• Title/Summary/Keyword: the law of parking lot

Search Result 15, Processing Time 0.026 seconds

An Analysis of Complex for a Parking Lot Expansion (주차장 확대를 위한 공동주택 단지특성 분석)

  • Ha, Na;Song, Nak-Hyun;Yoon, Ho-Bin;Lee, Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.1039-1042
    • /
    • 2007
  • The number of vehicle has been increased due to growth of economy. Consequently, the needs for parking area has been increasing. there is a serious problem in aged-apartments. It result from observing a parking lot law at that times. That is the reason why residents demand parking lot expansion. Parking lot addition is being studied on a lots different standpoint to solve the present parking lot condition. Parking lot expansion is limited by housing complex characteristics. This study analyzed the housing complex characteristics of aged-apartment. It is analyzed that the number of house holders, distance between buildings, and level of site for finding housing complex characteristics. The result are as follows. the complex lower than 300 households is about 35% in the Number of households. The buildings which has a moving distance from 41m to 50 is nearly 23%. Them the 멕스둣 house located on the flat is 82%. This study will become a reference data for the parking lot expansion.

  • PDF

A Study on Parking Problems and Improvement of Residential Development District - in the Case of Chil-gok 1 Residential Development District - (택지개발지구내 주차장의 문제점과 개선방안에 관한 연구 - 칠곡1택지개발지구를 사례로 -)

  • Hwang, Jin-Sung;Kim, Tae-Gap
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.2
    • /
    • pp.53-59
    • /
    • 2013
  • The purpose of this study is recognized the problems of parking and parking demand, supply and operation of the control etc. It is to provide an alternative for the overall parking problem. Parking problem occurs because there is not enough parking spaces. In order to solve the parking problem of Chil-gok 1 residential development district, this study propose making use of a road parking lot establishment and the school playground and the public facilities construction parking lot. But it is the methods which are short-term. A fundamental solution method is Levying garage option on car buyers. It is system to apply a law for establishing garages to all of vehicles.

Estimation of Parking Lot Planning and, Suggestion of Parking Planning Methods Considering Vehicle Types (차종을 고려한 주차 계획단위 산정 및 주차계획 방법 제시)

  • Kwon, Sung-Dae;Park, Je-Jin;Kim, Joong-Hyo;Ha, Tae-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6D
    • /
    • pp.755-764
    • /
    • 2011
  • At the present, planning and installation of parking space sections and lane width are implemented in accordance with the installation standard and parking lot structure by the enforcement regulations of the Parking Act. While large and RV (Recreational Vehicle) vehicles have increased in number recently, parking is complex with improper installation standards. It causes serious problems, including vehicle vandalism, increased civil complaints, travel inconveniences for parking lot users, management and maintenance issues for parking lots, and so forth. The study, therefore, determined that the practical and appropriate realignment of parking unit adjustment and lane width regulations are essential. The study conducted prior review on domestic parking sections and change cases of composition by vehicle types, including the component ratio of domestic and foreign vehicles, width of vehicle by types in order to examine the parking problems that account for a increasing social issues, and provided parking plan methods by types of vehicle, as well as reform and reaction plans for parking unit adjustment and lane width considering security and smooth traffic flow. After comparing and analyzing between estimated installation of parking space and lane width and internal and external cases, the study suggests the improvement that considers expenses and convenience of a driver. Also, it shows installation of parking space that considers traffic safety, improvement of lane width, and parking way depends on vehicle types. By providing estimation for parking planning and parking planning methods that secure safe and smooth traffic flow within a parking lot, the study will contribute to the development of improved alternatives for cost-effective traffic safety and set-up structure, including installation standards of parking lots.

A Study on the Improvement of the Method to Evaluate the Status of Parking Supply and Demand (주차장 수급실태 평가 방법의 개선에 관한 연구)

  • Shin, Hyoung O;Yoon, Jae Yong;Choi, Jin Seon;Lee, Eui Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.351-359
    • /
    • 2019
  • In order to improve the problem of parking which is getting worse day by day, the municipality carries out a survey on the actual situation of the parking lot supply and demand periodically according to the related law. However, in the existing evaluation method, the parking demand that occurs under the condition that the demand is suppressed by the parking supply and regulation due to the limit of the survey method is investigated. In addition, the analysis is conducted only for the present year, and prediction and analysis of future parking problems are limited. Therefore, we propose a method to evaluate the status of parking supply and demand, which is differentiated to improve the problem of the existing evaluation method. As a result, comparing the existing method with the improved method, it can be seen that the improved evaluation method can be useful for establishing the long-term parking policy for the improvement of parking problems.

