• Title/Summary/Keyword: the standard of reference

Search Result 2,150, Processing Time 0.03 seconds

Development of Standard Method for Quality Innovation to Strengthen Global Competitiveness and Create Management Performance of Small and Medium-sized Manufacturing Firms (중소 제조기업의 글로벌 품질경쟁력 강화 및 경영성과 창출을 위한 품질혁신 표준방법론 개발)

  • Park, Jong Kab;Kim, Youn Sung
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.4
    • /
    • pp.843-862
    • /
    • 2018
  • Purpose: The purpose of this study was to develop quality innovation techniques specialized for the small and medium-sized businesses. which account for the majority of Korean companies, were having a hard time utilizing the widely recognized quality innovation techniques due to resource constraints. Methods: First, we do review the existing Single PPM and 6 Sigma. And investigate the utilization of these methods including Toyota Production System. Second, we devised a four-step problem-solving methodology based on recent trends in quality innovation such as Simple, Speedy, and Smart. Third, we do survey on frequently used tools for quality innovation. Many opinion leaders including quality consultants and professors answered and gave us valuable comments about our selected quality tools. Finally, we do specify and map tools to each step of PASS. Results: In 2017, 167 companies participated in the quality innovation support business for small businesses according to the Korea Chamber of Commerce & Industry. We conducted performance checks on 167 companies that had completed the "PASS" projects. For the purpose of evaluating improvement performance, the survey was carried out using a structured questionnaire during the field visit of these companies mentioned above. For the reference, 165 out of 167 companies (98.8 % response rate) responded to the questionnaire and conducted performance analysis based on it. According to the survey, 97.6 percent of the respondents were very satisfied with their overall satisfaction with the quality innovation support projects for small and medium sized enterprises in 2017. Also, 93.3 % of the respondents were satisfied with the results of level of the target achievement. As a result, 160 companies (97.0 % of the participating companies) hope to partic ipate in the quality improvement project using "PASS" once again. Conclusion: In this paper, we introduce the new quality innovation methodology, which is named as 'PASS', It could support the long-range business plan of the small and medium-sized businesses to achieve total customer satisfaction resulting in increased market share and improved profit margin. The most small companies can use this "PASS" technique more easily, quickly and most efficiently than their existing known quality innovation techniques such as Six Sigma and Single PPM, etc.

A Comparative Analysis of Whole Blood Cadmium by Atomic Absorption Spectrophotometry with a Graphite Furnace (흑연로 원자흡수분광법에 의한 혈액중 카드뮴 정량분석)

  • Park, Jong An;Oh, Hye Jeong;Lee, Jong Hwa
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.301-312
    • /
    • 1996
  • This study was performed to search a optimal analyzing method of cadmium in whole-blood. Cadmium was determined by graphite furnace atomic absorption spectrometry(GFAAS). We investigated the effect of ashing temperature on the absorbance of cadmium in a simple dilution(ten-fold) method with triton X-100 and matrix modifier methods treated with $NH_4H_2PO_4$(1 and 3%) and $Pd(NO_3)_2$(0.00l and 0.005%) as matrix modifier. We also compared the reported reference values of standard blood with values resulted from optimal analyzing conditions of this study. In case of a simple dilution method, when ashing temperature was set at $450^{\circ}C$, the absorbance of sample and background were $0.334{\pm}0.012$ and $1.382{\pm}0.245$, respectively. Background level was higher than the value(0.8) that can be corrected by $D_2$ background correction method. As ashing temperature was rised to $500^{\circ}C$, the absorbance of sample and background were $0.178{\pm}0.008$ and $0.711{\pm}0.223$ respectively. The higher ashing temperature($450^{\circ}C-650^{\circ}C$) was, the lower the absorbance of sample was. In case of a matrix modifier method with $NH_4H_2PO_4$(1 and 3%), when ashing temperature was rised from $500^{\circ}C$ to $650^{\circ}C$, the absorbance of sample slightly changed. The absorbances of sample at $600^{\circ}C$ were $0.230{\pm}0.017$ and $0.137{\pm}0.012$, respectively. These values were larger than that of simple dilution method. But the absorbance of background was higher than the level that can be corrected by $D_2$ method. In case of a matrix modifier method with $Pd(NO_3)_2$(0.001 and 0.005%), the absorbance of sample and background were higher than those of other methods and were stable and reproducible. When ashing temperature was over $550^{\circ}C$, the absorbance of sample was significantly decreased. In case of 0.005% $Pd(NO_3)_2$ carbon residue remained in graphite tube affected the absorbance of sample and background. From these results, We propose that in case of a simple dilution(ten-fold) method with triton X-100 ashing temperature must be maintained below $400^{\circ}C$. In order to diminish the absorbance of background, the alternative method is attenuation of injection volume or multiplication of dilution ratio. We recommend $Pd(NO_3)_2$ than $NH_4H_2PO_4$ as a matrix modifier. In case of a matrix modifier method with $Pd(NO_3)_2$ ashing temperature might be maintained below $550^{\circ}C$.

