• 제목/요약/키워드: the direction of shear force

검색결과 151건 처리시간 0.026초

클린룸 내 롤러 컨베이어 운송장치 주위의 유동해석 (Flow Analysis around the Roller Conveyor in a Clean Room)

  • 전현주;박찬우;임익태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1507-1512
    • /
    • 2009
  • Flow field in a roller conveyor system, induced from the movement of a cassette in which glasses for flat panel display are loaded, is numerically studied in this paper. Contamination on the glass surface by dust particles produced from mechanical friction between roller and cassette is predicted from the analysis results of flow fields. Results show that a large swirl flow is formed under the moving cassette with constant speed. This swirl flow is confined only under the cassette because two main streams from the backward and the fan filter unit on the top ceiling are sufficiently strong. Therefore, it can be said that possibility of the contamination by the particles originated from the friction is relatively low. It is also revealed that flow direction between glass plates is changed according to the speed of the cassette movement due to the shear force of glass plates.

  • PDF

지하벽체의 최대부재력 산정을 위한 차트의 개발 (Development of Design Charts to Estimate Member Forces on Basement Wall)

  • 김영찬;김주범
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.104-110
    • /
    • 2012
  • It is a common practice to design basement walls acting as a one-way slab or plate with idealized boundary conditions, resulting in potentially inefficient design. The walls are often supported by buttress columns and side walls in the vertical direction, thereby acting as a two-way slab. In this study, structural behavior of single-story, three-span basement wall subjected to lateral soil pressure was investigated. Three dimensional finite element analyses were conducted to determine the force distribution on the wall. Based on the numerical studies, a regression analysis was carried out to determine the design values of moments in vertical and horizontal directions as well as shear forces on the wall and design charts are developed. The proposed design method with accompanying design charts would enable practicing engineers to estimate member forces on the wall for preliminary design purpose without resorting to finite element analysis. Numerical examples demonstrated the applicability of the proposed method.

무차원 동영향 함수를 이용한 자유단 경계를 가진 임의 형상 평판의 진동해석 : 직선 및 곡선 경계가 혼합된 경우 (Free Vibration Analysis of Arbitrarily Shaped Plates with Free Edges Using Non-dimensional Dynamic Influence Functions: the case that straight and curved boundaries are mixed)

  • 최장훈;강상욱
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.534-537
    • /
    • 2005
  • Free Vibration Analysis using Non-dimensional Dynamic Influence Function (NDIF) is extended to arbitrarily shaped plates including polygonal plates. Since the corners of polygonal plates have indefinite normal directions and additional boundary conditions related to a twisting moment at a corner along with moment and shear force zero conditions, it is not easy to apply the NDIF method to polygonal plates wi th the free boundary condition. Moreover, owing to the fact that the local polar coordinate system, which has been introduced for free plates with smoothly varying edges, cannot be employed for the straight edges of the polygonal plates, a new coordinate system is required for the polygonal plates. These problems are solved by developing the new method of modifying a corner into a circular arc and setting the normal direction at the corner to an average value of normal direct ions of two edges adjacent to the corner. Some case studies for plates with various shapes show that the proposed method gives credible natural frequencies and mode shapes for various polygons that agree well with those by an exact method or FEM (ANSYS).

  • PDF

쿼드로터형 무인비행체의 후류 특성에 관한 실험적 연구 (An Experimental Study on the Wake Characteristics of a Quadrotor UAV)

