• Title/Summary/Keyword: the use of technology

Search Result 24,525, Processing Time 0.064 seconds

A Study on the Impact of Artificial Intelligence on Decision Making : Focusing on Human-AI Collaboration and Decision-Maker's Personality Trait (인공지능이 의사결정에 미치는 영향에 관한 연구 : 인간과 인공지능의 협업 및 의사결정자의 성격 특성을 중심으로)

  • Lee, JeongSeon;Suh, Bomil;Kwon, YoungOk
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.3
    • /
    • pp.231-252
    • /
    • 2021
  • Artificial intelligence (AI) is a key technology that will change the future the most. It affects the industry as a whole and daily life in various ways. As data availability increases, artificial intelligence finds an optimal solution and infers/predicts through self-learning. Research and investment related to automation that discovers and solves problems on its own are ongoing continuously. Automation of artificial intelligence has benefits such as cost reduction, minimization of human intervention and the difference of human capability. However, there are side effects, such as limiting the artificial intelligence's autonomy and erroneous results due to algorithmic bias. In the labor market, it raises the fear of job replacement. Prior studies on the utilization of artificial intelligence have shown that individuals do not necessarily use the information (or advice) it provides. Algorithm error is more sensitive than human error; so, people avoid algorithms after seeing errors, which is called "algorithm aversion." Recently, artificial intelligence has begun to be understood from the perspective of the augmentation of human intelligence. We have started to be interested in Human-AI collaboration rather than AI alone without human. A study of 1500 companies in various industries found that human-AI collaboration outperformed AI alone. In the medicine area, pathologist-deep learning collaboration dropped the pathologist cancer diagnosis error rate by 85%. Leading AI companies, such as IBM and Microsoft, are starting to adopt the direction of AI as augmented intelligence. Human-AI collaboration is emphasized in the decision-making process, because artificial intelligence is superior in analysis ability based on information. Intuition is a unique human capability so that human-AI collaboration can make optimal decisions. In an environment where change is getting faster and uncertainty increases, the need for artificial intelligence in decision-making will increase. In addition, active discussions are expected on approaches that utilize artificial intelligence for rational decision-making. This study investigates the impact of artificial intelligence on decision-making focuses on human-AI collaboration and the interaction between the decision maker personal traits and advisor type. The advisors were classified into three types: human, artificial intelligence, and human-AI collaboration. We investigated perceived usefulness of advice and the utilization of advice in decision making and whether the decision-maker's personal traits are influencing factors. Three hundred and eleven adult male and female experimenters conducted a task that predicts the age of faces in photos and the results showed that the advisor type does not directly affect the utilization of advice. The decision-maker utilizes it only when they believed advice can improve prediction performance. In the case of human-AI collaboration, decision-makers higher evaluated the perceived usefulness of advice, regardless of the decision maker's personal traits and the advice was more actively utilized. If the type of advisor was artificial intelligence alone, decision-makers who scored high in conscientiousness, high in extroversion, or low in neuroticism, high evaluated the perceived usefulness of the advice so they utilized advice actively. This study has academic significance in that it focuses on human-AI collaboration that the recent growing interest in artificial intelligence roles. It has expanded the relevant research area by considering the role of artificial intelligence as an advisor of decision-making and judgment research, and in aspects of practical significance, suggested views that companies should consider in order to enhance AI capability. To improve the effectiveness of AI-based systems, companies not only must introduce high-performance systems, but also need employees who properly understand digital information presented by AI, and can add non-digital information to make decisions. Moreover, to increase utilization in AI-based systems, task-oriented competencies, such as analytical skills and information technology capabilities, are important. in addition, it is expected that greater performance will be achieved if employee's personal traits are considered.

Analysis of Quantitative Indices in Tl-201 Myocardial Perfusion SPECT: Comparison of 4DM, QPS, and ECT Program (Tl-201 심근 관류 SPECT에서 4DM, QPS, ECT 프로그램의 정량적 지표 비교 분석)

