• 제목/요약/키워드: the standard body measurement

검색결과 268건 처리시간 0.039초

신체치수와 제품치수의 차이로 본 타이트 스커트의 구성 실태분석 (An Analysis to the Actual Condition of Tight Skirts Construction According to the Difference Between Body Size and Products Size)

  • 정옥임
    • 대한가정학회지
    • /
    • 제38권1호
    • /
    • pp.1-8
    • /
    • 2000
  • In this study 61private brand skirts and 67 brand name skirts were compared to see if the skirts from the different markets were suitable for both comfort and movement. The researcher chose size 66 skirts with a waist circumference of 68~70cm and hip circumference of 92cm. The resets are as follows. (1) In the waist measurement, the minor brand skirts were made at the maximum measurement (70cm) and the department store brand skirts were at the minimum (68cm). (2) Compared with the standard back split length of 9cm for a 48cm-long skirt, the minor brand skirts had a split of only 4.5cm, while the department store brand skirts were 3cm less (split length-6cm). From this result, we see that both of them are less practical than they are supposed to be (3) For the department store skirts, the hip circumference and waist circumference show a significant correlation to skirt length (p<0.05) and back split length (p<0.001). Larger waist & hip measurements equal longer split length. For the minor brand skirts, the length of the split shows a significant correlation to the depth of the hem-line Shorter split equals smaller hem depth. From these results, it can be concluded that the two groups of skirts do not differ except for back split length and waist circumference, but regarding the split length, both of them should be modified for else of movement and comfort.

  • PDF

The AS4059 Hydraulic System Cleanliness Classification System: Replacement of NAS1638

  • 마이크 데이;홍정희
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권2호
    • /
    • pp.39-45
    • /
    • 2012
  • The NAS 1638 cleanliness classification system was originally developed in 1966 by the US Aircraft Industries of America to both simplify reporting of particle count data and to control the introduction of dirt during the assembly of aircraft fluid systems. The numbers of particles at stated sizes are represented by broad bands where the interval was generally a doubling of contamination. A number of systems have been introduced since this to suit differing requirements. NAS 1638 and AS4059 are used in other industrial sectors such as the Off-shore & Sub-Sea and the Primary Metal Industries. The changes to ISO contamination measurement standards controlled by ISO/TC131/SC6 in 1999 meant that a revision of most of these classification systems was necessary. The body responsible for NAS 1638 decided to withdraw it for new installations and replace it with an update of an existing standard, SAE AS 4059. This paper details the philosophy behind the contamination coding systems, the reasons for the changes to the ISO contamination standards and explains the workings of AS 4059, the replacement for NAS 1638. It goes on to detail the latest changes to this standard.

TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구 (A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System)

  • 이건호;정진수;문현욱;김선구
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

파라메트릭 프로덕션 패턴 제작을 위한 상의 누드 패턴 개발 (Development of Nude Pattern on Top for Producing Parametric Production Patterns)

  • 김나래;남윤자;박진희
    • 한국의류학회지
    • /
    • 제43권5호
    • /
    • pp.711-724
    • /
    • 2019
  • The automatic drafting of clothing patterns can be realized through an Apparel Cad System when the clothing pattern has a pattern expression in human dimensions. However, it is difficult to apply automatic systems because it is difficult to express the ready-to-wear of various complex designs with one system. This study develops ready-to-wear patterns in an automatic drafting style and also develops nude patterns with human dimension-based drafting styles that can be applied to enable the setting of margins by design. For this purpose, radial body length measurement items and measurement methods were newly defined for female standard dummy and nude pattern systems. The institutional program was developed through the principle of a nude pattern system which is different from the pattern system of the existing system. The nude pattern developed in this study represents a basis and framework for the gradual transformation of the production pattern into the automatic system of the future and as a pattern having an institutional formula based on human dimensions.

THE MEASUREMENT OF FAT THICKNESS IN LIVE CATTLE WITH AN ULTRASONIC DEVICE AS A PREDICTOR OF CARCASS COMPOSITION

  • Mitsuhashi, T.;Mitsumoto, M.;Yamashita, Y.;Ozawa, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제3권4호
    • /
    • pp.263-267
    • /
    • 1990
  • The fat thicknesses of twenty-eight Japanese Black beef steers were measured with an ultrasonic device at eleven points on the cattle prior to slaughter and side dissection. The relation between live fat thickness and both weight and percentage of fat and lean in the carcass was examined. Fat thickness obtained from nine points of the chest, flank and rump regions was found to relate significantly (P<0.01) to both weight and percentage of fat. However, shoulder fat thickness measurements were not significantly related to the weight or percentage of fat or lean in the carcass. Addition of live fat thickness to animal age or live weight as an independent variable markedly improved the precision of multiple regression equations for predicting weight of fat and lean, and percentage of fat. In predicting the percentage of lean, both animal age and body weight were not employed in the multiple regression equation. The residual standard deviation for predicting percentage of fat and lean were 1.93 and 1.87, respectively. The ultrasonic measurement of fat thickness if supposed to be useful to the prediction of carcass composition of beef cattle.