  • PDF

A Pilot Study on Installation Criteria of Speed Change Lanes according to the Implementation of Safety Speed "5030" in the Urban Area (도심내 안전속도 "5030"시행에 따른 변속차로 설치기준에 관한 기초연구)

  • Oh, Seok-Jin;Ha, Tae-Jun;Jin, Tae-Hee;Shin, Kwang-Min;Lee, Gang-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.57-64
    • /
    • 2021
  • The speed change lane is installed at the point where the roads are connected on the urban roads, reducing the relative speed to facilitate traffic communication. However, in the case of the speed limit of 30 km/h in accordance with the implementation of the safe speed "5030" in the city, the standard is ambiguous, and there are criticisms about the installation of the transmission lane. This study conducted a pilot study on the traffic patterns of the speed change lanes, focusing on the section where the safe speed "5030" policy was scheduled to be implemented after theoretical consideration of the speed change lanes. After on-site investigation, as a result of analyzing the traffic pattern according to the travel speed of the main road according to road conditions and traffic conditions, the effectiveness of the speed change lane according to the safety speed "5030" was analyzed. In this study, the installation criteria for speed change lane by speed were presented. The criteria is that "speed change lanes should not be installed when the speed limit is 30 km/h, and speed change lanes should be installed when the speed limit is 50 km/h." The criteria will be considered as a reference when establishing engineering standards for connection of other facilities in urban areas in the future. It is expected that unnecessary restrictions on individuals' exercise of private property rights will be minimized, smooth traffic flow and secure safety by the installation of speed change lanes and expansion of turning radius.

Korean Clinical Practice Guidelines for Aneurysmal Subarachnoid Hemorrhage

  • Cho, Won-Sang;Kim, Jeong Eun;Park, Sukh Que;Ko, Jun Kyeung;Kim, Dae-Won;Park, Jung Cheol;Yeon, Je Young;Chung, Seung Young;Chung, Joonho;Joo, Sung-Pil;Hwang, Gyojun;Kim, Deog Young;Chang, Won Hyuk;Choi, Kyu-Sun;Lee, Sung Ho;Sheen, Seung Hun;Kang, Hyun-Seung;Kim, Byung Moon;Bae, Hee-Joon;Wan, Chang;Park, Hyeon Seon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.127-166
    • /
    • 2018
  • Despite advancements in treating ruptured cerebral aneurysms, an aneurysmal subarachnoid hemorrhage (aSAH) is still a grave cerebrovascular disease associated with a high rate of morbidity and mortality. Based on the literature published to date, world-wide academic and governmental committees have developed clinical practice guidelines (CPGs) to propose standards for disease management in order to achieve the best treatment outcomes for aSAHs. In 2013, the Korean Society of Cerebrovascular Surgeons issued a Korean version of the CPGs for aSAHs. The group researched all articles and major foreign CPGs published in English until December 2015 using several search engines. Based on these articles, levels of evidence and grades of recommendations were determined by our society as well as by other related Quality Control Committees from neurointervention, neurology and rehabilitation medicine. The Korean version of the CPGs for aSAHs includes risk factors, diagnosis, initial management, medical and surgical management to prevent rebleeding, management of delayed cerebral ischemia and vasospasm, treatment of hydrocephalus, treatment of medical complications and early rehabilitation. The CPGs are not the absolute standard but are the present reference as the evidence is still incomplete, each environment of clinical practice is different, and there is a high probability of variation in the current recommendations. The CPGs will be useful in the fields of clinical practice and research.

