• Title/Summary/Keyword: test sensitivity

Search Result 2,854, Processing Time 0.029 seconds

Treatment Results of Multidrug Resistant Tuberculosis in a University Hospital in Korea (다제내성 결핵의 치료 성적)

  • Yum, Ho-Kee;Song, Yeong-Su;Choi, Sao-Jean;Lee, Bong-Choon;Kim, Dong-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.6
    • /
    • pp.862-870
    • /
    • 1996
  • Background : Multidrug-resistant tuberculosis(MDR-Tb) has been increased not only in Asia but also in Western society, which may cause public health problems and reduce the efficacy of treatment of tuberculosis. In Western society HIV infection is believed to do a central role in increasing incidence of MDR tuberculosis, but MDR-Tb in Korea may be somewhat different about clinical features, underlying disorders, and prognosis. Goble et al reponed that overall treatment failure rate in MDR-Tb including resistance to isoniazid(INH) and rifampin (RFP) was 44 %. The aim of this study is to find the treatment result in Korea and the factors determining the prognosis. Methods: A retrospective study of pulmonary tuberculosis cultured M. tuberculosis from sputum or bronchial washing fluid between 1986 through 1992 was conducted in the Seoul Paik Hospital, Inje University. We reviewed clinical courses of 141 patients, who had a tuberculosis with resistance to 2 or more drugs including isoniazid(INH) and rifampin(RFP). One hundred and 4 patients of 141 patients had completed treatment and followed up for more than one year. Results: Of 104 (mean age $43.6{\pm}16.7$, M: F=63 : 41) patients with sufficient follow-up data, 73(84.6%) patients responded which is defined as negative Sputum cultures for at least 3 consecutive months. Seven patients(6.7%) had a failure in negative conversion and 9(8.7%) of the patients who initially responded relapsed. Overall treatment failure rate was 15.4%, Patients who were treated for less than 12 months had a higher relapse rate(12.3%) than 18 months(4.9%). And there was a statistically significant correlation between the relapse rate and the number of drugs to which isolates wera resistant(p<0.05). Conclusion : The treatment failure rate of MDR-Tb in Korea was lower than previous studies in western Country and the major determining factor of prognosis was the number of resistant drugs to M. tuberculosis at drug sensitivity test. For reducing the relapse rate, we recommend more than 12 months of treatment for MDR tuberculosis.

  • PDF

Synthesis, Characterizations, and Applications of Metal-Ions Incorporated High Quality MCM-41 Catalysts (고품질 금속 이온 첨가 MCM-41 분자체 촉매의 제법, 특성화 및 응용 반응)

  • Lim, Steven S.;Haller, Gary L.
    • Korean Chemical Engineering Research
    • /
    • v.51 no.4
    • /
    • pp.443-454
    • /
    • 2013
  • Various metal ions (transition and base metals) incorporated MCM-41 catalysts can be synthesized using colloidal and soluble silica with non-sodium involved process. Transition metal ion-typically $V^{5+}$, $Co^{2+}$, and $Ni^{2+}$-incorporated MCM-41 catalysts were synthesized by isomorphous substitution of Si ions in the framework. Each incorporated metal ion created a single species in the silica framework, single-site solid catalyst, showing a substantial stability in reduction and catalytic activity. Radius of pore curvature effect was investigated with Co-MCM-41 by temperature programmed reduction (TPR). The size of metallic Co clusters, sub-nanometer, could be controlled by a proper reduction treatment of Co-MCM-41 having different pore size and the initial pH adjustment of the Co-MCM-41 synthesis solution. These small metallic clusters showed a high stability under a harsh reaction condition without serious migration, resulting from a direct anchoring of small metallic clusters to the partially or unreduced metal ions on the surface. After a complete reduction, partial occlusion of the metallic cluster surface by amorphous silica stabilized the particles against aggregations. As a probe reaction of particle size sensitivity, carbon single wall nanotubes (SWNT) were synthesized using Co-MCM-41. A metallic cluster stability test was performed by CO methanation using Co- and Ni-MCM-41. Methanol and methane partial oxidations were carried out with V-MCM-41, and the radius of pore curvature effect on the catalytic activity was investigated.

