from differential scanning calorimetry near $105^{\circ}C$. The second harmonic generation (SHG) coefficient ($d_{33}$) of poled polymer films at the 1064 nm fundamental wavelength is around 2.42 pm/V. The dipole alignment exhibits high thermal stability up to near $T_g$, and there is no SHG decay below $100^{\circ}C$ due to the partial main-chain character of polymer structure, which is acceptable for NLO device applications.

An Empirical Correlation for Critical Flow Rates of Subcooled Water Through Short Pipes with Small Diameters

  • Park, Choon-Kyung;Park, Jee-Won;Chung, Moon-Ki;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.35-44
    • /
    • 1997
  • Critical too-Phase flow rates of subcooled water through Short Pipes (L 140039n) with small diameters (D$\leq$7.15 min) have been experimentally investigated for wide ranges of subcooling (0~199$^{\circ}C$) and pressure (0.5~2.0 MPa). To examine the effects of various parameters (i.e., the location of flashing inception, the degree of subcooling, the stagnation temperature and pressure, and the pipe size) on the critical two-phase flow rates of subcooled water through short pipes with small diameters, a total of 135 runs were made for various combinations of test parameters using four different L/D test sections. Experimental results that show effect of various parameters on subcooled critical two phase flow rates are presented in the form of graphs such as the dimensionless mass flux ( $G^{*}$) versus the dimensionless subcooling ( $T_{sub}$$^{*}$) curve. An empirical correlation expressed in terms of a dimensionless subcooling is also obtained for subcooled two-phase flow rates through present test sections. Comparisons between the mass fluxes calculated by present correlation and a total of 755 selected experimental data points of 9 different investigators show that the agreement is fairly good except for very low subcooling data obtained from small L/D (less than 10) orifices.s.s.s.

  • PDF

지하철 터널내 열환경 예측 프로그램 개발에 관한 연구 (A study on the development of thermal environment prediction program in tunnel of the subway)

  • 김종렬;김동규;금종수;최광환;정효민;박준택
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.504-516
    • /
    • 1997
  • Recently scientists and engineers are developing a system to get waste heat of low-temperature level with advanced heat pump, which have not been used up to now. As the reason, it is necessary to examine capability of using waste heat which is raised up in the tunnel of subway out of widely distributed low-temperature waste heat in large cities. Therefore we surveyed thermal environment of the tunnel of subway in $S\check{o}my\check{o}n$, downtown of Pusan, from November 1995 to December 1996 and developed a program to predict the thermal environment of subway on the basis of experimental data and the geometries of tunnels. This paper has proved availability of waste heat of subway when the measured results obtained in subway in the winter time and the simulated results of thermal environment prediction program are compared, as well as has reported results of estimating reliability of the simulation program. As the result, the charateristics of thermal environment in the tunnel of subway in $S\check{o}my\check{o}n$ station in the winter time are to be followed; 1) temperature in the tunnel is about $10^{\circ}C$ higher than outside air temperature, 2) temperature change in the tunnel is less than that in the platform so that we may obtain stable heat source, 3) and when the measured results obtained in subway in the winter time and the simulated results of thermal environment prodiction program is compared, both results show similar tendency. Therefore, we confirm estimating reliability of the simulation program.

  • PDF

연속주조용 Porous Nozzle의 기공율이 내구성에 미치는 영향 (Effects of Porosity on Durability in a Porous Nozzle for Continuous Casting)

  • 윤상현;조문규;정두화;이희수
    • 대한금속재료학회지
    • /
    • 제48권7호
    • /
    • pp.625-629
    • /
    • 2010
  • This study investigates the effects of porosity on the thermal stability and the thermal shock resistance of a porous nozzle used for blowing an inert gas. The samples of $Al_2O_3-SiO_2-ZrO_2$ system, which had the apparent porosity of 16~30% and bulk density of $2.6{\sim}3.2g/cm^3$, were prepared by adding different graphite contents (5, 10, 20 wt%) as a pore-forming agent. The thermal shock test was conducted at ${\Delta}T=500$, 1000, and $1400^{\circ}C$ also and the thermal stability was also carried out at 1550, 1600, and $1650^{\circ}C$ for 5 hrs. The specimen contained 10 wt% graphite had uniform pore size distribution, whereas the specimen with 20 wt% graphite showed non-uniform pore size distribution. As a result of thermal shock test, the specimen containing 10 wt% graphite appears to have higher mechanical strength than the other specimens (5, 20 wt% graphite). Both the 5 wt% and 20 wt% graphite specimens developed a non-uniform pore size distribution and cracks that were generated by intensive thermal stress.

