• Title/Summary/Keyword: test-strip

Search Result 444, Processing Time 0.027 seconds

The Fluidity of the Recycled Thermoplastic Elastomer on the Injection Molding Process (사출성형공정에서 엘라스토머 재생재의 유동성)

  • No, B.S.;Han, S.R.;Jeong, Y.D.
    • Transactions of Materials Processing
    • /
    • v.16 no.4 s.94
    • /
    • pp.271-275
    • /
    • 2007
  • These days, recycling of plastic material has become a major issue due to the landfills and environmental problem. This study investigates the fluidity of thermoplastic vulcanizate(TPV), which can be used for an automobile part such as a weather strip, in order to replace ethylene propylene rubber(EPDM). Injection molding experiments with the spiral flow test mold and panel cover mold are conducted to examine the fluidity of TPV during injection molding. It is found out that the recycled TPV's flow length is a little bit longer than the virgin TPV. However, the filling weight for a panel cover parts by a recycled TPV is almost the same as that by a virgin TPV.

A Study on the Hydraulic Automatic Gauge Control System of Adaptive Mass Flow Method (Adaptive mass flow method 유압압하식 자동 두께제어 장치에 관한 연구)

  • 윤순현;김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.101-107
    • /
    • 1996
  • This test was performed on the hydraulic automatic gauge control(AGC) system of adaptive mass flow method. Fundamental purpose of this study are performance evaluation of this AGC system under the actual rolling condition. It was concluded that the response of AGC system depends on the dynamic characteristics of a reel motor or roll position. The test results are as follows : 1) The control method of reel motor current is better than than of the roll position as AGC system. 2) The more steel strip thickness of delivery side is thick, the larger the gauge deviation is large, and the more it is thin, the larger the gauge deviation rate is large. 3) Because the gauge deviation is large at acceleration and deceleration speed than steady speed, so AGC system is better to adopt over 50m/min. By applying this AGC system, not only the accurary in strip thickness were improved but also productivity was improved dramatically.

  • PDF

Experimental investigation of the effects of pipe location on the bearing capacity

  • Bildik, Selcuk;Laman, Mustafa
    • Geomechanics and Engineering
    • /
    • v.8 no.2
    • /
    • pp.221-235
    • /
    • 2015
  • A series of laboratory model tests were conducted to investigate the effects of buried pipes location on the bearing capacity of strip footing in cohesionless soil. The variables examined in the testing program include relative density of the sand, loading rate of tests, burial depths of pipe and horizontal distance of pipe to footing. The test results showed a significant increase in bearing capacities when embedment ratio of pipe and horizontal distance of pipe to footing were increased. Based on the test results, it can be concluded that the location of pipes and relative density of sand are main parameters that affect the bearing capacity of strip footing. However, loading rate has not considerable effect on bearing capacity.

Evaluation of Strain Distribution and Pullout Strength based on Width and Horizontal Spacing of Geosynthetic Strip (띠형 섬유보강재의 폭과 설치간격에 따른 변형률 분포 및 인발강도 특성 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.2
    • /
    • pp.39-47
    • /
    • 2012
  • This paper describes large-scale pullout test results of geosynthetic strip, which can be applied in reinforced earth wall with block-type wall facing. The pullout tests are conducted to evaluate the strain distribution, the induced pullout force and the pullout strength. The maximum pullout force is appeared regardless of reinforcement width and normal stress when end displacement is less than 15 mm. The pullout behavior based on horizontal spacing of reinforcement was similar in relationship between pullout force and end displacement. The strain distribution and pullout force distribution of the geosynthetic strip are concentrated in the front part of reinforcement, and it appeared clearly in higher normal stress condition This means that the pullout behavior of geosynthetic strip is affected by the bond between soil and friction resistance reinforcement according normal stress. Therefore, the pullout resistance design is reasonable when pullout behavior of geosynthetic strip should be evaluated by effective length considering tensile characteristic.

Effects of Cryogenic Temperature on Wear Behavior of 22MnB5 Under Cold Stamping (극저온이 22MnB5강의 냉간 스탬핑 마모에 미치는 영향)

  • Ji, Min-Ki;Noh, Yeonju;Kang, Hyun-Hak;Jun, Tea-Sung
    • Tribology and Lubricants
    • /
    • v.38 no.6
    • /
    • pp.241-246
    • /
    • 2022
  • This paper presents the effects of cryogenic temperature on the wear behavior of 22MnB5 blank under cold stamping. After immersing the blank in liquid nitrogen (LN2) for 10 min, a strip drawing test was performed within 10 s. The hardness was measured using the Rockwell hardness test, which increased from 165 HV at 20℃ to 192 HV at cryogenic temperature. The strip drawing test with 22MnB5 blank and SKD61 tool steel shows that for the different wear mechanisms on the tool surface with respect to temperature; adhesive wear is dominant at 20℃, but abrasive wear is the main mechanism at cryogenic temperature. As the friction test is repeated, sticking gradually increases on the tool surface at 20℃, whereas the scratch increases at cryogenic temperature. For the friction behavior, the friction coefficient rapidly increases when adhesive wear occurs, and it occurs more frequently at 20℃. The results for nanoindentation near the worn blank surface indicate a difference of 1.3 GPa at 20℃ and 0.8 GPa at cryogenic temperature compared to the existing hardness, indicating increased deformation by friction at 20℃. This occurs because thermally activated energy available to move the dislocation decreases with decreasing temperature.