Detection of Salmonella Using the Loop Mediated Isothermal Amplification and Real-time PCR (등온 증폭법과 Real-time PCR을 이용한 Salmonella 검출)

  • Ahn, Young-Chang;Cho, Min-Ho;Yoon, Il-Kyu;Jung, Duck-Hyun;Lee, Eun-Young;Kim, Jin-Ho;Jang, Won-Cheoul
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.2
    • /
    • pp.215-221
    • /
    • 2010
  • Salmonella is an important food-and water-borne pathogen associated with acute gastrointestinal illnesses around the world. The most common serotypes isolated from humans are Salmonella enterica serotype Typhimurium (S. Typhimurium) and S. Enteritidis. Traditional detection methods for Salmonella are based on cultures using selective media and characterization of suspicious colonies by biochemical and serological tests. These methods are generally time-consuming and not so highly sensitive. Recently, the Loop Mediated Isothermal Amplification and real-time PCR has been used as a highly sensitive, specific, and rapid test for the presence of pathogenic bacteria. In this study, a LAMP and real-time PCR was used to detect S. Typhimurium and S. Enteritidis. We selected target genes, which were the in invA and a randomly cloned sequence specific for the genus Salmonella. With LAMP and real-time PCR, random sequence was detected from Salmonella spp, invA were detected from all strain of S. Typhimurium and S. Enteritidis. This assay indicate that the specificity, sensitivity and rapid of the LAMP and real-time PCR make them potentially valuable tools for detection of S. Typhimurium and S. Enteritidis.

Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study

  • Lee, Jungwon;Pyo, Se-Wook;Cho, Hyun-Jae;An, Jung-Sub;Lee, Jae-Hyun;Koo, Ki-Tae;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.1
    • /
    • pp.56-66
    • /
    • 2020
  • Purpose: A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Methods: Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. Results: The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Conclusions: Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.

Dynamic Strain Aging of Zircaloy-4 PWR Fuel Cladding in Biaxial Stress State (가압경수로용 지르칼로이-4 피복관의 2축 응력 인장시 동적 변형 시효)

  • Park, Ki-Seong;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.89-98
    • /
    • 1989
  • The expanding copper mandrel test performed at three strain rates (3.2$\times$10E -5/s, 2.0$\times$10E-6/s and 1.2$\times$10E-7/s) over 553-873 K temperature range by varying the heating rates (8-1$0^{\circ}C$/s, 1-2$^{\circ}C$/s and 0.5$^{\circ}C$/s) in air and in vacuum (5$\times$10E-5 torr). The yield stress peak, the strain rate sensitivity minimum and the activation volume peaks could be explained in terms of the dynamic strain aging. The activation energy for dynamic strain aging obtained from the yield stress peak temperature and strain rate was 196 KJ/mol and this value was in good agreement with the activation energy for oxygen diffusion in $\alpha$-zirconium and Zircaloy-2 (207-220 KJ/mol). Therefore, oxygen atoms are responsible for the dynamic strain aging which appeared between 573 K and 673 K. The yield stress increase due to the oxidation was obtained by comparing the yield stress in air with that in vacuum and represented by the percentage increase of yield stress ( $\sigma$$^{a}$ $_{y}$ - $\sigma$$^{v}$ $_{y}$ / $\sigma$$^{v}$ $_{y}$ ). The slower the strain rate, the greater the percentage increase occurs. In order to estimate the yield stress of PWR fuel cladding material under the service environment, the yield stress in water was obtained by comparing the oxidation rate in air that in water assuming the relationship between the oxygen pick-up amount and the yield stress increase.

  • PDF

Determining the Orientations of Broadband Stations in South Korea using Ambient Noise Cross-correlation (배경잡음 교차상관을 이용한 국내 광대역 지진계의 방위각 보정값 측정)

  • Lee, Sang-Jun;Rhie, Junkee
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2015
  • Orientation corrections for Korean seismic stations were calculated by using ambient noise cross-correlation. This method uses Rayleigh waves extracted from ambient noise cross-correlation instead of teleseismic waveforms from earthquakes, which have been generally used for previous studies. The theoretical background of the method is that the phase of radial-vertical cross-correlation function should be the same as that of $90^{\circ}$ phase-shifted vertical-vertical cross-correlation function. The results calculated from stacked cross-correlograms from Jan. 2007 to Sep. 2008 are comparable to the previous results obtained from teleseismic waveforms. In addition, overall the standard deviations of orientation corrections are less than $5^{\circ}$. The temporal variation in orientation corrections calculated for every 30 days shows no significant change and also standard deviations of them are mostly less than $5^{\circ}$. This means that the orientations of stations used in this study have been kept constant during the period. The sensitivity test for stacking period of the ambient noise cross-correlation method shows that continuous ambient noise record of at least about 30 days is required for estimating reliable orientation corrections.

Locating Microseismic Events using a Single Vertical Well Data (단일 수직 관측정 자료를 이용한 미소진동 위치결정)

  • Kim, Dowan;Kim, Myungsun;Byun, Joongmoo;Seol, Soon Jee
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.2
    • /
    • pp.64-73
    • /
    • 2015
  • Recently, hydraulic fracturing is used in various fields and microseismic monitoring is one of the best methods for judging where hydraulic fractures exist and how they are developing. When locating microseismic events using single vertical well data, distances from the vertical array and depths from the surface are generally decided using time differences between compressional (P) wave and shear (S) wave arrivals and azimuths are calculated using P wave hodogram analysis. However, in field data, it is sometimes hard to acquire P wave data which has smaller amplitude than S wave because microseismic data often have very low signal to noise (S/N) ratio. To overcome this problem, in this study, we developed a grid search algorithm which can find event location using all combinations of arrival times recorded at receivers. In addition, we introduced and analyzed the method which calculates azimuths using S wave. The tests of synthetic data show the inversion method using all combinations of arrival times and receivers can locate events without considering the origin time even using only single phase. In addition, the method can locate events with higher accuracy and has lower sensitivity on first arrival picking errors than conventional method. The method which calculates azimuths using S wave can provide reliable results when the dip between event and receiver is relatively small. However, this method shows the limitation when dip is greater than about $20^{\circ}$ in our model test.

