• Title/Summary/Keyword: the standard of reference

Search Result 2,150, Processing Time 0.03 seconds

Normal antistreptolysin O titers of children by age group in the Gyeonggi-Incheon region (경인지역에서 조사한 소아의 연령별 antistreptolysin O 역가)

  • Lee, Jihun;Kim, Yoo Jung;Bin, Joong Hyun;Hwang, Ja Young;Hahn, Seong Hoon;Kim, So Young;Kim, Hyun Hee;Lee, Wonbae
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.965-969
    • /
    • 2007
  • Purpose : Measurement of antistreptolysin O (ASO) is often necessary to confirm a clinical diagnosis of recent streptococcal infection, especially in patients suspected of rheumatic fever and acute glomerulonephritis. Standard normal ranges for ASO should be established locally for each age group. We analyzed ASO to determine the upper limit of normal (ULN) ASO in children in the Gyeonggi-Incheon area. Methods : ASO in normal individual concentrations were measured quantitatively by nephelometry on sera from 753 children (Male : 381, Female : 372). ULN were determined by separating the upper 20% from the lower 80% of the group (80 percentile). Results : The mean ASO concentration calculated in a total cases was $149.9{\pm}7.2IU/mL$. The ASO concentration in neonates was $83.4{\pm}10.7IU/mL$, and lowest in the 1 year of age group, $26.7{\pm}6.6IU/mL$, and increased to $318.0{\pm}33.2IU/mL$ gradually in the 9 years of age group. Thereafter, ASO concentration decreased. The ULN for neonates was 122 IU/mL, for 0-3 years, 40 IU/mL; for 4-6 years, 113 IU/ mL; for 7-9 years, 489 IU/mL; for 10-19 years, 433 IU/mL; for 20-29 years, 122 IU/mL. Conclusion : The age-specific ULN for children in the Gyeonggi-Incheon area were determined. The distribution of ASO concentration according to age groups was different from previous reports. These results should be of clinical value to physicians to interprete the ASO results of their patients.

A Study on the Structural Reinforcement of the Modified Caisson Floating Dock (개조된 케이슨 플로팅 도크의 구조 보강에 대한 연구)

  • Kim, Hong-Jo;Seo, Kwang-Cheol;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.172-178
    • /
    • 2021
  • In the ship repair market, interest in maintenance and repair is steadily increasing due to the reinforcement of prevention of environmental pollution caused by ships and the reinforcement of safety standards for ship structures. By reflecting this effect, the number of requests for repairs by foreign shipping companies increases to repair shipbuilders in the Southwest Sea. However, because most of the repair shipbuilders in the southwestern area are small and medium-sized companies, it is difficult to lead to the integrated synergy effect of the repair shipbuilding companies. Moreover, the infrastructure is not integrated; hence, using the infrastructure jointly is a challenge, which acts as an obstacle to the activation of the repair shipbuilding industry. Floating docks are indispensable to operating the repair shipbuilding business; in addition, most of them are operated through renovation/repair after importing aging caisson docks from overseas. However, their service life is more than 30 years; additionally, there is no structure inspection standard. Therefore, it is vulnerable to the safety field. In this study, the finite element analysis program of ANSYS was used to evaluate the structural safety of the modified caisson dock and obtain additional structural reinforcement schemes to solve the derived problems. For the floating docks, there are classification regulations; however, concerning structural strength, the regulations are insufficient, and the applicability is inferior. These insufficient evaluation areas were supplemented through a detailed structural FE-analysis. The reinforcement plan was decided by reinforcing the pontoon deck and reinforcement of the side tank, considering the characteristics of the repair shipyard condition. The final plan was selected to reinforce the side wing tank through the structural analysis of the decision; in addition, the actual structure was fabricated to reflect the reinforcement plan. Our results can be used as reference data for improving the structural strength of similar facilities; we believe that the optimal solution can be found quickly if this method is used during renovation/repair.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Improvement of GPS positioning accuracy by static post-processing method (정적 후처리방식에 의한 GPS의 측위정도 개선)

  • 김민선;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.251-261
    • /
    • 2003
  • To measure the GPS position accuracy and its distribution according to the length of the baseline, 30 minutes to 24 hours observations at the fixed location were conducted with two GPS receivers (Ll, 12 channels) on May 29 to June 2, 2002. The GPS data received at the reference station, the rover station and the ordinary times GPS observation station operated by the National Geography Institute in Korea were processed in kinematic and static post-processing methods with a post -processing software. The results obtained are summarized as follows: 1. The number of the satellite that could be observed continuously more than six hours was 16 and most of these satellites were positioned at east-west direction on May 31, 2002. The number of the satellite observed and the geometric dilution of precision (GDOP) determined by the average of every 10 minute for the day were 8 and 3.89, respectively. 2. Both the average GPS positions before and after post-processing were shifted (standalone: 1.17 m, post -processing: 0.43m) to the south and west. The twice distance root mean square (2drms) measured with standalone was 6.65m. The 2drms could be reduced to 33.8% (standard deviation 0=17.2) and 5.3% (0=2.2) of standalone by the kinematic and the static post-processing methods, respectively. 3. The relationship between the length of the baseline x (km) and the 2drms y (m) obtained by the static post-processing method was y=0.00l6x+0.006 $(R^2=0.87)$. In the case of the positioning with the static post-processing method using the GPS receiver, it was found that a positioning within 20cm 2drms was possible when the length of the baseline was less than 100km and the receiving time of the GPS is more than 30 minutes.

