• Title/Summary/Keyword: the Medical Examiner System

Search Result 13, Processing Time 0.029 seconds

Improve the Administrative Death Investigation System (행정검시제도 개선방안)

  • Kim, Heon-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.2
    • /
    • pp.276-283
    • /
    • 2012
  • Current Administrative Death investigation system is have many problems. Almost local governor don't exercise about administrative death investigation authority. Thus, prosecutors have to many decisions about judicial death investigation authority. Consequently, these vicious cycle is repeated. There is not clear regulations about scope for judicial death investigation. Discussed in this paper improve the Administrative Death investigation system are as follows : First, the uniform act of death investigation is have to legislated. Second, the scope for death investigation is clearly legalized. Medical examiner is must administrative death investigation according to the law. Also prosecutor can order to judicial autopsy to medic examiner. Third, Administrative Death investigation rules should be clarified. Introduce a Medical Examiner System Korean Administrative Death Investigation system centered on prosecutor and judicature who are not a specialist in pathology or forensic medicine. Lacking in professional understanding cause less accuracy of Administrative Death Investigation. To overcome limitations and problems of our Administrative Death Investigation system is suggested to introduce a Medical Examiner system.

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.

The role of Forensic Nurse in the situation of Sexual Assault (성폭력 발생시 법의간호사의 역할)

  • Youk, Gi-Young;Kwak, Jyung-Sik
    • Journal of forensic and investigative science
    • /
    • v.1 no.1
    • /
    • pp.31-44
    • /
    • 2006
  • The importance regarding the notion of immediate medical treatment and nursing for the victims of sexual crimes is not widely recognized yet in Korea. Throughout this research is focused on the nursing systems and the system of foreign countries in reference to sexual crime victims, and the conclusion is as follows. In Korea, there are currently no educational or medical institutes for the medical handling for the victims of sexual crimes, and the role of nurses in the medical institutes is insufficient. In addition, the basis for the standard of operation regarding the initial response, evidence collection, pursuit of systematical evidence and data is not established even in the sexual assault counseling/advocacy center. Therefore, it is necessary to foster the sexual assault nurse examiner for the sexual crime victims, and to develop adequate training programs based on the present situation in Korea. Though the cooperation among government, medical institutes, and social movement groups, it is essential to initiate effective and publicly-trusted specialized training programs for forensic nurses who will be fully charged with the treatment of sexual crime victims. By introducing the sexual assault nurse examiner system, it can be possible to develop advanced treatment for the child or adolescent victims of sex crimes.

  • PDF

The Outcomes and Tasks of Act on Medical Dispute Mediation (의료분쟁조정법 시행에 따른 성과와 과제)

  • Hyun, Doo-Yoon
    • The Korean Society of Law and Medicine
    • /
    • v.14 no.1
    • /
    • pp.117-144
    • /
    • 2013
  • After several bills for the reasonable medical dispute resolution had been proposed for over twenty years, "Act on Remedy for Damage from Medical Accident and Medical Dispute Mediation" was eventually enacted on April 7, 2011 and came into effect from April 8, 2012. This study evaluates the achievements and results of the past year, suggesting the future improvements or tasks. The main issue of Act on Medical Dispute Mediation is Korea Medical Dispute Mediation and Arbitration Agency. Therefore, the success of the Act depends on the outcomes of Korea Medical Dispute Mediation and Arbitration Agency. Although the Act has been enforced for only one year, this paper examines the outcomes of the Agency with limited materials for its development. Korea Medical Dispute Mediation and Arbitration Agency was established for rapid, fair, and effective medical dispute resolution. Thus, the evaluation of the performances of the Agency is based on the 1) rapidness, 2) fairness, and 3) effectiveness of the dispute resolution. To sum up, the system earned positive evaluations as for the rapidness and fairness, but some problems were indicated with regard to the effectiveness. As the system of medical dispute mediation and arbitration in Korea has no parallel in the world, other countries show many interests in it. The rapid and fair medical dispute resolution is of benefit in both patients and medical institutes and decreases social costs. As the Act had a difficult passage through Parliament, it should be maintained and improved continuously.