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.

A Study on the Effective Method of Fire Extinguisher Maintenance In the Underground Parking Lot of the Apartment (아파트 지하주차장 소화기의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • The definition of an apartment is a building more than 5 stories high and which is the standard law. Currently, the number of apartments is increasing much faster than detached houses. Owning an apartment is a normal trend these days. However, the increasing number of apartments has been increasing the number of apartment fires which also has been making social problems. Therefore, this study was conducted for the fire extinguisher among other fire facilities because it is important for initial fire suppression. The research subject is on the fire extinguisher that is in the underground parking lot of 40 apartment complexes which are more than 10 stories. Survey and analysis were conducted for 80 fire extinguishers. There are two fire extinguishers for each apartment. The result of this study is that all installed fire extinguishers are ABC dry chemical type, 92% of them is 3.3kg and that meet the legal height(less than 1.5m). However, the condition such as appearance, inspection, manufactured year, appearance of signs, material of signs, size of signs, etc. was insufficiency. So improvement of law and system that are fire facility construction, maintenance implementation and additional designation of type approval about sign will be needed in my opinion.

Analysis of Soil Contamination with Depth in Non-sanitary Closed Waste Landfill (비위생 사용종료매립장의 심도별 토양오염도 분석)

  • Oh, Young-In;Kim, Kwan-Ho;Lee, Dong-Geon;Cho, Sook-Hee;Bak, Eun-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1217-1224
    • /
    • 2010
  • These days, the maintenance of closed waste landfill come to the fore social problem such as legal maintenance period, after closed maintenance deposits, stability evaluation guides and environmental survey for closed landfill management. Therefore the many non-sanitary closed waste landfill has been removed by selection and transfer to sanitary landfill and incineration. When the remove the non-sanitary landfill, the pollution level of bottom soil was investigated by related government law. In this case study, the soil contamination survey was performed to evaluate the pollution level of non-sanitary closed landfill bottom soil. Based on this study, the pollution level of studied non-sanitary landfill bottom soil was content with related government law for third area(factory, parking lot, gas station, road, railroad use etc.).

  • PDF

A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building (상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.

Levying Garage Option on Car Buyers (Jejusi Case Studies and the Way to Success) (제주시 차고지증명제 사례소개와 성공을 위한 방안 연구)

  • Hwang, Gyeong-Su
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.4
    • /
    • pp.91-100
    • /
    • 2009
  • The purpose of this study is to introduce the Levying Garage Option on Car Buyers which has become operative firstly in Korea, and to suggest the way to activate the system, hearing the view of Jeju residents with positive and negative function of parking. Levying Garage Option on Car Buyer is the system to apply a law for establishing garages to all of vehicles. Especially this is proposed to correct the disorder of Local street night parking, to improve the fine view of street, and to recover the original function of street to residents. To make this system successful there should be separate solutions at the densely built up area as a result of survey. This study conduct the Logistic Regression Analysis for and against the system. If the more residents approve the system, we should concern about the several solutions such as easing the distance between the garage and street, regulating, and special plan for an apartment house, etc. The suggestions are as follows. First, the policy needs to ease the distance between the garage and street gradually. Second, the Jeju government need to offer the residents the incentive such as reduce or exempt the tax and make them establish the private parking lot with supplying the low interest loan. Third, there should be connected with the project to break up the fences of their houses.

An Anaysis of current Facilities for the Physically Disabled in Hospital (지체장애인의 접근을 고려한 종합병원 장애인편의시설의 실태분석에 관한 연구)

  • Lee, Kyoo-Il;Ryu, Soo-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.1
    • /
    • pp.35-41
    • /
    • 2015
  • This study mostly concentrates on the ease of access to the hospital for the physically handicapped and investigated the condition of facilities for disabled of 59 hospitals in Seoul. For investigation, this research developed tool based on Korean disability law. An improvement plan which will deal with the safety and accessibility for the physically handicapped and for patients are as follows. 1) Safe passage should be designed continuously from entrance to the parking lot. 2) Obstacles on the safe passage should be removed and widen the pathways.