• Title/Summary/Keyword: the Color Band

Search Result 512, Processing Time 0.024 seconds

A New Liquid Crystal Color Calibration Technique Using Neural Networks and Median Filtering

  • Lee, Dae-Hee;Chung, Jae-Hun;Won, Se-Youl;Kim, Yun-Taek;Boo, Kwang-Suk
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.113-120
    • /
    • 2000
  • This study has developed a new liquid crystal calibration technique using Neural networks with median filtering and applied this technique to heat transfer measurements. To verify the validity of this new measurement technique, the local Nusselt numbers on a flat plate surface subjected to an axisymmetric impinging jet were measured and compared with the results by the conventional Hue-temperature calibration technique under the same conditions. Because the Neural networks predict the non-linear relations between temperatures and corresponding R, G, B values, Neural networks-median filtering calibration technique can utilize a much wider color band in the experiment than the Hue-temperature calibration technique, resulting in a significant reduction in the experimental time.

  • PDF

Simulation of Target Detection using UV and IR Band Signals (UV와 IR 대역 신호를 이용한 표적 신호 검출 시뮬레이션)

  • Du, Gyeong-Su;O, Jeong-Su;Jang, Seong-Gap;Hong, Hyeon-Gi;Seo, Dong-Seon;Choe, Jong-Su
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.1
    • /
    • pp.79-88
    • /
    • 2001
  • The target such as aircraft operates flares to protect itself from the missile. In general, Infra-red(IR) flares that are hot bodies radiating energy considerably greater than it does, so cause the missile to guide the flare instead of the target. For a precise target tracking in spite of a presence of flares, therefore, the seeker should discriminate the target signal from various clutters including the flare and the background. In this paper, we simulated 2-color rosette scan seeker using IR and UV(UltraViolet) bands. In each wave band, we analyzed the radiant distributions of the target, the flare, and background. These results showed that a simultaneous process in two bands can detect precisely the target.

  • PDF

The Color Variability Monitoring of HBC722

  • Baek, Giseon;Pak, Soojong;Green, Joel D.;Kang, Wonseok;Jeon, Yiseul;Choi, Changsu;Lee, Jeong-Eun;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.103.1-103.1
    • /
    • 2012
  • We present the results of SDSS r, i and z band photometry for HBC722 (also known as $LkH{\alpha}$ 188 G4, PTF10qpf and V2493 Cyg), with Camera for Quasars in Early uNiverse (CQUEAN) attached to 2.1m Otto Struve telescope at McDonald Observatory, USA. HBC722 is a newly erupted FU Orionis type object, which produced optical outburst (${\Delta}V$=4.7 mag) over a year that peaked in 2010 September. We carried out the monitoring observations during 48 nights from 2011 April to 2012 June to check the short-term and the long-term variabilities for chasing the Keplerian rotation of the system. Comparing the photometric results of r, i and z band, we describe the color variability which is related to the physical properties of the system like circumstellar disk and accretion process.

  • PDF

Synthesis of Super Hydrophobic Orange Dyes Having Maximum Absorption at 450-500nm for Pure Polyolefin Fibers (450-500nm의 최대흡수를 가지는 순수 폴리올레핀 소재용 초소수성 오렌지 염료의 합성)

  • Kim, Taekyeong;Ryu, Myeonghwa
    • Textile Coloration and Finishing
    • /
    • v.26 no.3
    • /
    • pp.165-172
    • /
    • 2014
  • Novel super hydrophobic orange dyes having maximum absorption band at 450-500nm were synthesized to dye polyolefin fibers such as polypropylene and ultra high molecular weight polyethylene fibers, using 4-alkylanilines and ${\beta}$-naphthol. Their absorption spectra at visible range showed almost the same, which meant that the alkyl substituents introduced to chromophore did not affect on color appearance of the dyes. Considering both color strength and wash fastness, the decyl-substituted dye was determined as the optimum one practically. From the dyeing results at various conditions, the optimum dyeing was $130^{\circ}C$ for 1 hour with 5% owf of dyes. The good fastness ratings to washing, rubbing were obtained showing 4-5 for both fibers. Light fastness was also acceptable giving rating 3-4 for polypropylene fibers and rating 3 for ultra high molecular weight polyethylene fibers.

