• Title/Summary/Keyword: test strip

Search Result 444, Processing Time 0.03 seconds

Experimental study on improving bamboo concrete bond strength

  • Mali, Pankaj R.;Datta, Debarati
    • Advances in concrete construction
    • /
    • v.7 no.3
    • /
    • pp.191-201
    • /
    • 2019
  • Bamboo concrete bond behaviour is investigated through pullout test in this work. The bamboo strip to be used as reinforcement inside concrete is first treated with chemical adhesive to make the bamboo surface impermeable. Various surface coatings are explored to understand their water repellant properties. The chemical action at the bamboo concrete interface is studied through different chemical coatings, sand blasting, and steel wire wrapping treatment. Whereas mechanical action at the bamboo concrete interface is studied by developing mechanical interlock. The result of pullout tests revealed a unique combination of surface treatment and grooved bamboo profile. This combination of surface treatment and a grooved bamboo profile together enhances the strength of bond. Performance of a newly developed grooved bamboo strip is verified against equivalent plain rectangular bamboo strip. The test results show that the proposed grooved bamboo reinforcement, when treated, shows highest bond strength compared to treated plain, untreated plain and untreated grooved bamboo reinforcement. Also, it is observed that bond strength is majorly influenced by the type of surface treatment, size and spacing of groove. The changes in bamboo-concrete bond behavior are observed during the experimentation.

Determination of Double-K Fracture Parameters of Concrete Using Split-Tension Cube: A Revised Procedure

  • Pandey, Shashi Ranjan;Kumar, Shailendra;Srivastava, A.K.L.
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.2
    • /
    • pp.163-175
    • /
    • 2016
  • This paper presents a revised procedure for computation of double-K fracture parameters of concrete split-tension cube specimen using weight function of the centrally cracked plate of finite strip with a finite width. This is an improvement over the previous work of the authors in which the determination of double-K fracture parameters of concrete for split-tension cube test using weight function of the centrally cracked plate of infinite strip with a finite width was presented. In a recent research, it was pointed out that there are great differences between a finite strip and an infinite strip regarding their weight function and the solution of infinite strip can be utilized in the split-tension specimens when the notch size is very small. In the present work, improved version of LEFM formulas for stress intensity factor, crack mouth opening displacement and crack opening displacement profile presented in the recent research work are incorporated. The results of the double-K fracture parameters obtained using revised procedure and the previous work of the authors is compared. The double-K fracture parameters of split-tension cube specimen are also compared with those obtained for standard three point bend test specimen. The input data required for determining double-K fracture parameters for both the specimen geometries for laboratory size specimens are obtained using well known version of the Fictitious Crack Model.

Evaluation of the proximal contact and comparison of methods for measuring in normal dentition (건강한 자연치열에서 인접면 접촉의 평가 및 측정방법에 따른 비교분석)

  • Ji-Eun Kim;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.198-203
    • /
    • 2023
  • Purpose. The aim of this study was to evaluate the proximal contact with a dental floss compared to a celluloid strip and a metal strip in normal dental arch and investigate what the most effective method for measuring is. Materials and methods. The subjects of this study was consisted with 20 healthy adults (10 males and 10 females) who had normal dentition. A dentist with more than 5 years of clinical experience evaluated the proximal contacts using a dental floss method, a celluloid strip method, and a metal strip method. Statistical analysis were performed by the use of Mann-Whitney U test. A P-value < .05 was considered statistically significant in all analysis. In addition, in the evaluation of proximal contact using a dental floss, the measurement of proximal contact using a celluloid strip and a metal strip was compared. Results. 80 % of all proximal contact was proper. Proper proximal contact was observed at the posterior area compared to the anterior area (P < .05). And male had proper proximal contact at the anterior area, female had proper proximal contact at the posterior area (P < .05). The consistency analysis between the results of the celluloid strip and the metal strip experiment on the results obtained from the floss using the consistency scale Kappa index shows that using celluloid strip is more advantageous than using the metal strip. Conclusion. Only 80% of all proximal contact was proper. Using celluloid strips with various thickness for evaluating of proximal contact is considered to be helpful for accurate measuring of proximal contact.

Pull-Out Properties of Steel Strip Reinforcement with Transverse Steel Bar (지지부재를 설치한 띠형 강판보강재의 인발마찰 특성 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Ju, Jae-Woo;Park, Jong-Beom
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.3
    • /
    • pp.31-37
    • /
    • 2007
  • A steel strip reinforcement for the reinforced earth structures was recently developed to substitute the existing ribbed steel strip reinforcement. The developed reinforcement consists of the punched steel strip having dimension of 65mm width and 4.5mm thickness and the transverse steel bar for increasing bearing resistance. The punched steel strip has holes of 11mm diameter in every 50cm spacing with 2mm rising around perimeter of the holes. A series of shear friction tests and pull-out tests were carried out to evaluate the friction properties of the developed reinforcement. The results of these tests show that pull-out resistance of the developed reinforcement was significantly increased when the transverse steel bars are installed in the punched steel strip.

