• Title/Summary/Keyword: the joint angle

Search Result 1,431, Processing Time 0.031 seconds

Comparison of the Joint Position Sense at Knee Joint According to Surface Conditions (지지 면 조건에 따른 무릎관절의 관절 위치 재현능력 비교)

  • Hong, Young-Ju;Weon, Jong-Hyuck;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.90-96
    • /
    • 2007
  • The purpose of this study was to compare the joint position sense at the knee joint at 3 different surface conditions by using the active knee joint angle reproduction test in the standing position. Twenty healthy volunteers (10 males and 10 females) age 20~29 years were recruited for this study. The knee joint position senses were assessed at three different surface conditions: on the floor (stable condition), TOGU (soft condition), and seat fit (unstable condition) in a closed kinetic chain. Testing orders were selected randomly. The absolute angle error was defined as the absolute difference between target angles ($30^{\circ}{\sim}45^{\circ}$ knee flexion) and subject perceived angle of the knee flexion. One way ANOVA was used to compare the absolute angle of error among 3 different conditions. The Independent t-test was used to compare the absolute angle of error between male and female. The error angles were significantly different among surface conditions ($1.3^{\circ}{\pm}1.2^{\circ}$ for the floor, $2.1^{\circ}{\pm}0.9^{\circ}$ for the TOGU, and $4.4^{\circ}{\pm}1.8^{\circ}$ for the seat fit, p<.05). There was no significant difference in error angle between male and female. In conclusion, the joint position sense of the knee joint in the closed kinetic chain decreased at unstable surface conditions. The result of this study indicates that surface conditions should be considered when assessing and training the joint position sense of the knee joint in clinical setting.

  • PDF

The Effects Where the Stroke Shoes Which Use Functional Electric Stimulation Goes Mad to Walking of the Hemiplegia (기능적 전기자극 치료기를 이용한 중풍구두가 편마비 환자의 보행에 미치는 영향)

  • Kim, Jeong-Seon;Park, Ji-Whan
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Purpose: An objective analysis and observations were to be done on hemiplegia patients that are wearing a walking support device, Stroke shoes. Their improvements in walking pace, the reduction of distance between the two knee joint, the increase of curve angle of the knee joint and their steps and the reduction of ankle joint upon swing phase were analyzed using a 20 walking analyzer. Methods: An examination was carried out to see the patients' communication skill and independent walking and then let them walk with the Stroke shoes on to get results before and after wearing it. Simi Reality Motion Systems GmbH (Germany, 2007) was used to analyze the results regarding knee joint and ankle joint angle changes of sagitta plane and coronal plane, stepping distances, distances between the knees and walking pace. Results: 1. The articulation angle of ankle joint during swing phase decreased and knee joint has shown a statistically significant increase in such value(p<0.05). 2. Only knee joint showed a significant increase in articulation angle during heel strike(p<0.05). 3. Knee joint showed a significant increase in articulation angle during toe off(p<0.05). 4. The distance between the two knees as well as their foot steps significantly decreased compared with when Stroke shoes were not worn(p<0.05). 5. Stroke shoes with FES have shown positive effects on the patients in improving their walking styles overall. (p<0.05). Conclusion: There was an improvement in rotation walking pattern by a reduction in the distance between the knees after wearing Stroke shoes with FES. Plantar flexion reduced that occurred in ankle joint during walking and flexion angle increased in knee joint, both of which improved foot drop which was a major problem in hemiplegia patients. Also it is believed that the device will have some positive influences on knee joint stiffening paralysis to aid in improving inefficient walking phases.

