• 제목/요약/키워드: testing and calibration

검색결과 241건 처리시간 0.032초

Shack-Hartmann 파면분석기와 점광원을 이용한 DVD 픽업 렌즈의 수차 측정 (Wavefront Aberration Measurement of DVD pick-up lenses with a Shack-Hartmann Sensor and a Point Source)

  • 강동원;이진석;한재원
    • 정보저장시스템학회논문집
    • /
    • 제3권3호
    • /
    • pp.135-138
    • /
    • 2007
  • Using a Shack-Hartmann sensor and sub-wavelength sized pinhole point source, we develope an optical testing system that measures the wavefront error of high numerical aperture and small sized optical components. The subwavelength sized pinhole generates perfect spherical waves with large diffraction angle and this makes possible to test high numerical aperture optics. The Shack-Hartmann sensor reconstructs the wavefront and calculates the aberrations. We make a home-made reference plane wave source which generates nearly perfect plane waves and the calibration with this plane source gives the overall uncertainty of the optical testing system 0.010 $\lambda$ rms.

  • PDF

다축 시뮬레이터의 구동 소프트웨어 개발 및 보정에 관한 연구 (A Study on Operating Software Development and Calibration of Multi-Axis Simulation)

  • 정상화;류신호;신형성;김상석;김종태;박용래
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.141-141
    • /
    • 2000
  • In the recent day, fatigue life prediction techniques play a major role in the design of components in th ground vehicle industry. Full scale durability testing in the laboratory is an essential of any fatigue life evaluation of components or structure of the automotive vehicle. Component testing is particularly important in today's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, multi-axis durability testing simulator is used to car교 out the fatigue test. In this paper, the operation software for simultaneously driving 3-axis simulator is developed and the real-time signals of input-output data are displayed in window of PC. Moreover, the displacements and the loads of 3-axis actuators are calibrated separately and the operating characteristics of the actuators are evaluated.

  • PDF

PD Diagnosis on 22.9kV XLPE Underground Cable using Ultra-wideband Sensor

  • Lwin, Kyaw-Soe;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.422-429
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band (UWB) sensor design and study of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with the newly designed UWB sensor. In this study, we designed a new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both the low frequency and high frequency band of the partial discharge signal. Experiments of offline PD testing on medium voltage (22.9kV) underground cable mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative tests, the calibration signal injection test provided with the conventional IEC 60270 method and high voltage injection testing are included.

Bayesian Hypothesis Testing for Homogeneity of the Shape Parameters in the Gamma Populations

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제18권4호
    • /
    • pp.1191-1203
    • /
    • 2007
  • In this paper, we consider the hypothesis testing for the homogeneity of the shape parameters in the gamma distributions. The noninformative priors such as Jeffreys# prior or reference prior are usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. So we propose the objective Bayesian testing procedure for the homogeneity of the shape parameters based on the fractional Bayes factor and the intrinsic Bayes factor under the reference prior. Simulation study and a real data example are provided.

  • PDF

마약남용자 11명의 타액 중 메스암페타민의 분석 (Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers)

  • 김은미;이주선;최혜영;최화경;정희선
    • 약학회지
    • /
    • 제52권6호
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.

STS 316L 교정시험편을 이용한 재가열기 튜브의 와전류신호와 초음파 IRIS 신호 특성 (Eddy Current and Ultrasonic IRIS Signal Characteristics of Reboiler Tube by Using STS 316L Calibration Specimen)

  • 탁경주;김병일;국진선
    • 비파괴검사학회지
    • /
    • 제32권1호
    • /
    • pp.56-63
    • /
    • 2012
  • 본 연구에서는 가공된 오스테나이트계 STS 316L ASME 표준 교정시험편을 이용하여 튜브 두께 감소율과 잔존두께에 대한 와전류 신호와 IRIS 신호특성을 비교하여 리보일러 튜브의 현장 적용성을 평가하였다. 그 결과 두께감소율의 경우 와전류탐상검사는 $20%{\times}4$ 평저공, 10% 외면 그루브, IRIS는 80%홈, 10%외면 그루브에서 ${\pm}15%$ 이상의 편차가 발생하였다. 잔존두께의 경우 와전류탐상은 측정치가 모두 허용범위를 만족하였으나, IRIS는 80% 인공홈에서 ${\pm}15%$ 이상의 편차가 발생하였다. 따라서 와전류탐상검사 후 의사지시에 대한 해석, 두께감소율 측정을 위해 IRIS를 수행한다면 신뢰성이 향상될 것으로 판단된다.