국산 Fly Ash의 특성 및 단열재로의 이용에 관한 연구 (A Study on Properties of Domestic Fly Ash and Utilization as an Insulation material)

  • 박금철;임태영
    • 한국세라믹학회지
    • /
    • 제20권2호
    • /
    • pp.135-146
    • /
    • 1983
  • This study is to investigate the properties of domestic fly ash for utilization as data in regard to fly ash which is by-product of domestic coal powder plants and the possibility of utilization as insulation material of domestic fly ash. Composition refractoriness size distribution density contents of hollow particles and crystalline phase were examined as the properties of domestic fly ash. As to the fired test pieces of fly ash by itself that varied contents of hollow particles with four kinds and of the fly ash-clay-saw dust system linear shrinkage bulk density app. porosity compressive strength thermal conductivity and structures were investigated for the possibility of utilization as an insulation material. The results are as follows : 1. The properties of the fly ash I) The constituent particle of the fly ash is spherical and it contains not a few hollow particles (floats by water 0.30-0.50 floats by $ZnCl_2$ aq.(SpG=1.71) 6.97-16.72%). ii) The chemical compositions of fly ash are $SiO_243.9-54.1%$ , $Al_2O_321.0-30.7%$ Ig loss is 7.4-24.1% and the principal of Ig loss is unburned carbon. iii) Fly ash was not suitable to use for mortar and concrete mixture because Ig. loss value is higher than 5% 2. Utilization as insulation material I) The test pieces of original fly ash floats by water floats by ZnCl2 aq(SpG=1.71) p, p t by ZnCl2 aq.(SpG=1.71) that were fired at 110$0^{\circ}C$ represented 0.11-0.18 kcal/mh$^{\circ}$ C as thermal conductivity value. ii) The test pieces which (76.5-85.5) wt% fly ash-(8.5, 9.5) wt% clay-(5.0-15.0) wt% saw dust system(68.0-72.0) wt% fly ash -(17.0-18.0)wt% clay-(10.0-15.0) wt% saw dust system and 59.5 wt% fly ash-25.5 wt% clay-15.0wt% saw dust system were fired at 110$0^{\circ}C$ the thermal conductivity was less than 0.1Kcal/mh$^{\circ}$ C. iii) In view of thermal conductivity and economic aspect insulation materials which added saw dust as blowing agent and clay as inorganic binder are better than that of fly ash as it is or separated hollow fly ash particles. iv) When the saw dust contents increased in the (59.5-90.0) wt% saw dust system and when amount of clay de-creased and firing temperature decreased under the condition of equal addition of saw dust app. porosity increased but bulk density compressive strength and thermal conductivity decreased.

  • PDF

세그먼트된 폴리우레탄 블렌드의 열이력에 따른 열적 성질과 분자량 변화 (Thermal Properties and Molecular Weight Variations due to Thermal History in Segmented Polyurethane Copolymer Blends)