A study of activity ratios of uranium isotope in the groundwater using liquid scintillation counter (액체섬광계수기를 이용한 지하수 내 우라늄 동위원소 측정법에 관한 연구)

  • Cho, Soo-Young;Song, Kyung-Sun;Lee, Kil-Yong;Yoon, Yoon-Yeol;Kim, Won-Baek;Ko, Kyung-Sok
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.146-151
    • /
    • 2012
  • An analytical method was developed for the measurement of uranium isotope in ground water using the liquid scintillation counting technique. A LKB Wallac Quantulus 1220 liquid scintillation counter (LSC) equipped with pulse shape analyzer (PSA) and a solvent extraction method were used for the measurement of uranium isotope in ground water samples. The effect of solution volume on the extraction efficiency was evaluated for 100 to 1000 mL solutions using a NIST standard reference material (NIST SRM 4321C). The effect of groundwater pH on the extraction efficiency was also investigated for pH ranging from 0.5 to 10. It was found that the extraction efficiency had a strong dependence on pH showing a maximum at pH 2. In contrast, the effect of groundwater volume on the extraction efficiency was negligible in the range investigated. According to the method, the extraction efficiency of uranium isotopes was near 96% and the lower detection limit for uranium was 0.018 Bq/L with the counting time of 300 min. The result of this study was also verified by the conventional ICP-MS measurement. It is demonstrated that the suggested method is valuable to the determination of the optimum extraction and measurement conditions for uranium in ground water. The method was successfully applied to the ground water at four locations near the Daejeon province. It was found that the uranium content and the isotopic ratio of $^{234}U/^{238}U$ at the locations ranged 0.59~6.69 Bq/L and 0.72~1.40, respectively.

Development of 3-D Stereotactic Localization System and Radiation Measurement for Stereotactic Radiosurgery (방사선수술을 위한 3차원 정위 시스템 및 방사선량 측정 시스템 개발)

  • Suh, Tae-Suk;Suh, Doug-Young;Park, Sung-Hun;Jang, Hong-Seok;Choe, Bo-Young;Yoon, Sei-Chul;Shinn, Kyung-Sub;Bahk, Yong-Whee;Kim, Il-Hwan;Kang, Wee-Sang;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.25-36
    • /
    • 1995
  • The purpose of this research is to develop stereotactic localization and radiation measurement system for the efficient and precise radiosurgery. The algorithm to obtain a 3-D stereotactic coordinates of the target has been developed using a Fisher CT or angio localization. The procedure of stereotactic localization was programmed with PC computer, and consists of three steps: (1) transferring patient images into PC; (2) marking the position of target and reference points of the localizer from the patient image; (3) computing the stereotactic 3-D coordinates of target associated with position information of localizer. Coordinate transformation was quickly done on a real time base. The difference of coordinates computed from between Angio and CT localization method was within 2 mm, which could be generally accepted for the reliability of the localization system developed. We measured dose distribution in small fields of NEC 6 MVX linear accelerator using various detector; ion chamber, film, diode. Specific quantities measured include output factor, percent depth dose (PDD), tissue maximum ratio (TMR), off-axis ratio (OAR). There was small variation of measured data according to the different kinds of detectors used. The overall trends of measured beam data were similar enough to rely on our measurement. The measurement was performed with the use of hand-made spherical water phantom and film for standard arc set-up. We obtained the dose distribution as we expected. In conclusion, PC-based 3-D stereotactic localization system was developed to determine the stereotactic coordinate of the target. A convenient technique for the small field measurement was demonstrated. Those methods will be much helpful for the stereotactic radiosurgery.

  • PDF

Markov Chain Properties of Sea Surface Temperature Anomalies at the Southeastern Coast of Korea (한국 남동연안 이상수온의 마르코프 연쇄 성질)

  • Kang, Yong-Q.;Gong, Yeong
    • 한국해양학회지
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 1987
  • The Markov chain properties of the sea surface temperature (SST) anomalies, namely, the dependency of the monthly SST anomaly on that of the previous month, are studied based on the SST data for 28years(1957-1984) at 5 stations in the southeastern coast of Korea. Wi classified the monthly SST anomalies at each station into the low, the normal and the high state, and computed transition probabilities between SST anomalies of two successive months The standard deviation of SST anomalies at each station is used as a reference for the classification of SST anomalies into 3states. The transition probability of the normal state to remain in the same state is about 0.8. The transition probability of the high or the low states to remain in the same state is about one half. The SST anomalies have almost no probability to transit from the high (the low) state to the low (the high) state. Statistical tests show that the Markov chain properties of SST anomalies are stationary in tine and homogeneous in space. The multi-step Markov chain analysis shows that the 'memory' of the SST anomalies at the coastal stations remains about 3 months.