Norm-referenced criteria for strength of the elbow joint for the korean high school baseball players using the isokinetic equipment: (Focusing on seoul and gyeonggi-do) (등속성 장비를 이용하여 한국고교야구선수 주관절 근력 평가기준치 설정: (서울 및 경기도 중심으로))

  • Kim, Su-Hyun;Lee, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.442-447
    • /
    • 2017
  • The purpose of this study was to establish norm-referenced criteria for the isokinetic strength of the elbow joint in Korean high school baseball players. Two hundred and one high school baseball players participated in this study, none of whom had any medical problem with their upper limbs. The elbow flexion/extension test was conducted four times at a speed of $60^{\circ}/sec$. The HUMAC NORM (CSMI, USA) system was used to obtain the values of the peak torque and peak torque per body weight. The results were presented as norm-referenced criterion valuesusing the 5-point scale of Cajori which consists of five stages (6.06%, 24.17%, 38.30%, 24.17%, and 6.06%). In the results of this study, the peak torques of the elbow (flexor and extensor?) at an angular velocity of $60^{\circ}/sec$ were $37.88{\pm}8.14Nm$ and $44.59{\pm}11.79Nm$, and the peak torque per body weight of the elbow (flexor and extensor?) were $50.06{\pm}8.66Nm$ and $58.28{\pm}12.84Nm$, respectively. The reference values of the peak torque and peak torque per body weight of the elbow flexor and extensor were setat an angular velocity of $60^{\circ}/sec$. On the basis of the results analyzed in this study, the following conclusions were drawn. There is a lack of proper studies on the elbow joint strength, even though the most common injury in baseball players occurs in the elbow joint. Therefore, we need to establish a standard muscle strength in order to prevent elbow joint injuries and improve their performance. The criteria for the peak torque and peak torque per body weight established here in will provide useful information for high school baseball players, baseball coaches, athletic trainers and sports injury rehabilitation specialists in injury recovery and return to rehabilitation, which can beutilized as objective clinical assessment data.

Development of Korean Healthy Eating Index for adults using the Korea National Health and Nutrition Examination Survey data (국민건강영양조사 자료를 이용한 한국 성인의 식생활평가지수 개발)

  • Yook, Sung-Min;Park, Sohee;Moon, Hyun-Kyung;Kim, Kirang;Shim, Jae Eun;Hwang, Ji-Yun
    • Journal of Nutrition and Health
    • /
    • v.48 no.5
    • /
    • pp.419-428
    • /
    • 2015
  • Purpose: The current study was conducted in order to develop the Korean Healthy Eating Index (KHEI) for assessing adherence to national dietary guidelines and comprehensive diet quality of healthy Korean adults using the 5th Korea National Health and Nutrition Examination Survey (KNHANES) data. Methods: The candidate components of KHEI were selected based on literature reviews, dietary guidelines for Korean adults, 2010 Dietary Reference Intakes for Koreans (2010 KDRI), and objectives of HP 2020. The associations between candidate components and risk of obesity, abdominal obesity, and metabolic syndrome were assessed using the 5th KNHANES data. The expert review process was also performed. Results: Diets that meet the food group recommendations per each energy level receive maximum scores for the 9 adequacy components of the index. Scores for amounts between zero and the standard are prorated linearly. For the three moderation components among the total of five, population probability densities were examined when setting the standards for minimum and maximum scores. Maximum scores for the total of 14 components are 100 points and each component has maximum scores of 5 (fruit intakes excluding juice, fruit intake including juice, vegetable intakes excluding Kimchi and pickles, vegetable intake including Kimchi or pickles, ratio of white meat to read meat, whole grains intake, refined grains intake, and percentages of energy intake from carbohydrate) or 10 points (protein foods intake, milk and dairy food intake, having breakfast, sodium intake, percentages of energy intake from empty calorie foods, and percentages of energy intake from fat). The KHEI is a measure of diet quality as specified by the key diet recommendations of the dietary guidelines and 2010 KDRIs. Conclusion: The KHEI will be used as a tool for monitoring diet quality of the Korean population and subpopulations, evaluation of nutrition interventions and research.