  • 이승철;채석봉;김주하
    • 한국가시화정보학회지
    • /
    • 제16권1호
    • /
    • pp.30-36
    • /
    • 2018
  • In the present study, we investigate the flow characteristics of a quadrotor UAV in a hovering mode by measuring multiple two-dimensional velocity fields in the wake. The experiment is conducted at Re = 24,000 in a chamber large enough to neglect the ground effect, where Re is the Reynolds number based on the rotor chord length and the rotor tip speed. The rotational speed of the rotor is determined by an optical tachometer so that the lift force can be balanced with the weight of the UAV. The velocity field measured on the center plane of the rotor shows that the vortices are shedding from the tip of the rotor, inducing large fluctuations in the streamwise velocity along the wake shear layer. The strength of the rotor-tip vortex shedding is asymmetric with respect to the rotor axis due to the interaction between the rotor and the wake centerline of each rotor is inclined to the center of the UAV due to the pressure difference caused by the induced velocity. The wake from each rotor moves closer to each other while traveling in the streamwise direction, and then is merged together inducing large fluctuations in the transverse velocity. Due to the wake merging, on the center plane of the UAV, the velocity increases in the streamwise direction showing two-peak structure in the streamwise velocity contours.

Seismic performance of a fiber-reinforced plastic cable-stayed bridge

  • Hodhod, Osama A.;Khalifa, Magdi A.
    • Structural Engineering and Mechanics
    • /
    • 제5권4호
    • /
    • pp.399-414
    • /
    • 1997
  • This paper presents an investigation into the seismic response characteristics of a proposed ligh-weight pedestrian cable-stayed bridge made entirely from Glass Fiber Reinforced Plastics(GFRP). The study employs three dimensional finite element models to study and compare the dynamic characteristics and the seismic response of the GFRP bridge to a conventional Steel-Concrete (SC) cable-stayed bridge alternative. The two bridges were subjected to three synthetic earthquakes that differ in the frequency content characteristics. The performance of the GFRP bridge was compared to that of the SC bridge by normalizing the live load and the seismic internal forces with respect to the dead load internal forces. The normalized seismically induced internal forces were compared to the normalized live load internal forces for each design alternative. The study shows that the design alternatives have different dynamic characteristics. The light GFRP alternative has more flexible deck motion in the lateral direction than the heavier SC alternative. While the SC alternative has more vertical deck modes than the GFRP alternative, it has less lateral deck modes than the GFRP alternative in the studied frequency range. The GFRP towers are more flexible in the lateral direction than the SC towers. The GFRP bridge tower attracted less normalized base shear force than the SC bridge towers. However, earthquakes, with peak acceleration of only 0.1 g, and with a variety of frequency content could induce high enough seismic internal forces at the tower bases of the GFRP cable-stayed bridge to govern the structural design of such bridge. Careful seismic analysis, design, and detailing of the tower connections are required to achieve satisfactory seismic performance of GFRP long span bridges.

저층부에 약층과 비틀림 비정형성을 가진 고층 비정형 RC벽식 구조물의 지진응답 (Seismic Response of a High-Rise RC Bearing-Wall Structure with Irregularities of Weak Story and Torsion at Bottom Stories)

  • 이한선;고동우
    • 한국지진공학회논문집
    • /
    • 제7권6호
    • /
    • pp.81-91
    • /
    • 2003
  • 최근 우리나라의 대도시에서는 주거와 상업기능을 동시에 갖는 복합용도의 건축물이 많이 건설되고 있는데, 이러한 건물은 대부분 하부골조에서 연층, 약층 또는 비틀림 비정형을 띠게 된다. 본 논문의 목적은 이러한 건물의 지진응답을 실험을 통해 관찰하는 것으로서 1:12 축소모델의 진동대 실험을 통해 다음과 같은 결론에 이르렀다. 1) 구조물의 불확실성으로 인한 우발비틀림을 예측하는 것은 정적해석에 의한 방법보다 동적해석에 의한 방법이 더 타당하였다. 2) 횡운동과 비틀림운동이 연관되어 있을 때, 전도모멘트는 지진방향 뿐만 아니라 지진방향에 수직인 방향으로도 상당부분 작용하였으며, 일반적인 해석프로그램에서 수행하는 모드해석법으로는 이와 같은 거동을 예측하기에 부적절하였다. 3) 모드형상과 BST 다이아그램을 통해 대상구조물과 같은 건물의 주요 진동모드와 파괴양상을 쉽게 예측할 수 있었다.

