• Title/Summary/Keyword: test standard

Search Result 8,403, Processing Time 0.035 seconds

A study on the appraisal standard for purchasing the clothing made of organic cotton and the post-purchase satisfaction and dissatisfaction. - Focused on the adult women in from their 20's to 50's - (유기농 면 의류 제품 구매 시 평가기준 및 구매 후 만족 불만족에 관한 연구 - 20대에서 50대까지의 성인여성을 중심으로 -)

  • Park, Young-Hee
    • Journal of Fashion Business
    • /
    • v.15 no.1
    • /
    • pp.50-62
    • /
    • 2011
  • The purpose of this study is to catch the difference for the appraisal standard of a product which the adult women's consumers think importantly when they purchase the clothing made of organic cotton and the appraisal standard according to the demographic characteristics. The data collection for research was done for the women in from their 20's to 50's who are living in the regions of Gyungnam, Busan, Ulsan in Korea. The copies of the used questionnaire were 622 copies. To analyze the collected data, ${\chi}^2$-test, t-test, Cronbach's ${\alpha}$ test, ANOVA, Duncan test were carried out by SPSS 14.0. As the analysis result of data, the appraisal standard for purchasing the clothing made of organic cotton was classified with the five factors. The appraisal standard which the adult women's consumers think importantly when they purchase the clothing made of organic cotton showed the significant difference according to the demographic characteristics. The ratio for post-purchase dissatisfaction showed higher than the one for satisfaction. The dissatisfaction showed the significant difference according to the demographic characteristics. The dissatisfaction for a high price, color and insufficient design showed a relatively high ratio.

A Study on the Evaluation of the Pipe Fracture Characteristic (실배관 파괴특성 평가에 관한 연구)

  • Park Jae-Sil;Kim Young-Jin;Seok Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.1 s.232
    • /
    • pp.107-114
    • /
    • 2005
  • In order to analyze the elastic-plastic fracture behavior of a structure, the fracture resistance curve of the material should be known first. The standard CT specimen was used to obtain the fracture resistance curves of a piping system. However, it is known that the fracture resistance curve by the standard CT specimen is very conservative to evaluate the integrity of a structure. Also the fracture resistance curve is effected by the specimen geometry and the dimensions because of the constraint effect. The objective of this paper is to be certain the conservativeness of the fracture resistance curve by the standard CT specimen and to provide an additional safety margin. For these, the fracture tests using a real pipe specimen and the standard CT specimen test were performed. A 4-point bending jig was manufactured for the pipe test and the direct current potential drop method was used to measure the crack extension and the length for the pipe test. Also finite element analyses were performed with a CT specimen and a pipe in order to prove the additional safety margin. From the result of tests and analyses of the pipe and the standard CT specimen, it was observed that the fracture analysis with the standard CT specimen is conservative and the additional safety margin was proved.

Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy (경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.

A Case Study on Item Analysis and Standard Setting of the Physics Basic Ability Test for Engineering College Students (공학계열 대학생 물리 기초학력평가 문항분석 및 성취수준 설정 사례연구)

  • Lee, Keumho;Jung, Hyekyung
    • Journal of Engineering Education Research
    • /
    • v.26 no.6
    • /
    • pp.40-50
    • /
    • 2023
  • This study is to examine the validity of assessing basic-level proficiency in physics among incoming engineering freshmen through item analysis and standard setting. For empirical analysis, we examined the physics subject taken by the freshman class of 2021 at K University, considering its significance for engineering students. In this study, we initially performed item analysis utilizing both classical test theory and item response theory. Subsequently, leveraging the item and test information, we employed a modified Angoff method and the Bookmark method for standard setting. Consequently, the difficulty level initially set during item development was found to be higher than the actual performance level exhibited by the students. This study highlights a discernible disparity between the expected university standard and the real proficiency level of incoming freshmen in terms of basic academic ability in physics. Based on these research findings, a comprehensive discussion on the fundamental academic competence of engineering students was conducted, underscoring the necessity for formulating a tailored learning approach leveraging the outcomes from the basic ability test.

Fundamental study on the development of the testing method of Triclosan with GC/ECD and GC/MS (GC/ECD 및 GC/MS를 이용한 트리클로산 정량분석에 관한 기초 연구)

  • Jeong, Hui-Jae;Lee, Jae-In;Kweon, Deok-Jun;Eom, Hui-Jeong;Choi, Zel-Ho;Choi, Ki-In
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.410-415
    • /
    • 2012
  • In this study, a fundamental study was conducted to establish the method for quantitative analysis and pretreatment of triclosan, one of the chemicals to be used as bactericides, detergents, and sterilizers. The extraction efficiency of triclosan was the highest when it was extracted by soxhlet apparatus with n-hexane, and it showed a satisfactory result when the samples were analyzed with both GC/ECD and GC/MS. To evaluate the reproductivity of the results, each 30 reference samples made with paper filter and cotton wool was prepared in this study. From the results with high extraction effectiveness, low analysis deviation, and good statistical analysis data, the method for the extraction and analysis for triclosan were resonable for the paper and textile samples applied in this study.