공내재하시험기를 이용한 미소변형 전단탄성계수 측정 (Measurement of Small-Strain Shear Modulus Using Pressuremeter Test)

  • 김동수;박재영;이원택
    • 한국지반공학회지:지반
    • /
    • 제13권4호
    • /
    • pp.109-120
    • /
    • 1997
  • 공용하중 상태에서 지반이 경험하는 변형률 크기는 0.1~1% 미만임이 밝혀지고 있다. 변형특성을 보다 엄밀히 평가하기 위하여는 미소변형률 영역에서의 신뢰성 있는 변형측정이 가능한 현장시험기기의 개발이 필요하다. 본 연구의 목적은 공내째하시험기(PMT)를 사용하여 지반의 미소변형률 전단탄성계수를 측정하는 것이다. 공내재하시험에서 시추공 설치에 따른 주위 지반의 교란효과를 제거하기 위하여 초기 하중재하단계가 아닌 역재하-재재하 단계에서 PMT 주위지 반의 응력상태 및 변형률 크기를 고려하여 미소변형률 잔단탄성계수를 결정하였다. 실내 토조에서 성형한 모래시료와 화강풍화토 현장지반에서 시험을 수행하였으며,시험결과로부터 본 연구 에서 사용한 PMT시험은 변형률 크기 10-2%~0.5% 범위에서 신뢰성 있는 전단탄성계수 측정이 가능하였다. 또한 변형률 크기를 고려하여 다른 실내외시험에서 결정된 전단탄성계수와 비교 하면 서로 잘일치하는 결과를 얻을 수 있었다.

  • PDF

대기 중 온실가스 농도 관측 장비 성능 비교 검증 (Assessment of Atmospheric Greenhouse Gas Concentration Equipment Performance)

  • 박채린;정수종;정승현;이정일;김인선;임철수
    • 대기
    • /
    • 제33권5호
    • /
    • pp.549-560
    • /
    • 2023
  • This study evaluates three distinct observation methods, CRDS, OA-ICOS, and OF-CEAS, in greenhouse gas monitoring equipment for atmospheric CO2 and CH4 concentrations. The assessment encompasses fundamental performance, high-concentration measurement accuracy, calibration methods, and the impact of atmospheric humidity on measurement accuracy. Results indicate that within a range of approximately 500 ppm, all three devices demonstrate high accuracy and linearity. However, beyond 1000 ppm, CO2 accuracy sharply declines (84%), emphasizing the need for caution when interpreting high-concentration CO2 data. An analysis of calibration methods reveals that both CO2 and CH4 measurements achieve high accuracy and linearity through 1-point calibration, suggesting that multi-point calibration is not imperative for precision. In dynamic atmospheric conditions with significant CO2 and CH4 concentration variations, a 1-point calibration suffices for reliable data (99% accuracy). The evaluation of humidity impact demonstrates that humidity removal devices significantly reduce air moisture levels, yet this has a negligible effect on dry CO2 concentrations (less than 0.5% relative error). All three observation method instruments, which have integrated humidity correction to calculate dry CO2 concentrations, exhibit minor sensitivity to humidity removal devices, implying that additional removal devices may not be essential. Consequently, this study offers valuable insights for comparing data from different measurement devices and provides crucial information to consider in the operation of monitoring sites.

토양의 총인산과 유효인산함량을 측정하기 위한 근적외 기술의 이용 (Use of NIR Technique for Determination of Total Phosphorus and Available Phosphorus in Korean Soils)

  • 유관식;박진숙
    • 한국토양비료학회지
    • /
    • 제41권1호
    • /
    • pp.50-54
    • /
    • 2008
  • 근적외선스펙트로메타는 토양의 성분을 측정하는 새로운 기술로 발전하고 있다. 작물이 요구하는 토양의 인산 함량을 측정하는 데는 시간이 많이 소요되며, 침출액과 침출조건에 따라서 다르기 때문에 어려운 성분이다. 그러나 근적외선 방법을 이용하여 표준곡선을 정확하게만 만들어, 표준곡선 작성 시 Wiliams의 상관계수안내를 이용하면 상관계수의 수치에 따라서 토양의 총인산과 유효인산을 측정하는데 간편하게 이용할 수 있다. 또한 근적외 기술은 정밀도를 향상하면 포장 현지에서의 토양검정에도 쉽게 이용할 수 있는 쉬운 기술로 생각된다.

실내 및 포장가속시험를 이용한 아스팔트 혼합물의 소성변형 모형 개발 (Development of Rutting Model for Asphalt Mixtures using Laboratory and Accelerated Pavement Testing)

  • 이상염;이현종;허재원;박희문
    • 한국도로학회논문집
    • /
    • 제10권4호
    • /
    • pp.79-89
    • /
    • 2008
  • 포장 공용성 모델은 역학적-경험적 포장설계법에서 포장의 수명을 결정하기 위한 가장 중요한 인자이다. 한국 포장연구 프로그램의 일환으로 한국형 포장설계법이 역학적-경험적 방법에 근거하여 현재 개발중에 있다. 본 연구에서는 포장 공용성모델중 아스팔트 혼합물의 영구변형 예측모델을 삼축압축 반복재하시험을 이용하여 개발하였다. 본 시험은 다양한 아스팔트 혼합물에 대하여 온도와 공극률을 변화시켜 하중재하 횟수에 따른 혼합물의 영구변형 특성을 조사하였으며, 본 시험결과를 이용하여 예측모델의 계수값을 결정하였다. 영구변형 예측모델의 계수값은 포장가속시험결과를 토대로 다양한 혼합물에 대한 시험결과를 이용하여 깊이에 따른 전단응력의 변화를 고려한 통합적인 소성변형 모델계수값을 정하는 것보다 혼합물의 종류에 따른 모델계수를 산정하는 것이 보다 정확한 결과를 예측할 것으로 판단된다.

  • PDF