• Title/Summary/Keyword: tests

Search Result 36,881, Processing Time 0.068 seconds

Natural dyeing with aqueous Extracts of Black bean seed coat (검정팥 종피 추출물에 의한 천연염색)

  • Cha, Hae-Suk;Jung, Yang-Sook;Bae, Do-Gyu
    • Current Research on Agriculture and Life Sciences
    • /
    • v.30 no.2
    • /
    • pp.76-81
    • /
    • 2012
  • In this study the natural colorant was extracted from black bean seed coat in aqueous solution and used to dye silk and cotton fabrics. To obtain the optimal dyeing conditions it was examined at various dyeing condition (temperature, pH, time and liquor ratio). The dyeing behavior and the depths of shade which were evaluated in terms of K/S and CIELAB color difference values of the dyed and mordanted fabrics were also investigated. The dyeing fastness evaluated standard light and wash fastness tests. The obtained results were as follows ; The most K/S value of silk and cotton fabrics were obtained when the pH was 4.0 and 4.8, respectively and it increased slightly with dyeing time passes when the dyeing temperatures were at $40^{\circ}C$ and $60^{\circ}C$ but, it increased at $80^{\circ}C$. The color of silk fabrics changed from yellowish red to yellow at only Fe mordanting among various mordanting. Sn and Ti mordanting of silk fabric and only Ni mordanting of cotton fabric increased the $L^*$ values, but the others decreased. The light fastness of silk fabrics showed 4-6 grade without mordant, 4-5 grade with Al, 3-4 grade with Cu and Sn, and 2-3 grade with Fe as mordant, and that of cotton fabrics showed 1-2 grade without mordant, 2-3 grade with Fe, 2 grade with Cu, 1-2 grade with Al and Sn as mordants. All mordanting coluld not improve the light fastness of fabrics. Washing fastness(fade) of silk fabrics showed 2 grade without mordants and 2-3 grade with mordants and those of cotton fabrics showed 4 grade with Cu, 3 grade without mordant and with Al, Sn and Fe. All of the washing fastness(stain) of both fabrics showed 4-5 grade.

  • PDF

Effects of circulation exercise on health-related physical fitness, blood pressure and blood vessel elasticity of obese women in the 50s (순환운동이 50대 비만중년여성의 건강체력, 혈압 및 혈관탄성도에 미치는 영향)

  • Kim, Yeon-Joo;Kim, Ji-Hyeon;Ha, Soo-Min;Kim, Jung-Sook;Kim, Jong-Won;Yoon, Byeong-Kon;Kim, Do-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.756-768
    • /
    • 2017
  • The subjects for the study were twenty four obese women(50's) composed of the exercise group(n=12) and to a "no exercise" control group(n=12). The variables of health-related fitness, blood pressure, and blood vessel elasticity where measured in all the subjects before the start of the training program and after at the end of the 8 weeks circuit training. The test data were analyzed by t-test, paired t-test, and alpha level of p<.05 was set for all tests of significance. Health-related fitness was exercise group, the BMI had significantly decreased, and the 20m shuttle run, sit-ups and sit-and-reach had significantly increased. Blood pressure was exercise group, the systolic blood pressure, and diastolic blood pressure had significantly decreased. Also, after the circuit training program, the exercise group had significantly higher diastolic blood pressure than did the control group. blood vessel elasticity was exercise group, the blood vessel elasticity had significantly decreased. And exercise group had significantly higher diastolic blood vessel elasticity than did the control group. In conclusion, BMI, systolic blood pressure, and diastolic blood pressure had significantly decreased, but 20 m shuttle run, sit-ups and sit-and-reach had significantly increased in the combined exercise group after the 8 weeks circuit training. Therefore, regular and continuous circuit training were effective in improving the body composition, blood pressure, blood vessel elasticity and health-related fitness.

Effects of Cornus Officinalis Extract on Blood Fatigue Substance, Muscle Damage and Liver Function during Winter Training in Middle School Male Soccer Players (동계훈련 시 산수유 추출물 섭취가 남중 축구선수의 혈중 피로물질, 근 손상 및 간 기능에 미치는 영향)