Comparative Analysis of Dynamic Moisture Movement Testers

  • Lee, Duck-Weon;Shim, Woo-Sub;Lim, Ho-Sun
    • 패션비즈니스
    • /
    • 제15권6호
    • /
    • pp.40-55
    • /
    • 2011
  • The purpose of this research is to review testing principle, testing design and experimental results of the four dynamic moisture movement testers. The research analyzes Moisture Manager Tester (MMT), Alambeta Instrument, Dynamic Surface Moisture Movement Tester, and Gravimetric Absorbent Testing Method based on American Society for Testing and Material (ASTM) E 96 which is an international standard testing method. Although many of researches use ASTM E 96 to measure moisture movement on a fabric, it has several weaknesses, such as long experimental time and a physical change of sample by a holder of the frame. Hence, lots of researchers have studied and developed the new measurement systems measuring moisture management on a fabric or garment and ultimately mimic heat energy and perspiration created by the human body. These moisture management systems use a variety of parameters, such as electricity, color, and sensor to measure their movement in the fabric. Through comparison with the existing tester (ASTM E 96), the research recognizes the strength and weakness in the dynamic moisture movement testers.

전립선암 선별을 위한 PSA 측정의 보험의학적 의미 (Review of measurement of prostate specific antigen: in the aspect of insurance medicine)

  • 박광일
    • 보험의학회지
    • /
    • 제29권1호
    • /
    • pp.16-21
    • /
    • 2010
  • The measurement of prostate specific antigen (PSA) in screening for prostate cancer is recently performed as a routine check-up in clinical medicine and insurance medicine. Several factors may affect serum PSA levels. As prostate size increases with increasing age, the PSA concentration also rises. Increasing body mass index (BMI) is associated with a lower mean PSA concentration. Inhibitors of 5-alpha-reductase such as finasteride and dutasteride produce a 50 percent or greater decrease in serum PSA during the first three months of therapy, which persists as long as the drug is continued. Men who are regularly taking non-steroidal antiinflammatory drugs (NSAIDs) or acetaminophen have lower PSA levels. Emerging concepts regarding PSA testing that may help refine the interpretation of an elevated concentration include: PSA density, PSA velocity, and Free versus complexed or bound PSA. With many insurance companies, PSA level has become part of a standard battery of blood tests, along with HIV, cholesterol, liver enzymes, and other predictors of premature death. But, there is no clear proof of benefit, so we have to monitor the value of PSA test as a prostate cancer screening test in insurance medicine.

  • PDF

남.여 중학생의 체형인식에 따른 외모관리 항동 비교연구 -광주시내 남.여 공학 중학생을중심으로- (A Comparison of Appearance management Behaviors of middle school boys with girls in relation to the Perception of Body Size -Among girls and boys' middle school in Gwangju-)

  • 위은하
    • 한국가정과교육학회지
    • /
    • 제18권3호
    • /
    • pp.119-131
    • /
    • 2006
  • 본 연구에서는 남, 여 중학생의 체형인식에 딱른 외모관리 행동의 실태를 파악하고 비교 분석하여 청소년의 긍정적인 신체이미지 형성의 바람직한 방향을 제시하고자 하였다 조사 대상자는 광주소재 남 여 공학 중학교 7곳의 2. 3학년에 재학중인 435명의 남, 여중학생이었다. 결과분석은 SPSS Package 12.0(Kr)을 활용하였다. 그 결과를 요약하면 다음과 같았다. 먼저, 남, 여중학생들은 실제체형보다 비만하게 인식하는 것뿐만 아니라 실제체형보다 수척하게 인식하는 경향도 컸다. 자신의 체형을 제대로 인식할 수 있는 교육이 필요하다고 본다. 둘째, 신체인식 요인과 외모관리행동의 상관관계를 살펴보면 남, 여 중학생 모두 비만인식에 대해 운동보다는 다이어트로 외모관리를 하는 경향을 보이는데 이것에 대한 적절한 지도가 필요하다고 생각된다. 셋째, 자신의 실제체형보다 수척하게 인식하는 수척왜곡 인식집단과 정상집단의 외모관리행동을 살펴보면 남중학생은 운동관리만 하고 여중학생은 운동관리만 하지 알았다. 서로 차별화된 교육이 필요하다고 생각된다. 넷째 비만왜곡인식집단은 남 여중학생 모두 다이어트관리를 하는 반면 신체보정관리나 운동관리를 하지 않는 경향을 보였다. 실제적으로 운동관리가 가장 필요하다고 인식해야할 집단이 다이어트에만 의존하는 경향은 시정이 꼭 필요하다고 생각된다. 이상과 같이 우리나라 남 여 중학생의 왜곡된 신체인식과 외모관리행동을 바로 잡기 위해서 정규 교과목인 가정과목을 통해 표준체형에 대한 교육이 이루어져야 할 것이며 자신의 실제체형을 올바르게 인식할 수 있도록 하는 지도가 병행되어야 할 것으로 생각된다.