Comparison of Four Different Isolation Media for Staphylococcus aureus (황색포도상구균 분리배지 비교)

  • Oh, Min-Hee;Kang, Seong-Il;Hong, Sang-Phil;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.5
    • /
    • pp.606-611
    • /
    • 2009
  • Performance test was carried out between selective media which are generally used in Staphylococcus aureus isolation from food. Sensitivity, determined according to the appearance of characteristic colonies when 30 different S. aureus strains were tested, resulted as Baird-Parker agar (RPF)> $Petrifilm^{TM}$ Staph Express plate> Baird-Parker agar> Mannitol salt agar. Also, the four different media showed the same selectivity because all tested media did not produce the false positive colonies. Recovery efficiency from the artificially inoculated foodstuff was almost the same for the tested media. Presumptive colonies were collected from the dried fishery product using Mannitol salt agar and collected strains were tested on 4 different selective agar. Almost presumptive strains did not show the false positive colonies except for S. carnosus ssp carnosus. This strain was identified as false positive colonies on Mannitol salt agar, Baird-Parker agar and $Petrifilm^{TM}$ Staph Express plate. But Baird-Parker agar (RPF) did not show the false positive colonies with the same strains. So, it was concluded that the Baird-Parker agar (RPF) has more higher selectivity than other tested media in this experiment.

Usefulness of Automated PCR Test for the Detection of Mycobacterium Tuberculosis in Fresh Biopsy Tissues (신선조직 검체에서 결핵균 검출을 위한 자동화 중합효소연쇄반응 검사의 유용성)

  • Choi, Woo Soon;Shin, So Young;Kim, Jong Ok;Kim, Myung Sook;Lee, Hye Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.54-59
    • /
    • 2006
  • Background: Although there have been several studies regarding the clinical value of an automated TB-PCR study using sputum, bronchial washing, and other body fluid samples for the detection of pulmonary tuberculosis, there are only a few reports on the use of fresh tissue samples. Materials and methods: The acid-fast bacilli stain(AFB), tuberculosis culture, automated TB-PCR study, and histopathology examination were performed in 42 fresh tissue samples. Results: Among the 42 cases, 18 cases were diagnosed with tuberculosis based on the clinical findings. Sixteen of the 18 cases were TB-PCR positive and of these 16 cases, only 2 cases were positive in the AFB stain or culture study. However, all 18 cases showed the histopathology findings of chronic granulomatous inflammation that was compatible with tuberculosis. Based on the clinical findings, the sensitivity, specificity, positive predictability, and negative predictability of the automated TB-PCR study were 88.9%, 100%, 100%, and 92.3% respectively. Conclusion: An automated TB-PCR assay is an important diagnostic tool for diagnosing tuberculosis in fresh tissue samples.

Antimicrobial Activities of Scutellariae Radix Extract against Vibrio parahaemolyticus (Vibrio parahaemolyticus에 대한 황금추출물의 항균활성)

  • 조성환;김영록
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.3
    • /
    • pp.534-538
    • /
    • 2002
  • To investigate the antimicrobial effects of Scutellariae Radix extract against Vibrio parahaemolyticus from food samples, Vibrio parahaemolyticus strains isolated from Tapes philippinarum were examined for their sensitivity to Scutellariae Radix extract. Total 66 Vibrio parahaemolyticus strains were isolated from Tapes philippinarm 72 samples (91.7%). The serotypes of isolated Vibrio parahemolytics were K-I group 7 strains (10.6%), K-IV group 5 strains (7.6%), K-II group 2 strains (3.0%), K-V group 2 strains (3.0%), K-VII group 2 strains (3.0%), K-VI group 1 strains (1.5%), K-VIII group 1 strains (1.5%) and antisera UT K-group 46 strains (69.7%) on antisera agglutination test, but K-III group and K-IX group strains were not found. The growth curves of isolates showed lag phase, logarithmic phase, stationary phase and death phase as typical sigmoid curve on the shellfish samples. After 6 hours, the group containing Scutellariae Radix extract differs from the control on shellfish samples in the growth inhibition curves, and Vibrio parahaemolyticus were inhibited in more than 1000 ppm Scutellariae Radix extract. The morphological changes were observed by transmission electron microscope and the microbial cells membrane was destroyed by Scutellariae Radix extract.