  • PDF

Analysis of Lower Limb Joint Angle and Rotation Angle of Tennis Forehand Stroke by Stance Pattern (스탠스 유형에 따른 테니스 포핸드 스트로크의 하지관절각도와 회전각도 분석)

  • Kang, Young-Teak;Lee, Kyung-Soon;Seo, Kuk-Woong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.85-94
    • /
    • 2006
  • The purpose of this study was to analyze the kinematics variables of during forehand stroke by stance patterns. Eight high school tennis players were chosen for the study, who have never been injured for last six months, in Busan. They performed horizontal swing and vertical swing that it was done each five consecutive trial in the condition of square, open and semi-open stance. It was filmed by 6 video camera and used with 3-dimensional motion analyzer system. The following kinematic variables were analyzed in relation to angle of segment( shoulder, hip and knee joint). The conclusion were as follow: 1. The angle of hip joint represented at impact that horizontal swing was not significant difference by stance patterns but vertical swing was increased in open stance than square and semi-open stance. 2. The angle of both knee was not significant difference between all stance types and swing patterns. 3. The angle of shoulder, hip and knee joint rotation showed that open stance was increased than square and semi-open stance in all swing types and event.

The effects of grasp strength and brachioradialis thickness in elbow joint angle (팔굽관절 각도가 악력과 위팔노근 두께에 미치는 영향)

  • Park, Jung-A
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2073-2078
    • /
    • 2015
  • This study is investigated for angle of elbow joint influence on grasp strength, confirm change of grasp strength and brachioradialis thickness according to angle of elbow joint in standing. Thirty male and female university students, who participated with agreement in this study, using for electronic dynamometer and convertible ultrasound measure maximum grasp strength and brachioradialis thickness after elbow joint $0^{\circ}$, $90^{\circ}$, $135^{\circ}$ positioning in standing. In average grasp strength was strongest at elbow joint $0^{\circ}$, as the angle of elbow joint increased, was decreased grasp strength, no significant statistically(p<.05). In average brachioradialis thickness was lowest at elbow joint $0^{\circ}$, as the angle of elbow joint increased, was increased brachioradialis thickness, significant statistically(p<.05). These result may indicated that change of elbow joint angle not influence on grasp strength, but influence on brachioradialis thickness.

The Effects of Chronic Ankle Instability on Postural Control during Forward Jump Landing (전방 점프 착지 시 만성 발목 불안정성이 자세 조절에 미치는 영향)

  • Kim, Kew-wan;Jeon, Kyoungkyu;Park, Seokwoo;Ahn, Seji
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.1
    • /
    • pp.9-16
    • /
    • 2022
  • Objective: The purpose of this study was to investigate how the chronic ankle instability affects postural control during forward jump landing. Method: 20 women with chronic ankle instability (age: 21.7 ± 1.6 yrs, height: 162.1 ± 3.7 cm, weight: 52.2 ± 5.8 kg) and 20 healthy adult women (age: 21.8 ± 1.6 yrs, height: 161.9 ± 4.4 cm, weight: 52.9 ± 7.2 kg) participated in this study. For the forward jump participants were instructed to stand on two legs at a distance of 40% of their body height from the center of force plate. Participants were jump forward over a 15 cm hurdle to the force plate and land on their non-dominant or affected leg. Kinetic and kinematic data were obtained using 8 motion capture cameras and 1 force plates and joint angle, vertical ground reaction force and center of pressure. All statistical analyses were using SPSS 25.0 program. The differences in variables between the two groups were compared through an independent sample t-test, and the significance level was to p < .05. Results: In the hip and knee joint angle, the CAI group showed a smaller flexion angle than the control group, and the knee joint valgus angle was significantly larger. In the case of ankle joint, the CAI group showed a large inversion angle at all events. In the kinetic variables, the vGRF was significantly greater in the CAI group than control group at IC and mGRF. In COP Y, the CAI group showed a lateral shifted center of pressure. Conclusion: Our results indicated that chronic ankle instability decreases the flexion angle of the hip and knee joint, increases the valgus angle of the knee joint, and increases the inversion angle of the ankle joint during landing. In addition, an increase in the maximum vertical ground reaction force and a lateral shifted center of pressure were observed. This suggests that chronic ankle instability increases the risk of non-contact knee injury as well as the risk of lateral ankle sprain during forward jump landing.