Implementation of Urinalysis Service Application based on MobileNetV3 (MobileNetV3 기반 요검사 서비스 어플리케이션 구현)

  • Gi-Jo Park;Seung-Hwan Choi;Kyung-Seok Kim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.41-46
    • /
    • 2023
  • Human urine is a process of excreting waste products in the blood, and it is easy to collect and contains various substances. Urinalysis is used to check for diseases, health conditions, and urinary tract infections. There are three methods of urinalysis: physical property test, chemical test, and microscopic test, and chemical test results can be easily confirmed using urine test strips. A variety of items can be tested on the urine test strip, through which various diseases can be identified. Recently, with the spread of smart phones, research on reading urine test strips using smart phones is being conducted. There is a method of detecting and reading the color change of a urine test strip using a smartphone. This method uses the RGB values and the color difference formula to discriminate. However, there is a problem in that accuracy is lowered due to various environmental factors. This paper applies a deep learning model to solve this problem. In particular, color discrimination of a urine test strip is improved in a smartphone using a lightweight CNN (Convolutional Neural Networks) model. CNN is a useful model for image recognition and pattern finding, and a lightweight version is also available. Through this, it is possible to operate a deep learning model on a smartphone and extract accurate urine test results. Urine test strips were taken in various environments to prepare deep learning model training images, and a urine test service application was designed using MobileNet V3.

Electromigration Behavior in the 63Sn-37Pb Solder Strip (63Sn-37Pb 솔더 스트립에서의 Electromigration 거동)

  • Lim Seung-Hyun;Choi Jae-Hoon;Oh Tae-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.53-58
    • /
    • 2004
  • To facilitate the observation of the electromigration of 63Sn-37Pb eutectic solder, strip-type samples were fabricated by solder evaporation. The electromigration test for the 63Sn-37Pb solder strip was conducted at temperatures of $80{\sim}150^{\circ}C$ and the current densities of $1{\times}10^4{\sim}1{\times}10^5\;A/cm^2$. With increasing temperature and the current density, mean-time-to-failure(MTTF) decreased due to the formation of hillock and void in the solder strip. The activation energy for the electromigration in the 63Sn-37Pb solder strip was analyzed as $0.16{\sim}0.5\;eV$ using Black's equation.

  • PDF

Development of Urine Strip for Detection of Leukocytes in Urine using Peroxidase (과산화효소를 이용한 백혈구 측정용 뇨 검사지 제조에 관한 연구)

  • 송은영;이홍수;김희정;김종완;최인성;변시명;정태화
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.199-209
    • /
    • 1996
  • A new test strip to detect leukocytes using the myeloperoxidase in urine was developed. The reagent strip contains tetramethylbenzine, glucose and glucose oxidase. The detection limit was between 10 cells per 1$\mu$l urine(5 cells/hpf), showing greenish yellow color in the range of 10-25 cells/$\mu$l, green color in the range of 75-250 cells/$\mu$l, greenish blue color in the range of 500 cells/$\mu$l. The result can be obtained within two minute. The performance of the new method was evaluated by comparing the results of microscopic examination and other commercial products. Good correlations were shown between the values obtained by our urine strip and those by other commercial products with 172 urine samples. The results were proven that new methods were useful as primary screening reagents to detect leukocytes in urine.

  • PDF

Verification of Utility of Simple Mensuration of Cl- from Urine to Estimate the Amount of Sodium Intake (나트륨 섭취량 추정을 위한 소변 중 Cl-의 간이적 측정방법의 유용성 검증)

  • Lee, Sung-Ho;Lee, Chae-Joon;Ju, Sung-Mi;Lee, Hyun-Joo;Ra, Wang-Yeon;Kim, Soon-Ok
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.1
    • /
    • pp.27-32
    • /
    • 2016
  • The purpose of this study was to measure concentrations of $K^+$, $Na^+$, $Cl^-$ by ionometer with check salt strip, simple salimeter and Ion-selective electrode (ISE) and compare the results of each mensuration; furthermore, the possibility of inferring the $Na^+$ concentration from $Cl^-$ concentration of urine and the impact of $K^+$ on the concentration of each ion was examined. The results showed that ISE determined $Na^+$ and $Cl^-$ concentrations in the urine are highly interrelated (R=0.9039); in addition, concentrations of $Cl^-$, measured with strip and ISE from urine are highly interrelated (R=0.9338). The concentration of $Na^+$ in urine, inferred by measuring $Cl^-$ concentration with strip, has a high relationship (R=0.8580) with the concentration of $Na^+$ in urine, measured by ISE. The results of our study will increase awareness of $Na^+$ intake and the utility of check salt strip, as well as the possibility of inferred $Na^+$ concentration from measures of $Cl^-$ concentration as a screening test for reducing sodium intake.

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

  • Shokri, Abbas;Eskandarloo, Amir;Noruzi-Gangachin, Maruf;Khajeh, Samira
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.58-67
    • /
    • 2015
  • Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.