Consideration of a Bacteria Contamination Management in the Dispensation of 99mTc Radiopharmaceutical (테크네슘 방사성의약품의 조제와 분배 과정에서 오염균에 대한 고찰)

  • Choi, Do Chul;Gim, Yeong Su;Jo, Gwang Mo;Gim, Hui Jeong;Seo, Han Gyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.84-87
    • /
    • 2018
  • Purpose The radiopharmaceutical used in the nuclear medicine department is used only for the specific patient according to the prescription or instruction of the doctor without selling, so it is dispensed and it is distributed and used for the examination. Radiopharmaceuticals administered to patients should be managed appropriately as well as radiation safety management during dispensation. The purpose of this study is to investigate microbial contamination during dispensation of radiopharmaceuticals Materials and Methods This study distinguished between general workbench and clean workbench and performed three tests. First, microbial cultivation test of radiopharmaceutical prepared and dispensed in general workbenches and sterile workbenches were carried out five times, respectively. The second test was performed settle plate method three times before and after the use of the exhaust filter. Finally, Adenosine Triphosphate (ATP) measurement was performed in each workbench to measure bacterial counts. In addition, ATP measurement were carried out by designating locations and items that may be contaminated during dispensation. Results In the microbial culture test, no microorganisms were detected in both samples. In the settle plate method, it was detected without using of the exhaust filter in a general workbench once. In the ATP measurement test, it was measured at the level of 400 RLU or less, which is the standard value of contamination, in both workbenches surface. In additional ATP measurement test, the refrigerator handle in the distribution room was measured above the reference value of 1217 RLU, the vacuum vial shield of the Tech Generator at 435 RLU, and the syringe holder at 1357 RLU. After environmental disinfection, the results were reduced to 311 RLU, 136 RLU, and 291 RLU. Conclusion No contamination by bacteria was found in both workbenches. However, microbial contamination may occur if the use of an exhaust filter or proper hand hygiene is not achieved. Regular inspections and management for aseptic processing themselves will be necessary.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

Development of nutrition quotient for Korean preschoolers (NQ-P): Item selection and validation of factor structure (취학전아동 대상 영양지수 개발 : 평가항목 선정과 구성 타당도 검증)

  • Lee, Jung-Sug;Kang, Myung-Hee;Kwak, Tong-Kyung;Chung, Hae Rang;Kwon, Sehyug;Kim, Hye-Young;Hwang, Ji-Yun;Choi, Young-Sun
    • Journal of Nutrition and Health
    • /
    • v.49 no.5
    • /
    • pp.378-394
    • /
    • 2016
  • Purpose: Screening of preschool-age children for nutrition programs to improve dietary intake and behaviors requires cost-effective and easily administered validated assessment tools. The purpose of this study was to develop a parent/caregiver-administered instrument for measuring diet quality and behaviors of preschoolers as a nutrition quotient for preschoolers (NQ-P). Methods: Development of NQ-P was carried out in three steps: item generation, item reduction, and validation. The 24-h dietary record was selected as the gold standard reference tool. The 38 items of the NQ-P checklist were derived from a systematic literature review, expert in-depth interviews, statistical analysis of the fifth Korean National Health and Nutrition Examination Survey data, and national nutrition policies and recommendations. Self-administered questionnaires were delivered to parents who recorded 24-h dietary intakes of 100 responders aged 3~5 yr. Pearson's correlation was used to measure the level of agreement between questionnaires. Item reduction was performed, and 20 items were selected based on survey results, expert reviews, and priorities of national nutrition policy and recommendations. The 412 nationwide subjects sampled through daycare centers completed the 20-item checklist questionnaire. The construct validity of the NQ-P was assessed using confirmatory factor analysis, LISREL. Results: After analyses of exploratory factors, NQ-P items identified three dimensions of diet (balance, moderation, and environment). The three-factor structure accounted for 49.28% of the total variance. Standardized path coefficients were used as weights of the items. The NQ-P and three-factor scores of the subjects were calculated by the obtained weights of the questionnaire items. Conclusion: A food behavior checklist for preschoolers' NQ would be a useful and suitable instrument for evaluating nutrition adequacy and dietary quality of Korean preschoolers.

A Comparison between BSCS's Guide and the Korean Curriculum for Developing Biological Literacy (생물학적 소양의 함양을 위한 BSCS 통합 권고안과 6,7차 교육과정 비교)

  • Koo, Soo-Jeong;Kim, Young-Shin;Kim, Byung-Suk;Lee, Sung-Jo;Chung, Wan-Ho
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.3
    • /
    • pp.396-410
    • /
    • 2000
  • In this study, the concept presentation form, the content coherence of sub-dimensional concepts and the number of concepts of the 6th and the 7th Korean curriculum were analyzed comparing the guide to developing the secondary biology curricula to develop biological literacy with BSCS. According to the result, the discrimination between concept levels in the frame of contents of the Korean curricula is insufficient, because each of concepts presented in the knowledge domain as upper level and sub-dimensional concept elements as lower level are simply arrayed. Considering too much concepts of ecosystem, genetics, reproduction and metabolism, there should be an effort to reform the biological curriculum to include concepts evenly, not in the biased state, to reflect all the 6 unifying principles by BSCS for developing students' biological literacy. Finally there should be an effort to reflect the characteristics of each subjects concretely among Science 10, Biology I and Biology IT in the 7th curriculum considering the result that essential concepts to develop biological literacy are presented more in some principles of Biology II than Biology I. Thinking the results of the present study, concrete discussions should be made to set up the standard reference about biological literacy and to present essential concepts for teaching and learning to develop it in the process of biology textbook development for meeting the 7th Korean curriculum and in the development of 8th Korean curriculum in advance.

  • PDF