  • Park, Sung-Hwan;Ha, Soo-Min;Ha, Min-Seong;Baek, Yeong-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.827-838
    • /
    • 2017
  • Twenty male soccer players volunteered as the experimental subjects. The subjects were randomly assigned to the "Winter training with Cornus officinalis extract intake group"(WCI; n=10) and "Winter training group"(WT; n=10). The variables of blood fatigue substance, muscle damage and liver function where measured in all the subjects before the start of the Cornus officinalis intake after at the end of the 4 weeks winter training. Winter training program was proceeded with 6 days a week for 4 weeks. Exercise intensity was measured using the HRR(70~95%). Changes in the heart rate were also measured with the Polar. WCI group were ingested 80 mL of Cornus officinalis extract after every breakfast and dinner for 4 weeks. The test data were analyzed by paired t-test, and independent t-test(%diff), and the alpha level of p<.05 was set for all tests of significance. Lactate in WCI group had significantly decreased, and the changes between the groups were significantly lower in the WCI group than in the WT group. Ammonia in WCI group had significantly increased. CK in WCI group had significantly decreased. LDH in both group had significantly decreased. AST in WCI group had significantly decreased, and the changes between the groups were significantly lower in the WCI group than in the WT group. ALT in WCI group had significantly decreased. In conclusion, the results of this study show that Cornus officinalis extract seem to have a positive influence on blood fatigue substance, muscle damage and liver function. Therefore Cornus officinalis extract is considered to be able to contribute an ergogenic aids.

Isolation and Characteristics of Yersinia spp. from Mineral Spring Waters (먹는 샘물에서 분리한 Yersinia spp.의 분리 및 특성)

  • 이택수;박부길;오덕환
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.5
    • /
    • pp.796-801
    • /
    • 2001
  • A total of 277 mineral spring water samples in Kangwon province from 1999 to 2000 were analyzed for the presence of Yersinia spp. by the conventional Food and Drug Administration protocol, and presumptive strains were identified by morphological, cultural and biochemical tests according to Bergey’s manual. Also, the biotypes, serotypes, and susceptibility to 12 antibiotics were tested. Among the total 277 mineral spring water samples, 40 samples (14.4%) were found to be contaminated with Yersinia species. Among the 40 strains of Yersinia spp. isolates, 33 strains (82.5%) for Yersinia enterocolitica, 4 strains (10%) for Yersinia frederiksenii, 2 strains (5%) for Yersinia intermedia, and 1 strain (2.5%) for Yersinia sakazaki were identified, respectively. Of 40 Yersinia spp. isolates, Yersinia enterocolitica (82.5%) was the most predominant species in the mineral spring water samples compared to other Yersinia species. Compared to direct culture method after KOH treatment and KOH treatment method after cold enrichment for better isolation ratio of according to comparision of Yersinia species, the detection ration (18.5%) of KOH treatment method after cold enrichment was about 3 times better than that (6.1%) of direct culture method after KOH treatment. According to serotypes of Y. enterocolitica isolates, O : 5 (12.9%) was the most predominant and followed by O : 3 (9.7%), O : 8 (6.5%), and O : 9 (3.2%), and others. For biotypes of Y. enterocolitica isolates, 1A (71.0%) was the most predominantly abundant and followed by 3A (12.9%), 3B (9.7%), 1B (3.2%) and 5 (3.2%). Also, an antibiotic susceptibility test showed that Yersinia spp. isolates were very susceptible to the antibiotics tested, but they were very strongly resistant to ampicillin, cephalothin and carbenicillin.

  • PDF

Effects of Chronic and Acute Stress on Clusterin Secretion of the Rat Submandibular Gland (급만성 스트레스가 백서 악하선의 Clusterin 분비에 미치는 영향)

  • Jin, Sang-Bae;Chun, Yang-Hyun;Hong, Jung-Pyo
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.79-89
    • /
    • 2006
  • The aim of this study is to know how the rat submandibular gland changes under various emotional stress condition, using molecular biological methods. Restraint and chronic unpredictable mild stress (CUMS) experiment is conducted on fifty one 7-week old Sprague-Dawley rats (restraint stress experiment: 21, CUMS: 30). The rats were sacrificed, the submandibular glands were excised immediately at certain time, and examined by the use of immunohistochemistry and western blotting. In CUMS experiment, sucrose preference test, water intake change, weight change were implemented at 1 week interval for the experimental period The results are as follows: 1. The number of clusterin-secreting cells of restraint stress group compared to control group showed significantly decreasing tendency in all experimental groups except for the 1st hour group (p<0.001 in the 9th, 24th, 72nd, 120th, and 168th hour group). 2. The number of clusterin-secreting cells of CUMS group compared to control group showed significantly increasing tendency in the 2nd week group (p<0.01), and significantly decreasing tendency in the 4th and 5th week group (p<0.001). 3. Sucrose preference test in CUMS experiment showed significant difference between the 5th week experimental group and control group (p<0.01). 4. Weight change in CUMS experiment showed significant difference between the 5th week experimental group and control group (p<0.01), but water intake change didn't show significant difference compared to control group. 5. In western blot analysis, clusterin expression was decreased on a gradual basis in due time compared to the control group in the restraint stress group. As for CUMS group (chronic unpredictable mild stress group), it was increased till the 2nd week and decreased till the 5th week after that, which is similar to immunohistochemical analysis result and the decreasing tendency of sucrose preference and weigh changes. Through the test, it was proved that expression of clusterin in saliva glands decreases after receiving either acute or chronic stress, indicating relation with depression caused by chronic stress. Unlike other data, however, apoptotic tendency was hardly found in tissues. Diverse possibilities could be suggested on that: first, the stress was not enough to expedite apoptosis; second, apoptosis-related protein was already being secreted though not detected with microscope; third, clusterin, a major secretion molecule of saliva, decreased with saliva's malfunction due to stress. In the respect, it will be necessary to examine proteins expressed in case of cell death or other heat-shock proteins at the same time, in order to see whether any cellular change or death is caused by decreasing clusterin under high stress, and whether the original state is restored as time goes by under mild stress, through longer-term tests using even higher acute stress.