  • PDF

Preparation and Characterization of Periodontal Chitosan Strip Containing Doxycycline Nanoparticle (독시사이클린 나노입자가 함유된 치주용 키토산 스트립의 제조 및 특성)

  • Song, Kyung-Suk;Yang, Jae-Heon;Kim, Young-Il;Chung, Kyu-Ho
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.4
    • /
    • pp.233-239
    • /
    • 2001
  • Local drug delivery by using biocompatible polymers has been developed in the treatment of periodontitis for many years. In the field of dental therapy, doxycycline is usually a first choice because of its broad-spectrum antibiotic activity. The strip releases antibiotics for a week, and the polymer should be degradable after a week. In this study, we prepared and evaluated the chitosan strips and nanoparticle strips containing doxycycline hydrochloride, and studied their antiacterial activity, dissoultion, and degrability in vitro. The weight of cast strip containing a 5 mg of doxycycline hydrochloride and a 45 mg of chitosan polymer was $57.67{\pm}0.17\;mg$. The release rate of doxycycline hydrochloride from the strip was measured by HPLC. The drug released from chitosan strip and nanoparticle strip was shown to be $50\;{\mu}g/mL$ in first 24 hours. In antibacterial test showed growth inhibitory activity after 24 hrs anaerobic incubation. In vitro degradability showed demolished weight of $93.74{\pm}0.08%$ chitosan strip, $82.48{\pm}1.29%$ chitosan nanoparticle strip, $2.47{\pm}1.99%$ polycarprolactione strip (control). These results showed that, with this doxycycline hydrochloride strip, it is feasible to obtain a sustained release of the drug within the periodontal pocket for seven days which may be improve for local drug delivery system for treatment of periodontal disease.

  • PDF

Feasibility Study on the Use of Liposomes for Detecting Food-borne Pathogenic Bacteria (식중독 세균 검출에 있어서 리포좀의 이용 가능성)

  • 김명희;김왕준;신원선;손동화;차성관
    • Food Science of Animal Resources
    • /
    • v.23 no.3
    • /
    • pp.278-283
    • /
    • 2003
  • Feasibility tests on using liposomes for detecting food-borne pathogenic bacteria were studied with E. coli 0157:H7 as a model analyte. lmmunoliposomes, whose surface was conjugated with anti-E. coli 0157:H7 IgG and which encapsulated the marker dye, sulforhodamine B, were used for the detection label. Among the feasibility tests, the first test was to use a test-strip on which antibodies to anti-E. coli O157:H7 IgG were immobilized. In this format, immunoliposomes that did not bind to E. coli O157:H7 in sample were captured and then exhibited a visible signal which was inversely related with the number of E. coli O157:H7 in sample. The second test was a direct liposome assay followed by immunomagnetic separation. In this format, immunoliposomes which were bound to E. coli O157:H7 were lysed with detergent and produced a signal which was proportionally related with the number of E. coli O157:H7 in sample. The results from both formats indicate that liposomes can be utilized as a detection label.

Precise width control through the width spread compensation in hot strip mill (열간압연시 폭퍼짐 보상을 통한 폭정밀도 개선연구)

  • 천명식;이준정;문영훈
    • Transactions of Materials Processing
    • /
    • v.8 no.2
    • /
    • pp.200-207
    • /
    • 1999
  • To increase dimensional accuracy of strip width, model to compensate width spread during roughing mill has been developed. To measure the amount of width spread during the production rolling more precisely, special roughing rolling procedures for the horizontal rolling and dog-bone rolling were designed in the actual production mill. From the operational data analysis, it is known that the prime factors influencing on the width spread were strip width, strip thickness, edging amount, number of pass and type of edger roll etc., Based upon the statistical analysis of rolling data, new models which can predict width spread during horizontal rolling and dog-bone rolling were developed and tested on the actual processing conditions for the reliability. The application test showed that newly developed model gave fairly accurate predictions on the width spread during roughing passes.

  • PDF

Comparison of Tooth Whitening Efficacy between Gel and Strip with Light Activator (광을 이용한 2.9% 과산화수소 함유 젤과 첩부제의 치아미백효과 비교)

  • Kim, Ji-Hye;Bang, Seong-Eun;Kim, Ji-Young;Ahn, Jae-Hyun
    • Journal of dental hygiene science
    • /
    • v.17 no.6
    • /
    • pp.481-486
    • /
    • 2017
  • The study aimed to compare the whitening efficacy of a strip and gel containing 2.9% hydrogen peroxide, using a tooth whitening light activator. The whitening effect was compared through in vitro and in vivo studies. In the in vitro study, we used stained hydroxyapatite (HAP) specimens as artificial teeth. HAP specimens were made using HAP powder and polyvinyl alcohol solution, and stained by modified Stookey's method. A whitening gel and whitening strip were applied to the respective specimens for 20 minutes, with a light activator. The color changes were measured using a colorimeter. In the in vivo study, one group (test 1) used the gel with a light activator and the other group (test 2) used a strip with the same activator for 15 minutes a day, for four consecutive days. An organoleptic evaluation using a Vita shade guide and instrumental evaluation using a Shade eye-NCC (Shofu Co., Japan) were performed. The color change values (${\Delta}E^*$) in the in vitro study revealed the strip with the light activator to be more effective than the gel with the same activator (p<0.001). In the in vivo study, even though there was no significant difference between the groups with respect to the ${\Delta}E^*$, using either the Shade eye-NCC or the Vita shade guide, the change in yellowness (${\Delta}b^*$) was statistically significant (p=0.024). In conclusion, test 2 group that used 2.9% hydrogen peroxide strip with a light activator, showed a tendency towards increased whitening than test 1 group that used the gel with the same activator; however further studies are needed to validate the above finding.

A Comparative Study on the Shear-Strengthening Effect of RC Beams Strengthened by CFS or CFRP (CFS 및 CFRP로 전단보강된 RC보의 전단보강효과 비교연구)

  • 심종성;김규선;황성욱;김정구;이석무
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.697-702
    • /
    • 1997
  • This study presents test results of RC beams strengthened by carbon fiber sheet (CFS) or carbon fiber reinforced plastics (CFRP) for increasing shear resistance. Fifteen specimens were tested, and the test was performed with different parameters including the type of strengthening materials (CFS, CFRP), shear-strengthening methods (wing type, jacket type, strip type), strip-spacing, strengthening direction of FRP. The results show that shear-damaged RC beams strengthened by either CFS or CFRP have more improved the shear capacity.

  • PDF