• 제목/요약/키워드: the bio current

검색결과 770건 처리시간 0.027초

Quercetin Inhibits the 5-Hydroxytryptamine Type 3 Receptor-mediated Ion Current by Interacting with Pre-Transmembrane Domain I

  • Lee, Byung-Hwan;Jung, Sang-Min;Lee, Jun-Ho;Kim, Jong-Hoon;Yoon, In-Soo;Lee, Joon-Hee;Choi, Sun-Hye;Lee, Sang-Mok;Chang, Choon-Gon;Kim, Hyung-Chun;Han, YeSun;Paik, Hyun-Dong;Kim, Yangmee;Nah, Seung-Yeol
    • Molecules and Cells
    • /
    • 제20권1호
    • /
    • pp.69-73
    • /
    • 2005
  • The flavonoid, quercetin, is a low molecular weight substance found in apple, tomato and other fruit. Besides its antioxidative effect, quercetin, like other flavonoids, has a wide range of neuropharmacological actions including analgesia, and motility, sleep, anticonvulsant, sedative and anxiolytic effects. In the present study, we investigated its effect on mouse 5-hydroxytryptamine type 3 ($5-HT_{3A}$) receptor channel activity, which is involved in pain transmission, analgesia, vomiting, and mood disorders. The $5-HT_{3A}$ receptor was expressed in Xenopus oocytes, and the current was measured with the two-electrode voltage clamp technique. In oocytes injected with $5-HT_{3A}$ receptor cRNA, quercetin inhibited the 5-HT-induced inward peak current ($I_{5-HT}$) with an $IC_{50}$ of $64.7{\pm}2.2{\mu}M$. Inhibition was competitive and voltage-independent. Point mutations of pre-transmembrane domain 1 (pre-TM1) such as R222T and R222A, but not R222D, R222E and R222K, abolished inhibition, indicating that quercetin interacts with the pre-TM1 of the $5-HT_{3A}$ receptor.

Evaluation of Images Depending on an Attenuation Correction in a Brain PET/CT Scan

  • Choi, Eun-Jin;Jeong, Mon-Taeg;Dong, Kyung-Rae;Kwak, Jong-Gil;Choi, Ji-Won;Ryu, Jae-Kwang
    • 방사선산업학회지
    • /
    • 제12권4호
    • /
    • pp.267-276
    • /
    • 2018
  • A Hoffman 3D Brain Phantom was used to evaluate two PET/CT scanners, BIO_40 and D_690, according to the radiation dose of CT (low, medium and high) at a fixed kilo-voltage-peak (kVp) with the tube current(mA) varied in 17~20 stages(Bio_40 PET/CT scanner: the tube voltage was fixed to 120 kVp, the effective tube current(mAs) was increased from 33 mAs to 190 mAs in 10 mAs increments, D_690 PET/CT scanner: the tube voltage was fixed to 140 kVp, tube current(mA) was increased from 10 mAs to 200 mAs in 10 mAs increments). After obtaining the PET image, an attenuation correction was conducted based on the attenuation map, which led to an analysis of the difference in the image. First, the ratio of white to gray matter for each scanner was examined by comparing the coefficient of variation (CV) depending on the average ratio. In addition, a blind test was carried out to evaluate the image. According to the study results, the BIO_40 and D_690 scanners showed a <1% change in CV value due to the tube current conversion. The change in the coefficients of white and gray matter showed that the Z value was negative for both scanners, indicating that the coefficient of gray matter was higher than that of white matter. Moreover, no difference was observed when the images were compared in a blind test.

Multi-frequency 자극 방식을 이용한 생체 전기 임피던스 측정 시스템 설계 및 경혈의 전기적 특이성에 대한 고찰 (Development of Multi-Frequency Impedance Measurement System for Acupuncture Points and Preliminary Report of Measurement Results)

  • 김수병;이나라;이승욱;최준영;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권1호
    • /
    • pp.71-81
    • /
    • 2012
  • Objectives : The purpose of this paper was to suggest new diagnostic method that was to supersede the estimation of electrical properties at acupoints. Thus, we developed the multi- frequencies bioelectrical impedance measurement system so as to analyze the state of bio-ions in body fluid as body compositions, not skin impedance at acupoint. Methods : At low frequency, the current does not penetrate the cell membrane and at high frequency, the current passes through both intracellular and extracellular fluid because of the decreas of cell membrane impedance. To confirm the reflection of composition in extracellular fluid or intracellular fluid of segment such as acupoint, the system was developed to detect the acupoint potential between adjacent two points in the area of LU3, LU4 and LU9 using 5,50 and 200KHz. Results : The detected acupoint potential has been decreased according to elevation of frequency. As a result of correlation of left/right identical acupoint, we observed a high correlation of three types of acupoint potential at multi-frequencies. Moreover, we observed the low correlation at 5KHz, and that was a significant factor to be considered as unbalanced relationship of identical acupoints. Conclusions : On the basis of meridian theoretical point of view, we may infer the acupoint's physiological composition using the multi-frequencies bioelectrical impedance measurement system.