지진하중의 특성과 이력모델에 따른 저층 표준학교건물의 비탄성 지진거동 (Inelastic Seismic Behavior of Low-story Standard School Buildings according to Characteristics of Earthquake Loads and Hysteresis Models)

  • 김진상;윤태호
    • 한국산학기술학회논문지
    • /
    • 제13권9호
    • /
    • pp.4294-4301
    • /
    • 2012
  • 본 연구는 내진설계 되지 않은 학교시설물 중 다수를 차지하는 1980년도 표준설계 도면(건설부 공고 제130호, 1980년 10월 28일)에 의하여 건설된 국내에 현존하는 4층 모멘트 연성골조의 학교건물을 대상으로 이력모델의 특성과 지진파의 특성에 따라 표준학교건물의 비탄성지진거동을 분석하고자 한다. El-centro지진은 주파수 성분과 강진지속시간의 특성에 의하여 표준학교건물의 단변방향 층전단력, 층간변위비, 층변위 응답에 매우 큰 영향을 미치며 특히 수정다케다모델 선택시 응답의 차이가 매우 크게 나타남을 알 수 있다. 층전단력의 경우 최대 46%, 층간변위비의 경우 최대 70%, 층변위의 경우 최대 59%의 편차를 보인다. Santa Monica지진은 장변방향의 응답에서 이력모델별 편차가 더 크게 나타났으며, 층전단력은 최대 59%, 층간변위비는 최대 65%, 층변위는 최대 50%의 편차를 보였다. 이는 장변방향의 고유주기가 단변방향에 비하여 크기 때문에 1초이상의 주기성분이 많은 Santa Monica지진의 특성에 의한 것으로 판단된다. Taft지진은 이력모델에 따른 층간변위비와 층변위 응답의 편차가 가장 적은 것으로 나타났으며, 층간변위비는 최대 15%, 층변위는 최대 5%의 편차를 보여 변위응답에 있어서 이력모델에 가장 의존도가 적은 결과를 얻을 수 있을 것으로 판단 된다.

볼트 구멍 크기에 따른 TS 고력볼트 접합부 거동 평가 (Evaluation on the Behavior of Slip Critical Joints with TS High Strength Bolts Subjected to a Size of Bolt Holes)

  • 이현주;김강석;나환선;이강민;김현철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.136-143
    • /
    • 2011
  • 고력볼트의 현장 조립시 볼트 구멍 간의 불일치로 인하여 볼트 구멍을 확장하는 경우가 빈번하게 발생하고 있으며, 이를 위해서 외국 기준에서는 볼트 구멍 크기, 형태, 하중 방향에 따라 미끄럼하중에 대한 규정을 따로 두고 있다. 그러나 우리나라의 경우 과대구멍에 대한 시방규정이나 이에 대한 접합부 특성에 관한 연구는 미흡한 실정이다. 따라서, 접합부재 표면처리와 볼트구멍 크기의 변화가 접합부 내력에 어떠한 영향을 미치는 지를 실험을 통해 정량적으로 평가할 필요가 있다. 본 연구에서는 볼트 구멍 크기 및 형태에 따른 접합부의 미끄럼하중의 변화와 체결 후, 장기축력이완의 경향을 분석하기 위하여 160시간 및 800시간 동안 고력볼트의 축력의 변화를 측정하였다. 본 실험대상 고력볼트로 KS B 2819에 규정된 TS(Torque Shear)형 고력볼트를 사용하였다. 표준 볼트구멍 대비 그 외 볼트구멍의 미끄럼하중의 변화는 10% 미만으로 나타났으며, 장기축력이완은 직경 2.5배의 슬롯구멍에서, 2.66%로 가장 높게 나타났다.