  • PDF

금속 밀링과 직접 금속 레이저 소결 방식으로 제작한 3본 코발트-크롬 구조물의 변연 및 내부 적합도 비교 평가 (Comparative evaluation of marginal and internal fit of three-unit Co-Cr frameworks fabricated by metal milling and direct metal laser sintering methods)

  • 안재석;이정환
    • 대한치과기공학회지
    • /
    • 제42권2호
    • /
    • pp.81-89
    • /
    • 2020
  • Purpose: This in vitro study was conducted to evaluate the marginal and internal fit of three-unit Co-Cr frameworks fabricated by computer-aided metal milling and direct metal laser sintering(DMLS) systems in comparison to conventional casting method. Methods: Three-unit Co-Cr frameworks were fabricated by conventional wax up with casting(CWC), computer-aided metal milling(MM) and direct metal laser sintering(DMLS)(n=10 each). The marginal and internal fit of specimens were examined using a light-body silicone impression material. The thickness of light-body silicone was measured at eight reference points each, divided in the mesio distal and bucco lingual directions. All measurements were conducted by a stereomicroscope. Digital photos were taken at 150× magnification and then analyzed using a measurement software. The Kruskal-Wallis test and Bonferroni correction were used for analyzing the results. Results: The mean(SD) is ㎛ for fabrication methods, the mean marginal fit were recorded respectively, DMLS 39(27), followed by CWC 63(38), MM 220(128). and the mean internal fit CWC 95(47), DMLS 116(49), MM 210(152). In addition, the largest gap was found in the occlusal surface area among the internal measurement areas of all groups. Conclusion: As a result, the direct metal laser sintering method showed better marginal and internal fit than the metal milling method. The marginal and internal fit were statistically different according to the three fabrication methods(p<0.001). Except the MM group, the marginal fit of the CWC and DMLS groups was below the clinical standard of 120 ㎛. Based on the results of this study, it can be applied to clinical use in the future.

몰수체 모형 시험 해석을 위한 운동방정식의 구조 선택 및 계수 식별 결합법 (The Combined Method of Structure Selection and Parameter Identification of Equations of Motion to Analyze the Model Tests of a Submerged Body)

  • 김찬기
    • 대한조선학회논문집
    • /
    • 제35권2호
    • /
    • pp.20-28
    • /
    • 1998
  • 몰수체의 운동을 정확하게 예측하기 위해서는 동적 모형의 비선형 구조를 선택하고, 이에 해당하는 조종계수를 모형 시험을 통해 추정하여야 한다. 모형 구조가 주어지면 조종계수들의 값만이 미지수가 되어 추정은 표준 최소 자승 문제로 정식화될 수 있다. 불행하게도 몰수체들의 비선형모형 구조는 거의 알려지지 않고 있다. 따라서, 모형 시험에서 측정된 자료들로부터 운동 방정식의 구조를 결정하는 방법을 개발하여 계수 추정 절차에 중요한 한 부분으로 포함시켜야 한다. 본 연구에서는 모형 시험 결과 해석을 위해 널리 사용되고 있는 최소 자승 알고리즘과 그 성능평가법에 대해 살펴보고, Gram-Schmidt에 의한 직교 분리법에 기초를 둔 계수 식별 알고리즘을 매우 단순하고 효과적으로 구조 선택법과 계수 추정법을 결합할 수 있도록 확장하였다. 마지막으로 시뮬레이션과 실제 몰수체에 대한 모형 시험 자료로의 적용을 통해 이 기법의 성능을 검증하였다. 결론적으로 본 연구의 방법은 모형 시험 결과로부터 효율적으로 운동 방정식의 구조를 식별하고 조종 계수를 추정함을 확인하였다.

  • PDF