  • Lee, Dong-Hun;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.67-75
    • /
    • 2009
  • Purpose: As to the analytical method of data, the various programs in which it is used for the quantitative rating of the Tl-201 myocardial perfusion SPECT are reported that there is a difference. Therefore, the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made against data of the same patient. Using quantitative index that able to represent myocardial perfusion defect level, we aimed to determine correlation among three myocardial perfusion analysis programs 4DM (4DMSPECT), QPS (Quantitative Perfusion SPECT), ECT (Emory Cardiac Toolbox) that be used generally in most departments of Nuclear Medicine. Materials and Methods: We analyzed the 145 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Mediacal Center from December 1th 2008 to February 14th 2008. We sorted as normal group and abnormal group. Normal group consist of 80 patients (Male/Female=38/42, age:$65.1{\pm}9.9$) who have low possibility of cardiovascular disease. And abnormal group consist of 65 patients (Male/Female=45/20, age:$63.0{\pm}8.7$) who were diagnosed cardiovascular disease with reversible perfusion defect or fixed perfusion defect through myocardial perfusion SPECT results. Using the 4DM, QPS, and ECT programs, the total defect extent (TDE) such as LAD, LCX, RCA and the summed stress score (SSS) have been analysed for their correlations and statistical comparison with the paried t-test for the quantitative indices analysed from each group. Results: The correlation of 4DM:QPS, QPS:ECT, ECT:4DM each group result from 145 patients is 0.84, 0.86, 0.82 at SSS, 0.87, 0.84, 0.87 at TDE, and both index showed good correlation. In paired t-test and Bland-Altman analysis results showed no statistically significant difference in the comparison of QPS:ECT at the mean SSS and TDE, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index. The correlation of 4DM:QPS, QPS:ECT, ECT:4DM program results from abnormal group (65 patients) is 0.72, 0.72, 0.70 at SSS and 0.77, 0.70, 0.77 at TDE and TDE and SSS has a good correlation. In abnormal group, paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.89) and TDE (p=0.23) comparison, 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). In normal group (80 patients), paired t-test and Bland-Altman analysis results showed no statistically significant difference at QPS:ECT SSS (p=0.95) and TDE (p=0.73) comparison. And 4DM:QPS, ECT:4DM comparative analysis results showed statistically significant difference at SSS and TDE index (p<0.01). Conclusions: The perfusion defect of the Tl-201 myocardial perfusion SPECT was analyzed in not only the patient in whom it has the cardiovascular disease but also the patient in whom the possibility of the cardiovascular disease is few. In the comparison of the all group research, the mean of the TDE and SSS, 4DM was lower than QPS and ECT progrms. Each program showed good correlation and the results showed statistically significant difference. However, in this way, it is determined to be compatible about the analysis value in which the large-scale side between the programs uses each program a difference in a clinical in the Bland-Altman analyzed result in spite of the good correlation and cannot use. but, this analyzed result will be able to be usefully used as the reference material for the clinical read and is expected.

  • PDF

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control (핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용)

  • Jung, Heung-Soo;Bae, Jin-Soo;Shin, Yong-Hwan;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.115-118
    • /
    • 2012
  • Purpose: The Levey-Jennings chart controlled measurement values that deviated from the tolerance value (mean ${\pm}2SD$ or ${\pm}3SD$). On the other hand, the upgraded Westgard Multi-Rules are actively recommended as a more efficient, specialized form of hospital certification in relation to Internal Quality Control. To apply Westgard Multi-Rules in quality control, credible quality control substance and target value are required. However, as physical examinations commonly use quality control substances provided within the test kit, there are many difficulties presented in the calculation of target value in relation to frequent changes in concentration value and insufficient credibility of quality control substance. This study attempts to improve the professionalism and credibility of quality control by applying Westgard Multi-Rules and calculating credible target value by using a commercialized quality control substance. Materials and Methods : This study used Immunoassay Plus Control Level 1, 2, 3 of Company B as the quality control substance of Total T3, which is the thyroid test implemented at the relevant hospital. Target value was established as the mean value of 295 cases collected for 1 month, excluding values that deviated from ${\pm}2SD$. The hospital quality control calculation program was used to enter target value. 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T of Westgard Multi-Rules were applied in the Total T3 experiment, which was conducted 194 times for 20 days in August. Based on the applied rules, this study classified data into random error and systemic error for analysis. Results: Quality control substances 1, 2, and 3 were each established as 84.2 ng/$dl$, 156.7 ng/$dl$, 242.4 ng/$dl$ for target values of Total T3, with the standard deviation established as 11.22 ng/$dl$, 14.52 ng/$dl$, 14.52 ng/$dl$ respectively. According to error type analysis achieved after applying Westgard Multi-Rules based on established target values, the following results were obtained for Random error, 12s was analyzed 48 times, 13s was analyzed 13 times, R4s was analyzed 6 times, for Systemic error, 22s was analyzed 10 times, 41s was analyzed 11 times, 2 of 32s was analyzed 17 times, $10\bar{x}$ was analyzed 10 times, and 7T was not applied. For uncontrollable Random error types, the entire experimental process was rechecked and greater emphasis was placed on re-testing. For controllable Systemic error types, this study searched the cause of error, recorded the relevant cause in the action form and reported the information to the Internal Quality Control committee if necessary. Conclusions : This study applied Westgard Multi-Rules by using commercialized substance as quality control substance and establishing target values. In result, precise analysis of Random error and Systemic error was achieved through the analysis of 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T rules. Furthermore, ideal quality control was achieved through analysis conducted on all data presented within the range of ${\pm}3SD$. In this regard, it can be said that the quality control method formed based on the systematic application of Westgard Multi-Rules is more effective than the Levey-Jennings chart and can maximize error detection.

