• Title/Summary/Keyword: testing dental implant

Search Result 61, Processing Time 0.025 seconds

Local tissue effects of various barrier membranes in a rat subcutaneous model

  • Naenni, Nadja;Lim, Hyun-Chang;Strauss, Franz-Josef;Jung, Ronald E.;Hammerle, Christoph H.F.;Thoma, Daniel S.
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.5
    • /
    • pp.327-339
    • /
    • 2020
  • Purpose: The purpose of this study was to examine the local tissue reactions associated with 3 different poly(lactic-co-glycolic acid) (PLGA) prototype membranes and to compare them to the reactions associated with commercially available resorbable membranes in rats. Methods: Seven different membranes-3 synthetic PLGA prototypes (T1, T2, and T3) and 4 commercially available membranes (a PLGA membrane, a poly[lactic acid] membrane, a native collagen membrane, and a cross-linked collagen membrane)-were randomly inserted into 6 unconnected subcutaneous pouches in the backs of 42 rats. The animals were sacrificed at 4, 13, and 26 weeks. Descriptive histologic and histomorphometric assessments were performed to evaluate membrane degradation, visibility, tissue integration, tissue ingrowth, neovascularization, encapsulation, and inflammation. Means and standard deviations were calculated. Results: The histological analysis revealed complete integration and tissue ingrowth of PLGA prototype T1 at 26 weeks. In contrast, the T2 and T3 prototypes displayed slight to moderate integration and tissue ingrowth regardless of time point. The degradation patterns of the 3 synthetic prototypes were similar at 4 and 13 weeks, but differed at 26 weeks. T1 showed marked degradation at 26 weeks, whereas T2 and T3 displayed moderate degradation. Inflammatory cells were present in all 3 prototype membranes at all time points, and these membranes did not meaningfully differ from commercially available membranes with regard to the extent of inflammatory cell infiltration. Conclusions: The 3 PLGA prototypes, particularly T1, induced favorable tissue integration, exhibited a similar degradation rate to native collagen membranes, and elicited a similar inflammatory response to commercially available non-cross-linked resorbable membranes. The intensity of inflammation associated with degradable dental membranes appears to relate to their degradation kinetics, irrespective of their material composition.

Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins

  • Asar, Neset Volkan;Albayrak, Hamdi;Korkmaz, Turan;Turkyilmaz, Ilser
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.241-247
    • /
    • 2013
  • PURPOSE. To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. MATERIALS AND METHODS. Fifty acrylic resin specimens were fabricated for each test and divided into five groups. Group 1 was the control group and Group 2, 3, 4 and 5 (test groups) included a mixture of 1% $TiO_2$ and 1% $ZrO_2$, 2% $Al_2O_3$, 2% $TiO_2$, and 2% $ZrO_2$ by volume, respectively. Rectangular unnotched specimens ($50mm{\times}6.0mm{\times}4.0mm$) were fabricated and drop-tower impact testing machine was used to determine IS. For FT, compact test specimens were fabricated and tests were done with a universal testing machine with a cross-head speed of 5 mm/min. For WSP and WSL, disc-shaped specimens were fabricated and tests were performed in accordance to ISO 1567. ANOVA and Kruskal-Wallis tests were used for statistical analyses. RESULTS. IS and FT values were significantly higher and WSP and WSL values were significantly lower in test groups than in control group (P<.05). Group 5 had significantly higher IS and FT values and significantly lower WSP values than other groups (P<.05) and provided 40% and 30% increase in IS and FT, respectively, compared to control group. Significantly lower WSL values were detected for Group 2 and 5 (P<.05). CONCLUSION. Modification of heat-cured acrylic resin with metal oxides, especially with $ZrO_2$, may be useful in preventing denture fractures and undesirable physical changes resulting from oral fluids clinically.