Effect of resin cement color on the color of commercially available zirconia crown (레진시멘트 색상이 상용 지르코니아 크라운의 색상에 미치는 영향)

  • Ha, Hyeon-Seung;Lim, Bum-Soon;Rhee, Sang-Hoon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.233-242
    • /
    • 2018
  • The purpose of this study is to evaluate the effect of resin cement color on the color of commercially available zirconia crown. The zirconia and resin cements used for the experiment were $NuSmile^{(R)}$ ZR Zirconia LT Shade (LT), $RelyX^{TM}$ U200 TR, A2, and A3O (TR, A2, A3O). The disks of zirconia and resin cements with diameters of 5 mm and thicknesses of 1 mm were prepared. Five disks were made for each specimen. The CIE $L^*a^*b^*$ values of zirconia, resin cements and the combinations thereof were measured on black and white backgrounds, respectively, using a spectrophotometer. The color effect of resin cement on the color of the zirconia crown was evaluated by calculating translucency parameter (TP), contrast ratio (CR), and color differences (${\Delta}E{^*}_{ab}$) based on the measured CIE $L^*a^*b^*$ values. The statistical significances were verified by one-way ANOVA and the Tukey-multiple comparisons tests. As a result, the TP and CR values were decreased (p<0.05) and increased, respectively, in the combination of zirconia and resin cement disks compared to zirconia disk per se. When using the black background, the ${\Delta}E{^*}_{ab}$ values between zirconia and the combination of the zirconia and three resin cement disks were imperceptible level. The A3O showed the lowest ${\Delta}E{^*}_{ab}$ value among three resin cements. When using the white background, the ${\Delta}E{^*}_{ab}$ values between zirconia and the combination of zirconia and TR resin cement (LT/TR) disks showed acceptable level. However, the ${\Delta}E{^*}_{ab}$ values between zirconia and the combination of zirconia and A2 resin cement (LT/A2) disks showed unacceptable level. Meanwhile, the ${\Delta}E{^*}_{ab}$ values between zirconia and the combination of zirconia and A3O resin cement (LT/A3O) disks showed perceptible but acceptable level. Within the limits of this study, the colors of resin cements did not cause unacceptable color changes of zirconia except the combination of LT/A2 on the white background. The resin cement that gave the least color changes to zirconia was A3O. This means that the resin cement A3O is recommended to use for minimizing color changes when cementing commercially available zirconia crown to tooth.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

The Effectiveness of Visual Field C10-2 in the Early Detection of Glaucoma with Parafoveal Scotoma (중심부 시야결손을 보이는 초기 녹내장 환자의 진단에서 자동시야계 C10-2의 유용성)

  • Hwang, Bo Een;Park, Hae-Young Lopilly;Park, Chan Kee
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.3
    • /
    • pp.321-326
    • /
    • 2017
  • Purpose To identify the correspondence between the central sensitivity of several visual field (VF) tests and ganglion cell inner plexiform layer (GC-IPL) thickness in early glaucoma patients with parafoveal scotoma. Methods Fifty-seven eyes from 57 patients with glaucomatous optic neuropathy and parafoveal scotoma were analyzed using the standard automated perimetry (SAP) C10-2 test, the SAP C24-2 test, and the frequency doubling technology perimetry (FDT) C24-2 test. The correlation between the VF central sensitivity and the GC-IPL thickness from macular scans via optical coherence tomography was analyzed. Results The central sensitivity was $27.51{\pm}5.43dB$, $27.39{\pm}5.05dB$, and $22.09{\pm}5.08dB$ for SAP C24-2, SAP C10-2, and FDT C24-2, respectively. Mean GC-IPL thickness was $70.2{\pm}8.5{\mu}m$. Using regression analysis, the value of log $R^2$ between the logarithmic central sensitivity and GC-IPL thickness was 0.498, and the linear $R^2$ between the antilogarithmic central sensitivity and GC-IPL thickness in SAP C10-2 was 0.486, and both were statistically significant (p < 0.05). This relationship was stronger in early glaucoma patients compared to late glaucoma patients using SAP C10-2. Conclusions The structure-function relationship between GC-IPL thickness and central sensitivity was better with SAP C10-2, especially in early glaucoma patients, compared to other VF modalities.