  • PDF

Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function (의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.3-12
    • /
    • 2011
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: From January 1, 2010 December 31, 2010, medical practitioners working in the radiation is classified as a regular personal radiation dosimetry, and subsequently one year 540 people managed investigation department to target workers, dose sectional area, working period, identify the job function-related tasks for a deep dose, respectively, the annual average radiation dose were analyzed. Frequency analysis methods include ANOVA was performed. Results: Medical radiation workers in the department an annual radiation dose of Nuclear and 4.57 mSv a was highest, dose zone-specific distribution of nuclear medicine and in the 5.01~19.05 mSv in the high dose area distribution showed departmental radiation four of the annual radiation dose of Nuclear and 7.14 mSv showed the highest radiation dose. More work an average annual radiation dose according to the job function related to the synthesis of Cyclotron to 17.47 mSv work showed the highest radiation dose, Gamma camera Cinema Room 7.24 mSv, PET/CT Cinema Room service is 7.60 mSv, 2.04 mSv in order of intervention high, were analyzed. Working period, according to domain-specific average annual dose of radiation dose from 10 to 14 in oral and maxillofacial radiology practitioners as high as 1.01~3.00 mSv average dose showed the Department of Radiology, 1-4 years, 5-9 years, respectively, 1.01 workers~8.00 mSv in the range of the most high-dose region showed the distribution, nuclear medicine, and the 1-4 years, 5-9 years 3.01~19.05 mSv, respectively, workers of the highest dose showed the distribution of the area in the range of 10 to 14 years, Workers at 15-19 3.01~15.00 mSv, respectively in the range of the high-dose region were distributed. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Approach to the Extraction Method on Minerals of Ginseng Extract (추출조건(抽出條件)에 따른 인삼(人蔘)엑기스의 무기성분정량(無機成分定量)에 관(關)한 연구(硏究))

  • Cho, Han-Ok;Lee, Joong-Hwa;Cho, Sung-Hwan;Choi, Young-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.95-106
    • /
    • 1976
  • In order to investigate chemical components and mineral of ginseng cultivated in Korea and to establish an appropriate extraction method, the present work was carried out with Raw ginseng(SC), White ginseng(SB) and Ginseng tail(SA). The results determined could be summarized as follows : 1. Among the proximate components, moisture content of SC, SB and SA were 66.37%, 12.61% and 12.20% respectively. The content of crude ash in SA was the highest value of three kinds of ginseng root: SA 6.04%, SB 3.52% and SC 1.56%. The crude protein of Dried ginseng root(SA and SB) was about 12-14%, which was more than two times compared with that of SC(6.30%) The content of pure protein seemed to be in similar tendency with that of crude protein in three kinds of ginseng root: 2.26% in SC, 5.94% in SB and 5.76% in SA. There was no significant difference in the content of fat among the kinds of ginseng root. $(1.1{\sim}2.5%)$ 2. The highest Ginseng extract was obtained by use of Continuous extractor which is a modified Soxhlet apparatus for 60 hours extraction with 60-80% ethanol. 3. Ginseng and the above-mentioned ginseng extract (Ginseng tail extract: SAE, White Ginseng extract : SBE, Raw Ginseng extract: SCE) were analyzed by volumetric method for the determination of Chlorine and Calcium, by colorimetric method for that of Iron and Phosphorus, by Atomic Absorption Spectrophotometer for that of Zinc, Copper and Manganese. The results were as follows : 1. The content of phosphorus in SA, SB and SC were 1.818%, 1.362%, 0.713% respectively and phosphorus content in three kinds of extract were in low level (SAE: 0.03%, SBE: 0.063%, SCE: 0.036%) 2. In the Calcium content, SA, SB and SC were 0.147%, 0.238%, 0.126% and the Calcium contents of Ginseng extracts were 0.023%, 0.011% and 0.016%. The extraction ratio of Calcium from SA was the highest value (15.6%), while that in the case of SB was 4.6%. 3. The Chlorine content of SA was 0.11%, this was slightly higher than others(SB: 0.07%, SC: 0.09%) and extraction ratio of SA and SB were 36.4%, 67.1% while that of SC was 84.4%. 4. The Iron content of SA, SB and SC were 125ppm, 32.5ppm and 20ppm but extraction ratio was extremely low (SAE: 1.33%, SBE: 0.83%, SCE: 1.08%), 5. The Manganese content of SA, SB and SC were 62.5ppm, 25.0ppm and 5.0ppm respectively but the Manganese content of extract could not determined, Copper content of SA, SB and SC were 15.0ppm, 20.0ppm and those of extract were 7.5ppm, 6.5ppm, 4.5ppm while those of extraction ratio were 50%, 32.5% and 90% respectively, Zinc was abundant in Ginseng compared with other herbs, (SA: 45.5ppm, SB: 27.5ppm and SC: 5.5ppm) and the extracted amount were 4.5ppm, 1.25ppm 1.50ppm respectively.

