• Title/Summary/Keyword: the mandibular first molar

Search Result 383, Processing Time 0.024 seconds

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

Effects of titanium and PEEK abutments on implant-supported dental prosthesis and stress distribution of surrounding bones: three-dimensional finite element analysis (티타늄 및 PEEK 지대주 소재가 임플란트 유지 수복물 및 주위 지지골 응력 분포에 미치는 영향: 3차원 유한요소해석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.44 no.3
    • /
    • pp.67-75
    • /
    • 2022
  • Purpose: This study aimed to comparatively evaluate the stress distribution of bones surrounding the implant system to which both titanium and polyetheretherketone (PEEK) abutments are applied using a three-dimensional finite element analysis. Methods: The three-dimensional implant system was designed by the computer-aided design program (CATIA; Dassault Systemes). The discretization process for setting nodes and elements was conducted using the HyperMesh program (Altair), after finishing the design of each structure for the customized abutment implant system. The results of the stress analysis were drawn from the Abaqus program (Dassault Systèmes). This study applied 200 N of vertical load and 100 N of oblique load to the occlusal surface of a mandibular first molar. Results: Under external load application, the PEEK-modeled dental implant showed the highest von Mises stress (VMS). The lowest VMS was observed in the Ti-modeled abutment screws. In all groups, the VMS was observed in the crestal regions or necks of implants. Conclusion: The bones surrounding the implant system to which the PEEK abutment was applied, such as the cortical and trabecular bones, showed stress distribution similar to that of the titanium implant system. This finding suggests that the difference in the abutment materials had no effect on the stress distribution of the bones surrounding implants. However, the PEEK abutments require mechanical and physical properties improved for clinical application, and the clinical application is thought to be limited.

Changes in pre-osteoblast cells associated with non-precious metal cores with dental implants: Pilot test (치과용 임플란트 적용 비귀금속 코어와 관련된 전조골세포의 변화)

  • Park, Jung-Hyun;Kang, Seen-Young;Kim, Jong-Woo;Kim, Jang-Ju;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.63-69
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the non-precious metal core materials used in the dental laboratory to fabricate the implant superstructure by CAD / CAM method. And to observe and compare the morphology and distribution of the osteoblasts in relation to implant osseointegration. Methods: In this study, the mandibular right first molar tooth model was selected as an international standard to produce a single core. Using this model, the impression was made with the silicone rubber, the tooth model was scanned, and a single core was designed and 5-axis milling was performed. The materials used were Cobalt-Chromium and Nickel-Chromium, and the cores for dental implant top structures were fabricated according to the procedures of the dental labs. After the fabrication, the marginal area of the core was separated and cell culture experiment was performed. The osteoblast cells used MC3T3-E1, which is currently widely used. For morphological analysis of osteoblasts, cells were posttreated and observed using CLSM (Confocal Laser Scanning Microscope) and compared. Results: The cell adhesion behavior of the specimen surface measured by CLSM was uniformly distributed in specimen A (Cobalt-Chromium) than in specimen B (Nickel-Chromium). The distribution and changes of the cells were different in the two specimens. Conclusion : It is possible to confirm that specimen A (Cobalt-Chromium) is suitable for the living body through adhesion and proliferation of osteoblasts related to implant osseointegration in the non-precious metal superstructure used after implantation. It is considered that it is preferable to use Co-Cr when fabricating the superstructure.

A Study on the Computer Assisted Dental Identification in Mass Disaster (대형참사시 컴퓨터를 이용한 법의치과학적 개인식별)

  • Shin, Kyoung-Jin;Choi, Jong-Hoon;Yoon, Chang-Lyuk;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.1
    • /
    • pp.81-94
    • /
    • 1999
  • This study intends to find usefulness of the computer assisted dental identification in mass disaster. The variety of dental characteristics was investigated through the research of dental records of 508 adults. And a computer assisted simulation program was used to evaluate the selectivity of dental identification. Findings were as follows : 1. Combinations of dental characteristics were found 155 types. The most various dental characteristic was showed on the mandibular first molar. 99.0% of subjects had dental characteristics for dental identification. 2. The posterior teeth, in comparison with anterior teeth, showed higher selectivity in dental identification which was enhanced by information on the material, type and cavity of the restoration. 3. The variety of dental characteristics was mainly found on the combinations of missing tooth with the material, type and cavity of the restoration. 4. The computer assisted dental identification program, with informa- tion about one's tooth state, made individual identification possible when there was only a part of the teeth in a corpse. 5. The computer assisted dental identification had considerably high selectivity based on the variety of dental characteristics. And it was also performed faster and preciser than the existing identification methods. Based on the results of this study, there are various combinations of the feature of the tooth itself with dental characteristics caused by a certain type of treatment on the teeth. And using the computer assisted dental identification program based on this, dental identification can be more efficient economically and more useful than any other forensic identification methods.