The influence of the genu varum and the genu valgum on malalignment of the lower limb (내반슬, 외반슬의 부정정렬이 하지에 미치는 영향)

  • Moon, Sung-Gi
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.6 no.2
    • /
    • pp.31-38
    • /
    • 2000
  • The influence of the genu varum and the genu valgum in two groups of twenty adult man with deformation on hip joint, knee joint, ankle joint is as follows. 1. Each and all, the statistics that measure tibiofemorial angle indicated the group of the genu varum 168 1.42 and the group of the genu valgum 193 2.21, that was more larger or smaller than normal angle 183 of tibiofemorial. The measure Q-Angle(patellofemorial) indicates the group of the genu varum 9 1.5, the genu valgum 19 2.3, that was larger or smaller than normal angle 13. 2. It showed that range of motion hip joint adduction in the group of the genu varum was more larger than normal range of motion hip joint abduction in the group of the genu valgum was more larger than normal range of motion, hip joint internal rotation in the group of the genu valgum was more larger than normal range of motion, hip joint external rotation in the group of the genu varum was more larger than normal range of motion. 3. range of motion knee joint flexion was simillar to two groups of the genu varum and the genu valgum. On tibial tortion of the leg, the group of the genu varum indicated medial tibial tortion, and the genu valgum indicated lateral tibial tortion. 4. Each groups of the genu varum and the genu valgum in plantarflexion and dorsiflexion of ankle joint. With peak angle, the group of the genu varum showed toe-in that was more smaller than normal angle, and the group of the genu valgum showed toe-out that was more larger than normal angle.

  • PDF

Comparison of Isometric Knee Extension Torque-Angle Relationship between Taekwondo Athletes and Normal Adults (태권도 선수와 일반인의 등척성 무릎신전 토크-각도 관계 특성 비교 분석)

  • Jo, Gye-Hun;Oh, Jeong-Hoon;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.275-281
    • /
    • 2015
  • Objective : In order for Taekwondo athletes to perform destructive kicking performance, they are expected to have Taekwondo-specific muscle properties such as high muscle strength and power. The purpose of this study was to investigate the joint angle-dependent force-producing property of Taekwondo athletes' knee extensor muscles, which is one of the primary muscle groups involved in kicking performance. Method : Ten Taekwondo male athletes (age: $19.9{\pm}0.7yrs$, height: $180.6{\pm}6.2cm$, body mass: $75.9{\pm}8.9kg$, career: $9.2{\pm}2.9yrs$.) and 10 healthy male non-athletes (age: $26.3{\pm}2.6yrs$, height: $174.2{\pm}4.8cm$, body mass: $72.8{\pm}7.7kg$) participated in this study. Subjects performed maximum isometric knee extension at knee joint angles of $40^{\circ}$, $60^{\circ}$, $80^{\circ}$, and $100^{\circ}$ (the full knee extension was set to $0^{\circ}$) with the hip joint angles of $0^{\circ}$ and $80^{\circ}$ (the full extension was set to $0^{\circ}$). During the contractions, knee extension torque using an isokinetic dynamometer simultaneously with muscle activities of the rectus femoris (RF), and the vastus lateralis (VL) and vastus medialis (VM) using surface electromyography were recorded. Based on the torque values at systematically different knee-hip joint angles, the joint torque-angle relationships were established and then the optimal joint angle for the knee extensor was estimated. Results : The results of this study showed that the isometric knee extension torque values were greater for the Taekwondo athletes compared with the non-athlete group at all hip-knee joint angle combinations (p<.05). When the hip joint was set at $80^{\circ}$, the peak isometric torque was greater for the Taekwondo athletes compared with the non-athlete group ($313.61{\pm}36.79Nm$ and $221.43{\pm}35.92Nm$, respectively; p<.05) but the estimated optimum knee joint angles were similar ($62.33{\pm}5.71^{\circ}$ and $62.30{\pm}4.67^{\circ}$ for the Taekwondo athletes and non-athlete group, respectively). When the hip joint was set at $0^{\circ}$, the peak isometric torque was greater for the Taekwondo athletes compared with the non-athlete group ($296.29{\pm}45.13Nm$ and $199.58{\pm}25.23Nm$, respectively; p<.05) and the estimated optimum knee joint angle was larger for the Taekwondo athletes compared with the non-athlete group ($78.47{\pm}5.14^{\circ}$ and $67.54{\pm}5.77^{\circ}$, respectively; p<.05). Conclusion : The results of this study suggests that, compared with non-athletes, Taekwondo athletes have stronger knee extensor strength at all hip-knee joint angle combinations as well as longer optimum muscle length, which might be optimized for the event-specific required performance through prolonged training period.