편심코어를 가지는 저층 철근콘크리트 필로티 건물의 내진성능 (Seismic Performance of Low-rise Piloti RC Buildings with Eccentric Core)

  • 김성용;김경남;윤태호
    • 한국산학기술학회논문지
    • /
    • 제21권10호
    • /
    • pp.490-498
    • /
    • 2020
  • 본 논문에서는 편심코아를 가지는 저층 필로티 건물의 내진거동을 해석하고 결과를 분석하였다. 본 논문에서는 저층 필로티 건물의 시공사례 중 KBC2005기준에 준하여 설계된 편심코어를 가지는 건물들의 설계자료를 수집하여, 대표적인 편심 필로티 건물을 프로토타입으로 선정하여 KDS41기준에 준하여 내진거동을 해석하고 결과를 분석하였다. 연구결과 편심코어를 가지는 필로티 건물의 경우 X방향은 소성거동, Y방향은 탄성거동을 하는 것으로 평가 되었다. 연구대상 건물의 층간 변위를 확인한 결과 최대변위 δ=67.51mm로 코어가 평면 중심에 위치하는 경우보다 층간 변위량이 더 큰 것으로 평가 되었다. 해석결과에서 층간 변위 비율은 법적 규준 이내인 것으로 평가되었다. 또한 변위 비율은 1층 필로티 구간이 2~4층 부분보다 확연히 높은 걸로 평가 되었으며, 저층 필로티 구조물의 경우 1층 라멘조 부분이 횡력에 취약한 것으로 평가되었다. 편심코어로 인하여 구조물 전체의 강성중심이 질량중심과 이격되어 있어 코어 반대쪽의 필로티 기둥에서 항복과 소성힌지 발생이 시작되므로 내진설계와 내진보강시 이에 대한 고려가 필요하다. 따라서, 편심코어를 가지는 저층 필로티 건물의 내진설계 및 내진보강시 필로티 구조의 횡변위 감소와 횡력저항능력을 보강할 필요가 있다.

터널근접시공에 의한 기 존재하는 인접말뚝의 거동에 지반보강이 미치는 영향에 대한 연구 (A study on the effects of ground reinforcement on the behaviour of pre-existing piles affected by adjacent tunnelling)

  • 전영진;김성희;김정섭;이철주
    • 한국터널지하공간학회 논문집
    • /
    • 제19권3호
    • /
    • pp.389-407
    • /
    • 2017
  • 본 연구는 단독말뚝 또는 군말뚝 형태의 기초 하부를 터널이 근접통과할 경우 말뚝의 거동을 파악하기위해 3차원 유한요소해석을 수행하였다. 이때 터널과 말뚝기초 사이의 지반보강 조건별로 수치해석을 수행하여 결과를 분석하였다. 수치해석에서는 터널굴착으로 인해 유발된 말뚝침하, 축력, 전단응력 및 터널 주변지반의 전체변위를 고찰하였다. 단독말뚝의 두부침하는 지반보강의 범위가 가장 넓은 경우 지반보강을 고려하지 않은 말뚝에 비해 약 16% 감소하며, 말뚝의 최대 축력 또한 지반보강을 고려하지 않은 말뚝에 비해 약 30% 감소하는 것으로 분석되었다. 터널굴착에 따른 말뚝의 거동은 지반보강길이 (종방향 보강)보다는 보강각도(횡방향 보강)에 대해 더 크게 영향을 받는 것으로 분석되었다. 한편 오직 기초판 보강만을 실시한 군말뚝의 경우 선단부근 지반의 변위는 보강을 고려하지 않은 조건의 지반 변위와 비슷하게 나타났다. 이에 비해 말뚝두부에서는 기초판이 말뚝을 크게 구속하여 타 조건 말뚝의 경우에 비해 말뚝상부에서 축력이 약 2.5배 증가하는 것으로 분석되었다. 본 연구를 통해 보강조건에 따른 단독말뚝 및 군말뚝의 거동에 영향을 미치는 주요인자를 심도 있게 고찰하였다.