A Comparison of Discriminating Powers between 13 Microsatellite Markers and 37 Single Nucleotide Polymorphism Markers for the Use of Pork Traceability and Parentage Test of Pigs (돼지 개체식별 및 친자감별을 위한 13 microsatellite marker와 37 single nucleotide polymorphism marker 간의 효율성 비교)

  • Lee, Jae-Bong;Yoo, Chae-Kyoung;Jung, Eun-Ji;Lee, Jung-Gyu;Lim, Hyun-Tae
    • Journal of agriculture & life science
    • /
    • v.46 no.5
    • /
    • pp.73-82
    • /
    • 2012
  • Allele information from the analysis of the 13 microsatellite (MS) markers, were classified into the $F_0$, $F_1$ and $F_2$ generations, and probabilities of the same individual emergency in each generation was calculated. As a result, the 13 MS markers showed an estimate of $3.84{\times}10^{-23}$ on the premise of the randomly mated group of $F_2$, which implies that the same individuals may emerge by the use of 37 kinds of SNP markers. In this study, the experimental pigs were intercross between only 2 breeds (Korean native pig and Landrace). In addition, the success rate of paternity tests was analyzed on the whole group, by the use of the 13 MS markers and 37 SNP markers. As regards the exclusionary power of the second parent ($PE_{pu}$), MS markers and SNP markers showed 0.97897 and 0.99149, respectively. In relation to the parent exclusion power of both parent (PE), MS markers and SNP markers showed 0.99916 and 0.99949, respectively. In the case of the estimate to identify parental candidates that had the highest probability ($PNE_{pp}$), the two showed 1.00000 all. The Korean pig industry tends to mass produce hogs with limited numbers of alleles in limited parents. Such being the case, there is a need to organize a marker, for which it is imperative to find markers with high efficiency and high economic feasibility of the characteristics of DNA markers, sample size, the accuracy and expenses of genotyping cost, the manageability of data and the compatibility among analysis systems.

Development of Automatic Loading Equipment of Seedling Tray for Automatic Process of Raising Seedlings in Plant Factory (식물공장 육묘공정 자동화를 위한 육묘트레이 자동적재장치 개발)

  • Park, Sang-Min;Min, Young-Bong;Lee, Gong-In;Kim, Dong-Ouk;Kang, Dong-Hyun;Moon, Sung-Dong
    • Journal of agriculture & life science
    • /
    • v.45 no.5
    • /
    • pp.105-113
    • /
    • 2011
  • This study was carried out to develop an automatic loading equipment that can load seedling trays on loading position of the seedling bed driving on enclosed-type rail installed for interconnecting each process of raising seedlings in plant factory. The experiment of transferring the seedling tray by monorail pusher was carried out to figure out the required transfer force and problems during push type device of transporting the plastic seedling trays, that has completed its sowing process, which are installed onto the board of different materials. From the results of this experiment, the loading equipment which can exactly load three of the seedling trays orderly on the loading position of the seedling bed was designed and made. When three sowed trays on every board are transferred by pusher with the speed is at 30 cm/s, the maximum peak transfer force with maximum overshooting at initial transient state and the maximum transfer force at stead state are were respectively 32.8 N, 29.4 N on rubber board, 29.7 N, 22.5 N on a wooden board, 26.9 N, 19.6 N on a acrylic board, and 27.6 N, 19.1 N on an iron board. Changes in the transfer force occurred its maximum at the moment when the pusher collided with the tray, after the collision gradually decreased until it became stable. When two or three trays placed it in order of widthwise are transferred, it is occurred the overlapping of the tray's external bracket. The developed automatic loading equipment with PLC controller did not make any operation error through 100 times of tests, its maximum seedling tray loading speed was 2 sec/tray and its maximum error of transferred location of the tray was 0.5 cm.