Characteristics of Knee Joint Flexion Angle and Foot Pressure according Slope Climbing (경사로 오르기 동안 슬관절 굴곡각도와 족저압의 특성 비교)

  • Oh, Tae-Young;Song, Hyeon-Ju;Lee, Seul-Gi;Jung, Ye-Ji;Lim, Jong-Su
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.268-276
    • /
    • 2010
  • This study was to investigate the knee joint flexion angle and the foot pressure during climbing with different slope. The 24 healthy subjects were participated. And foot pressure was investigated using Parotec system. The knee joint flexion angle were filmed to using a video camera on each slope($0^{\circ},\;3^{\circ},\;6{\circ},\;9^{\circ}$). And knee joint angle was investigated by Dartfish. The data were analyzed ANOVAs. In conclusion, there was significantly different that knee joint flexion angle related on each slope angle. In foot pressure, there was significantly different in lateral heel area(1 cell), medial midfoot area(9 cell), medial forefoot area(15, 16 cell) of left foot, and in lateral heel area(3 cell) of right foot. There was significantly different of foot pressure in lateral and medial heel when knee joint flexion angle is between $10^{\circ}$ and $20^{\circ}$. There was change of gait cycle according to walking slop angle increasing, and the initial contact phase was shorter, the foot pressure in lateral heel was lower.

The Effects of Ankle Joint Angle on Knee Extensor Electromyographic Activity (발목관절의 각도가 무릎관절 폄근의 근활성도에 미치는 영향)

  • Yeo, Sang-Seok;Kwon, Jung-Won;Kim, Chung-Sun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 2009
  • Purpose : The purpose of this study was to find the effect of ankle joint angle on knee extensor electromyographic activity following knee extension exercise. Methods : Ten male university students participated in the study. The subjects performed isometric maximal voluntary knee extensor contractions (MVC) and knee extensor EMG activity measured in with three different ankle joint angle. The EMG activity of rectus femoris(RF), vastus medialis(VM), vastus lateralis(VL) were measured using surface electromyography. Results : EMG activity of vastus lateralis following the change of ankle joint angle was shown statistically significant difference. Conclusion : Ankle plantar flexion position increase EMG activity of vastus lateralis during knee extension exercise.

  • PDF

A Study on Load Transfer Efficiency of Skewed Transverse Joint of Concrete Pavement by the Fatigue Test (피로실험에 의한 콘크리트 포장체 경사가로줄눈부의 하중전달율에 관한 연구)

  • Hwang, Seung-Eui;Bae, Ju-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.3
    • /
    • pp.203-211
    • /
    • 2001
  • This paper presents load transfer efficiency of skewed transverse joint of jointed concrete pavement with the fatigue model test. A 1/12 scale model was used to satisfy the geometry, loading, material similitude, which are variables to the skew angel of transverse joint. As the test results by fatigue load 700kgf applied, the deflection and stress of transverse joint were decreased as to increasing of skew angle of transverse joint. In addition, load transfer efficiency of transverse joint with skew angle is better than the load transfer efficiency of transverse joint without skew angle.

  • PDF