  • PDF

Design and Implementation of Laboratory Information System based on RFID (RFID를 기반으로 한 실험실 정보 시스템의 설계 및 구현)

  • Song, Sang-Ha;Jang, Seung-Jin;Kim, Hyo-Min;Yoon, Young-Ro
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.489-490
    • /
    • 2007
  • This paper is intended to trace and management of a medical specimen and its report in a hospital. To avoid missing and decaying specimen and to establish of order in the circulation of specimen, at the moment sampling, RFID tags for each are on examiner. And then, specimen is monitored easily, quickly and, correctly. We developed implementation LIS system has better CQI (Continuos Quality Improvement) using RFID and XML, ADO.net, ASP.net, C# 2.0. RFID technology replaces to an existing the bar-code system. Also for more convenience, we used a PDA-RFID module. The LIS system consists of main sorrel, SQL 2005, event display and analysis web page developed using asp.net 2.0 and sharing specimen data information using XML technology.

  • PDF

US FAA Physical Examination Standards and Amendment of AME Conservation Education: Comparison with Korea (미국 FAA 신체검사 기준 및 AME 보수교육 변화동향: 한국과의 비교)

  • Kim, Young Hyo
    • Korean journal of aerospace and environmental medicine
    • /
    • v.28 no.3
    • /
    • pp.52-55
    • /
    • 2018
  • The purpose of the aviation physical examination guideline is not only to determine the physical fitness of the aviation workers but also to treat the underlying diseases of the aviation employees effectively and to carry out the optimal aviation duties. As medical science advances, treatment guidelines for various diseases are rapidly changing, and aviation physical examination guidelines need to be revised accordingly. Therefore, it is necessary to analyze the change trends of the AME guideline around the world and appropriately reflect it according to the situation of Korea. It is also necessary to continue the training of AME who are required to carry out examinations and certificates by these revision guidelines. Therefore, it would be desirable to analyze the education system of the advanced countries including the US and introduce the advantages of these systems into Korean AME education curriculum. Primarily, with the development of the Internet, various online lectures have been developed recently. Therefore, we first aimed to look at the changes in the current AME guideline of the Federal Aviation Administration. Next, we aimed to discuss changes in the course of the AME refresher course. Finally, we would like to suggest some points to be improved by comparing these AME guidelines and educational programs with those of Korea.

A Study on the Present Status of Clinical Nurses with Expanded Role (진료협력간호사의 운영현황에 관한 연구)

  • Kwon, Young Dae;Sung, Young Hee;Kwon, In Gak;Hwang, Moon Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.14 no.3
    • /
    • pp.99-115
    • /
    • 2008
  • Purpose: The purpose for this study was to identify the present state of Clinical Nurses with Expanded Role (CNERs) and provide basic data to refine the roles of CNERs. In this study, CNREs refers to nurses who perform techniques traditionally done by doctors and use titles such as clinical nursing specialist, educator with consultation, research assistant, coordinator, physician assistant and special examiner. Method: This study was conducted from September 1 to November 12, 2007. Data from 684 nurses from 38 hospitals who responded to the questionnaire were analyzed with descriptive statistics using the SPSS 14.0 program. Results: The mean percentage of time spent was, for direct practice, 41.1%, for education and counseling, 22.8%, for consultation and coordination, 10.4%, for research, 6.8%, for administration, 8.9% and for other activities, 10.0%. The most frequently implemented CNERs, activities included consultation and education for patients and their families, counseling by telephone, history taking, physical examination, reading examination results, psychosocial assessment, managing treatment, input of prescriptions, and writing up patient records, Although not frequently performed, nurses in some fields carried out invasive procedures and prescribed medication and laboratory tests. Conclusion: Although the number of hospital CNERs are rapidly increasing, there is still confusion about the title and framework as well as standards. Furthermore, because some nurses are prescribing medication and laboratory tests as well as performing techniques not traditionally done by nurses, there is an absolute need for a legalized system and systematic education system for the safety of patients who are being cared by all CNERs.

