• Title/Summary/Keyword: the w-operation

Search Result 2,465, Processing Time 0.215 seconds

Analysis of Operating Mode Characteristics of Dynamic UPS (다이나믹 UPS의 모드별 동작특성 분석)

  • Lee K.S.;Kim J.W.;Byeon W.Y.;Nho E.C.;Kim I.D.;Chun T.W.;Kim H.G.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1257-1259
    • /
    • 2004
  • This paper deals with the operation of a flywheel energy storage UPS. The operating principle of the UPS is analysed in each mode including charging, voltage compensation, discharging, and voltage unbalance compensation. The usefulness of the operation is proved through simulations.

  • PDF

940-nm 350-mW Transverse Single-mode Laser Diode with AlGaAs/InGaAs GRIN-SCH and Asymmetric Structure

  • Kwak, Jeonggeun;Park, Jongkeun;Park, Jeonghyun;Baek, Kijong;Choi, Ansik;Kim, Taekyung
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.583-589
    • /
    • 2019
  • We report experimental results on 940-nm 350-mW AlGaAs/InGaAs transverse single-mode laser diodes (LDs) adopting graded-index separate confinement heterostructures (GRIN-SCH) and p,n-clad asymmetric structures, with improved temperature and small-divergence beam characteristics under high-output-power operation, for a three-dimensional (3D) motion-recognition sensor. The GRIN-SCH design provides good carrier confinement and prevents current leakage by adding a grading layer between cladding and waveguide layers. The asymmetric design, which differs in refractive-index distribution of p-n cladding layers, reduces the divergence angle at high-power operation and widens the transverse mode distribution to decrease the power density around emission facets. At an optical power of 350 mW under continuous-wave (CW) operation, Gaussian narrow far-field patterns (FFP) are measured with the full width at half maximum vertical divergence angle to be 18 degrees. A threshold current (Ith) of 65 mA, slope efficiency (SE) of 0.98 mW/mA, and operating current (Iop) of 400 mA are obtained at room temperature. Also, we could achieve catastrophic optical damage (COD) of 850 mW and long-term reliability of 60℃ with a TO-56 package.

Development of 1 kW class PEFC co-generation system for buildings (1kW 급 건물용 연료전지 시스템 개발 현황)

  • Jun, Hee-Kwon;Hwang, Jung-Tae;Lee, Kap-Sik;Choi, Choeng-Hoon;Lee, Dong-Hwal;Bae, Joon-Kang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.328-330
    • /
    • 2009
  • 1 kW class Polymer Electrolyte Fuel Cell(PEFC) co-generation systems have been developed from 2001 and evaluated for improvement of efficiency, durability and reliability of the system. This paper introduce new version system including with excellent reliability, durability and user friendly applications. Its electrical and overall efficiency showed 35 % and 80 %, respectively, and noise level of the system was less than 45 dB. In addition, this system have various functions such as load change, $N_2$ less purge, low emission and low temperature operation ($-15^{\circ}C$) through development of operation logic. This system was designed for convenient installation in indoor and outdoor due to the compactness of size and the separation of electrical and heat recovery units, which means a user can select the size of heat recovery unit.

  • PDF

The Comparison of Vibration and Power according to Operation Method of 100W IPM Type Motor

  • Lee, Gyeong-Deuk;Jo, Eul-Gyu;Kim, Gyu-Tak
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.383-388
    • /
    • 2014
  • In This paper, the output characteristics and vibrations were compared and analyzed according to operation method in 100W class. The voltage source is applied only two phase in BLDC drive system therefore commutation torque ripple and imbalance of RMF occurred. Due to this efficiency was significantly degraded because mechanical loss is increased, besides the vibration and noise were greatly generated. The vibration and output characteristics were compared and analyzed according to three phase and BLDC drive system.

Study on anode in SOFC (SOFC 연료극의 전극특성)

  • Eom, S.W.;Kim, G.Y.;Moon, S.I.;Lim, H.C.;Lee, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.404-405
    • /
    • 1995
  • Solid Oxide Fuel Cell has advantage of high utility because of having high operation temperature. In case of anode, Ni and YSZ being widly used as anode start materials. But Ni can be sintered during operation because that its operation temperature is very high, so it cause to lower the cell performance. It is very important to control the ratio of Ni to YSZ. In this paper, we studed on characterization of anode by controlling the Ni-YSZ contents.

  • PDF

Demonstration analysis of residential 3kW PV System (주택보급형 3kW PV시스템 실증연구)

  • Park, J.M.;Moon, Y.A.;Kim, H.S.;Lim, B.O.;Baek, H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.734-736
    • /
    • 2005
  • This paper presents experimental operation with utility invertactive 3kW photovoltaic generation system. And that describe configuration of utility interactive photovoltaic system which power supply for Demonstration experiment. The status of photovoltaic generation system comp-onents and interconnection and safety equipment will be summarized. This paper discusses property operation state which system endure division of power for demonstration experiment.

  • PDF

Development of LVAD Control System using Micro Controller (마이크로 컨트롤러를 이용한 전기유압식 좌심실보조기 제어시스템의 개발)

  • Lee, S.W.;Chung, C.I.;Choi, J.W.;Kim, H.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.127-129
    • /
    • 1992
  • In this paper, we describe about control system for eletro-hydraulic LVAD(Left Ventricular Assist Device) and control algorithm for two operation mode. One is asynchronous operation mode and the other is synchronous operation mode synchronized with natural heart's R pulse. We also present implementation method of software PI algorithm for velocity control of motor used in LVAD system and its response.

  • PDF

Development and Performance Test of SOFC Co-generation System for RPG (SOFC를 이용한 가정용 열병합 발전시스템 개발 및 성능시험)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Choi, Ho-Yun;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.361-364
    • /
    • 2009
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 cells with $10{\times}10cm^2$ area and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water. Recently KEPRI developed stacks using $15{\times}15cm^2$ cells and tested them. KEPRI will develop a 5 kW class CHP system using $15{\times}15cm^2$ stacks by 2010.

  • PDF

120W SSPA System Design for S-Band Uplink Application

  • Ahn Sang-il;Park Dong-Chul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.460-463
    • /
    • 2004
  • There is a trend to replace TWTA of SSPA in S-Band uplink application for satellite operation. KARI developed l20W full S-Band SSPA system in early 2004. This paper covers SSPA system design and its test results. Through tests, nominal gain of 57dB, gain stability of +/-1dB over frequency, and gain stability of +/-0.5dB over temperature were shown. IMD value of -16.5dBc, -19dBc were revealed in PI and P3 output operations. With meeting specifications, l20W SSPA is expected to be used in operational S-Band uplink application.

  • PDF

A NOTE ON ZERO DIVISORS IN w-NOETHERIAN-LIKE RINGS

  • Kim, Hwankoo;Kwon, Tae In;Rhee, Min Surp
    • Bulletin of the Korean Mathematical Society
    • /
    • v.51 no.6
    • /
    • pp.1851-1861
    • /
    • 2014
  • We introduce the concept of w-zero-divisor (w-ZD) rings and study its related rings. In particular it is shown that an integral domain R is an SM domain if and only if R is a w-locally Noetherian w-ZD ring and that a commutative ring R is w-Noetherian if and only if the polynomial ring in one indeterminate R[X] is a w-ZD ring. Finally we characterize universally zero divisor rings in terms of w-ZD modules.