Browse > Article
http://dx.doi.org/10.5322/JES.2010.19.2.125

Sensitivity Analysis of Indoor Environment Factors along with Changes of Outdoor Air Condition  

Cho, Seok-Ho (Department of Environmental Administration, College of Applied Science, Catholic University of Pusan)
Publication Information
Journal of Environmental Science International / v.19, no.2, 2010 , pp. 125-136 More about this Journal
Abstract
The most important factors relating to the indoor air environment are temperature, airflow, humidity, and contaminant concentration. A sensitivity analysis of indoor environment factors was carried out to grasp influences along with changes of atmospheric conditions. An integrated multizone model was used to predict these sensitivities. This model was applied to an apartment with six zones. Airflow rates are influenced very seriously by changes of wind direct or wind velocity, but are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air temperatures are influenced very directly by changes of outdoor air temperature, but are influenced very slightly by wind direction or wind velocity and are not influenced at all by changes of outdoor air humidity or contaminant concentration. Indoor air humidities are influenced very directly by changes of outdoor air humidity, but are not influenced at all by changes of outdoor air contaminant concentration and have little or no influence by changes of wind direction, wind velocity, or outdoor air temperature. Indoor air contaminant concentrations are influenced very seriously by changes of wind direct or wind velocity, but are influenced somewhat by changes of outdoor air contaminant concentration and are influenced very slightly by changes of outdoor air temperature and are not influenced at all by changes of outdoor air humidity.
Keywords
Indoor air environment; Multizone model; Sensitivity analysis; Sensitivity coefficients;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Shair, F. H., Heitner, K. L., 1974, Theoretical model for relating indoor pollutant concentrations to those outside, Environ. Sci. Tech., 8, 441-451.   DOI
2 Wadden, R. A., Scheff, P. A., 1983, Indoor air pollution, John Wiley & Sons, Inc., 105-132.
3 Walton, G. N., 1982, Airflow and multiroom thermal analysis, ASHRAE Transactions, 88(2), 78-91.
4 Walton, G. N., 1984, A computer algorithm for prediction infiltration and interoom airflows, ASHRAE Transactions, 90(1B), 601-610.
5 Walton, G. N., 1989, Airflow network models for element-based building airflow modeling, ASHRAE Transactions, 95(2), 611-620.
6 Waters, J. R., Simons M. W., 1987, The evalution of contaminant concentrations and airflows in a multizone model of a building, Building and Environment, 22(4), 305-315.   DOI
7 Zhang, J. S., 2005, Combined heat, air, moisture, and pollutants transport in building environmental systems, JSME International Journal, Series B, 48(2), 182-190.   DOI
8 조석호, 2000, 다구획 모델에 의한 실내공기질의 평가, 지산대학 논문집, 18, 181-192.
9 김병선, 박종상, 1997, 건물 에너지성능 시험시 입력변수와 출력변수의 민감도, 대한건축학회논문집, 13(8), 109-120.
10 조석호, 양성환, 이봉헌, 정성욱, 이병호, 1998, 실내공기 질 평가를 위한 2구획 모델의 개발, 한국환경과학회지, 7(6), 745-751.
11 조석호, 2001, 다구획 실내환경에서의 공기유동량의 예측, 부산가톨릭대학교 논문집, 1, 175-183.
12 조석호, 2008, 실내공기환경 예측을 위한 통합 다구획 모델의 개발, 한국환경과학회지, 17(9), 993-1003.   과학기술학회마을   DOI
13 Chung, K. C., 1996, Development and validation of a multizone model for overall indoor air environment prediction, HVAC & R Research, 2(4), 376-385.   DOI   ScienceOn
14 Diasty, R. EL., Fazio, P., Budaiwi, I., 1992, Modelling of indoor air humidity : the dynamic behavior within an enclosure, Energy and Building, 61-73.
15 Ohira, N., Yagawa, N., Gotoh, N., 1993, Development of a measurement system for multizone infiltration, ASHRAE Transactions, 99, 692-698.