  • PDF

AN ELECTRON MICROSCOPIC STUDIES OF RADIATION EFFECTS ON THE ENAMEL DEVELOPMENT OF THE RAT MOLAR (방사선조사가 백서구치법랑질발육에 미치는 영향에 관한 전자현미경적 연구)

  • Cho Hyo-Suck;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.483-499
    • /
    • 1995
  • Mandibular first molars of the rats were undertaken to observe the radiosensitivity of amelogenesis. Twenty four Sprague-Dawley rats received 396cGy radiation with the MK Cell irradiator using Cs-137, and twenty four rats served as control. They were devided into two groups; Group 1 which received radiation at the 14th day after gestation and group 2 which received radiation at the 19th day after gestation. Light Microscopy and Transmitted Electron Microscopy investigation was undertaken in the group 1 at the 15th, 18th, 20th, 22nd(2 days after birth), and 25th day(5 days after birth) after gestation, and in the group 2 at the 21th(birth day), 22nd(2 days after birth), and 25th(5 days after birth) day after gestation. The following histopathologic findings were obtained. 1. Compared with control group, experimental group showed a delayed formation of enamel and dentin due to slow rate of differentiation of undifferentiated mesenchymal cells. 2. In the experimental groups, the arrangement of the inner enamel epithelium was irregular and there were many vacuoles in the cytoplasm. There were dilated rER and mitochondria, increase of the intercellular space, and loss of the cellular polarity. 3. In the group 1, early enamel without Tomes' process, and early organic matrix was observed at the 25th day after gestation. 4. In the group 2, histopathologic changes were similar to those of the group 1, but the degree of changes was more severe than that of the group 1.

  • PDF

Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads

  • Kim, Jae-Hoon;Noh, Gunwoo;Hong, Seoung-Jin;Lee, Hyeonjong
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.316-321
    • /
    • 2020
  • PURPOSE. The stress distribution and microgap formation on an implant abutment structure was evaluated to determine the relationship between the direction of the load and the stress value. MATERIALS AND METHODS. Two types of three-dimensional models for the mandibular first molar were designed: bone-level implant and tissue-level implant. Each group consisted of an implant, surrounding bone, abutment, screw, and crown. Static finite element analysis was simulated through 200 N of occlusal load and preload at five different load directions: 0, 15, 30, 45, and 60°. The von Mises stress of the abutment and implant was evaluated. Microgap formation on the implant-abutment interface was also analyzed. RESULTS. The stress values in the implant were as follows: 525, 322, 561, 778, and 1150 MPa in a bone level implant, and 254, 182, 259, 364, and 436 MPa in a tissue level implant at a load direction of 0, 15, 30, 45, and 60°, respectively. For microgap formation between the implant and abutment interface, three to seven-micron gaps were observed in the bone level implant under a load at 45 and 60°. In contrast, a three-micron gap was observed in the tissue level implant under a load at only 60°. CONCLUSION. The mean stress of bone-level implant showed 2.2 times higher than that of tissue-level implant. When considering the loading point of occlusal surface and the direction of load, higher stress was noted when the vector was from the center of rotation in the implant prostheses.

