• Title/Summary/Keyword: the AIR model

Search Result 5,901, Processing Time 0.044 seconds

Outbound Air Travel Demand Forecasting Model with Unobserved Regional Characteristics (미관찰 지역 특성을 고려한 내국인 국제선 항공수요 추정 모형)

  • YU, Jeong Whon;CHOI, Jung Yoon
    • Journal of Korean Society of Transportation
    • /
    • v.36 no.2
    • /
    • pp.141-154
    • /
    • 2018
  • In order to meet the ever-increasing demand for international air travel, several plans are underway to open new airports and expand existing provincial airports. However, existing air demand forecasts have been based on the total air demand in Korea or the air demand among major cities. There is not much forecast of regional air demand considering local characteristics. In this study, the outbound air travel demand in the southeastern region of Korea was analyzed and the fixed-effects model using panel data was proposed as an optimal model that can reflect the inherent characteristics of metropolitan areas which are difficult to observe in reality. The results of model validation show that panel data analysis effectively addresses the spurious regression and unobserved heterogeneity that are difficult to handle in a model using only a few macroeconomic indicators with time series characteristics. Various statistical validation and conformance tests suggest that the fixed-effects model proposed in this study is superior to other econometric models in predicting demand for international demand in the southeastern region.

Improvement of Thermal Enviromental by Two Air Out in Hot Air Heating (이중 취출구에 의한 온풍난방시의 열환경 개선)

  • Jang, In-Seong;Kim, J.S
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.209-217
    • /
    • 1997
  • The objective of this paper is to improve a discomfort caused by the unequal airflow and vertical temperature difference by buoyancy of the supplied hot air in the conventional hot air heating system. In order to the model experiment we manufactured the hot air heater with two air outlet and a model room. We observed the temperature, velocity and airflow distribution and calculated values of PMV and PPD using mean value of central verticality section's air temperature and velocity. We could improve distribution of vertical temperature and velocity at the central section of the model room owing to correlation of hot air of two air outlet.

  • PDF

Experimental Study on Development of Air Leakage Model and Performance Characteristics of a Desiccant Rotor (제습로터의 공기누설모델 개발 및 성능 특성에 관한 실험적 연구)

  • Kang, Byung-Ha;Pi, Chang-Hun;Chang, Young-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.37-45
    • /
    • 2012
  • This study investigates the pressure leakage characteristics of a desiccant rotor with a brush-type air seal. Through a pressure leakage experiment, a correlation equation for the leakage air flow rate is obtained as a function of the air seal area and pressure difference. Using this equation, an air leakage model for the desiccant rotor is developed. By comparing simulation results with the experimental results for the desiccant rotor, the accuracy of the air leakage model is demonstrated. A performance test of a desiccant rotor with various air flow rates is carried out. Using the air leakage model, the effective mass flow rate and air leakage rate are found. In addition, the characteristics of the air leakage are analyzed for a desiccant cooling system using the developed air leakage model.

A Development of Air Dispersion Modeling Software, AirMaster (대기확산 모델링 Software, AirMaster 개발)

  • Koo, Youn-Seo;Yoon, Hee-Young;Kim, Sung-Tae;Jeon, Kyung-Seok;Park, Sung-Soon;Kweon, Hee-Yong;Hwang, Ju-Hyun;Kim, Jong-Hwa;Choi, Jong-Keun;Lee, Im-Hak
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.4
    • /
    • pp.323-338
    • /
    • 2000
  • A Korean air dispersion modeling software, AirMaster, was developed on a basis of dispersion theories adopted in U.S. EPA's ISC3 (Industrial Source Complex - version 3) model to assess the air quality impact from the stacks. Key characteristics of AirMaster are as follows: 1) The building downwash effect can be easily simulated; 2) The screen, long term, and short term models can be run independently; 3) The input data to run the model such as meteorological and terrain data are supplied automatically from the databases in AirMaster; and 4) The modeling procedure is easy and simple under the GUI window environment. In order to validate AirMaster, comparisons with ISC3 model and Indianapolis tracer experiment were carried out. It was shown that AirMaster was identical to ISCST3 and ISCLT3 models in predicting the 1 hr to annual concentrations from the stack under various stack emission and meteorological conditions. The 1 hr concentrations predicted by AirMaster also showed a good agreement with the Indianapolis tracer measurements.