Recurrent ST segment elevations in a patient with asymptomatic early repolarization during head and neck surgery: implications of vasospastic angina

  • Park, Se-Ung;Kim, Sung-Hoon;Kwon, Hye-Mee;Koh, Gi-Ho;Nam, Gi-Byoung;Karm, Myong-Hwan;Kim, Wook-Jong;Ku, Seung-Woo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.3
    • /
    • pp.189-193
    • /
    • 2018
  • A 57-year-old woman scheduled for cochlear implant removal exhibited preoperative electrocardiographic findings of early repolarization (ER). Four episodes of transient ST segment elevations during surgery raised suspicion for vasospastic angina (VA). In the post-anesthetic care unit, the patient complained of chest discomfort and received sublingual nitroglycerin with uncertain effect. The patient refused to proceed with postoperative invasive coronary angiography, resulting in inconclusive diagnosis. Intraoperative circumstances limit the diagnosis of VA, which emphasizes the need for further testing to confirm the diagnosis. When VA is suspected in patients with underlying ER, it is reasonable to consider invasive examination to establish the diagnosis and prevent recurrence of VA. If ST changes are observed during surgery in patients with preoperative ER, careful monitoring is recommended. Due to general anesthesia, the absence of patient symptoms limits the definitive diagnosis of those with suspected VA. Therefore, additional postoperative surveillance is recommended.

Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment (임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교)

  • Choi, Jae-Won;Chae, Sung-Ki;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.173-180
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles. Materials and methods: The newly developed attachment and the commercially available attachment were investigated: ADD-Lock (AL), Locator blue (LB). Two fixtures were placed parallel to each other on the custom lower mounting, and patrix of each attachment was fixed to the fixture. Also, the matrix of each attachment was placed on the opposing upper mounting. A universal testing machine was used to measure the retentive force during initial, 100, 250, 500, 1000, 2000, and 2500 repeated insertion/removal cycles. Wear and deformation of the attachment s were observed by scanning electron microscopy (SEM). Mann-Whitney U test (α=.05) and wilcoxon signed-rank test (α=.05) were performed to compare retentive force between each group and before and after 2500 repeated insertion/removal cycles. Results: In terms of initial retentive force and retentive force after 2500 repeated insertion/removal cycles, the AL group (15.24 ± 1.46 N and 9.74 ± 1.16 N) showed significantly smaller values than the LB group (43.53 ± 12.39 N and 22.99 ± 4.77 N) (P<.05). Also, in the loss of retentive force, the AL group (5.50 ± 1.08 N, 36.08%) showed a smaller value than the LB group (20.54 ± 11.89 N, 47.19%) (P<.05). Based on SEM analysis, The AL group showed noticeable wear and deformation in the patrix and the LB group in the matrix. Conclusion: Locator showed a higher initial retentive force than newly developed attachment, while the loss of retentive force was also higher. Both additional attachments are considered to have sufficient retentive force after repeated insertion/removal cycles.

Knowledge and attitudes of Korean dentists towards human immunodeficiency virus/acquired immune deficiency syndrome

  • Park, Jung-Chul;Choi, Seong-Ho;Kim, Yong-Tae;Kim, Sun-Jong;Kang, Hee-Jung;Lee, Jong-Ho;Shin, Seung-Chul;Cha, Young-Joo
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Infection with human immunodeficiency virus (HIV) remains a major global threat, and although the prevalence is comparatively still very low, the number of HIV-positive Koreans is increasing. However, there are no official guidelines as to how to treat people living with HIV/acquired immunodeficiency syndrome (AIDS) (PLWHA) or how to screen for potentially infectious people. This study assessed the level of knowledge and attitudes of dentists in Korea toward PLWHA, and their attitudes to screening patients for HIV infections. Methods: A cross-sectional prospective survey targeting dentists working in Korea was conducted using a self-administered questionnaire. Results: A satisfactory level of knowledge about HIV/AIDS and a relatively positive attitude toward PLWHA was found. Most of the respondents preferred rapid HIV testing using oral fluid as a specimen. The general attitude of dentists toward HIV/AIDS is sufficiently positive to enable provision of the best treatment to the patients in need. Conclusions: Most of the dentists require HIV testing in dental clinics. In spite of their needs, there are several obstacles. It is hoped that financial considerations and official legal requirements related to HIV testing strategies will be considered.

