Browse > Article

Research about room air quality of department store underground parking lot  

Kim Ki-Tae (Dept. Environment health, Soonchunhyang University)
Yang Sung-Su (Dept. Environment health, Soonchunhyang University)
Son Bu-Soon (Dept. Environment health, Soonchunhyang University)
Jeon Young-Taek (Dept. Environment health, Soonchunhyang University)
Jang Bong-Ki (Dept. Environment health, Soonchunhyang University)
Lee Jong-Dae (Dept. Environment health, Soonchunhyang University)
Publication Information
Journal of environmental and Sanitary engineering / v.21, no.1, 2006 , pp. 44-51 More about this Journal
Abstract
This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.
Keywords
Air Quality; $O_3$; NOx;
Citations & Related Records
연도 인용수 순위
  • Reference
1 이현주, 정재열, 이종영, 송희봉, 홍성철 대구시 공공이용시설 지하주차장의 TSP, PM10 및 중금속의 농도. 한국환경위생학회지, 제26권 제2호
2 이승민, 문현준, 이정재, 손장열 : 아파트 지하주차장의 실내공기환경(IAQ)평가에 관한 연구. 대한건축학회학술발표논문집, 제15권 제1호, 1995
3 환경부 : 실내공기질 관리 기본계획, 2004
4 함흥돈, 김재민, 박병윤, 손장렬 : 전용 지하주차장의 실내공기환경실태에 관한 측정연구. 대한건축학회학술발표논문집, 제 15권 2호, 1995
5 이경희, 이윤규, 윤재옥, 문은미, 정재국 : 사무소건물의 실내공기 환경에 대한 실태조사 연구, 대한건축학회 논문집, 제 11권 12호, 1995
6 백성옥, 김윤신 : 도시지역 실내환경 유형별 공기질 특성 평가, 대기보전학회지, 제 14권 제4호, 1998
7 박병윤, 함영돈, 손장렬 : 지하주차장의 실내공기환경 특성에 관한 측정연구. 대한건축학회논문집, 제 13권 11호, 1997
8 함흥돈, 손장열, 박병윤, 김재민, 이병기 : 지하주차장의 난방기 실내공기환경 특 성, 대한건축학회학술발표논문집, 제16권 제1호 1996
9 송희봉, 권택규, 홍성희, 백성옥 : 대구시 대규모 지하주차장의 실내공기질 특성평가. 대기환경공학회, 제 20권 9호, 1998
10 박영석 : 서울지역 대기 중 오존 발생 특성에 관한 연구, 연세대학교 보건학 석사학위논문, 2000
11 공성용, 구현정 : 사업장 질소산화물 저감기술의 평가 및 비용분석, 한국환경정책평가연구원, 2002
12 손부순, 양원호, 전용택, 정순원 : 아산과 대구지역의 실내 ,외 $NO_{2}$ 농도와 관련 요인에 관한 연구, 대기환경학회 춘계학술대회논문집, 2005
13 김명곤, 한진석, 황동진, 최덕일 : 수도권 지역에서 고농도 오존사례에 관한 연구, 한국대기환경학회 학술대회논문집, 제 2권, 1995