  • PDF

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

Stock Identification of Todarodes pacificus in Northwest Pacific (북서태평양에 서식하는 살오징어(Todarodes pacificus) 계군 분석에 대한 고찰)

  • Kim, Jeong-Yun;Moon, Chang-Ho;Yoon, Moon-Geun;Kang, Chang-Keun;Kim, Kyung-Ryul;Na, Taehee;Choy, Eun Jung;Lee, Chung Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.4
    • /
    • pp.292-302
    • /
    • 2012
  • This paper reviews comparison analysis of current and latest application for stock identification methods of Todarodes pacificus, and the pros and cons of each method and consideration of how to compensate for each other. Todarodes pacificus which migrates wide areas in western North Pacific is important fishery resource ecologically and commercially. Todarodes pacificus is also considered as 'biological indicator' of ocean environmental changes. And changes in its short and long term catch and distribution area occur along with environmental changes. For example, while the catch of pollack, a cold water fish, has dramatically decreased until today after the climate regime shift in 1987/1988, the catch of Todarodes pacificus has been dramatically increased. Regarding the decrease in pollack catch, overfishing and climate changes were considered as the main causes, but there has been no definite reason until today. One of the reasons why there is no definite answer is related with no proper analysis about ecological and environmental aspects based on stock identification. Subpopulation is a group sharing the same gene pool through sexual reproduction process within limited boundaries having similar ecological characteristics. Each individual with same stock might be affected by different environment in temporal and spatial during the process of spawning, recruitment and then reproduction. Thereby, accurate stock analysis about the species can play an efficient alternative to comply with effective resource management and rapid changes. Four main stock analysis were applied to Todarodes pacificus: Morphologic Method, Ecological Method, Tagging Method, Genetic Method. Ecological method is studies for analysis of differences in spawning grounds by analysing the individual ecological change, distribution, migration status, parasitic state of parasite, kinds of parasite and parasite infection rate etc. Currently the method has been studying lively can identify the group in the similar environment. However It is difficult to know to identify the same genetic group in each other. Tagging Method is direct method. It can analyse cohort's migration, distribution and location of spawning, but it is very difficult to recapture tagged squids and hard to tag juveniles. Genetic method, which is for useful fishery resource stock analysis has provided the basic information regarding resource management study. Genetic method for stock analysis is determined according to markers' sensitivity and need to select high multiform of genetic markers. For stock identification, isozyme multiform has been used for genetic markers. Recently there is increase in use of makers with high range variability among DNA sequencing like mitochondria, microsatellite. Even the current morphologic method, tagging method and ecological method played important rolls through finding Todarodes pacificus' life cycle, migration route and changes in spawning grounds, it is still difficult to analyze the stock of Todarodes pacificus as those are distributed in difference seas. Lately, by taking advantages of each stock analysis method, more complicated method is being applied. If based on such analysis and genetic method for improvement are played, there will be much advance in management system for the resource fluctuation of Todarodes pacificus.