A Low-noise Multichannel Magnetocardiogram System for the Diagnosis of Heart Electric Activity

  • Lee, Yong-Ho;Kim, Ki-Woong;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, In-Seon;Park, Yong-Ki
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권4호
    • /
    • pp.154-163
    • /
    • 2006
  • A 64-channel magnetocardiogram (MCG) system using low-noise superconducting quantum interference device (SQUID) planar gradiometers was developed for the measurements of cardiac magnetic fields generated by the heart electric activity. Owing to high flux-to-voltage transfers of double relaxation oscillation SQUID (DROS) sensors, the flux-locked loop electronics for SQUID operation could be made simpler than that of conventional DC SQUIDs, and the SQUID control was done automatically through a fiber-optic cable. The pickup coils are first-order planar gradiometers with a baseline of 4 em. The insert has 64 planar gradiometers as the sensing channels and were arranged to measure MCG field components tangential to the chest surface. When the 64-channel insert was in operation everyday, the average boil-off rate of the dewar was 3.6 Lid. The noise spectrum of the SQUID planar gradiometer system was about 5 fT$_{rms}$/$\checkmark$Hz at 100 Hz, operated inside a moderately shielded room. The MCG measurements were done at a sampling rate of 500 Hz or 1 kHz, and realtime display of MCG traces and heart rate were displayed. After the acquisition, magnetic field mapping and current mapping could be done. From the magnetic and current information, parameters for the diagnosis of myocardial ischemia were evaluated to be compared with other diagnostic methods.

Electrospun Poly(Ether Sulfone) Membranes Impregnated with Nafion for High-Temperature Polymer Electrolyte Membrane Fuel Cells

  • Lee, Hong Yeon;Hwang, Hyung Kwon;Lee, Jin Goo;Jeon, Yukwon;Park, Dae-Hwan;Kim, Jong Hak;Shul, Yong-Gun
    • 전기화학회지
    • /
    • 제19권1호
    • /
    • pp.9-13
    • /
    • 2016
  • Electrospun poly(ether sulfone) (PES) membrane impregnated with Nafion (PES-N) have been developed for high-temperature polymer-electrolyte membrane fuel cell (HT-PEMFC). The PES-N obtains highly thermal stability up to $430^{\circ}C$, which is higher than that of the commercial Nafion 212. The PES-N membrane shows a good proton conductivity of about $10^{-2}S\;cm^{-1}$ in a temperature range from $75^{\circ}C$ to $120^{\circ}C$. The membrane-electrode assembly (MEA) with the PES-N membrane exhibits a current density of $1.697A\;cm^{-2}$ at $75^{\circ}C$, and $0.813A\;cm^{-2}$ at $110^{\circ}C$ when the applied voltage is 0.6 V, whereas the MEA with the Nafion 212 membrane shows the current density of $0.647Acm^{-2}$ at $110^{\circ}C$. The results suggest that the PES-N can be a good candidate for a polymer electrolyte membrane of the HT-PEMFC.

Current Challenges in Bacterial Transcriptomics

  • Cho, Suhyung;Cho, Yoobok;Lee, Sooin;Kim, Jayoung;Yum, Hyeji;Kim, Sun Chang;Cho, Byung-Kwan
    • Genomics & Informatics
    • /
    • 제11권2호
    • /
    • pp.76-82
    • /
    • 2013
  • Over the past decade or so, dramatic developments in our ability to experimentally determine the content and function of genomes have taken place. In particular, next-generation sequencing technologies are now inspiring a new understanding of bacterial transcriptomes on a global scale. In bacterial cells, whole-transcriptome studies have not received attention, owing to the general view that bacterial genomes are simple. However, several recent RNA sequencing results are revealing unexpected levels of complexity in bacterial transcriptomes, indicating that the transcribed regions of genomes are much larger and complex than previously anticipated. In particular, these data show a wide array of small RNAs, antisense RNAs, and alternative transcripts. Here, we review how current transcriptomics are now revolutionizing our understanding of the complexity and regulation of bacterial transcriptomes.

국내외 바이오모니터링 프로그램 및 생체시료 활용 현황 (Comprehensive Review of Domestic and Foreign Biomonitoring Programs and Current Status of Bio-sample Application)

  • 김다해;김성균;이승호;최윤형;김진희
    • 한국환경보건학회지
    • /
    • 제47권3호
    • /
    • pp.205-226
    • /
    • 2021
  • Objectives: Biomonitoring programs have been widely implemented in the field of environmental health, both in Korea and worldwide. Recently, it has been suggested that the storage, management, and utilization of biosamples collected from biomonitoring programs should be organized based on a biobank system. Therefore, we attempted to review the current status of representative biomonitoring programs and biobank systems that have been implemented in Korea and in other countries. Methods: We searched for bio-samples collected in domestic and foreign biomonitoring programs and their applications. For this, we referred to research papers, homepages hosted by biomonitoring programs, and project reports. We also checked information for biobanks related with biomonitoring programs, including the operating systems, facilities, technologies, and regulations of biobanks. Results: We summarized six domestic and 32 foreign biomonitoring programs. These biomonitoring programs collected bio-samples to determine the relationship between environmental chemicals and diseases. Domestically, bio-samples from KoNEHS, KorSEP, MOCEH, KoCHENS, and KorEHS-C were stored at -80℃ in a deep freezer at the National Institute of Environmental Research, while KNHANES samples were stored at Korea Biobank, which has a stabilized biobanking system with a well-established database. Nine foreign biomonitoring programs (JECS, China-NHBP, CKB, CHMS, NHANES, GerES, Germaan ESB, MoBa, and UK Biobank) were ongoing for large populations. Among them, CKB, GermanESB, and UK biobank have been maintained for at least 10 years with their own biomonitoring programs as well as advanced systems for the safe storage of bio-samples. Conclusion: Currently on-going biobanks have devoted considerable efforts to managing bio-samples for public purposes. The preceding domestic and foreign biomonitoring programs and biobanks will be great references for constructing biobank facilities and systems for environmental public health in Korea in the future.