  • PDF

Comparative Study of Metro Service in Korea Using Servicescape (서비스스케이프를 활용한 한국의 지하철 서비스 비교연구)

  • Jia-Xing Long;Sung-Pil Lee
    • Journal of Service Research and Studies
    • /
    • v.12 no.2
    • /
    • pp.48-64
    • /
    • 2022
  • The metro played a role in improving and alleviating the problems of urban ground transportation, promoting rational development of the city and at the same time leading the development of metro-related industries. There is no doubt that it had a double effect of enormous economic and social benefits on the development of the country as a whole. The purpose of this study is to apply the concept of servicescape to the metro and establish the definition of the Metro Servicescape(MSS). To this end, the service space and service facilities of the metro were analyzed, and the existing domestic and foreign literature related to servicescape was studied. First, this study defined the concept of servicescape of metro. Second, 10 elements suitable for the metro service landscape were derived through domestic and foreign service landscape studies. Third, through field surveys and analysis of metros in five cities in Seoul, Busan, Daegu, Daejeon, and Gwangju, the ranking of the current status of the domestic metro servicescapes was 203 Seoul metro, 197 Busan metro, 192 Daegu metro, 178 Gwangju metro, There were 172 metro lines in Daejeon. Among them, the four elements of comfort, sociality, cleanliness, and safety are the same, and accordingly, it seems that each city metro is the same standard. However, the six elements of aesthetics, spatiality, convenience, entertainment, openness and information were found to be different for each city metro. It is expected that the results of this study can provide a reference value for future metro service landscape research.

Laboratory Evaluation of the Accuracy, Precision, and Inter-instrumental Variance of a Portable Photoionization Detector (휴대용 광이온화 검출기의 정확도, 정밀도 및 기기간 차이에 대한 실험실 평가)

  • Choi, Dongmin;Choi, Youngeun;Yoon, Chungsik;Rhie, Kwangwon;Lee, Yunkeun;Lee, Ikmo;Park, Jeongim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.200-208
    • /
    • 2012
  • Objectives: This study investigated the performance of three separate units of a portable photoionization detector (PID, ppb-RAE 3000) for measuring volatile organic compounds (VOCs) in a laboratory. Methods: A laboratory evaluation of the accuracy, precision, and inter-instrumental variance of three separate units of a portable PID (ppb-RAE 3000) was performed. The evaluation was based on the preparation of a test air sample of known toluene or ethylacetate concentration in a Tedlar$^{(R)}$ bag. The test air sample was monitored and data were logged consecutively by the three PIDs. A certified gas of 50 ppm toluene was also monitored during the test to ensure the reliability of the generated test air sample. Four different concentrations ranging from 0.1 to 2 TLV were used and a series of five measurements for each concentration level was performed. The accuracy was evaluated using National Institute for Occupational Safety and Health (NIOSH) criteria. Results: The results from the oldest ppb-RAE3000 unit among the three test units generally fell outside the NIOSH recommended accuracy criteria of ${\pm}25%$, whereas the other two units produced results which were acceptable at, or greater than, 25 ppm of toluene, or 0.5 TLV. These units also met the NIOSH criteria for some ethylacetate measurements but the results were not consistent. Conclusions: Considering the inconsistent performance of these ppb-RAE 3000 units, this device may not be appropriate for use as an alternative to the standard measurement methods. However, it can serve good survey instruments to identify exposure sources or concentration profiles. For all applications, the ppb-RAE 3000 should be used with frequent calibration checks, additional validation using a reference material, and careful maintenance.

A Study on 3D Model Building of Drones-Based Urban Digital Twin (드론기반 도심지 디지털트윈 3차원 모형 구축에 관한 연구)

  • Lim, Seong-Ha;Choi, Kyu-Myeong;Cho, Gi-Sung
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.1
    • /
    • pp.163-180
    • /
    • 2020
  • In this study, to build a spatial information infrastructure, which is a component of a smart city, a 3D digital twin model in the downtown area was built based on the latest spatial information acquisition technology, the drone. Several analysis models were implemented by utilizing. While the data processing time and quality of the three types of drone photogrammetry software are different, the accuracy of the construction model is ± 0.04 in the N direction and ± 0.03m in the E direction. In the m and Z directions, ± 0.02m was found to be less than 0.1m, which is defined as the allowable range of surveying performance and inspection performance for the boundary point in the area where the registration of the boundary point registration is executed. 1: 500 to 1 of the aerial survey work regulation: The standard deviation, which is the error limit of the photographic reference point of the 600 scale, appeared within 0.14 cm, and it was found that the error limit of the large scale specified in the cadastral and aerial survey was satisfied. In addition, in order to increase the usability of smart city realization using a drone-based 3D urban digital twin model, the model built in this study was used to implement Prospect right analysis, landscape analysis, Right of light analysis, patrol route analysis, and fire suppression simulation training. Compared to the existing aerial photographic survey method, it was judged that the accuracy of the naked eye reading point is more accurate (about 10cm) than the existing aerial photographic survey, and it is possible to reduce the construction cost compared to the existing aerial photographic survey at a construction area of about 30㎢ or less.