  • PDF

The Vectra M3 3-dimensional digital stereophotogrammetry system: A reliable technique for detecting chin asymmetry

  • Hansson, Stina;Ostlund, Emil;Bazargani, Farhan
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.43-51
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the reliability of the Vectra M3 (3D Imaging System; Canfield Scientific, Parsippany, NJ, USA) in detecting chin asymmetry, and to assess whether the automatic markerless tracking function is reliable compared to manually plotting landmarks. Materials and Methods: Twenty subjects (18 females and 2 males) with a mean age of 42.5±10.5 years were included. Three-dimensional image acquisition was carried out on all subjects with simulated chin deviation in 4 stages (1-4 mm). The images were analyzed by 2 independent observers through manually plotting landmarks and by Vectra software auto-tracking mode. Repeated-measures analysis of variance and the Tukey post-hoc test were performed to evaluate the differences in mean measurements between the 2 operators and the software for measuring chin deviation in 4 stages. The intraclass correlation coefficient (ICC) was calculated to estimate the intra- and inter-examiner reliability. Results: No significant difference was found between the accuracy of manually plotting landmarks between observers 1 and 2 and the auto-tracking mode (P=0.783 and P=0.999, respectively). The mean difference in detecting the degree of deviation according to the stage was <0.5 mm for all landmarks. Conclusion: The auto-tracking mode could be considered as reliable as manually plotted landmarks in detecting small chin deviations with the Vectra® M3. The effect on the soft tissue when constructing a known dental movement yielded a small overestimation of the soft tissue movement compared to the dental movement (mean value<0.5 mm), which can be considered clinically non-significant.

Automatic real-name registration mark examiner research and development of special medical equipment for patient safety (환자 안전을 위한 특수의료장비의 검사자 실명제 자동 표식 등록 개발 연구)

  • Yoo, Se-Jong;Park, Jong-Bae;Kim, Jeong-Ho;Kim, Ki-Jin;Lim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.147-152
    • /
    • 2015
  • Through the inspector's real name to improve the quality of inspection is to show the design Radiological examination pursuant to the Ordinance of the Ministry of Health and Welfare for patient safety in the Image. However, the use of existing and in EMR, equipment within the handwriting input, the individual initial use has a problem. In this study, increasing the stability of the patient and the precise inspection, In order to increase the efficiency and convenience than the real-name system for quality control inspectors of medical equipment, Using the EMR and PACS developed and applied to evaluate the usefulness of automatic enrollment. Enter your information in the EMR, which was developed markers that inspectors use to compare the before and after images PACS satisfaction. Convenience than using traditional, consistency, the entry of the missing were higher as a statistically significant difference. A test strip automatic enrollment programs are developed in this study. You can increase the stability of the patient by checking the image to show the real tester, we expect the quality of care would be improved.

Study on 3D Printer Production of Auxiliary Device for Upper Limb for Medical Imaging Test (의료영상 검사를 위한 상지 보조기구의 3D 프린터 제작 연구)

  • Kim, Hyeong-Gyun;Yoon, Jae-Ho;Choi, Seong-Dae
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.389-394
    • /
    • 2015
  • There is a progressive development in the medical imaging technology, especially of descriptive capability for anatomical structure of human body thanks to advancement of information technology and medical devices. But however maintenance of correct posture is essential for the medical imaging checkup on the shoulder joint requiring rotation of the upper limb due to the complexity of human body. In the cases of MRI examination, long duration and fixed posture are critical, as failure to comply with them leads to minimal possibility of reproducibility only with the efforts of the examiner and will of the patient. Thus, this study aimed to develop an auxiliary device that enables rotation of the upper limb as well as fixing it at quantitative angles for medical imaging examination capable of providing diagnostic values. An auxiliary device has been developed based on the results of precedent studies, by designing a 3D model with the CATIA software, an engineering application, and producing it with the 3D printer. The printer is Objet350 Connex from Stratasys, and acrylonitrile- butadiene-styrene(ABS) is used as the material of the device. Dimensions are $120{\times}150{\times}190mm$, with the inner diameter of the handle being 125.9 mm. The auxiliary device has 4 components including the body (outside), handle (inside), fixture terminal and the connection part. The body and handle have the gap of 2.1 mm for smooth rotation, while the 360 degree of scales have been etched on the handle so that the angle required for observation may be recorded per patient for traceability and dual examination.