A Study on the Test Standards at Low Temperature of Rubber Suspension Components of Railway Vehicle (철도차량 고무 현가부품의 내한성 시험기준연구)

  • Yoon, Tae-Ho;Jang, Seung-Ho;Choi, Byoung-Il;Lee, Chan-Woo;Na, Hee-Seung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.372-376
    • /
    • 2004
  • In this paper, the standard test methods at low temperature of rubber suspension components of railway vehicle are investigated and reviewed. In order to connect the TKR(Trans-Korean Railway)-TSR(Trans-Siberian Railway), it is necessary to evaluate the performance of rubber suspenion components of railway vehicle. In the current Korean Standard, the test method at low temperature of railway vehilce components and the test method of rubber bellows of air spring are specified. But, the specified test temperature is higher than the the operating temperature of TSR railway. So, the in-depth research for the test method and performance evaluation technique of rubber suspension component at low temperature is necessary and current KS code should be adjusted.

  • PDF

Reliability Prediction using Telcordia SR-332 in Electric Home Appliance (Telcordia SR-332를 이용한 가전제품 신뢰도 예측)

  • Lee Duck-Kyu
    • Journal of Applied Reliability
    • /
    • v.5 no.4
    • /
    • pp.427-438
    • /
    • 2005
  • This paper is concerned with the problem in predicting the reliability of an LCD product, Product reliability calculation methods classify accelerated life test (ALT) and using the reliability standard as MIL-HDBK-217F and Telcordia SR-332. The reliability standard can calculate estimating value more quickly than accelerated life test. The system MTBF was calculated in accordance of Telcordia SR-332 standard which includes directions of part electronic measurement, temperature rise and environmental test data. This research is intended to obtain the useful information for each electric design step to save time and cost.

  • PDF

Analysis and Evaluation of the Accuracy of Electromagnetic Power Measurement at National Calibration and Test Organizations (국가교정검사기관의 전자파전력 측정정확도의 분석 및 평가)

  • 강태원;강웅택;박병권
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.1
    • /
    • pp.53-60
    • /
    • 1995
  • The aims of this study are to evaluate the measurement capability of the electromagnetic power and to understand the current state of standard maintanance of the eight participants among the thirteen national calibration and test organizations. The calibration factors were measured at six test frequencies, 50, 100, 500, 1000, 5000, 10000 MHz by organizations and KRISS on the basis of round robin test. The results were analyzed by calculating the standard deviation of the measured values from the standard values. The analysis shows good agreement within 1.0% for all participants at the measurement frequencies. Therefore, the measurement capability of all participants is good in the frequency range of 50 MHz to 10 GHz. For the four participants which specified standard deviations of repeated measurements in their reporst, the total uncertainties is less than 1.9% at the measurement frequencies.

  • PDF

An Experimental Study on Standard Establishment of Sump Model Test in Pump Station (펌프장 Sump 모델 시험기준 수립을 위한 실험 연구)

  • Lee, L.Y.;Kim, B.S.;Lee, D.G.;Oh, Y.M.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.582-588
    • /
    • 2005
  • An experimental study to establish a standard of sump model test of pump station was implemented. Comparison of foreign standard was also performed. Configuration condition around a bell mouth suction intake was easily adjusted by 3-axis traversing system and partition allocation. Operational condition was also varied widely to give accurate test data. PIV was also introduced to produce Quantitative analysis of flow field such as free-surface vortex and submerged vortex occurring in the model test. More detailed vortex behaviors were represented by PIV analysis.

  • PDF

Middleware Test Framework for Mobile Devices (이동단말용 미들웨어 테스트 프레임워크)

  • Shin, Seok-Kyoo;Lee, Sang-Soo;Yang, Hae-Sool
    • Journal of Information Technology Services
    • /
    • v.6 no.2
    • /
    • pp.153-160
    • /
    • 2007
  • Middleware for mobile devices, embedded middleware, is used for mobile devices, cellular phone and DMB related services. It is essential for middleware providers to provide high quality middleware in conformity with its standard and interoperability on hardware platforms. The standard conformance and interoperability of embedded middleware are the key factors to make service providers succeed in their business. The quality of embedded middleware could be secured when Tests for the standard conformance and interoperability of embedded middleware are performed with well established test framework. In this paper, we describe middleware testing methodology of standard conformance, interoperability and middleware test framework for mobile devices.