In vitro evaluation of the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with composite fillings after cyclic loading

  • Sadighpour, Leyla;Geramipanah, Farideh;Allahyari, Somayeh;Sichani, Babak Fallahi;Fard, Mohamd Javad Kharazi
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.278-284
    • /
    • 2014
  • PURPOSE. There is insufficient data regarding the durability of porcelain laminate veneers bonded to existing composite fillings. The aim of the present study was to evaluate the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with existing composite fillings. MATERIALS AND METHODS. Thirty maxillary central incisors were divided into three groups (for each group, n=10): intact teeth (NP), teeth with class III composite fillings (C3) and teeth with class IV cavities (C4). Porcelain laminate veneers were made using IPS-Empress ceramic and bonded with Panavia F2 resin cement. The microleakage of all of the specimens was tested before and after cyclic loading ($1{\times}10^6$ cycles, 1.2 Hz). The fracture resistance values (N) were measured using a universal testing machine, and the mode of failure was also examined. The statistical analyses were performed using one-way ANOVA and Tukey post hoc tests (${\alpha}=.05$). RESULTS. There was a significant difference in the mean microleakage of group C4 compared with group NT (P=.013). There was no significant difference in the fracture loads among the groups. CONCLUSION. The microleakage and failure loads of porcelain laminate veneers bonded to intact teeth and teeth with standard class III composite fillings were not significantly different.

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

Comparison of fatigue fracture strength by fixture diameter of mini implants (미니 임플란트 직경에 따른 피로파절강도의 비교 연구)

  • Heo, Yu-Ri;Son, Mee-Kyoung;Kim, Hee-Jung;Choe, Han-Cheol;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.156-161
    • /
    • 2012
  • Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at $30^{\circ}$ from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was $101.5{\pm}14.6N$, $149{\pm}6.1N$ and $276.0{\pm}13.4N$, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until $2{\times}10^6$ cycles at diameter 2.0 mm, and until $5{\times}10^6$ cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used.

Reasonable necessity of preoperative laboratory tests in office-based oral and maxillofacial surgery

  • Mi Hyun Seo;Mi Young Eo;Kezia Rachellea Mustakim;Buyanbileg Sodnom-Ish;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.3
    • /
    • pp.142-147
    • /
    • 2023
  • Objectives: As medical history before surgery is often based on patient reporting, there is the possibility that patients intentionally hide underlying diseases or that dentists cannot recognize abnormal health states. Therefore, more professional and reliable treatment processes are needed under the Korean dental specialist system. The purpose of this study was to elucidate the necessity of a preoperative blood testing routine prior to office-based surgery under local anesthesia. Patients and Methods: Preoperative blood lab data for 5,022 patients from January 2018 to December 2019 were assembled. Study participants were those who underwent extraction or implant surgery under local anesthesia at Seoul National University Dental Hospital. Preoperative blood tests included complete blood count (CBC), blood chemistry, serum electrolyte, serology, and blood coagulation data. Values outside of the normal range were considered an "abnormality," and the percentage of abnormalities among the total number of patients was calculated. Patients were divided into two groups based on the presence of underlying disease. The rates of abnormalities in the blood tests were compared between groups. Chi-square tests were performed to compare data from the two groups, and P<0.05 was considered statistically significant. Results: The percentages of males and females in the study were 48.0% and 52.0%, respectively. Of all patients, 17.0% (Group B) reported known systemic disease, while 83.0% (Group A) reported no specific medical history. There were significant differences between Groups A and B in CBC, coagulation panel, electrolytes, and chemistry panel (P<0.05). In Group A, the results of blood tests that required a change in procedure were identified even though the proportion was very small. Conclusion: Preoperative blood tests for office-based surgery can detect underlying medical conditions that are difficult to identify from patient history alone and can prevent unexpected sequelae. In addition, such tests can result in a more professional treatment process and build patient confidence in the dentist.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.