Analysis of the spectroscopic characteristics of Ground color images using a digital camera (디지털 카메라를 활용한 컬러 지상영상의 분광학적 특성 분석)

  • Ko, In-Chul;Seo, Su-Young
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.06a
    • /
    • pp.137-144
    • /
    • 2010
  • Ground digital image data obtained by using DSLR camera can be used to the ground photogrammetry and spatial modeling. Intensity of each pixel in digital video images is the most important parameter to generate digital image. Therefore, it is needed to estimate the parameters and spectral characteristics of digital cameras in order to take more definite intensity data. In this study, using the Sony DSC-F828 DSLR camera, seven digital images are obtained by the continuous shooting. (frame rate, 0.38 seconds). And then extract the value of the intensity from RGB band of each digital color photographs to confirm difference of intensity between frames. The purpose of this study is to confirm spectral characteristics and changes and to estimate correlation through the analysis of statistical in each pixel of R, G, B band.

  • PDF

Research for development of small format multi -spectral aerial photographing systems (PKNU 3) (소형 다중분광 항공촬영 시스템(PKNU 3호) 개발에 관한 연구)

  • 이은경;최철웅;서영찬;조남춘
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.143-152
    • /
    • 2004
  • Researchers seeking geological and environmental information, depend on remote sensing and aerial photographic datum from various commercial satellites and aircraft. However, adverse weather conditions as well as equipment expense limit the ability to collect data anywhere and anytime. To allow for better flexibility in geological and environmental data collection, we have developed a compact, multi-spectral automatic Aerial Photographic system (PKNU2). This system's Multi-spectral camera can record visible (RGB) and infrared (NIR) band (3032*2008 Pixels) images Visible and infrared band images were obtained from each camera respectively and produced color-infrared composite images to be analyzed for the purpose of the environmental monitoring. However this did not provide quality data. Furthermore, it has the disadvantage of having the stereoscopic overlap area being 60% unsatisfied due to the 12 seconds of storage time of each data The PKNU2 system in contrast, photographed photos of great capacity Thus, with such results, we have been proceeding to develop the advanced PKNU2 (PKNU3) system that consists of a color-infrared spectral camera that can photograph in the visible and near-infrared bands simultaneously using a single sensor, a thermal infrared camera, two 40G computers to store images, and an MPEG board that can compress and transfer data to the computer in real time as well as be able to be mounted onto a helicopter platform.

  • PDF

Electrical Properties of ZnTe-lnSb Heterojunctions (ZnTe-InSb Heterojunction의 전기적 특성)

  • 김화택
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.4
    • /
    • pp.35-40
    • /
    • 1975
  • The Zn7e-lnSb heterojunctions was prepared by interface alloying technique. The structure of this beterojunction had p-i-n which semi-insulating ZnTe laver at interface of this heterojunction was formed by diffusing In of InSb into ZnTe crystal. The current transport mechanism of this heterojunction was Spacecharge-Limited-Current(SCLC) mechanism by hole at semi-insulating ZnTe layer. The hole wart injected from valence band of p- type SnTe crystal. Orange color electroluminescence was observed at this heterojunction when forward and reversed bias voltage applied.