Five-year investigation of a large orthodontic patient population at a dental hospital in South Korea

  • Piao, Yongxu;Kim, Sung-Jin;Yu, Hyung-Seog;Cha, Jung-Yul;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.46 no.3
    • /
    • pp.137-145
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the characteristics of orthodontic patients at Yonsei Dental Hospital from 2008 to 2012. Methods: We evaluated Angle's classification from molar relationships, classification of skeletal malocclusion from the A point-nasion-B point angle, facial asymmetry, and temporomandibular joint disorders (TMDs) from the records of 7,476 patients who received an orthodontic diagnosis. The orthognathic surgery rate, extraction rate, and extraction sites were determined from the records of 4,861 treated patients. Results: The patient number increased until 2010 and gradually decreased thereafter. Most patients were aged 19-39 years, with a gradual increase in patients aged ${\geq}40years$. Angle's Class I, Class II divisions 1 and 2, and Class III malocclusions were observed in 27.7%, 25.6%, 10.6%, and 36.1% patients, respectively, with a gradual decrease in the frequency of Class I malocclusion. The proportion of patients with skeletal Class I, Class II, and Class III malocclusions was 34.3%, 34.3%, and 31.4%, respectively, while the prevalence of facial asymmetry and TMDs was 11.0% and 24.9%, respectively. The orthognathic surgery rate was 18.5%, with 70% surgical patients exhibiting skeletal Class III malocclusion. The overall extraction rate among nonsurgical patients was 35.4%, and the maxillary and mandibular first premolars were the most commonly extracted teeth. Conclusions: The most noticeable changes over time included a decrease in the patient number after 2010, an increase in the average patient age, and a decrease in the frequency of Angle's Class I malocclusion. Our results suggest that periodic characterization is necessary to meet the changing demands of orthodontic patients.

Assessment of mechanical allodynia in healthy teeth adjacent and contralateral to endodontically diseased teeth: a clinical study

  • Vaishnavi Ratnakar Patankar;Ashish K Jain;Rahul D Rao;Prajakta R Rao
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.3
    • /
    • pp.31.1-31.11
    • /
    • 2024
  • Objectives: The present study investigated the prevalence of mechanical allodynia (MA) in healthy teeth adjacent and contralateral to endodontically diseased teeth. Materials and Methods: This cross-sectional study included 114 patients with symptomatic irreversible pulpitis and apical periodontitis in permanent mandibular first molars who possessed healthy teeth adjacent and contralateral to the endodontically diseased tooth. The mechanical sensitivity of the teeth was determined by percussion testing. The presence or absence of pain on percussion in the teeth adjacent and contralateral to the endodontically diseased tooth and the tooth distal to the contralateral symmetrical tooth was recorded according to coding criteria. The prevalence of MA was computed as a percentage, and binary logistic regression analysis was done. The Fisher exact test and Mann-Whitney U test were used for binary and ordinal data. Results: Age and sex did not influence the prevalence of MA. An increased prevalence of MA was found in patients with higher levels of spontaneous pain (p < 0.001). The prevalence of allodynia was 57% in teeth adjacent to endodontically diseased teeth and 10.5% in teeth contralateral to endodontically diseased teeth. In addition, on the ipsilateral side, there were more painful sensations distal to the diseased tooth than mesially. Conclusions: Despite being disease-free, teeth adjacent and contralateral to endodontically diseased teeth exhibited pain on percussion. There was a direct association between the severity of the patient's pain and the presence of MA.

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.

Assessment of inlay ceramic restorations manufactured using the hot-pressing method (열 가압 방식을 사용하여 제작된 인레이 세라믹 수복물의 적합도 평가)

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Park, Dong-In;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.9-16
    • /
    • 2020
  • Purpose: The purpose of this study was to compare the marginal and internal fit of lithium disilicate ceramic inlay produced by heat pressing that inlay pattern made by subtractive manufacturing and additive manufacturing method. Methods: A mandibular lower first molar that mesial occlusal cavity (MO cavity) die was prepared. After fabricating an epoxy resin model using a silicone impression material, epoxy resin die was scanned with a dental model scanner to design an MO cavity inlay. The designed STL pile was used to fabricate wax patterns and resin patterns, and then lithium disilicate ceramic inlays were fabricated using hot-press method. For the measurement of the marginal and internal gap of the lithium disilicate, silicone replica method was applied, and gap was measured through an optical microscope (x 80). Data were tested for significant differences using the Mann-Whitney Utest. Results: The marginal fit was 103.56±9.92㎛ in the MIL-IN group and 81.57±9.33㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). The internal fit was 120.99±17.52㎛ in the MIL-IN group and 99.18±6.65㎛ in the SLA-IN group, with a significant difference found between the two groups (p<0.05). Conclusion: It is clinically more appropriate to apply the additive manufacturing than subtractive manufacturing method in producing lithium disilicate inlay using CAD/CAM system.