  • PDF

Statistical Models of Air Temperatures in Seoul (서울시 도시기온 변화에 관한 모델 연구)

  • 김학열;김운수
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.3
    • /
    • pp.74-82
    • /
    • 2003
  • Under the assumption that the temperature of one location is closely related to land use characteristics around that location, this study is carried out to assess the impact of urban land use patterns on air temperature. In order to investigate the relationship, GIS techniques and statistical analyses are utilized, after spatially connecting urban land use data in Seoul Metropolitan Area with atmospheric data observed at Automatic Weather Stations (AWS). The research method is as follows: (1) To find out important land use factors on temperature, simple linear regressions for a specific time period (pilot study) are conducted with urban land use characteristics, (2) To make a final model, multiple regressions are carried out with those factors and, (3) To verify that the final model could be appled to explain temperature variations beyond the period, the model is extensively used for 5 different time periods: 1999 as a whole; summer in 1999; 1998 as a whole; summer in 1998; August in 1998. The results of simple linear regression models in the pilot study show that transportation facilities and open space area are very influential on urban air temperature variations, which explain 66 and 61 percent of the variations, respectively. However, the other land use variables (residential, commercial, and mixed land use) are found to have weak or insignificant relationship to the air temperatures. Multiple linear regression with the two important variables in the pilot study is estimated, which shows that the model explains 75 percent of the variability in air temperatures with correct signs of regression coefficients. Thus, it is empirically shown that an increase in open space and a decrease in transportation facilities area can leads to the decrease in air temperature. After the final model is extensively applied to the 5 different time periods, the estimated models explain 68 ∼ 75 percent of the variations in the temperatures is significant regression coefficients for all explanatory variables. This result provides a possibility that one air temperature model for a specific time period could be a good model for other time periods near to the period. The important implications of this result to lessen high air temperature we: (1) to expand and to conserve open space and (2) to control transportation-related factors such as transportation facilities area, road pavement and traffic congestion.

Numerical simulation of air layer morphology on flat bottom plate with air cavity and evaluation of the drag reduction effect

  • Hao, W.U.;Yongpeng, O.U.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.510-520
    • /
    • 2019
  • To investigate the morphology characteristics of air layer in the air cavity, a numerical method with the combination of RANS equations and VOF two-phase-flow model is proposed for a plate with air cavity. Based on the model above, the dynamic and developmental process of air layer in the air cavity is studied. Numerical results indicate that the air layer in the plate's air cavity exhibits the dynamic state of morphology and the wavelength of air layer becomes larger with the increasing speed. The morphology of air layer agrees with the Froude similarity law and the formation of the air layer is not affected by the parameters of the cavity, however, the wave pattern of the air layer is influenced by the parameters of the cavity. The stable air layer under the air cavity is important for the resistance reduction for the air layer drag reduction.

Design Observable Model of Direct Drive Motor for Air Gap Estimation when Input Disturbance is Impulse signal (외란이 충격 신호일 때 공극 추정을 위한 직구동 모터의 관측 가능한 수학적 모델 수립)

  • Ki, Tae-Seok;Park, Youn-Sik;Park, Young-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.7
    • /
    • pp.627-631
    • /
    • 2012
  • Observable mathematical model of DDM (Direct Dirve Motor) was suggested. The motor that operates the object system directly is called DDM. DDM has many strong points, however, it has a significant disadvantage, that it is more sensitive to the external force than the motor with reduction gear. In other word, if the force is applied, air gap of the motor can be perturbed. This causes not only difficulty in motor control but also even more serious problem, such as the breakdown of motor. However, if the air gap variation can be estimated, it can help prevent these problems. DDM should be modeled to estimate the air gap variation. The type of researched DDM is PMSM (Permanent Magnet Synchronous Motor) and precedent model of PMSM includes only characteristics of electro-magnetic system and rotational motion. However, suggested model should also include characteristics of translational motion of rotor to estimate the air gap variation. Also, this model should satisfy observability condition, because state observer is designed based on this model.