  • 차윤종;박대운;김학림;이한섭;마석일;최순자
    • 공업화학
    • /
    • 제10권1호
    • /
    • pp.35-40
    • /
    • 1999
  • Hard segment 함량이 35%와 53%로 서로 다른 두 개의 열가소성 폴리우레탄 시료 (각각 TPU-35와 TPU-35)와 이들을 70/30, 50/50, 30/70 wt%로 용융 블렌딩한 조성들이 annealing 온도와 시간에 따라 변화할 수 있는 유리전이온도와 용융피이크, 분자량 및 분자량 분포도의 변화를 관찰하였다. TPU의 $T_g$는 hard segment 함량이 많을수록 높은 값을 보였으며 annealing 온도와 시간에 따라 hard microdomain 구조의 미약한 관계에 의한 용융피이크의 크기와 온도 등이 변하였다. 이는 annealing에 의한 열이 long-range 혹은 short-range segmental motion의 거동, 비결정 microphase 구조의 order-disorder 전이, domain의 크기 및 결정구조의 질서도 등 여러 가지 복합적인 영향을 끼친 결과로 사료된다. 미세 결정의 용융 결과로 나타나는 $T_3$단일 피이크만이 존재하는 annealing 온도는 TPU-35, TPU-44와 TPU-53에 대해 각각 130, 170 및 $180^{\circ}C$이었다. Annealing 온도와 시간에 따른 분자량 및 분자량 분포도 변화 측정에서 TPU-35는 $135^{\circ}C$에서, TPU-44(TPU-35/TPU-53=50/50 블랜드)는 $170^{\circ}C$, 그리고 TPU-53은 $180^{\circ}C$에서 수평균 및 중량평균 분자량의 증가와 더불어 polydispersity(PI)는 감소를 보였다. 이 변화는 같은 조건의 annealing 온도에 따른 용융피이크 변화에서 $T_3$단일 피이크만 남게 되는 annealing온도와 일관성을 보이고 있는데, 이는 이들 시료가 특정한 annealing 온도에서 chain dissociation과 recombination이 동시에 일어나므로써 빚어진 결과로 추측된다.

  • PDF

위성방송 수신용 소형 반사면 안테나의 절단 크기에 따른 성능지수의 분석 (An Analysis of the Figure of Merit depending on the cut-off size of a Small Reflector for Satellite Broadcast Receiving Antenna)

  • 임계재
    • 한국정보전자통신기술학회논문지
    • /
    • 제6권3호
    • /
    • pp.152-155
    • /
    • 2013
  • 본 논문은 위성방송 수신용 소형 파라볼라 안테나의 높이를 보다 낮추기 위하여 반사면의 상하 부분을 부분적으로 절단하였을 때 나타나는 spill-over 의 증가로 인한 성능지수의 저하를 분석하였다. 또한 안테나를 고도각 0도부터 60도까지 트래킹하는 경우에 측엽과 후엽이 받는 대지면 열잡음의 증가로 인한 잡음온도의 영향을 고려하고, LNA 의 잡음지수로 인한 총 잡음온도의 증가 영향을 고려하여 성능지수 값을 시뮬레이션하여 그 결과를 분석하였다. 분석 결과, 원형 파라볼라의 반사면 상하부분을 35% 절단하였을 때, 잡음온도는 약 15K 정도 증가하였으며, G/T 비는 2.5dB 정도 저하하였다.

에폭시 복합체의 TSC특성파 구조변화사이의 상관성 연구 (A Study on The Relationship between TSC Properties and Structural Changes of Epoxy Composites Materials)

  • 왕종배;박준범;박경원;신철기;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 추계학술대회 논문집
    • /
    • pp.75-79
    • /
    • 1993
  • The Thermally Stimulated Current(TSC) method has been allied to study the influence of the structural change and interface on the electrical properties of epoxy composites. Three DGBA- MeTHPA matrix model samples mixed different ratios arts silica(SiO$_2$) filled sample and silaln treating-filled sample have been studied. Above room temperature, the relaxation mode ${\alpha}$ peak associated with T$\_$g/ has been located at 110$^{\circ}C$. Below glass transition temperature(T$\_$g/), three relaxation modes are observed in all samples : a ${\beta}$ mode situated at 10$^{\circ}C$, a ${\gamma}$ mode located at -40$^{\circ}C$ and a $\delta$mode appeared in -120$^{\circ}C$, which may be due to segmental motion, side chains, substitution and terminal groups. The analysis of its fine structure indicates that constitution of elementary processes is characterized by the activation energy and relaxation time. Also the change of the molecular structure and their thermal motion are compared with the relaxation mode and conduction mechanism in TSC spectra through the dielectric properties and FTIR measurements.

  • PDF