  • PDF

Development & Reliability Verification of Ultra-high Color Rendering White Artificial Sunlight LED Device using Deep Blue LED Light Source and Phosphor (Deep Blue LED 광원과 형광체를 이용한 초고연색 백색 인공태양광 LED 소자의 개발)

  • Jong-Uk An;Tae-Kyu Kwon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.59-68
    • /
    • 2023
  • Currently, yellow phosphor of Y3Al5O12:Ce3+ (YAG:Ce) fluorescent material is applied to a 450~480nm blue LED light source to implement a white LED device and it has a simple structure, can obtain sufficient luminance, and is economical. However, in this method, in terms of spectrum analysis, it is difficult to mass-produce white LEDs having the same color coordinates due to color separation cause by the wide wavelength gap between blue and yellow band. There is a disadvantage that it is difficult to control optical properties such as color stability and color rendering. In addition, this method does not emit purple light in the range of 380 to 420nm, so it is white without purple color that can not implement the spectrum of the entire visible light spectrum as like sunlight. Because of this, it is difficult to implement a color rendering index(CRI) of 90 or higher, and natural light characteristics such as sunlight can not be expected. For this, need for a method of implementing sunlight with one LED by using a method of combining phosphors with one light source, rather than a method of combining red, blue, and yellow LEDs. Using this method, the characteristics of an artificial sunlight LED device with a spectrum similar to that of sunlight were demonstrated by implementing LED devices of various color temperatures with high color rendering by injecting phosphors into a 405nm deep blue LED light source. In order to find the spectrum closest to sunlight, different combinations of phosphors were repeatedly fabricated and tested. In addition, reliability and mass productivity were verified through temperature and humidity tests and ink penetration tests.

Molecular cloning of Prophenoloxidase (PPO) gene related to melanin formation of elytra of Harmonia axyridis (무당벌레(Harmonia axyridis) 초시색상 패턴의 유전 및 이의 관련유전자 탐색)

  • Kim, Sae-Hee;Seo, Mi-Ja;Park, Min-Woo;Yu, Yong-Man;Youn, Young-Nam
    • Korean Journal of Agricultural Science
    • /
    • v.39 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • In order to cloning of PPO gene as a melanin formation related genes involved in hardening and pigmentation of insect integument or wing, we cloned cDNA and analyzed the sequence of PPO gene of H. axyridis. PPO2 primer were designed based on the sequences of PPO genes of Tribolium castaneum and Drosophila melanogaster, and then plasmid DNA were cloned from PCR products obtained from different two color patterns. When the plasmid DNA band pattern were digested by restriction enzymes, BamH1, Xba1, and EcoR1, we found same size band pattern. However, this sequence was not homologous to sequence of T. castaneum PPO gene. Using the primer designed based on the sequence of D. melanogaster, 209 bp PCR product was observed.

Role of endoscopy in gastroesophageal reflux disease

  • Daniel Martin Simadibrata;Elvira Lesmana;Ronnie Fass
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.681-692
    • /
    • 2023
  • In general, gastroesophageal reflux disease (GERD) is diagnosed clinically based on typical symptoms and/or response to proton pump inhibitor treatment. Upper gastrointestinal endoscopy is reserved for patients presenting with alarm symptoms, such as dysphagia, odynophagia, significant weight loss, gastrointestinal bleeding, or anorexia; those who meet the criteria for Barrett's esophagus screening; those who report a lack or partial response to proton pump inhibitor treatment; and those with prior endoscopic or surgical anti-reflux interventions. Newer endoscopic techniques are primarily used to increase diagnostic yield and provide an alternative to medical or surgical treatment for GERD. The available endoscopic modalities for the diagnosis of GERD include conventional endoscopy with white-light imaging, high-resolution and high-magnification endoscopy, chromoendoscopy, image-enhanced endoscopy (narrow-band imaging, I- SCAN, flexible spectral imaging color enhancement, blue laser imaging, and linked color imaging), and confocal laser endomicroscopy. Endoscopic techniques for treating GERD include esophageal radiofrequency energy delivery/Stretta procedure, transoral incisionless fundoplication, and endoscopic full-thickness plication. Other novel techniques include anti-reflux mucosectomy, peroral endoscopic cardiac constriction, endoscopic submucosal dissection, and endoscopic band ligation. Currently, many of the new endoscopic techniques are not widely available, and their use is limited to centers of excellence.