The Study on Thermal Characteristic of the Balcony with Natural Ventilation System (자연환기시스템을 부착한 발코니의 열적 특성에 관한 연구)

  • Cho Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.347-354
    • /
    • 2005
  • This paper compared vertical temperature distribution between the existing balcony model without ventilator facilities and the improved balcony model with ventilator facilities using differential equation. As the air inside of balcony is heated by solar radiation this heated air is not exhausted in the existing balcony, remaining stagnant. The air temperature distribution was $26.7{\sim}29.3^{\circ}C$ in balcony without natural ventilator system. This heated air affected the rising air temperature of adjacent spaces such as living room and bedroom in the existing balcony. But, as the heated air inside of the improved balcony model is exhausted through natural ventilator facilities in summer, the air temperature in balcony has fallen. The air temperature distribution in improved balcony was $24.8{\sim}26.7^{\circ}C$ for the inlet air speed of 1 m/s and $24.6{\sim}26.7^{\circ}C$ for the inlet air speed of 3 m/s. The energy consumption of the improved balcony is 2.5 times less than of the existing balcony. The improved balcony with the closed damper makes a roll as the existing balcony in the aspect of the heating effect. When the heated air in the improved balcony is supplied, the air temperature is raised and the ventilation effect in adjacent spaces was improved.

A Study on Numerical Simulation for the Work Environment Improvement of Highway Tollgate Booth (고속도로 요금소 부스 근무환경 개선을 위한 기류해석 연구)

  • 김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.129-140
    • /
    • 2000
  • Simulation study has been carried out to analyze the air flow supplying from the heat pump system inside the tollgate booth by using the Phoenix computer simulation program. Through this simulation analysis we can find the problem of present tollgate booth in terms of air flow and recommend an improved model also simulate this model. Final results as follows; It was turned out that the fresh air conditioning is not provided to the worker effectively due to the improper location of inlet and outlet in the present tollgate booth in addition to that the air curtain system applied in the booth lowered air circulation from outside. The improved model was suggested first to increase the air curtain effect by downsizing the window and by installation of the air curtain suction line to reduce the induced outdoor air second to supply the fresh air to the worker directly by relocation of the inlet and outlet of supplying air. With these improved modifications better results have been reached in terms of air flow inside the booth. Next through the air flow simulation of outside booth the contaminated outdoor air has been easuily infiltrating into the booth through the window because of its rectangle shape. Stream like shape of booth has been proposed through the computer simulation as an alternative shape of tollgate booth for a new design.

  • PDF

Sensitivity Analysis of Indoor Environment Factors along with Changes of Outdoor Air Condition (외기상태의 변화에 따른 실내 환경인자의 민감도 분석)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.2
    • /
    • pp.125-136
    • /
    • 2010
  • The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. A sensitivity analysis of indoor environment factors was carried out to grasp influences along with changes of atmospheric conditions. An integrated multizone model was used to predict these sensitivities. This model was applied to an apartment with six zones. Airflow rates are influenced very seriously by changes of wind direct or wind velocity, but are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air temperatures are influenced very directly by changes of outdoor air temperature, but are influenced very slightly by wind direction or wind velocity and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air humidities are influenced very directly by changes of outdoor air humidity, but are not influenced at all by changes of outdoor air contaminant concentration and have little or no influence by changes of wind direction, wind velocity, or outdoor air temperature. Indoor air contaminant concentrations are influenced very seriously by changes of wind direct or wind velocity, but are influenced somewhat by changes of outdoor air contaminant concentration and are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity.